STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

Similar documents
Standards Update Notice (SUN) Issued: February 2, 2017

Standards Update Notice (SUN) Issued: January 9, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 28, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 16, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: April 26, 2018

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 19, 2018

CERTIFICATION BULLETIN

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

NFPA 72 Code Changes vs 2013

Procedure for the Approval of New Fire Detection and Alarm Technologies

Safety Standard for Automatic Residential Garage Door Operators. SUMMARY: The Consumer Product Safety Commission ( Commission or CPSC ) is

UL Revision 5. - Commercial Door Installations -

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

Australian Standard. Safeguarding of machinery

Listing Constructional Data Report (CDR)

AS/NZS :2011. Household and similar electrical appliances Safety AS/NZS :2011. Part 1: General requirements

15900 HVAC INSTRUMENTATION AND CONTROLS

NEC ROP/ROC Code Making Panel Meetings

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY

Bimetal Disc Thermostat. Product Information and Application Notes

INTERNATIONAL STANDARD

0.4 In the preparation of this standard, assistance has been derived from the following standards:

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

CERTIFICATION BULLETIN

This document is a preview generated by EVS

Australian Standard. Automatic fire detection and alarm systems System design, installation, and commissioning AS

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

Rules for Intruder Alarm Systems

INTERNATIONAL STANDARD

Spark Extinguishing Systems

9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

INTERNATIONAL STANDARD

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

EC type approval protocol No. 4 Domestic washing and drying procedures for textiles toys intended for children under 36 months (Rev2)

SOUTH AFRICAN NATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

The MCD-111 AUTOKLAW Microprocessor Controller Version 1.00 User s Manual

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

User Manual. Rooster series. This Manual applies to: Drying ovens and sterilizers. Rooster Series. Models : Rooster 30, 55, 80, 110, 140, 210 and 230.

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

DIVISION LOW VOLTAGE DE-ICING / SNOW MELTING SYSTEM IN EXISTING ASPHALT/CONCRETE

Dryer Controller M720

INTERNATIONAL STANDARD

SPECIFICATION: AlarmLine TM INTELLIGENT LINEAR HEAT DETECTION

Hydrogen Sensor Testing and Certification Underwriters Laboratories Inc.

INTERNATIONAL STANDARD

AS/NZS IEC :2013

Completed Projects / Projets terminés

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

INTERNATIONAL STANDARD

Australian/New Zealand Standard

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

SECTION ISOLATED POWER SYSTEMS

What You Need to Know About UL rd Edition

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

COUNCIL DIRECTIVE of 1 December 1986 on airborne noise emitted by household appliances (86/594/EEC)

INTERNATIONAL STANDARD

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Alarm. A warning of danger. An indication of the existence of a condition that requires immediate action. (SIG-FUN)

PolySwitch TS600 Overcurrent Protection Devices

Household and similar electrical appliances Safety

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

UFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Standard Development Timeline

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

Delayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.

This document is a preview generated by EVS

INTERNATIONAL STANDARD

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

EWM 1000 COMPONENT FUNCTIONALITY

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

NEMA Standards Publication ICS (R 2007) Adjustable Speed Electrical Power Drive Systems

COMITÉ EUROPÉEN DES ASSURANCES

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

FINANCIAL SERVICES COMPENSATION SCHEME (SINGLE CUSTOMER VIEW SUPERVISION AND OTHER AMENDMENTS) INSTRUMENT 2009

GB Translated English of Chinese Standard: GB

Australian Standard. Degrees of protection provided by enclosures (IP Code) AS IEC Ed 2.1:2001 AS 60529

Proposed Changes to NFPA

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

REPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..

Products :: Circuit Protection :: Thermal Circuit Breakers

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS

Transcription:

STANDARDS UPDATE NOTICE (SUN) ISSUED: March 2, 2018 STANDARD INFORMATION Standard Number: UL 1206 Standard Name: Standard for Electric Commercial Clothes-Washing Equipment Standard Edition and Issue Date: 4 th edition Dated April 22, 2003 Date of Revision: October 3, 2017 Date of Previous Revision of Standard: November 30, 2012 EFFECTIVE DATE OF NEW/REVISED REQUIREMENTS Effective Date: January 10, 2020 IMPACT, OVERVIEW, AND ACTION REQUIRED Impact Statement: A review of all Listing Reports is necessary to determine which products comply with new/revised requirements and which products will require re-evaluation. NOTE: Effective immediately, this revised standard will be exclusively used for evaluation of new products unless the Applicant requests in writing that current requirements be used along with their understanding that their listings will be withdrawn on Effective Date noted above, unless the product is found to comply with new/revised requirements. Overview of Changes: Modifications to update the motor overload protection requirements. Addition of New Section, 20A, Controls, to reflect current technology. Specific details of new/revised requirements are found in table below. If the applicable requirements noted in the table are not described in your report(s), these requirements will need to be confirmed as met and added to your report(s) such as markings, instructions, test results, etc. (as required). Client Action Required: Information To assist our Engineer with review of your Listing Reports, please submit technical information in response to the new/revised paragraphs noted in the attached or explain why these new/revised requirements do not apply to your product (s). Current Listings Not Active? Please immediately identify any current Listing Reports or products that are no longer active and should be removed from our records. We will do this at no charge as long as Intertek is notified in writing prior to the review of your reports. SFT-ETL-OP-29c (December 15, 2017) Standards Update Notice KR/LT 1

STANDARD INFORMATION CLAUSE VERDICT COMMENT Additions to existing requirements are underlined and deletions are shown lined out below. 17 Info Overload Protection 17.10 20A The overload protection required by 17.7 or 17.9 shall prevent the occurrence of the conditions specified in (a) and (b) of those paragraphs. Motor overload protection that complies with one of the following is Motor protectors complying with the applicable requirements in the Standard for Overheating Protection for Motors, UL 2111 are considered to comply with these the following requirements: a) Appliances having a device, which may be integral with the control of the appliance, responsive to motor current, as required by the National Electrical Code (NEC), for overload and overheating; b) Motors having inherent overheating protection in accordance with the requirements in the Standard for Thermally Protected Motors, UL 1004-3; c) Motors employing impedance protection complying with the locked-rotor requirements specified in the Standard for Impedance Protected Motors, UL 1004-2; or d) Motors employing electronic protection complying with the Standard for Electronically Protected Motors, UL 1004-7, or complying with the tests of UL 1004-3 and evaluated in accordance with Evaluation of Electronic Circuits, Supplement SA. See SA1.3. New section added; Controls 20A.1 General 20A.1.1 20A.1.2 20A.1.3 Components, wiring, printed wiring assemblies, insulating material, potting materials, and the like, and associated circuitry employed in controls, shall be investigated and found acceptable for the application in accordance with the specified component standards with respect to a risk of fire, electric shock, and injury to persons. Controls shall be so located or protected that they are not subjected to mechanical damage, excessive moisture, or excessive collection of lint. The operating mechanism of controls shall not subject electrical parts to undue strain. 2

Electronic circuits that manage a Safety Critical Function (SCF) shall be: 20A.1.4 20A.2.1 20A.2.2 20A.2.3 a) Reliable as defined as being able to maintain the SCF in the event of single defined component faults; and b) Not susceptible to electromagnetic environmental stresses encountered in the anticipated environments where the appliance will operate. An operating control shall comply with: b) The applicable requirements in the Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1 and the relevant Part 2. The cycle selection control, water level detection, out of balance detection, temperature-regulating devices and any control not relied upon to provide a required safety function are considered and to be tested and evaluated as operating. The minimum test parameters for the evaluation of an operating control to the Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1 and any applicable Part 2 are specified in Table 20A.1. Operating control correlation table Table 20A.1 20A.3 Controls that manage safety critical functions (protective controls) 20A.3.1 20A.3.2 20A.3.3 A control that manages a SCF shall comply with the requirements of: b) The requirements in the Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1 and the relevant Part 2 applicable to a Protective Control. Controls that manage a SCF shall also be evaluated for reliability in accordance with: b) The Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1 and any applicable Part 2. Electronic motor protection shall be evaluated in accordance with 17.10(d). 3

20A.3.4 Controls that manage a SCF and that does not rely on software shall comply with the standards specified in 20A.3.2 except for Controls Using Software, H.11.12, in the Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1. If software is relied upon to perform the protective control function, it shall be considered Software Class B as indicated in Table 20A.2. Protective control correlation table Table 20A.2 20A.3.5 20A.3.6 A door or lid interlock, secondary function control, electronic braking means, motor overload protection, temperature-limiting devices, combination temperatureregulating and -limiting devices, and any control relied upon for compliance with abnormal operation testing requirements shall be tested and evaluated as a control managing a SCF in accordance with the applicable requirements in Evaluation of Electronic Circuits, Supplement SA. The minimum test parameters for the evaluation of a control managing a SCF (protective control to the Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1) and the relevant Part 2 are specified in Table 20A.2. 20A.4 Temperature-regulating and temperature-limiting devices 20A.4.1 Temperature sensing device, such as a positive temperature coefficient (PTC) thermistor and a negative temperature coefficient (NTC) thermistor, that is used in combination with an electronic control and that together with the control manages a SCF shall comply with the Standard for Thermistor-Type Devices, UL 1434. 4

20A.4.2 20A.4.3 Protective temperature sensing controls shall have cut-in and cut-out temperatures that do not: a) Deviate from the manufacturer s specified limits in the as-received condition by more than either 6 C or 5 percent, whichever is greater; and b) Drift from the temperatures measured in the as -received condition by more than either 6 C or 5 percent, whichever is greater, after being subjected to the specified number of cycles in accordance with Table 20A.2 and, for electronic protective controls, the environmental stress tests in Section H.26 of the Standard for Automatic Electrical Controls Part 1: General Requirements, UL 60730-1. With respect to 20A.4.2, if a manufacturer declares a tighter tolerance, the deviation and drift shall remain within the manufacturer s declared values. 20A.5 Cycle selection controls 20A.5.1 20A.5.2 Clock-operated switches incorporating mechanical clockwork, such as gears, springs, and motors, shall comply with the applicable requirements in one of the following standards: b) Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Timers and Time Switches, UL 60730-2-7. A cycle selection control incorporating electronic timing or switching circuits, shall comply with the standards specified in 20A.2.1(b). 20A.6 Door/lid interlock or lock protective controls 20A.6.1 20A.6.2 20A.6.3 If a door-actuated or lid-actuated switch is employed to directly disconnect power to the motor, the switch shall comply with the Endurance Test as specified in 29.6 and with the applicable requirements in one of the following standards: a) Standard for Switches for Appliances Part 1: General Requirements, UL 61058-1; or b) Standard for Industrial Control Equipment, UL 508. If a door-actuated or lid-actuated switch is employed as a sensor for an electronic control to disconnect power to the motor, the switch and control shall comply with 20A.3. Endurance testing of a door or lid interlock and the associated braking means shall be conducted in accordance with 29.6. 20A.7 Water level detection controls 20A.7.1 If a switch is employed as part of a water level detection mechanism, it shall comply with the applicable requirements in one of the following standards: a) Standard for Switches for Appliances Part 1: General Requirements, UL 61058-1; or b) Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Automatic Electrical Air Flow, Water Flow and Water Level Sensing Controls, UL 60730-2-15. 5

20A.7.2 If a pressure or flow switch is employed as part of a water level detection mechanism, the switch shall comply with Flooding of Live Parts, Section 39 for gaskets or seals in contact with laundry detergent or bleach, Polymeric Materials, Section 44 for polymeric materials in contact with laundry detergent or bleach, and with the applicable requirements in one of the following standards: a) Standard for Industrial Control Equipment, UL 508; b) Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Automatic Electrical Pressure Sensing Controls Including Mechanical Requirements, UL 60730-2-6; or c) Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: Particular Requirements for Automatic Electrical Air Flow, Water Flow and Water Level Sensing Controls, UL 60730-2-15. CUSTOMERS PLEASE NOTE: This Table and column Verdict can be used in determining how your current or future production is or will be in compliance with new/revised requirements. 6