QRA10... QRA53... QRA55...

Similar documents
QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55...

QRA10... QRA53... QRA55...

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

Flame detector. Building Technologies Division Infrastructure & Cities Sector

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control:

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Infrared Flame Detectors

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Infrared Flame Detectors

RAR... Photocell Detectors. Building Technologies Division

Flame Safeguards LFE10. Building Technologies HVAC Products

UV Flame Supervision System

Flame Safeguards LFE10. Building Technologies HVAC Products

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Blue-flame Detectors

C Note! LGI16... Burner Controls. Building Technologies

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Basic unit with integrated air-fuel ratio control for forced draft burners

LAE10 LFE10. Use. Series 02

LGA... Gas Burner Controls. Building Technologies Division

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

Oil Burner Controls LOA3... Building Technologies HVAC Products

Oil Burner Controls LMO24... LMO44...

Product Range Overview

Oil Burner Controls LMO24... LMO44...

Burner controls. Building Technologies HVAC Products

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Burner Management System

Oil Burner Controls LOA3... Building Technologies Division

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

UV - flame detector dual fuel burners for intermittent burner operations

Use. The burner controls are certified to EN 230 and EN 298.

Description Control Box, type LOA 24 Control Box, type LOA 26 Control Box, type LMO Β2/C2 Control Box, type LMO B2 Control Box, type

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

LFL Series Burner Flame Safeguard Control

Burner Management System

Heating Element. Building Technologies HVAC Products

Burner Management System

Burner Controls. Building Technologies HVAC Products

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Gas Burner Controls. Building Technologies HVAC Products

for relative humidity and temperature

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

COMPACT FLAME CONTROLLER CFC 100

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

FIREYE C9707A ALL FUEL SCANNER

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

for relative humidity and temperature with calibration certificates

Eclipse 90 UV Scanner Model A Version 1

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

QFM21... Duct sensors. Symaro. for relative humidity and temperature

COMPACT FLAME CONTROLLER CFC 1000

Forced draught gas burner

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

Light oil / kerosene burner

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Chemical Processes in the Combustion

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

COMPACT FLAME CONTROLLER CFC 2000

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

FLV 40 UV Flame Detector

Distributed By: M&M Control Service, INC

MBCE-110/230UV Flame Sensor Module

for relative humidity and temperature

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Wide Band Flame Detector KLC 20 for all kind of oil flames with intermittent burnerr operations

Building Technologies Division

SIL3. C7961E,F Dynamic Self-Check Ultraviolet Flame Detector. Capable APPLICATION FEATURES PRODUCT DATA. Contents

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

LME75... Burner controls. Building Technologies

DESCRIPTION AND INSTALLATION

Light oil - kerosene burner

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Duct Temperature Sensors

C7061C/F ULTRA VIOLET FLAME DETECTOR FEATURES APPLICATION PRODUCT HANDBOOK. Contents

DESCRIPTION AND INSTALLATION

55UV5 SCANNER MODEL 1010

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Room Temperature Sensors

Distributed By: M&M Control Service, INC

Eclipse Self-Check UV Scanner

Class 1 laser beam sensor safe for your eyes

Fireye FLAME SCANNERS

FIREYE FLAME SCANNERS

Duct Air Quality Sensors

Class 1 laser beam sensor safe for your eyes

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

FIREYE FLAME SCANNERS

Building Technologies

1592P01. for liquids in piping DN

Transcription:

7 712 QRA7 with clamp QRA10... QRA53..., QRA55... with clamp QRA2... with clamp Flame Detectors QRA2... QRA10... QRA53... QRA55... QRA73 QRA75 The UV flame detectors are designed for use with Siemens burner controls, for the supervision of gas or oil flames. The QRA... and this Data Sheet are intended for use by OEMs which integrate the flame detectors in their products. 15.08.2014 Infrastructure & Cities Sector

Use The flame detectors are used for the supervision of gas flames, yellow- or blue-burning oil flames and for ignition spark proving. Flame detector For use with burner control type Operating mode QRA2..., QRA10... LGB2... / LGB4... with AGQ1... Intermittent LFL... LFE1... LFE10... LMG... with AGQ2... LME21 / LME22 / LME39 with AGQ3 / LME7... LMV2 / LMV3... LMV5 with AGQ1 QRA53..., QRA55... LGK16... LGI16... Continuous operation QRA73, QRA75 LMV5 Continuous operation Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! All activities (mounting, installation and service work, etc.) must be performed by qualified staff Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If not observed, there is a risk of electric shock hazard. Ensure protection against electric shock hazard by providing adequate protection for the terminals. If this is not observed, there is a risk of electric shock Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state. If this is not observed, there is a risk of electric shock Halogen lamps, welding equipment, special lamps or ignition sparks may produce sufficient radiation for the detector s UV cell to ignite. X-rays and gamma radiation can also generate erroneous flame signals. If this is not observed, there is a risk of loss of safety functions Fall or shock can adversely affect the safety functions. Such units must not be put into operation, even if they do not exhibit any damage. If this is not observed, there is a risk of loss of safety functions and a risk of electric shock Mounting notes Ensure that the relevant national safety regulations are complied with Installation notes Always run the high-voltage ignition cables separate while observing the greatest possible distance to the detector and to other cables Electrical connection of the flame detector It is important to achieve practically disturbance- and loss-free signal transmission: Never run the detector cable together with other cables Line capacitance reduces the magnitude of the flame signal Use a separate cable Observe the permissible lengths of the detector cable (refer to «Technical data» in the Data Sheet of the relevant burner control) 2/14

Commissioning notes Trouble-free burner operation is ensured only when the intensity of UV radiation at the detector s location is high enough for the detector s UV cell to ignite during each half wave. The intensity of UV radiation at the detector s location is checked through measurement of the detector current Measuring circuit for QRA2..., QRA10..., QRA5...series D and QRA5...series G Legend Measuring circuit for QRA5... up to the C-series and QRA5...series E 1) Connection of micro-ammeter across AGQ1... / AGQ2... / AGQ3... adapter and flame detector A Incidence of radiation M Micro-ammeter (DC), internal resistance 5000 C Electrolytic capacitor 100...470 µf, DC 10...25 V QRA53 AGM19 LGK16... QRA55 - + LG I 16... M KF8832 7712v03/9602 Note! The KF8832 flame detector current measuring device must not be used in continuous operation! Minimum detector current values required: Refer to the Data Sheet of the relevant burner control or to the Operating Instructions of the KF8832. Measuring circuit for QRA7... Legend M2 Voltmeter direct current voltage Measurement range 0...10 V Internal resistance Ri >10 MΩ 3/14

Certificates Conformity to EEC directives - Electromagnetic compatibility EMC (immunity) - Low-voltage directive 2004/108/EC 2006/95/EC ISO 9001: 2008 Cert. 00739 ISO 14001: 2004 Cert. 38233 Service notes Use the KF8832 service unit for short periods of time only. Disposal notes The flame detector contains electrical and electronic components and must not be disposed of together with domestic waste. Local and currently valid legislation must be observed. 4/14

Mechanical design Flame detectors QRA2... Flame detectors QRA10... Flame detectors QRA5..., QRA7 Plug AGM19 Adapter AGG16.C Plastic housing, metalized to prevent static charging caused by the air flow from the fan. For mounting direct on the burner. The detectors can be supplied with or without securing flange (version 4 241 8855 0/4 241 8898 0) and clamp (refer to «Type summary»). Die-cast aluminum housing with a 1 in. mounting coupling (D) and connection facility for cooling air. The housing of this detector has a bayonet fitting which allows it to be secured either directly to the 1 in. mounting coupling or to the AGG06 glass holder. The 1 in. mounting coupling can be screwed to a viewing tube or to the AGG07 ball head. The Pg cable gland can be removed and replaced, if some other detector cable shall be used. The detector s UV cell is located behind a swiveling shutter at the front end of the detector tube which is flanged to the housing. A quartz-glass window protects the tube and the shutter against dirt. The detector s housing accommodates a stepper motor to drive the shutter and the electronics to control the shutter. Using the AGG16.C adapter, this flame detectors can be mounted either directly on the burner, on a viewing tube or on a combustion chamber viewing hole. AGM19 complete with cable for the connection of QRA53... and QRA55... flame detectors. AGG16.C for QRA53..., QRA55..., made of die-cast aluminum with a 1 in. mounting coupling. The 1 in. mounting coupling (D) is attached to the housing with a bayonet fitting. QRA5... / QRA7... AGG16.C AGG03 AGG06 7712m08/0907 AGG02 AGG06 7712z05/0403 D AGG05 AGG07 QRA5... / QRA7 with AGG16.C and AGG06 Note! AGG03 or AGG02 can also be fitted in the 1 in. mounting coupling (D) of the AGG16.C (or QRA10...). An adapter combination with AGG06 glass holder, mounting coupling and ball joint for QRA53..., QRA55..., QRA7 and QRA10... is possible. Connector AGM23 Connector AGM23U Connector AGM23 with cable for the electrical connection of flame detector QRA7 Connector AGM23 with wires for the electrical connection of flame detector QRA7 in US design 5/14

Mechanical design (cont d) Glass and quartz-glass lens holder AGG06 The glass and quartz-glass lens holder AGG06 serves for holding the AGG03 lens and the AGG02 heat insulation glass. The lens is used to increase the sensitivity, and the heat insulation glass provides protection against high temperatures, thus extending the life of the UV cell. The AGG06 also allows various combinations of lens, heat insulation glass and 1 in. mounting coupling. When using the lens and the heat insulation glass, the AGG06 with the lens must be mounted as close as possible to the flame detector. AGG16.C AGG16.C AGG03! AGG02 AGG06 AGG06 7712z06/0403 Correct AGG02! AGG06 7712z07/0403 Wrong AGG03 AGG06 AGG06 has a bayonet fitting with which it is attached either to the housing of the AGG16.C or to the housing of the QRA10... and the 1 in. mounting coupling. By undoing the bayonet fittings on both sides, the AGG06 glass holder(s) can be easily detached from the combination of QRA10... or AGG16.C and QRA53... or QRA55... This facilitates straightforward cleaning of the glass or lens without having to remove them from the AGG06 glass holder. The intermediate rings are used for the smooth running of the bayonet fittings, especially where after removal of the flame detector the hole to the combustion chamber serves as a viewing tube. By fitting the intermediate ring to the appropriate bayonet connection, the combination can be undone where required by rotating the housing of the QRA10... or AGG16.C Quartz-glass lens AGG03 Heat insulation glass AGG02 Mounting coupling (D) Nipple AGG05 Ball head AGG07 AGG03 with spring washer and O-ring for increasing the sensitivity. AGG02 with spring washer and O-ring, offering the same mounting choices as AGG03. This heat insulation glass is required on applications where the temperature at the flame detector exceeds 80 C. Using the bayonet fitting, the 1 in. mounting coupling can be attached either to the AGG06, the AGG16.C or the QRA10... flame detector. The mounting coupling is supplied with the QRA10... or AGG16.C. 1 in. nipple AGG05 for connecting the 1 in. mounting coupling (D) to the AGG07 ball head. AGG07 with 1 in. internal thread. Connection on AGG05 and for use with the 1 in. mounting coupling and AGG06. The AGG07 is used for mounting on a rigid surface, such as the boiler wall. It facilitates optimum adjustment of the viewing angle. 6/14

Type summary Flame detectors Type reference Sensitivity Flange and clamp Terminal cover Spare UV tube QRA2 Normal Without Black AGR 4 502 1131 0 QRA2(1) QRA2(2) Normal Normal With 4 241 8855 0 / 4 199 8806 0 With 4 241 8898 0 / 4 199 8806 0 Black AGR 4 502 1131 0 Black AGR 4 502 1131 0 QRA2.9 ¹) Normal Without Black AGR 4 502 1131 0 QRA2M High Without Green AGR 4 502 4065 0 QRA2M(1) QRA2M(2) High High With 4 241 8855 0 / 4 199 8806 0 With 4 241 8898 0 / 4 199 8806 0 Green AGR 4 502 4065 0 Green AGR 4 502 4065 0 QRA10.C Normal --- --- AGR 4 502 1131 0 QRA10M.C High --- --- AGR 4 502 4065 0 1) With heat-resistant housing for ambient temperatures up to 200 C (short-time, up to a few seconds) Type reference Sensitivity Detector tube length Mains voltage Spare UV tube QRA53.E27 Normal 125 mm AC 220...240 V AGR 4 502 4065 0 QRA53.E17 Normal 125 mm AC 100...110 V AGR 4 502 4065 0 QRA53.G27 High 125 mm AC 220...240 V AGR 4 502 4065 0 QRA53.G17 High 125 mm AC 100...110 V AGR 4 502 4065 0 QRA55.E27 Normal 69 mm AC 220...240 V AGR 4 502 4065 0 QRA55.E17 Normal 69 mm AC 100...110 V AGR 4 502 4065 0 QRA55.G27 High 69 mm AC 220...240 V AGR 4 502 4065 0 QRA55.G17 High 69 mm AC 100...110 V AGR 4 502 4065 0 Type reference Sensitivity Detector tube length Mains voltage Spare UV tube QRA73.A27 Normal 125 mm AC 230 V +10 / -15 % AGR 4 502 4065 0 QRA73.A17 Normal 125 mm AC 120 V +10 / -15 % AGR 4 502 4065 0 QRA75.A27 Normal 69 mm AC 230 V +10 / -15 % AGR 4 502 4065 0 QRA75.A17 Normal 69 mm AC 120 V +10 / -15 % AGR 4 502 4065 0 Note! Mounting Instruction for replacing of spare UV tube, refer to 4 319 9513 0 (M7712.5)! Note! All QRA5... and QRA7... are delivered complete with clamp. Use of the detector requires a connecting cable AGM19 / AGM23 / AGM23U (refer to «Accessories» for QRA5... / QRA7...). Accessories for QRA2... and QRA5... and QRA7 when ordered as single items Part For use with Part number Flange rounded ¹) QRA2... 4 241 8855 0 Flange straight ²) QRA2... 4 241 8898 0 Clamp ¹) ²) QRA2... 4 199 8806 0 Clamp for direct mounting QRA5... / QRA7 4 199 1034 0 1) Supplied with QRA2...(1) types 2) Supplied with QRA2...(2) types 7/14

Type summary (cont d) Accessories for QRA2... AGG09 IP40-Kit - cable sealing element Ø 5...8 mm Accessories for QRA5... / QRA7 AGG16.C adapter - for flame detector mounting QRA53... and QRA55... / QRA7 AGM19 connecting cable - cable length 2 m - with plug for QRA53..., QRA55... KF8832 unit for measuring the detector current - with QRA53..., QRA55... recommended for use with detector types up to the C-series AGM23 connecting cable - cable length 2 m - with plug for QRA7 AGM23U connecting cable - cable length 4 m - with plug for QRA7 - US design 8/14

Type summary (cont d) Accessories for QRA10... and AGG16.C AGG02 heat insulation glass - with spring washer and O-ring AGG03 quartz-glass lens - with spring washer and O-ring - for detectors of the B-series, lens AGG01 is available AGG05 nipple 1 in. AGG06 glass and quartz-glass lens holder - with intermediate ring AGG07 ball head - with 1 in. internal thread - swivel range 13 AGG08 IP65-kit for QRA10... - for different types of cable diameter Cable sealing element in mm Color 4...6,5 mm Yellow 6,5...9,5 Black 9...15 Red Ordering When ordering, please give type references according to «Type summary». 9/14

Technical data General detector data Average life of UV cell Perm. combustion chamber pressure - QRA10... - QRA10... + AGG03 or AGG02 Degree of protection - QRA2... IP20 Approx. 10,000 hours at max. 50 C, higher ambient temperatures reduce considerably the cell s life Max. 50 mbar Max. 500 mbar Note! IP40 conforming to DIN EN 60529 when using adequate cable entries (e.g. AGG09). - QRA10... - QRA5x.E... / QRA5x.G... - QRA7 Mounting position Weight - AGG01 - AGG02 - AGG03 - AGG05 - AGG06 - AGG07 - AGG16.C - QRA2... - QRA10... - QRA10... + AGG03 - QRA5x.E..., QRA5x.G... - QRA7 Ignition cable (only QRA2...) IP54 (IP65 with AGG08) IP65 IP65 Optional Approx. 10 g Approx. 10 g Approx. 10 g Approx. 170 g Approx. 160 g Approx. 1330 g Approx. 650 g Approx. 46 g Approx. 740 g Approx. 750 g Approx. 700 g Approx. 700 g 2 x 0.75 mm²; 5.1 mm dia. Environmental conditions Storage IEC 60721-3-1 Climatic conditions Class 1K3 Mechanical conditions Class 1M2 Temperature range -20...+60 C Humidity <95 % r.h. Transport IEC 60721-3-2 Climatic conditions Class 2K2 Mechanical conditions Class 2M2 Temperature range -20...+60 C Humidity <95 % r.h. Operation Climatic conditions Mechanical conditions Temperature range Humidity IEC 60721-3-3 Class 3K3 Class 3M3-20...+60 C <95 % r.h. Caution! Condensation, formation of ice and ingress of water are not permitted! If this is not observed, there is a risk of loss of safety functions and a risk of electric shock. 10/14

Function With this type of flame supervision, the UV radiation emitted by gas or oil flames is used to generate the flame signal. The radiation detector consists of a UV-sensitive cell with 2 electrodes, which ignite when illuminated with radiation in the 190...270 nm range of the spectrum, thereby triggering a current in the flame detector circuit. The UV cell does not respond to glowing firebrick in the combustion chamber, daylight or light from boiler room illumination. Dimensions (cont d) Dimensions in mm QRA2... 25...50 4 241 8898 0 4 241 8855 0 7712m16/0414 QRA10... 87 3 8 '' SW20 52 SW22 120 R1 '' UV 7712m02/0997 Pg13,5 65 66 11/14

Dimensions (cont d) Dimensions in mm QRA5x.E... / QRA5x.G... 7712m13/0909 32 75 12 124,5 (QRA53...) 68,5 (QRA55...) 108 64 112,1 72 QRA5... with AGG05, AGG06, AGG07, AGG16.C and AGM19 AGG16.C D AGG16.C 7712m01/0403 12/14

Dimensions (cont d) Dimensions in mm QRA7 with AGM23 12 32 75 124,5 (QRA73...) 68,5 (QRA75...) 108 112,1 62,1 72 7712m11/0108 QRA7 with AGM23U 32 75 12 124,5 (QRA73...) 68,5 (QRA75...) 108 112,1 81 72 7712m12/0108 Incidence of radiation for QRA5... / QRA7... UV 40 30 7712z08/0111 13/14

Dimensions (cont d) Dimensions in mm Accessories 4 199 1034 0 Clamp for direct mounting on the burner or the AGG16.C 46 40 7712m15/0111 60 AGG02 AGG03 4 241 8855 0 36 4 241 8898 0 7 R2 R0.3 24.3 R4 7 36 18 R4 R2 30 25 25 3 3 15 15 30 Company logo to LN 3 8380 0102 0.2 mm elevated 3 10 48 18 24 7712m09e/1001 Company logo to LN 3 8380 0102 0.2 mm elevated 3 10 24 48 7712m10e/1001 14/14 2014 Siemens AG Infrastructure & Cities Sector Subject to change!