Performance Rating of Active Chilled Beams

Similar documents
AHRI Standard 751 (SI) 2016 Standard for Performance Rating of Thermostatic Refrigerant Expansion Valves

Sound Performance Rating of Non-ducted Indoor Airconditioning

Sound Performance Rating of Outdoor Unitary Equipment

ANSI/AHRI Standard 620 (I-P) 2014 Standard for Performance Rating of Self-contained Humidifiers for Residential Applications

Performance Rating of Refrigerant Pressure Regulating Valves

ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers

Performance Rating of Unit Ventilators

Performance Rating of Heat Pump Pool Heaters

Performance Rating of Automatic Commercial Ice-makers

Flow Capacity Rating of Suction Line Filters and Suction Line Filter Driers

Performance Rating of Heat Pump Pool Heaters

AHRI Standard 870 (I-P) Standard for Performance Rating of Direct Geoexchange Heat Pumps

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Performance Rating of Computer and Data Processing Room Air Conditioners

Performance Rating of Commercial and Industrial Humidifiers

Standard for 2006 Performance Rating Of Positive Displacement Ammonia Compressors and Compressor Units

ANSI/AHRI Standard 1351 (SI) 2014 Standard for Mechanical Performance Rating of Central Station Air-handling Unit Casings

Acoustical Test Methods and Sound Power Rating Procedures for Transport Refrigeration Equipment

2013 Guideline for Specifying the Thermal Performance of Cool Storage Equipment. AHRI Guideline T (I-P)

ANSI/AHRI Standard Standard for Performance Rating of Indoor Pool Dehumidifiers

1997 STANDARD for APPLICATION OF SOUND RATING LEVELS OF OUTDOOR UNITARY EQUIPMENT. Standard NORTH FAIRFAX DRIVE! ARLINGTON, VIRGINIA 22203

AHRI Guideline N with Addendum Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

Specifications for Fluorocarbon Refrigerants

Specifications for Fluorocarbon Refrigerants

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

2015 Standard for Performance Rating of Refrigerant Recovery Equipment and Recovery/Recycling Equipment

ANSI/AHRI Standard 1360 (I-P) 2016 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners

AHRI Standard 1360 (I-P) 2017 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners

AHRI Standard 1250P (I-P) 2009 Standard for Performance Rating of Walk-In Coolers and Freezers

AHRI Guideline N Guideline for Assignment of Refrigerant Container Colors. ARI Standard 1200

Specifications for Refrigerants

Specifications for Refrigerants

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

Active Chilled Beams. Technical Data Concealed Ceiling Mounted Model With Vertical Coil and Integral Drain Pan

Units for suspended ceilings Type DID632

Don t Turn Active Beams Into Expensive Diffusers

This document is a preview generated by EVS

WATER-SOURCE HEAT PUMPS CERTIFICATION PROGRAM For 50 Hz Products

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Active Chilled Beams. Technical Data Bulkhead-Mounted Concealed Model With Horizontal Coil and Auxiliary Drain Pan

Units for suspended ceilings

HOTEL CHILLED BEAM IQ STAR SILENCIA

KLIMA Active Chilled Beams

INDOOR POOL DEHUMIDIFIERS CERTIFICATION PROGRAM

Active Chilled Beams

Modular Active. Chilled. Beams

Units for suspended cei lings

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Chilled Beam/Induction Unit

Methods of Testing Capacity of Refrigerant Solenoid Valves

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

TLW Therma-Fuser Linear Sidewall Thermally Powered VAV Diffuser

Oxyvap Evaporative Cooling Applications

Product Data. Features/Benefits. 36CBAC,AE,AF,AH,AQ,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

Therma-Fuser Square Thermally Powered VAV Diffuser

MBS Therma-Fuser Standalone Motorized Swirl VAV Diffuser

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

CONDOR. Supply air ceiling QUICK FACTS

Liebert PDX and PCW Thermal Management Systems

Halton Rex 600 Basic R6B - Active chilled beam

THE EFFECT OF HEAT LOAD ARRANGEMENT ON THE PERFORMANCE OF RADIANT PANELS

DESIGNING MODULAR VAV SYSTEMS

CHILLED BEAM CASSETTE IQ STAR LYRA

HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

High Performance Diesel Fueled Cabin Heater. Abstract

Union County Vocational - Technical Schools Scotch Plains, New Jersey

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

MB Therma-Fuser Standalone Motorized Disc VAV Diffuser

Radiant Exchange in Stratified Environments: Considerations and Challenges for Hourly Energy Simulation of UFAD, DV, and Radiant Cooling Systems

Rittling Induction Units Catalog

Fan Coil Unit CULTRA

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

AHRI Certification Program Scopes - COOLING

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

Safety Standard for Refrigeration Systems

Modular Supply Make-Up Air Unit

DIGITAL CENTRALIZED Section NANOMASKIT

SP METHOD 5320 Issue No: Test method for fire detection systems installed in engine compartments of heavy vehicles

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

INTERNATIONAL STANDARD

C o o l i n g a n d h e a t i n g s y s t e m s

Heat Recovery Units. Heat Recovery 1

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

SEMCO CHILLED BEAMS INDOOR AIR QUALITY AND ENERGY SAVINGS FANLESS FILTERLESS SPACE CONDITIONING

Low GWP Refrigerants for Air Conditioning Applications

Certification Programs, Standards,

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Transcription:

AHRI Standard 1241 (SI) 2016 Standard for Performance Rating of Active Chilled Beams

IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes AHRI Standard 1241(SI)-2014 with Addendum 1. For I-P ratings, see AHRI Standard 1240 (I-P)-2016. Scope of Certification Program and Certified Ratings Please refer to the most current version of the Active Chilled Beams Certification Program Operations Manual (OM) for the Scope of the Certification Program and Certified Ratings. Price $10.00 (M) $20.00 (NM) Printed in U.S.A. Copyright 2016, by Air-Conditioning, Heating, and Refrigeration Institute Registered United States Patent and Trademark Office

TABLE OF CONTENTS SECTION PAGE Section 1. Purpose... 1 Section 2. Scope... 1 Section 3. Definitions... 1 Section 4. Classifications... 3 Section 5. Standard Equipment... 3 Section 6. Test Requirements... 3 Section 7. Rating Requirements... 4 Section 8. Minimum Data Requirements for Published Ratings... 4 Section 9. Marking and Nameplate Data... 7 Section 10. Conformance Conditions... 7 TABLES Table 1. Sound Power Level Rating Tolerances... 4 APPENDICES Appendix A. References Normative... 8 Appendix B. References Informative... 8 Appendix C. Method of Testing Water Pressure Drop - Normative... 9 FIGURES FOR APPENDICES Figure C1. Measuring Apparatus for Water Pressure Drop... 10

PERFORMANCE RATING OF ACTIVE CHILLED BEAMS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to provide, for Active Chilled Beams: definitions; classifications; standard equipment; testing requirements; rating requirements; minimum data requirements for published ratings; marking and nameplate data; and voluntary conformance conditions. Section 2. Scope 2.1 This standard applies to Active Chilled Beams as defined in Section 3, including Multi-service Active Chilled Beams and Room Air Induction Units. 2.2 Exclusions. 2.2.1 This standard does not apply to Active Chilled Beams employing volatile-refrigerant coils, condensing coils, or steam coils. 2.2.2 This standard does not apply to Passive Chilled Beams. Section 3. Definitions All terms in this document will follow the standard industry definitions in the ASHRAE Terminology website (https://www.ashrae.org/resources--publications/free-resources/ashrae-terminology), unless otherwise defined in this section. 3.1 Active Chilled Beam. An air induction and diffusion device which introduces conditioned air for the purposes of temperature and/or humidity control. Primary Air is delivered through a series of Nozzles, which induces and conditions Secondary Air through a unit mounted coil. 3.1.1 Multi-service Active Chilled Beam. A chilled beam that incorporates space services other than cooling such as lighting. This type of Active Chilled Beam is usually customized to meet specific project requirements. 3.1.2 Room Air Induction Unit. A type of Active Chilled Beam that requires more than 375 Pa of inlet static pressure to operate. 3.2 Air-induction Process. The process by which a jet of Primary Air induces Secondary Air through the coil. 3.2.1 Primary Air. Air delivered through the Nozzle(s) of an Active Chilled Beam. 3.2.2 Secondary Air. Air induced through the coil of an Active Chilled Beam. 3.2.3 Supply Air. Supply air is the mixture of Primary Air and Secondary Air that is discharged to the space by the Active Chilled Beam. 3.2.4 Nozzle. An air flow opening in the Plenum which discharges a jet of Primary Air via the Air-induction Process. 3.2.5 Plenum. An air compartment under positive pressure, and consisting of inlet(s) and Nozzle(s) for Primary Air. Also referred to as a Plenum Chamber 3.2.6 Induction Ratio. The ratio of the volumetric flow rate of Secondary Air to Primary Air. 3.2.7 Air Outlets and Inlets. Openings for the delivery or induction of air. 3.2.7.1 Supply Air Outlet. An opening for the delivery of supply air from the Active Chilled Beam unit. 1

3.2.7.2 Induced Air Inlet. An opening through which Secondary Air is induced into the Active Chilled Beam. 3.2.8 Standard Air. Air weighing 1.204 kg/m 3 which approximates dry air at 21.1 C and at a barometric pressure of 101 kpa of mercury. 3.2.9 Reference Air Temperature. Average air temperature of the induced air on the inlet side of the cooling coil(s), measured as prescribed in ANSI/ASHRAE Standard 200. 3.3 Octave Band. A band of sound covering a range of frequencies such that the highest is twice the lowest. The Octave Bands used in this standard are those defined in ANSI/ASA Standard S1.11. 3.4 Passive Chilled Beam. A cooled element or coil, fixed in, above or under a ceiling that sensibly cools through natural convection using buoyancy driven air flow. The cooling media in the coil is water. 3.5 Product Line. A family of units of common basic design, consisting of a set of Models, and a progression of Sizes. 3.5.1 Model. The style or structure of the Active Chilled Beam relative to the configuration of coils, Nozzles, and Air Outlets and Inlets as typified by the discharge pattern common to all Sizes. A given Model may have different Nozzle arrangements, Air Outlets and Inlets, coil configurations and Sizes. 3.5.2 Size. A measurement relative to the nominal length and width of the coil. 3.6 Published Rating. A statement of the assigned values of those performance characteristics, under stated rating conditions, by which a unit may be chosen to fit its application. These values apply to all units of a particular Model and Size produced by the same manufacturer. 3.6.1 Standard Ratings. A rating based on tests performed at Standard Rating Conditions. 3.6.2 Application Rating. A rating at other than Standard Rating Conditions; such other rating conditions are referred to as Application Rating Conditions. 3.7 Sensible Cooling Capacity. Capacity associated with a reduction in dry-bulb temperature, W. 3.8 "Shall" or "Should". "Shall" or "should" shall be interpreted as follows: 3.8.1 Shall. Where "shall" or "shall not" is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. 3.8.2 Should. "Should" is used to indicate provisions which are not mandatory but which are desirable as good practice. 3.9 Sound Power Level. Ten times the logarithm to the base ten of the ratio of the sound power radiated by the source to a reference sound power, expressed in decibels (db). The reference sound power used in this standard is 1 picowatt (pw). 3.10 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.10.1 Standard Rating Conditions. Rating Conditions used as the basis of comparison for performance characteristics. 3.11 Throw. Horizontal or vertical axis distance an airstream travels after leaving an air outlet before the stream velocity is reduced to a specific terminal value. 2

Section 4. Classifications 4.1 Active Chilled Beams are classified according to the following Product Lines: 4.1.1 Single or Multiple Discharge Openings. 4.1.2 Method of Secondary Air Intake. 4.1.2.1 Direct Type. where the Induced Air Inlet is located in the room (Secondary Air is induced from the conditioned space). 4.1.2.2 Indirect Type. where the Induced Air Inlet is located outside the room (Secondary Air is induced from the conditioned space via the return air Plenum). 4.1.3 Mounting Type. 4.1.3.1 Exposed mount or surface mount. 4.1.3.2 Modular (ceiling or drywall integrated). 4.1.4 Operating Inlet Static Pressure. 4.1.4.1 Less than or equal to 375 Pa of inlet static pressure. 4.1.4.2 More than 375 Pa of inlet static pressure. Section 5. Standard Equipment 5.1 Equipment. An Active Chilled Beam shall include the following as standard equipment: 5.1.1 Plenum 5.1.2 Nozzle(s) 5.1.3 Cooling, or cooling and heating, coil(s) 5.1.4 Static pressure port(s) 5.1.5 Supply Air Outlet(s) 5.1.6 Induced air opening Section 6. Test Requirements 6.1 Active Chilled Beams, as described in Section 5, shall be tested for rating in accordance with the provisions set forth in ANSI/ASHRAE Standard 200, except as noted in Appendix C. 3

Section 7. Rating Requirements 7.1 Standard Ratings. Standard Ratings shall be established at the Standard Rating Conditions specified in Section 7.2 and shall be expressed in terms of rounded to the nearest 10 W, and in terms of the flow of Primary Air in liters per second (standard L/s) rounded off to the nearest 1 standard L/s. 7.2 Standard Rating Conditions. Standard Ratings shall be determined from tests, using the methods of testing set forth in ANSI/ASHRAE Standard 200. 7.3 Application Rating Conditions. Application ratings shall permit selection of units for at least a range of conditions commonly encountered, and shall be based on corresponding ranges of the parameters listed in Section 8. 7.4 Tolerances. To comply with this standard, Published Ratings shall be based on data obtained in accordance with the provisions of Sections 8 of this standard, and shall be such that any production chilled beams, when tested, will meet these ratings within the following tolerances: 7.4.1 Water flow rate shall be greater than or equal to 95% of the rating. 7.4.2 Water pressure drop shall be no greater than 110% of the rating or 3 kpa above the rating, whichever is greater. 7.4.3 Water coil capacity shall be greater than or equal to 95% of the rating. 7.4.4 Primary Air flow rate shall be less than or equal to 105% of the rating. 7.4.5 Induced air flow rate shall be greater than or equal to 90% of the rating. 7.4.6 Discharge air throw distance shall be within 20% or 30 cm of the rating whichever is greater. 7.4.7 Sound Power Levels shall not exceed the published values in each Octave Band by more than the rating tolerance shown In Table 1. Table 1. Sound Power Level Rating Tolerances Octave Band Octave Band Center Frequencies, Hz Rating Tolerance, db 2 125 6 3 250 4 4 500 3 5 1000 3 6 2000 3 7 4000 3 Section 8. Minimum Data Requirements for Published Ratings 8.1 Published Ratings. Published Ratings shall consist of Standard Ratings. Application Ratings may be published in addition to Standard Ratings. Wherever Application Ratings are published or printed, they shall include or be accompanied by the Standard Rating, clearly designated as such. Application Ratings shall include the information contained in Section 8.3 and shall clearly define the pertinent conditions as indicated in Section 8.4. 8.2 Standard Ratings. Standard Ratings shall consist of at least the following information, obtained at Standard Rating Conditions: 8.2.1 Primary Air flow rate, standard L/s 8.2.2 Primary Air temperature (isothermal to Reference Air Temperature), 24 C 8.2.3 Entering water temperature (cooling), 14 C 4

8.2.4 Minimum Primary Air pressure drop, reported value, rounded to 25 Pa. At this condition, also include the following information: 8.2.4.1 Water coil capacity, reported, W 8.2.4.2 Induced air flow rate, standard L/s 8.2.4.3 Leaving water temperature (reported), C 8.2.4.4 Water flow rate (adjusted to achieve mean water temperature differential of 8 K, relative to Reference Air Temperature), L/s 8.2.4.5 Water pressure drop (reported), kpa 8.2.4.6 Supply Air throw distance at 0.5 m/s (with Supply Air at isothermal conditions relative to the test room to be determined using ANSI/ASHRAE Standard 70 and air volume to be at manufacturer supplied value for Primary Air), m 8.2.4.7 Sound generation (combined radiated and discharge sound) by Octave Bands 2 to 7. Air volume to be at manufacturer s supplied value for Primary Air. 8.2.5 Maximum Primary Air pressure drop, reported value, rounded to 25 Pa. At this condition, also include the following information: 8.2.5.1 Water coil capacity, reported, W 8.2.5.2 Induced air flow rate, standard L/s 8.2.5.3 Leaving water temperature, reported value C 8.2.5.4 Water flow rate, L/s, adjusted to achieve mean water temperature differential of 8 K, relative to reference air temperature 8.2.5.5 Water pressure drop, reported, kpa 8.2.5.6 Supply Air throw distance at 0.5 m/s (with Supply Air at isothermal conditions relative to the test room to be determined using ANSI/ASHRAE Standard 70 and air volume to be at manufacturer supplied value for Primary Air), m 8.2.5.7 Sound generation (combined radiated and discharge sound) by Octave Bands 2 to 7. Air volume to be at manufacturer s supplied value for Primary Air. 8.2.6 Primary Air pressure drop, 125 Pa. At this condition, also include the following information: 8.2.6.1 Water coil capacity, reported, W 8.2.6.2 Induced air flow rate, standard L/s 8.2.6.3 Leaving water temperature (reported), C 8.2.6.4 Water flow rate (adjusted to achieve mean water temperature differential of 8 K, relative to Reference Air Temperature), L/s 8.2.6.5 Water pressure drop (reported), kpa 8.2.6.6 Supply Air throw distance at 0.5 m/s (with Supply Air at isothermal conditions relative to the test room to be determined using ANSI/ASHRAE Standard 70 and air volume to be at manufacturer supplied value for Primary Air), m 5

8.2.6.7 Sound generation (combined radiated and discharge sound) by Octave Bands 2 to 7. Air volume to be at manufacturer s supplied value for Primary Air. 8.3 Published Application Ratings. Published Application Ratings shall consist of at least the following information: 8.3.1 Primary Air flow rate, standard L/s 8.3.2 Primary Air temperature, C 8.3.3 Dew point temperature of room and Primary Air, C 8.3.4 Primary Air pressure drop, Pa 8.3.5 Room air temperature (induced to the beam for cooling), C 8.3.6 Water coil sensible capacity, W 8.3.7 Entering water temperature (cooling), C 8.3.8 Leaving water temperature, C 8.3.9 Water flow rate, L/s 8.3.10 Water pressure drop, kpa 8.3.11 Supply Air throw distance, 0.5 m/s with Supply Air at isothermal conditions relative to the test room to be determined using ANSI/ASHRAE Standard 70. Air volume to be at manufacturer supplied value for Primary Air. 8.3.12 Supply Air temperature, C 8.3.13 Sound generation (combined radiated and discharge sound) by Octave Bands 2 to 7. 8.3.14 Total Sensible Cooling Capacity, W 8.3.15 Sensible water coil energy per unit volume of Primary Air, W/standard L/s 8.3.16 Induced air flow rate, standard L/s 8.3.17 Optional published Application Ratings may include: 8.3.17.1 Induction Ratio 8.3.17.2 Supply air throw distance at other manufacturer-specified m/s (with Supply Air at isothermal conditions relative to the test room to be determined using ANSI/ASHRAE Standard 70 and air volume to be at manufacturer supplied value for Primary Air), m 8.4 Published Rating Data. Published Ratings shall include drawings indicating essential dimensions, including: 8.4.1 The length, height and width of the unit 8.4.2 Nozzle type 8.4.3 Size and locations of inlet(s) for Primary Air 8.4.4 Size and location of piping 6

As a minimum, Published Ratings shall include all Standard Ratings. All claims to ratings within the scope of this standard shall include the statement Rated in accordance with AHRI Standard 1241 (SI). All claims to ratings outside the scope of this standard shall include the statement Outside the scope of AHRI Standard 1241 (SI). Wherever Application Ratings are published or printed, they shall include a statement of the conditions at which the ratings apply. Section 9. Marking and Nameplate Data 9.1 Model Identification. The nameplate on each Active Chilled Beam shall include sufficient Model and Size identification to correlate with published data, literature and any other advertising issued by the manufacturer. 9.2 Marking and Nameplate Data. As a minimum, the nameplate shall display the manufacturer s name and Model designation. Section 10. Conformance Conditions 10.1 Conformance. While conformance with this standard is voluntary, conformance shall not be claimed or implied for products or equipment within the standard s Purpose (Section 1) and Scope (Section 2) unless such product claims meet all the requirements of the standard and all of the testing and rating requirements are measured and reported in complete compliance with the standard. Any product that has not met all the requirements of the standard cannot reference, state, or acknowledge the standard in any written, oral, or electronic communication. 7

APPENDIX A. REFERENCES NORMATIVE A1 Listed here are all standards, handbooks and other publications essential to the formation and implementation of the standards. All references in this appendix are considered as part of the standard. A1.1 ANSI/ASA Standard S1.11-2014, Electroacoustics - Octave-band and Fractional-octave-band Filters - Part 1: Specifications (a nationally adopted international standard, Acoustical Society of America, Suite 300, 1305 Walt Whitman Road, Melville, NY 11747-4300, U.S.A. A1.2 ANSI/ASHRAE Standard 70-2006, Method of Testing the Performance of Air Outlets and Air Inlets, 2006, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, N.E., Atlanta, GA 30329, U.S.A. A1.3 ANSI/ASHRAE Standard 200-2015 with addendum a, Methods of Testing Chilled Beams, 2015, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, N.E., Atlanta, GA 30329, U.S.A. A1.4 ASHRAE Terminology, https://www.ashrae.org/resources--publications/free-resources/ashrae-terminology, 2016, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, N.E., Atlanta, GA 30329, U.S.A. APPENDIX B. REFERENCES INFORMATIVE B1 Listed here are standards, handbooks, and other publications which may provide useful information and background but are not considered essential. References in this appendix are not considered part of the standard. None. 8

APPENDIX C. METHOD OF TESTING WATER PRESSURE DROP - NORMATIVE C1.1 The temperatures and pressures of water entering and leaving the chilled beam shall be measured by the apparatus as illustrated in Figure C1. The connecting piping shall be the same size as the chilled beam supply and return connections. C1.2 Temperature measuring instruments shall be placed so as to measure the temperature of the water entering and leaving the coil. The liquid lines shall be insulated at and adjacent to the temperature measuring instruments. Suitable insulation having an RSI of 0.79 m 2 C/W or greater shall be applied from the unit under test to at least 150 mm upstream of the inlet temperature sensor and 150 mm downstream of the outlet temperature sensor. Temperature sensor stems shall be insulated. To minimize possible temperature stratification, appropriate mixers, such as "static mixers," shall be inserted in the inlet and outlet liquid lines upstream from the temperature measuring instruments. Alternatively, two close-coupled 90 elbows just upstream of the temperature measuring instruments can serve as mixers provided that the water velocity at the mixing section is not below 0.3 m/s. C1.3 Suitable means shall be provided for determining the liquid absolute pressure entering the coil and the liquid pressure drop through the coil and measurement apparatus as shown in Figure C1. The piezometer rings shall be located and constructed in accordance with the dimensions shown in Figure C1. Pressure taps may be used in lieu of piezometer rings. The test setup measurement of pressure drop between piezometer rings or pressure taps shall be reduced by the pressure drop of the total length of pipe between the piezometer rings or pressure taps and the coil. The piping loss shall be determined by calibration of the measurement apparatus. The pressure drop in the test measurement apparatus, including any pipe between the coil and the measuring devices, at the test flow shall be calculated and subtracted from the measurement. This piping loss shall be determined by calibration of the test apparatus or by calculation of pressure drop based on type of material used for the pipe. 9

10 Figure C1. Measuring Apparatus for Water Pressure Drop