GAS 15 L Professional

Similar documents
ALS 25. Robert Bosch GmbH Power Tools Division Leinfelden-Echterdingen Germany. F 016 L (2011.

Rotak 32 R. Robert Bosch GmbH Power Tools Division Leinfelden-Echterdingen Germany. F 016 L (2010.

ALS Robert Bosch GmbH Power Tools Division Leinfelden-Echterdingen GERMANY. F 016 L (2014.

GBH 2-20 D Professional

GAS 35 L AFC Professional

AXT 22 D 25 D 23 TC 25 TC. Robert Bosch GmbH Power Tools Division Leinfelden-Echterdingen Germany.

GBS 75 AE Professional

Robert Bosch GmbH Power Tools Division Leinfelden-Echterdingen Germany S04 ( ) T / 303 XXX

PHG DCE. Robert Bosch GmbH Power Tools Division Leinfelden-Echterdingen Germany.

AXT. Rapid 2000 Rapid Robert Bosch Power Tools GmbH Stuttgart GERMANY. F 016 L (2014.

PFS

TE DRS-M. Bedienungsanleitung Operating instructions Mode d emploi Manual de instrucciones Istruzioni d uso Gebruiksaanwijzing Bruksanvisning

VC4210L

GAS 55 M AFC Professional

IT Istruzioni di montaggio e d'uso EN Instruction on mounting and use DE Montage- und Gebrauchsanweisung FR Prescriptions de montage et mode d emploi

Vacuum cleaner Instruction manual

TE DRS-S. Printed: Doc-Nr: PUB / / 000 / 00

F. Originalbetriebsanleitung Original instructions Notice originale Manual original

English 6. Copyright DEWALT

IT Istruzioni di montaggio e d'uso EN Instruction on mounting and use DE Montage- und Gebrauchsanweisung FR Prescriptions de montage et mode d emploi

DV7215EL DV1015EL DV1415EL DV1815EL.

Operating instructions in the back PV9625N PV1225NB PV1225NPM PV1425N PV1825N PV1825NR

Automatic Milk Frother / Milchschäumer

Operating instructions in the back. SVFV3250L SVFV3250LR

SANITATION TOILETS. Matka-wc Käyttöohje Переносной туалет Инструкция по эксплуатации Toaleta przenośna Instrukcja obsługi...

TE DRS-4-A. he ar. Instrukcija Kasutusjuhend IНСТРУКЦIЯ З ЕКСПЛУАТАЦIЇ. ja ko zh cn. Printed: Doc-Nr: PUB / / 000 / 01

NV3610N NV7210N NV9610N.

2 000W CYCLONIC BAGLESS VACUUM

Blower UB1100 UB1101 INSTRUCTION MANUAL

Operating Instructions

PFS. Robert Bosch Power Tools GmbH Stuttgart GERMANY A 1LB ( ) PS / 251 EURO

Compressor Cooler Pro

SAFETY AND OPERATING MANUAL

EFG540G/A EN DE FR NL ES PT SL EL TR BG

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

DEUTSCH Gebrauchsanweisung Seite 4 ENGLISH Instructions for use Page 11 FRANÇAIS Mode d emploi Page 18 NEDERLANDS Gebruiksaanwijzing Pagina 25

Ireland. Australia. New Zealand

IVB 3-M/5-M/7-M. Operating Instructions Betriebsanleitung Notice d utilisation Gebruiksaanwijzing Istruzioni sull uso Driftsinstruks Bruksanvisning

DUST EXTRACTOR INSTRUCTION MANUAL. 550W (3/4 HP) INDUCTION MOTOR 1850W AUTOMATIC POWER OUTLET 65L COLLECTION BAG ø100mm X 2.

IT Istruzioni di montaggio e d'uso EN Instruction on mounting and use DE Montage- und Gebrauchsanweisung FR Prescriptions de montage et mode d emploi

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

TE 300-AVR. English Français Español Português

SPECIFICATIONS MODEL NO. OZDE1015WA

SVJ520BFSP

GWC1815 GWC1820PC.

COOKER HOOD DUNSTABZUGSHAUBE HOTTE DE CUISINE AFZUIGKAP CAMPANA EXAUSTOR CAPPA SPISFLÄKT KJØKKENVIFTE LIESITUULETIN EMHÆTTE PLIIDIKUMM DANGTIS

USER GUIDE LET S GO. Bagless Cylinder. dirtdevil.com.au. Dirt Devil Service Line AU: / NZ:

COOKER HOOD DUNSTABZUGSHAUBE HOTTE DE CUISINE AFZUIGKAP CAMPANA EXAUSTOR CAPPA SPISFLÄKT KJØKKENVIFTE LIESITUULETIN EMHÆTTE PLIIDIKUMM DANGTIS

Combivac Operating Instructions Combivac

IT Istruzioni di montaggio e d'uso EN Instruction on mounting and use DE Montage- und Gebrauchsanweisung FR Prescriptions de montage et mode d emploi

DUST EXTRACTOR MODEL No: CDE1000

Tassenwärmer / Cup warmer

TE 2 TE 2-M TE 2-S. English Français Español Português

English. Kundendienst und Anwendungsberatung. General Power Tool Safety Warnings. Entsorgung. Work area safety. Electrical safety WARNING.

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

AUSTRALIA PAD1200-XE NEW ZEALAND

Electric kettle Dear Customer Connection to the mains supply Familiarisation Important safety instructions

MV 4 MV 4 Premium. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Ireland. Australia. New Zealand

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

English (Original instructions) 5

ORIGINAL OPERATING INSTRUCTIONS ASH VACUUM CLEANER / 18L

User Guide Vax Careline: AU: NZ:

TE DRS-Y. Lietošanas pamācība Instrukcija Kasutusjuhend IНСТРУКЦIЯ З ЕКСПЛУАТАЦIЇ Пайдалану бойынша басшылық. kk ja ko zh cn

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

TE 7-C. Deutsch English. Русский. Slovenščina. Hrvatski. Български Română Türkçe. Українська Қазақ 日本語 한국어 繁體中文

Ireland Australia New Zealand

Australia. New Zealand

Smoke Alarm FERION 1000 O

MULTI - CYCLONIC VACUUM CLEANER VCC 7070

Ireland. Australia. New Zealand

MV 2. Operating Instructions. Before first use of the unit read these operating instructions and act in accordance with them.

Kasutusjuhend Pliidikumm DE. Libretto di uso Cappa. Lietošanas pamācība Kapuce FR. Användningshandbok Spisfläkt. Bruksveiledning Kjøkkenvifte

Work-Shed Vac 1100 Watt

Get Cleaning... User Guide Vax Service line AU: NZ: Bagless Cylinder. VPPST1600/ VPPAT1600/ VPP1600P

Air Reach Upright VACUUM CLEANER

AirPet User Guide VCAP1500

Standmixer 4 Blender 10 Mixer 15 Blender 21 Batidora 26 Frullatore 31 Blender 36 Mixer 41 Sekoitin 46 Mikser 51 Μπλέντερ 56 Блендер стационарный 62

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Power 4. User Guide. HC85-P4-ZA hoover.za.com

DOMINATOR IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

ShowerSelect S

WET & DRY VACUUM 1250W 12L WARRANTY INSTRUCTION MANUAL SPECIFICATIONS VWD-1212 WHAT S IN THE BOX

FlipOut CORDLESS HAND VAC

PondoPress 10000, 15000

TE 2 TE 2-M TE 2-S English

CONTENTS 1. RECOMMENDATIONS AND SUGGESTIONS USE MAINTENANCE CONTROLS LIGHTING...6

GB Operating instructions

User Guide Vax Careline: AU: NZ:

AERO 21 AERO 21 INOX C

Ultima Pet Plus Instruction Manual

Your Blast Vac Pro. Your Blast Vac Pro

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

Designed in the UK. User Guide. vax.com.au

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

EHG2000. ORIGINAL INSTRUCTIONS Heat Gun

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

PerformAir Profile bagged cylinder vacuum cleaner

Toplock Indoor. Originalbedienungsanleitung

Transcription:

OBJ_DOKU-23628-001.fm Page 1 Thursday, January 13, 2011 2:33 PM Robert Bosch GmbH Power Tools Division 70745 Leinfelden-Echterdingen Germany www.bosch-pt.com GAS 15 L Professional 1 609 929 X19 (2011.01) O / 183 UNI de Originalbetriebsanleitung en Original instructions fr Notice originale es Manual original pt Manual original it Istruzioni originali nl Oorspronkelijke gebruiksaanwijzing da Original brugsanvisning sv Bruksanvisning i original no Original driftsinstruks fi Alkuperäiset ohjeet el Πρωτότυπο οδηγιών χρήσης tr Orijinal işletme talimat pl Instrukcja oryginalna cs Původní návod k používání sk Pôvodný návod na použitie hu Eredeti használati utasítás ru Оригинальное руководство по эксплуатации uk Оригінальна інструкція з експлуатації ro Instrucţiuni originale bg Оригинална инструкция sr Originalno uputstvo za rad sl Izvirna navodila hr Originalne upute za rad et Algupärane kasutusjuhend lv Instrukcijas oriģinālvalodā lt Originali instrukcija ar fa

OBJ_BUCH-1321-001.book Page 9 Thursday, January 13, 2011 2:35 PM English 9 Safety Notes Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save these instructions. Do not vacuum dust from beech or oak wood, masonry dust or asbestos. These materials are considered carcinogenic. Use the vacuum cleaner only after having received sufficient information on the usage of the vacuum cleaner, the materials to be vacuumed and their safe disposal. A thorough introduction reduces operating errors and injuries. Children or persons that, owing to their physical, sensory or mental limitations or to their lack of experience or knowledge, are not capable of securely operating the vacuum cleaner, may only use this vacuum cleaner under supervision or after having been instructed by a responsible person. Otherwise, there is danger of operating errors and injuries. The vacuum cleaner is suitable for vacuuming dry materials and, by taking suitable measures, also for vacuuming liquids. The penetration of liquids increases the risk of an electric shock. Do not vacuum inflammable or explosive fluids; for example, benzene, oil, alcohol, solvents. Do not vacuum hot or burning dust. Do not operate the machine in rooms where the danger of an explosion exists. The dusts, vapours or fluids can ignite or explode. Use the socket only for the purposes specified in of the operating instructions. Switch the vacuum cleaner off immediately as soon as foam or water comes out, and empty the container. Otherwise, the vacuum cleaner can become damaged. The vacuum cleaner may only be used and stored indoors. The penetration of rain or moisture into the vacuum cleaner lid increases the risk of an electric shock. Clean the float at regular intervals, and check it for damage. Otherwise, its function can be impaired (see Fig. 14, page 179). When operating the vacuum cleaner in damp environments, use a residual current device (RCD). Using a residual current device (RCD) reduces the risk of an electric shock. Connect the vacuum cleaner to a properly earthed mains supply. The socket outlet and the extension cable must have an operative protective conductor. Before each use, check the vacuum cleaner, cable and plug. Do not use the vacuum cleaner when defects are detected. Do not open the vacuum cleaner yourself and have it repaired only by qualified personnel using original spare parts. Damaged vacuum cleaner, cables and plugs increase the risk of an electric shock. Do not drive over, crush or stretch the cable. Do not pull the cable to unplug the plug from the socket outlet or to move the vacuum cleaner. Damaged cablesincrease the risk of an electric shock. During work breaks, when not in use or when working on the machine (e. g. changing tool inserts, repairs, cleaning, adjustments), pull the mains plug. This safety measure prevents accidental starting of the vacuum cleaner. Provide for good ventilation at the working place. Supervise children. This will ensure that children do not play with the vacuum cleaner. Have the vacuum cleaner repaired only through qualified specialists and only using original spare parts. This ensures that the safety of your vacuum cleaner is maintained. Bosch Power Tools 1 609 929 X19 (13.1.11)

OBJ_BUCH-1321-001.book Page 10 Thursday, January 13, 2011 2:35 PM 10 English The vacuum cleaner contains materials that are hazardous to one s health. Have the emptying and maintenance, incl. the disposal of dust-collection containers, carried out only by specialists. Appropriate protective equipment is required. Do not operate the vacuum cleaner without the complete filter system. Otherwise there is danger to your own health. Before restarting, check the proper condition of the vacuum hose. When doing this, leave the vacuum hose mounted to the vacuum cleaner to avoid dust from coming out. Otherwise, you could possible inhale dust. Do not use the vacuum cleaner as a seat. The vacuum cleaner could become damaged. Use the mains cable and the vacuum hose carefully. Other persons could be harmed. Do not clean the vacuum cleaner with a water jet pointed directly at it. The penetration of water into the vacuum cleaner lid increases the risk of an electric shock. Products sold in GB only: Your product is fitted with an BS 1363/A approved electric plug with internal fuse (ASTA approved to BS 1362). If the plug is not suitable for your socket outlets, it should be cut off and an appropriate plug fitted in its place by an authorised customer service agent. The replacement plug should have the same fuse rating as the original plug. The severed plug must be disposed of to avoid a possible shock hazard and should never be inserted into a mains socket elsewhere. Products sold in AUS and NZ only: Use a residual current device (RCD) with a rated residual current of 30 ma or less. Additional Safety and Working Instructions Observe the mains voltage! The voltage of the power source must correspond with the data on the type plate of the vacuum cleaner. For dry vacuuming, a dust bag should be inserted. When using a dust bag, the folded filter remains unclogged longer, the vacuuming performance is maintained longer, and the disposal of dust is made easier. Remove the dust bag and empty the container before wet vacuuming. The vacuum cleaner has a blower function. Do not blow the outgoing air randomly in enclosed areas. Use the blower function only with the a clean hose. Dusts can be hazardous to one s health. After vacuuming, remove the folded filter to prevent the forming of mould and allow it to dry thoroughly; especially before using it for dry vacuuming. Operate the vacuum cleaner only with the folded filter mounted. A socket outlet with earthing contact is integrated in the vacuum cleaner. An external power tool can be connected there. The vacuum cleaner is automatically put into operation via the power tool. Observe the maximal allowable load of the connected power tool. The vacuum cleaner may not be used as a water pump. The vacuum cleaner is intended for vacuuming air and water mixtures. Wipe out the container from time to time with a commercially available, non-scouring cleaning agent, and allow it to dry. Symbols The following symbols are important for reading and understanding the operating instructions. Please take note of the symbols and their meaning. The correct interpretation of the symbols will help you to use the vacuum cleaner in a better and safer manner. Symbol Meaning GAS 15 L: All-Purpose Vacuum Cleaner Article number 1 609 929 X19 (13.1.11) Bosch Power Tools

OBJ_BUCH-1321-001.book Page 11 Thursday, January 13, 2011 2:35 PM English 11 Symbol Meaning Symbol Meaning CAUTION Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Prohibited action Permitted action Next step of action Vacuum cleaners of dust category L according to IEC/ EN 60335-2-69 for vacuuming materials > 1 mg/m 3 that are hazardous to one s health. P 1 f Rated power input Frequency Container volume (gross) Net volume Do not use the vacuum cleaner as a seat or stepladder Vacuum, max. Airflow, max. Before any work on the vacuum cleaner itself, pull the mains plug from the socket outlet Wear ear protection. L Suction capacity Surface of folded filter Dust filter category of vacuum cleaner Degree of protection Wear a dust respirator. Movement direction /I Symbol for protection class I (with protective conductor) Weight according to EPTA-Procedure 01/2003 BIA test certificate number for filter/vacuum cleaner Reaction direction Apply strength for the workstep. Switching On Switching Off Remote automatic switching L pa K Delivery Scope Sound pressure level Uncertainty All-Purpose Vacuum Cleaner (see figure 1) A complete overview of accessories can be found in our accessories program. Bosch Power Tools 1 609 929 X19 (13.1.11)

OBJ_BUCH-1321-001.book Page 12 Thursday, January 13, 2011 2:35 PM 12 English Intended Use The machine is intended for collection, vacuuming, conveying and separation of non-flammable dry dusts that correspond with the general exposition limit value of > 1 mg/m 3, such as dusts of mineral materials with aluminium hydroxide, graphite dusts, aluminium dusts, paper dusts, soot dusts, powder paint dusts, polyurethane dusts, GFRP dusts based on epoxy resin (see manufacturer s data sheet on safety), CFP dusts based on epoxy resin (see manufacturer s data sheet on safety), varnish dusts without carcinogenic components, wood dusts and non-flammable liquids and water-air mixtures. The vacuum cleaner is dust-technically checked and corresponds with dust category L. The vacuum cleaner has a blower function, e. g. for drying surfaces. The vacuum cleaner has a socket outlet with remote automatic switching for connection of a power tool with extraction function. It is suitable for the increased demands of industrial usage, as required in trades, industry and workshops. The vacuum cleaner may generally not be used in rooms where the danger of an explosion exists. Technical Data The technical data of the machine are listed in the Table on page 166. The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries, these values can vary. Please observe the article number on the type plate of your vacuum cleaner. The trade names of the individual vacuum cleaners may vary. Declaration of Conformity We declare under our sole responsibility that the product described under Technical data is in conformity with the following standards or standardization documents: EN 60335 and the directives 2006/42/EC, 2004/108/EC including their amendments. Technical file at: Robert Bosch GmbH, PT/ESC, D-70745 Leinfelden-Echterdingen Dr. Egbert Schneider Senior Vice President Engineering Robert Bosch GmbH, Power Tools Division D-70745 Leinfelden-Echterdingen 09.12.2010 Noise Information Dr. Eckerhard Strötgen Head of Product Certification The measured values of the machine are listed in the table on page 166. Measured values determined according to EN 60704. Mounting and Operation Action Figure Page Removing accessories 1 167 Mounting the hose holder 2 167 Inserting a dust bag 3 168 Inserting a disposal bag 4 169 Disposing of the dust bag 5 169 Mounting the hose 6 170 Transport position 7 171 1 609 929 X19 (13.1.11) Bosch Power Tools

OBJ_BUCH-1321-001.book Page 13 Thursday, January 13, 2011 2:35 PM English 13 Action Figure Page Switching On and Off 8 171 Connecting a power tool to the vacuum cleaner; remote automatic switching 9 172 174 Regulating the airflow 10 174 Blower function 11 175 Semi-automatic filter cleaning 12 176 Changing the folded filter 13 177 178 Cleaning the float 14 179 181 Selecting accessories 182 Troubleshooting Switch the vacuum cleaner off immediately as soon as foam or water comes out, and empty the container. Otherwise, the vacuum cleaner can become damaged. The vacuum cleaner is equipped with a float. When the maximum filling height is reached, the suction capacity is reduced. Set the On/Off switch to position 0 and empty the container. If the suction force is so high that the connected power tool adheres too firmly against the working surface, regulate the airflow. When the vacuum performance decreases, activate the semi-automatic filter cleaning. Maintenance and Cleaning For safe and proper working, always keep the vacuum cleaner and ventilation slots clean. A dust-technical inspection is to be carried out at least once every year by the manufacturer or an instructed person, e. g. for damage of the filter, tightness against leakage of the vacuum cleaner and function of the control/monitoring unit. For category L vacuum cleaners that were in contaminated environments, the exterior as well as all machine parts should be cleaned or treated with sealants. When performing maintenance and repair work, all contaminated components that cannot be cleaned to satisfactory must be disposed of. Such components must be disposed of in impermeable plastic bags conforming with the valid regulations for the disposal of such waste. For maintenance on behalf of the user, the vacuum cleaner must be disassembled, cleaned and maintained as far as feasible, without causing a risk for the maintenance personnel or other persons. Prior to disassembly, the vacuum cleaner should be cleaned in order to prevent any risks. The room/enclosure in which the vacuum cleaner is disassembled should be well ventilated. Wear personal protective equipment during maintenance. After the maintenance, the maintenance area should be cleaned. If the vacuum cleaner should fail despite the care taken in manufacturing and testing procedures, repair should be carried out by an aftersales service centre for Bosch power tools. If the replacement of the supply cord is necessary, this has to be done by Bosch or an authorized Bosch service agent in order to avoid a safety hazard. After-sales Service and Customer Assistance Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts. Exploded views and information on spare parts can also be found under: www.bosch-pt.com Bosch Power Tools 1 609 929 X19 (13.1.11)

OBJ_BUCH-1321-001.book Page 14 Thursday, January 13, 2011 2:35 PM 14 English Our customer service representatives can answer your questions concerning possible applications and adjustment of products and accessories. In all correspondence and spare parts orders, please always include the 10-digit article number given on the type plate of the vacuum cleaner. Great Britain Robert Bosch Ltd. (B.S.C.) P.O. Box 98 Broadwater Park North Orbital Road Denham Uxbridge UB 9 5HJ Tel. Service: +44 (0844) 736 0109 Fax: +44 (0844) 736 0146 E-Mail: boschservicecentre@bosch.com Ireland Origo Ltd. Unit 23 Magna Drive Magna Business Park City West Dublin 24 Tel. Service: +353 (01) 4 66 67 00 Fax: +353 (01) 4 66 68 88 Australia, New Zealand and Pacific Islands Robert Bosch Australia Pty. Ltd. Power Tools Locked Bag 66 Clayton South VIC 3169 Customer Contact Center Inside Australia: Phone: +61 (01300) 307 044 Fax: +61 (01300) 307 045 Inside New Zealand: Phone: +64 (0800) 543 353 Fax: +64 (0800) 428 570 Outside AU and NZ: Phone: +61 (03) 9541 5555 www.bosch.com.au Republic of South Africa Customer service Hotline: +27 (011) 6 51 96 00 Gauteng BSC Service Centre 35 Roper Street, New Centre Johannesburg Tel.: +27 (011) 4 93 93 75 Fax: +27 (011) 4 93 01 26 E-Mail: bsctools@icon.co.za KZN BSC Service Centre Unit E, Almar Centre 143 Crompton Street Pinetown Tel.: +27 (031) 7 01 21 20 Fax: +27 (031) 7 01 24 46 E-Mail: bsc.dur@za.bosch.com Western Cape BSC Service Centre Democracy Way, Prosperity Park Milnerton Tel.: +27 (021) 5 51 25 77 Fax: +27 (021) 5 51 32 23 E-Mail: bsc@zsd.co.za Bosch Headquarters Midrand, Gauteng Tel.: +27 (011) 6 51 96 00 Fax: +27 (011) 6 51 98 80 E-Mail: rbsa-hq.pts@za.bosch.com Disposal The vacuum cleaner, accessories and packaging should be sorted for environmental-friendly recycling. Do not dispose of the vacuum cleaner into household waste! Only for EC countries: According the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment and its implementation into national right, power tools that are no longer usable must be collected separately and disposed of in an environmentally correct manner. Subject to change without notice. 1 609 929 X19 (13.1.11) Bosch Power Tools