ARJENT S2 INSIDE AS IT IS OUTSIDE. AS BRILLIANT. The ARJENT S2 lightbar from Federal Signal v

Similar documents
A L I G H T B A R T H AT S EARNED ITS NAME. INTEGRITY

A WHOLE NEW ANGLE IN SAFETY AND SECURITY VALOR

A WHOLE NEW ANGLE IN SAFETY AND SECURITY VALOR

LED Ultrastar. trobe beacons

Installation and Programming Instructions for the Federal Signal Serial Interface Module

California. Approved LED Products.

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR 53 OHIO STATE HIGHWAY PATROL VISTA LIGHTBAR ( OHPxx)

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR RICOCHET POWERED VISTA STROBE LIGHT ASSEMBLY

HEAVY DUTY DISTRIBUTORS PREFERRED PRODUCTS PROGRAM CONSTRUCTION TOW AND RECOVERY UTILITY DOT/MUNICIPAL

Creating possibilities for you to build a smarter, safer and more confident tomorrow.

AllegiantTM Lightbar. Installation, Maintenance, and Service Manual REV. A Printed in U.S.A. Copyright 2018 Federal Signal Corporation

AllegiantTM Lightbar. Installation, Maintenance, and Service Manual REV. B Printed in U.S.A. Copyright 2018 Federal Signal Corporation

Installation Instructions for the LatitudeTM Solaris Stick Light Models SL8C-xxx

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Model QuadraFlare. Installation and Service Instructions. Warning Lights

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Altman Lighting Spectra Cyc UV 50 Specification

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

E M E R G E N C Y L I G H T I N G

Intelligent Security & Fire Ltd

NU2 Smart Power Supply (SPS) Manual

PREMIUM VISION WARNING SYSTEM (with Slide Switch Control Head)

HD220 Dual Output Programmable Humidity Controller

BEACONS, LIGHTBARS & MINIBARS LED DIRECTIONAL LIGHTS LIGHTING SYSTEMS BACK-UP ALARMS CAMERA SYSTEMS

Photoelectric laser sensors E3C-LDA SERIES. l o n g - d i s t a n c e, a d j u s t a b l e l a s e r b e a m. Advanced Industrial Automation

Intelligent addressable fire alarm control panel

Retroreflective sensor with polarization filter

CIRRUS AIRPLANE MAINTENANCE MANUAL

General Specifications

INFRARED MODULATED BARRIERS

ATS Annunciator - MODBUS

ANTI-COLLISION LIGHT SYSTEM. 400 Candles Red and White Wing & Tail Strobe Lights

SS2000 Software Configuration Manual

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

NFPA 1901 Specification. Lighting Packages

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

New Linear Series DISCONTINUED

SC315 RECTANGULAR RAPID FLASHING BEACON. MUTCD-compliant, pedestrian-activated warning beacon for uncontrolled marked crosswalks

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

M1000 Alarm Annunciator

SiteSentinel itouch Console

460H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 460H TM REMOTE STROBE POWER SUPPLY

Control Panels and Fire Detection Equipment

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

The Amerex Advantage - Quality Experienced Innovation Made in the USA

High Lux Performance White LED MR16 Lamp

Optimal control for superior lighting performance

RS485 MODBUS Module 8AI

TrueAlert Notification Appliances

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection

TC-PLUS Thermal Cyclers

Retroreflective sensor with polarization filter

Optical Preemption & Priority Control Systems

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

INTREPID Buried Cable Perimeter Intrusion Detection System

CLM 422 Series LED Ceiling Luminaire Module - 45Watt

HIDE-A-BLAST HB615X / HB915X INSTALLATION & OPERATION MANUAL IMPORTANT: 6 LED and 9 LED WARNING LIGHT

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

High Intensity LED Strobe Light - 10 Watt - 10~30 Volts DC - Permanent Mount - 14 Strobe Patterns

COMPANY PROFILE. Check out our web site at whelen.com

Dräger Polytron 7000 Fixed gas detector

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

sirens speakers and programmable controls

Laser retro-reflective photoelectric sensor with polarization filter. Dimensioned drawing

and Channel indicator and monitoring unit B Operating Instructions 2.00/

ACCELERATE YOUR CURING TIME

PTE0705 Electric Fence Monitor

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

ICARO. Aircraft Warning Lights GENERAL CATALOGUE

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

JEDI. Powerful recessed linear LED projector. Views

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

sirens speakers and programmable controls

Dräger Polytron 8000 Stationary gas detector (EC)

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

ARCHITECTURAL DIMMING PANEL - MAIN/SECONDARY

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

System controller for cascade control, heating boilers with solar, buffer and pel et control

User Manual LIGHTMEN.COM. Apollo A75050

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

SERIES PSE-690 INSTALLATION & OPERATION MANUAL IMPORTANT: PSE-690 REMOTE STROBE POWER SUPPLY

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Model 4880 Status Output Display Module Manual

Developing UV LED Curing Processes for Converting Applications

SmarTemp Control fx 2.0

ICARO. Aircraft Warning Lights GENERAL CATALOGUE.

Line Isolation Monitor (LIM) LIM2000plus

2005 PRODUCT GUIDE BACK-UP ALARMS LIGHTBARS STROBE, ROTATING & LED BEACONS LIGHTING SYSTEMS

Transcription:

ARJENT S2 AS BRILLIANT INSIDE AS IT IS OUTSIDE. The ARJENT S2 lightbar from Federal Signal

THE ARJENT S2 LIGHTBAR BRIGHTNEW THINKING From the leader in emergency warning technology. SAFER SOLARIS THE BEST AND BRIGHTEST IN LIGHTING TECHNOLOGY Our patent-pending Federal Signal Solaris design features the latest in LED reflector technology for bright and intense off-axis light output. ADDITIONAL FEATURES FOR SAFER OPERATION The Arjent S2 is loaded with additional features such as the adanced micro-processor controller which proides three modes of operation, a library of flash patterns, adjustable alley and takedown lights, front/rear cut-off, dimming and intersection warning. Dimming Proides Additional Officer and Pedestrian Safety The dimming feature can significantly reduce the light output to half its intensity in modes one and two. For officer safety, the dimming feature is not actiated in mode three. Adjustable Alley and Takedown Lights The alley and takedown lights can be adjusted horizontally and ertically to ensure proper isibility. Front Cut-off Rear Cut-off Front and rear cut-off may be used in mode one, two, or three

THE ARJENT S2 LIGHTBAR BRIGHTNEW THINKING From the leader in emergency warning technology. The low profile, elliptical sha off-axis warning than traditio SMARTER ROC SOLID CONSTRUCTION Our patent pending ROC (Reliable Onboard Circuitry ) technology eliminates 85% of potential failure points in the lightbar reducing repair costs and increasing the hours your emergency ehicles stay on the road. ROC with the Micro-processor Controller proides adanced communication between the lightbar and the controller head. Minimal Board-to-Board Connections eliminates about 85% of possible failure points. A printed circuit board in one assembly reduces the number of electrical connections in a lightbar. Solaris optics and cured end caps offer superior LED reflector technology for bright 360-degree coerage, excellent off-axis light output and no dark spots. YESTERDAY S TECHNOLOGY. The most common failure points found in a typical lightbar, as shown below, occur between the connector and its light source; and the lightbar s power source. With older technology each light head typically has at least two, sometimes four, connections per light head. ROC technology reduces the number of parts found in a typical lightbar by approximately 65%

pe complements the Solaris LED technology to proide 360-degree coerage and significantly greater nal linear lightbars. SIMPLER SIMPLE TO CUSTOMIZE AND CONFIGURE The Arjent S2 may be repaired or reconfigured without taking the lightbar off the ehicle which cuts down on costly ehicle down time. Domes or lenses are quickly and easily replaced as needed. 1 Remoe the top dome with only four screws. 2 Disconnect the ROC board by the 22-gauge wire harness. Internal SignalMaster Directional Warning Arjent S2 can be configured for internal Federal Signal SignalMaster control operation. In this mode, an external SignalMaster controller is not required. A simple slide switch actiates the lightbar s internal SignalMaster. While operating in three priority modes, all modules keep sequence with the flash pattern. Once directional warning is selected, the SignalMaster modules oerride the current flash pattern.

ARJENT S2 AND RS485 SYSTEM The RS485 System makes it fast and easy to clone and duplicate patterns from ehicle to ehicle. The function of each indiidual light head can be controlled with the RS485 system. Four default patterns are included for positions 1, 2, 3 and the intersection clearing mode. Arjent S2 lightbars are controlled through a standard RS485 bus connection. Protocol is based on SAE J1708 and J1587 standards. Compact serial interface module is included with eery Arjent S2 lightbar for those ehicles not equipped to accept RS485 bus connections. Built-in SignalMaster directional warning capability is standard with the Arjent S2. SignalMaster patterns can be actiated ia a standard relay switch and do not need a separate directional warning controller. Additional pre-programmed options such as front/rear cut-off, intersection warning, and dimming can easily be programmed into the lightbar operation and cloned from ehicle and ehicle. EASY CONFIGURATION 1 RS485 Adaptor All Arjent S2 lightbars include a serial interface module which is used to program the lightbar s features and functions. Select from default flash patterns or customize your lightbar with 26 newly designed warning patterns. 2 Laptop or PC Cloning of the serial interface module is accomplished with the use of a laptop or desktop and an EPIC programmer, sold separately. 3 Fleet Programming The EPIC USB programmer is used to quickly program lightbars for any size fleet, proiding significant time and cost saings. This is especially important when performing installations oer a large fleet. LED colors are offered in red, blue, white, amber and green. Dome colors are aailable in red, blue, clear and amber.

SMARTER, SIMPLER, AND SAFER DISCOVER THE ARJENT S2 ADVANTAGE To learn more about what the Arjent S2 performance can do for you, call 800-264-3578. FEDERAL SIGNAL S ON-LINE LIGHTBAR CONFIGURATOR IS QUICK AND EASY TO USE. To configure your Arjent S2 36", 44", and 53" lightbars, go to www.fedsig.com. Sae, print, or e-mail your configuration to a Federal Signal Customer Support Representatie or contact your local distributor today. Warning Light Specifications Lighting Option Current Draw Lamp/Technology Reflector Style Solaris S2 LED Takedown Light 1.0 A* Six Gen III high brightness white LEDs Solaris S2 LED Alley Light 1.0 A* Six Gen III high brightness white LEDs Solaris S2 2" Flashing positions 0.5 A* Three Gen III high brightness LEDs Solaris S2 4" Flashing positions 1.0 A* Six Gen III high brightness LEDs Offset, compound-cure, polished spot beam refl ector Offset, compound-cure, polished spot beam refl ector Offset, compound-cure polished refl ector Offset, compound-cure polished refl ector Halogen Takedown Light 3.9 A** bi-pin halogen MR16, 50W 12-degree polished refl ector Halogen Alley Light 2.7 A** bi-pin halogen MR16, 35W 24-degree polished refl ector *Amperage in steady burn mode **Amperage per pair, with fl ashing takedown and alley lights Technical Specifications Model Length Height Width Weight Operating Voltage 36" Arjent S2 36 in (91.4 cm) 3.8 in (9.6 cm) 18.2 in (46.2 cm) 20.0 lbs (9.0 kg) 12.8 VDC 44" Arjent S2 44 in (111.7 cm) 3.8 in (9.6 cm) 18.2 in (46.2 cm) 24.0 lbs (10.8 kg) 12.8 VDC 53" Arjent S2 53 in (134.6 cm) 3.8 in (9.6 cm) 18.2 in (46.2 cm) 28.0 lbs (12.6 kg) 12.8 VDC 2645 Federal Signal Drie, Uniersity Park, IL 60466-3195 Tel.: (800) 264-3578 Fax: (800) 682-8022 www.fedsig.com #M1006 Arjent, Solaris, Reliable Onboard Circuitry, and SignalMaster are trademarks of Federal Signal Corporation. EPIC is a trademark of Micro Engineering Labs.. 2007 Federal Signal Corporation.