Small Controlled Area Radiography Fundamentals and Technology Advancements. J. R. Lapinskas, PhD and R. L. Kelly

Similar documents
HEALTH AND SAFETY PROGRAM 406 IONIZING/NONIONIZING RADIATION PROTECTION

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

SYNCHROTRON RADIATION ABSORPTION AND VACUUM ISSUES IN THE IR*

LEARNING SPECIAL HAZARD DETECTION TYPES

CCTV, HOW DOES IT WORK?

InstrumentationTools.com

Industrial Radiography (IR) General overview. R. Berden

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

Protecting our Borders while Ensuring Radiation Safety

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

for Photonics Advanced phosphor and glass technologies for high performance alignment, detection, imaging and spectroscopy applications

Underwater Pipe Wall Thickness Measurements by Gamma Backscattering

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

REPUBLIC OF NAMIBIA MINISTRY OF HEALTH AND SOCIAL SERVICES REPORT BY: MS VERA UUSHONA TITLE: INSPECTION OF CONVENTIONAL DIAGNOSTIC X-RAY FACILITIES

Effect of Different Types of Fabricated Anti-scatter Grids in Reducing Backscattered Radiation

HEALTH AND SAFETY MANUAL

EVALUATION OF A NEUTRON-PHOTON SHIELD FOR TRANSURANIC (TRU) WASTE CONTAINERS

Energy and Angular Responses of the Criticality Accident Alarm System Using Current-mode-operated Scintillation Detector

Measuring Couch Motion Accuracy with X-ray Beam Fluence

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

UL268 7 th challenge with single infrared smoke detector

Investigation report. Radiation resistance of fire detectors under the influence of radioactive gamma radiation

Portable Survey Instruments NISP-RP-01

RC4000 Radiation Detection System

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Remote Gamma Imaging of High Dose Environments

Radiometric Level Measurement in DCU Challenges, Solutions and Interpretation Author: Dr. Jan Sielk Process Control

North Dakota State University Laser Safety

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

Seismic Countermeasures for Environmental Radiation Monitoring System

Ronan Model X96S Series Weighing System

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

Fireye FLAME SCANNERS

E-BEAM DRUM TRANSFER: PROCESS TO ELECTRON IRRADIATE A PSA IN THE ABSENCE OF A BACKING.

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Gas Temperature Measurements with High Temporal Resolution

Developing UV LED Curing Processes for Converting Applications

THE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A

Injection with front ends open at the ESRF

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

Radiation Safety issues for the PF-AR in KEK

Meeting NFPA standards for

Identify the following features and specifications for the ESP1

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

高等食品分析 (Advanced Food Analysis) II. INSTRUMENTS FOR OPTICAL SPECTROSCOPY *Instruments for optical spectroscopy: Optical spectroscopic methods are

A new fully digital system for RT inspection of metal tube to tube sheet joints of heat exchangers

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

REGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (Amends In Its Entirety)

Flame Detection Jon Sarfas

Distributed Temperature Sensing

Technologies, Solutions, and Applications. Radiation-based Level

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

DUQUESNE UNIVERSITY. Laser Safety Program

Environmental Radiation Monitoring System

The system can be easily relocated by a standard container truck., and re-commissioned by trained engineers typically within a 72-hour period

WG Entire Truck & Cargo X-Ray Scanning Portal

Advanced Radiation Measurement Solutions

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Gas Detection in Process Industry The Practical Approach

WM2014 Conference, March 2 6, 2014, Phoenix, Arizona, USA

Domestic Nuclear Detection Office (DNDO)

Talentum - Why use our Flame Detectors?

Radiation Monitoring Systems

Lata Mishra Bhabha Atomic Research Centre, INDIA

Experimental Particle Physics PHYS6011 Joel Goldstein, RAL

UVC Detection as a Potential for Alpha Particle Induced Air Fluorescence Localisation

Document Preparation Profile (DPP)

talentum Flame detection across the spectrum Range Brochure

Electrical Safety Compliance: NFPA 70E

New Generation of UV, IR and γ - ray sensors with Carbon Nano-Tubes (CNT)

MSA s Guide to Selecting the Right Flame Detector for Your Application

SICK AG WHITEPAPER 3 TECHNOLOGIES FOR PCB DETECTION

AERIAL RADIATION DETECTORS

Installation and Operation of Model CS X-ray Cabinet. 11 Emery Avenue Randolph, NJ Tel.:

Radiation Alert Frisker INTERNATIONAL

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel

Conspec - Why use our Flame Detectors

Understanding total measurement uncertainty in power meters and detectors

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Pyroelectric Infrared Sensor PIR

LCLS Instruments. Jerry Hastings June 20, 2008 LCLS

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

Establishing a Center of Excellence for. Security Science and Engineering

W.E.T. (Water Extraction Techniques) Lab

WG Container & Cargo X-Ray Scanning Portal

Electron detectors. The most used signals in a scanning electron microscope in standard conditions are the electrons and in particular the SE.

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Department of State Health Services

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

North American Technical Services

Certificate: / 29 April 2014

Advancement In Coating Curing On Railcars

Ultraviolet radiation detector to obtain the rate of particles at different heights

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

NUCLEAR REGULATORY COMMISSION. [Docket No ; NRC ] Exemption Requests for Special Nuclear Material License SNM-362,

Transcription:

Small Controlled Area Radiography Fundamentals and Technology Advancements More info about this article: http://www.ndt.net/?id=22226 Abstract J. R. Lapinskas, PhD and R. L. Kelly QSA Global, Inc., 40 North Ave., Burlington, MA 01803, USA. E-mail: joe.lapinskas@qsa-global.com Radiographic testing (RT) is one of the most efficient and economic NDT methods for volumetric inspection; ensuring safe, reliable construction and ongoing use of critical infrastructure around the world. The penetrating radiation from isotope based gamma ray and accelerator based x-ray generators provide a unique mechanism for creating an image based on the differential absorption of photons in a sample. Unfortunately, the mechanisms of photon radiation interactions with matter that allow for weld quality inspection, measurement of corrosion/erosion in pipe wall, etc. create negative externalities in many environments where RT is often performed. Gamma radiation interferes with critical safety and process control systems. Examples include UV flame detectors, radiation monitoring systems, nuclear level and density gauges, etc. These systems cannot differentiate the gamma rays from a radiography source and the UV photons from a fire or gamma rays from 137 Cs sources used in many nuclear gauges. ALARA The ever-increasing emphasis on reducing occupational exposure and exposure to members of the general public often requires RT to be performed in shooting windows or during off-shifts reducing overall inspection efficiency. SCAR or Small Controlled Area Radiography is the concept of controlling the radiation utilized for RT allowing for radiographic inspection without restrictive shooting windows (24/7 radiography concept), in close proximity to other trades, and without impacting critical sensor systems. This paper describes the fundamental principles for achieving Small Controlled Area Radiography with an emphasis on the use of 75 Se and innovations in SCAR equipment enabling advanced SCAR techniques. Practical SCAR applications covered include: Near nuclear gauges and UV detectors typically <0.5 mr/hr Close proximity to members of the general public <2 mr/hr exclusion zone at 6 feet Minimizing/eliminating flash dose Rope access Keywords: radiography, SCAR, VFD, exclusion zone, 75 Se 1 Problem Definition 1.1 Critical safety systems UV flame detectors Optical flame detection systems are a key component of critical fire safety systems in industrial environments where highly combustible materials are present, instantaneous response to flames is needed, or automated fire protection is required. Typical installations include refineries, fuel transport terminals, offshore platforms, pipeline pumping stations, petrochemical plants, etc. Personnel safety combined with protection of large capitally intensive and often critical infrastructure necessitates uninterrupted operation of critical safety systems including fire/explosion detection and suppression. Ultraviolet (UV) detection systems employ a quartz ion chamber to detect short, UV wavelength photons characteristic of most fires. UV systems respond to most fires, can be used indoors or outdoors, are generally [ID214] 1

solar blind, and have high speed response times (<10 milliseconds). They are the most common general purpose optical flame detectors. Sensitivity to UV wavelengths photons means UV flame detectors are susceptible to false alarms from other sources: lightning, welding, arcs, sparks, and gamma rays/x-rays from radiographic testing (RT). RT can be particularly problematic due to the high photon energy relative to other sources of false alarms. Primary beam radiation incident on a UV detector in any orientation will likely trip the system as can Compton radiation scattered from the test piece or surrounding structures. Even flash dose as a source is projected from the shielded position through a source guide tube into a collimator, lasting at most a few seconds, is capable of tripping these high-speed detectors. Operators have several options to avoid false positives ranging from shutting down and manually monitoring UV flame detectors to forbidding RT altogether. One client reported shutting down and manually monitoring every detector within 0.5 miles (0.8 km) of RT work. The impact on plant operations and plant safety is readily apparent. 1.2 Nucleonic process control equipment (level, density, thickness, mass flow etc.) Nucleonic process control equipment is found in many of the same installations as the optical flame detectors discussed above. Typical process monitoring applications include level gauging/switching, density measurement, thickness gauging, phase profiling, mass flow, etc. Nucleonic gauges generally do not contact process material and are thus ideal for high pressure, high temperature, corrosive, abrasive, caustic applications. Nucleonic gauges operate in either transmission or backscatter mode. Transmission mode consists of a high-energy gamma ray source(s), typically 137 Cs or 60 Co, either external to a vessel in a shield/collimator or internal to a vessel in a diptube Figure 1: Density Gauge (Courtesy of Vega) with a detector(s) on the opposite side or other appropriate external position. Attenuation of the collimated beam varies with process Figure 2: Level gauges material density, composition, or phase. In and phase profilers transmission mode, the detectors measure the uncollided gamma ray flux (i.e., gamma rays that have not been absorbed or elastically scattered). Low energy gamma emitting isotopes such as (Courtesy of Vega) Figure 3: Mass flow gauging for conveyor (Courtesy of Vega) 241 Am along with beta emitting isotopes are used in transmission or backscatter mode for gauging of thin films, paper, foils, etc. As the name implies, backscatter mode measures radiation, often neutrons, that has elastically interacted with process material and scattered back to the detector. Transmission mode nucleonic gauges utilizing high energy gamma emitting isotopes are the most common systems impacted by RT and will be the focus of the following discussion. Several are shown in Error! Reference source not found. Error! Reference source not found.. [ID214] 2

As stated above, the uncollided gamma rays from collimated 137 Cs and 60 Co sources are measured to determine level, density, phases, etc. of process material in a vessel. Table 1 shows the similarity in gamma ray energies from common isotopes used in radiographic testing to those utilized in many nucleonic gauging systems. It is clear that gauging systems will have difficulties differentiating gamma rays from different sources and therefore be susceptible to false readings when RT is performed nearby. Compounding the issue is the significantly higher activity and resulting output of radiography sources versus gauging sources (see activity range and gamma constants in Table 1). Gauge manufacturers attempt to electronically filter direct beam and Compton scatter signals from high energy radiography sources (e.g., high frequency pulses from flash dose). Shielding detectors is an option complicated by the sometimes-large physical size and quantity of detectors (cost and space) as well as cooling requirements for stable operation of scintillation detectors common in gauging. Ultimately, solutions for operators to avoid costly and dangerous false readings include taking process control equipment offline effectively driving blind or shutting down a line completely. The impacts on plant safety and operations are clear. Table 1: Gamma ray energies from typical nucleonic gauging industrial radiographic testing isopopes. [1] Average Gamma Constant per Ci [2] Application Isotope Energy Range Activity Range Energy R/hr @ 1 ft msv/hr @ 1 m 137 Cs 662 kev 662 kev 1 mci 10 Ci 3.4 0.32 Gauging 60 Co 1253 kev 1.17 1.33 MeV 100 mci 10 Ci 14 1.30 75 Se 215 kev 96.7 400.6 kev 10 120 Ci 2.2 0.203 Radiography 192 Ir 370 kev 206 612 kev 10 150 Ci 5.2 0.48 60 Co 1253 kev 1.17 1.33 MeV 20 330 Ci 14 1.30 1.3 Radiation monitoring systems (NPP) Nuclear power plants are particularly weary of introducing additional radiation and radioactive materials into operating environments; especially inside containment areas where HP officers are required to clear out other trades and monitor all RT operations for compliance with approved procedures. Deviations from procedure can trigger NRC reporting requirements. Seemingly innocuous events such as slight difficulty retracting a source, even if returned to a safe and locked position, are considered reportable events under 10CFR34.101 [3]. Another example of a reportable event under 10CFR20.2203 [4] would be flash dose or unanticipated scatter temporarily exceeding limits at posted boundaries. 1.4 Safety / Exclusion zone / Confined work areas / ALARA In addition to the potential impact on safety and process control systems as describes above radiographic testing presents several other obstacles to plant safety and operations. Exclusion zones must be posted and controlled in accordance with regulations. In the USA exclusion zones are posted at 2 mr/hr (20 µsv/hr) for members of the general public. In much of the rest of the world exclusion zones are posted at 0.75 mr/hr (7.5 µsv/hr) for occupationally exposed workers and 0.25 mr/hr (2.5 µsv/hr) for members of the general [ID214] 3

public. Posting and controlling exclusion zones becomes particularly problematic in congested work spaces such as a refinery turnaround where many trades are generally working in close proximity. In this scenario, other trades must either be cleared from the exclusion zone or RT crews must work in shooting windows during breaks, shift changes, or third shifts. Radiography in confined or restricted access spaces increases ALARA and safety concerns. Radiographers must be able to move a safe distance from where the source is being exposed while also maintaining control of the system. Example application areas include offshore platforms, refinery turnarounds, rope access, fabrication shops, laydown yards, etc. Minimizing the negative impact of gamma rays from radiographic testing is the focus of this discussion. 2 Understand to Control SCAR or Small Controlled Area Radiography is the concept of controlling the radiation utilized for RT to minimize the impact on plant operations, increase plant safety, and improve safety for occupationally exposed workers and member of the public. Controlling the radiation used to perform radiographic inspection first requires an understanding of the mechanisms by which radiation interacts with the testing environment. We have found it useful to break down radiation we are looking to control into the primary beam and scatter radiation. Figure 4 visually depicts the primary beam and scatter radiation from a typical DW/SW radiography setup. 2.1 Primary Beam The primary beam is a welldefined, collimated beam of gamma rays emanating directly from the isotope source. The collimated beam expands with increasing distance from the Figure 4: Representation of primary beam and Compton scatter source. Shielding considerations from a typical DW/SW test configuration. are the intensity and cross-sectional dimensions of the primary beam at a specified distance where shielding material will be positioned (typically directly behind the imaging media). Calculations to determine shielding parameters for the primary beam are relatively straight forward. The number of shielding half value layers (HVLs) to reduce the primary beam intensity to a specified dose at a defined distance is a basic inverse square law shielding calculation outlined step-by-step in Figure 5. Note for a contact configuration where the beam width is smaller than the pipe diameter attenuation in the pipe can be considered. Figure 6 shows the determination of beam dimensions at the shielding position. [ID214] 4

Figure 5: Shielding HVLs to reduce the primary beam intensity to a specified dose at a defined distance. Figure 6: Approximation of the beam dimensions at the shielding position. 2.2 Compton Scatter Compton scatter is significantly more complicated to model. For purposes of this discussion we consider a monoenergetic beam of gamma rays (energy =. Three outcomes are possible for the incident gamma rays as they pass through matter: 1) pass through without interacting - the uncollided photon flux 2) absorption through pair production or the photoelectric effect 3) energy dissipating elastic scattering interactions with atomic electrons Compton scatter. Figure 7 show the combined effect of the three mechanisms on the beam spectrum. Absorption reduces the total number of gamma rays available to scatter or pass through without interaction. The uncollided flux was addressed above leaving scattered gamma rays as the second source of radiation to address. Energy loss in Compton scattering events is a function of interaction angle resulting in a continuous spectrum of photons with energy into 4π. In addition, Compton scatter is energy dependent iteraction with the probability of an event occurring increasing with decreasing incident gamma ray energy. The practical takeaway is that Compton scatter complicates shielding setups as radiation is emitted in all directions; however, the scattered gamma rays are significantly lower in energy and intensity than the primary beam generally requiring fewer HVLs of shielding. [ID214] 5

3 Achieving Small Controlled Area Radiography It cannot be emphasized enough that SCAR is more than a radiography device. It is a radiography concept consisting of the radiography device and source, accessories such as positioning fixtures and shielding, and proper techniques to address both the primary beam and scatter radiation described above. The following section outlines these key components to achieving Small Controlled Area Radiography. 3.1 Isotope Figure 7: Energy spectrum of monoenergetic SCAR concepts are not exclusive to a particular gamma rays incident on (dotted red) and exiting isotope; however, the choice of isotope plays a key (solid blue) a shield. [5] role in practical implementation of SCAR techniques. Average energy and energy ranges for typical radiography isotopes are summarized in Table 1. 75 Se is by far the preferred isotope for SCAR applications due to the lower energy of its emissions relative to other available isotopes. When necessitated by material thickness SCAR techniques can also be applied to 192 Ir radiography. To keep shielding practical 192 Ir activities are kept low. As a comparison, consider the required shielding to obtain a 2 mr/hr reading 6 ft from the source in the direction of the primary beam shooting a 6 SCH 40 steel pipe in contact mode with both 75 Se and 192 Ir. Typical maximum activities for SCAR applications are 81 Ci and 15 Ci respectively. From Figure 5 and Figure 6 we calculate the weight of the back shielding to be 15 lb (7 kg) of lead sheet for 81 Ci 75 Se versus 74 lb (33 kg) for 15 Ci 192 Ir. Unless there is an extreme application, it is not practical to apply SCAR techniques for use with 60 Co. 3.2 Device The radiography device is the next key component in achieving SCAR. In its simplest form, traditional projection style radiography involves projecting the source from the fully shielded position in the camera through an unshielded source guide tube to the test position where it remains for the duration of the shot and is then retracted back to the shielded position. The source is effectively completely unshielded from the moment the source leaves the camera to the time it returns (See Figure 8). For pplications such as pipeline weld quality where other trades, sensors, members of the public, etc. are typically not present there is no issue with this technique. SCAR techniques would simply slow inspections down. However, in a refinery or power plant the large exclusions zones introduce myriad complications. For example, the 2 mr/hr boundary for 100 Ci of 192 Ir is approximately 370 ft from the source. An ideal SCAR device minimizes the distance the source travels while never allowing the source to become fully unshielded, eliminating flash dose and simplifying shielding requirements. Below, we demonstrate exclusion zones of several feet with 75 Se in a device specifically designed for SCAR. [ID214] 6

Figure 8: Diagram of traditional projection radiography showing source fully exposed. Figure 9: Cross section of Model 1075 SCARPro showing the fully shielded source path (iso view). 3.3 Fixtures and Shielding The source does not leave the device in Figure 9. It moves from the fully shielded position directly to the collimated exposure position. Therefore, considerations should be made for allowing the radiographer to quickly and securely position and reposition the device in nearly any orientation. Figure 10 shows fixturing for a contact radiograph (e.g., DW/SW). Figure 11 shows fixturing for standoff fixturing for superimposed or elliptical radiographs. Mounting points for the fixturing are integrated into the design of the camera. Figure 10: Contact shot fixture. Figure 11: Fixture for elliptical and superimposed shots. Shielding for radiography comes in many forms. The choice of material and form factor should be matched to the application and shielding requirements. Flat sheets for back shielding the primary beam and draping to control scatter range from simple lead sheets to lead wool blankets to silicone impregnated with a high Z material (e.g., lead, tungsten, or bismuth). Sheets can be bare or packaged in a protective sleeve. Some even have integrated rigging features or magnets to assist with positioning. There are pros/cons to each. Lead is a HAZMAT concern whereas bismuth and tungsten are not. Lead sheets are the most efficient and cost effective however lack flexibility. Lead wool blankets are also relatively inexpensive while offering increased flexibility over lead sheets but continuous flexing can degrade the fibres creating hot spots. Lead, tungsten, or bismuth impregnated silicone is extremely flexible but tends to be the priciest. Figure 12 shows examples of the several types of available shielding sheets. [ID214] 7

Figure 12: (a) Bismuth impregnated FlexShield silicone sheets of various sizes with grommets and handles for mounting and rigging. (b) FlexShield positioned to back shield the primary beam. (c) Pb sheet in canvas sleeve with integrated magnets moulded to shape of pipe. Impregnated silicone can also be moulded into custom shapes. Figure 13 shows a moulded backscatter shield and flexible guide tube shield; both made from bismuth impregnated silicone. The backscatter Figure 13: Flexible scatter shield (left) and guide tube shield (right) shield slides over the made from moulded bismuth impregnated silicone. integral collimator of the SCAR device and conforms to the outer wall of the pipe in a contact configuration. The flexibility of the silicone shield ensures compatibility with various pipe diameters to very effectively attenuate Compton scatter created when the primary beam passes through the near wall of the pipe. Restricted access prohibiting positioning the SCAR device may necessitate the use of traditional projection style radiography. In such a scenario, a guide tube shield reduces flash dose as the source is moved from the shielded position to the exposure position. Proper setup taking into consideration the concepts discussed in this paper will allow for SCAR-like performance for traditional projection radiography. 3.4 Bringing it all Together The above discussions walk through the concepts required to understand and consider in order to successfully achieve Small Controlled Area Radiography. While not overly complex, combining these concepts could easily become overly cumbersome in the fast paced and difficult radiography work environment. To simplify the process of determining a shot setup QSA Global has developed a SCAR Calculator (Figure 14) allowing the user to input readily available device and source date, dose requirements, and sample specifications. The calculator outputs the shot parameters: primary beam shielding requirements, primary beam dimensions, minimum source-to-film distance (SFD) from common geometrical unsharpness [ID214] 8

requirements, overlap to determine total number of shots, and shot time. Predictable and repeatable outcomes can be calculated for both contact and offset configurations. Figure 14 considers a Model 1075 SCARPro loaded with 80 Ci 75 Se shooting DW/SW contact of a 6 SCH 40 pipe. The 2 mr/hr boundary must be set at 6 ft. 2 Rad to the imaging media is required. The SCAR Calculator calculates a total of 11.3 HVLs are required to back shield the primary beam. The pipe itself provides 1.78 HVLs. An additional 9.5 HVLs are required. 3/8 (~1 cm) of lead sheet or four FlexShield sheets provide the required additional shielding. The beam is 6.7 in x 6.7 in (17 cm x 17 cm) at the film plane. Standard 10 in x 10 in (25 cm x 25 cm) in shielding sheets would be recommended for ease of positioning. A minimum of four shots are required to image the entire weld with 0.7 (1.8 cm) overlap. Shot time is 1 minute 21 seconds. A scatter shield (Figure 13) addresses the majority of the scatter off the near wall off the near wall of the pipe. Figure 14: SCAR Calculator. A 6 ft (~2 m) exclusion zone has clear benefits in many applications: Radiography can be performed in close proximity to other trades such as welders, pipe fitter, etc. during turnarounds or outages rather than clearing the area or shooting in windows. Nearby processes utilizing nuclear gauges or necessitating UV flame detectors can be left online and safely monitored. Rope access technicians (RATs) can minimize their exposure while remaining in close proximity to the test location. [ID214] 9

Monitoring and controlling a 6 ft boundary versus boundaries of several hundreds of feet for traditional projection radiography is much easier considering most plants have multiple floors. Common practices are to clear three floors up and three floors down anytime RT is being performed. Hot Work Permits issued and required by most plant safety managers are likely to be easier to obtain based on the vastly reduced zone of influence and repeatable setup geometries. 3.5 Additional SCAR Considerations Figure 15: Beam masking technique for offset SCAR configuration. The SCAR concepts discussed above apply to both contact and offset device configurations. Offset configurations are complicated by the increasing dimensions of the primary beam with increasing SFD. Back-shielding a large beam behind the imaging media can become overly cumbersome with inherently heavy shielding material. It is Figure 16: SCAR setup with shielding positioned over the much more efficient to reduce the end of a pipe segment to attenuate scatter internal to the pipe collimation or mask the beam very near and wrapped around the length of the pipe near the test the source. After all, the beam only needs position to attenuate scatter out of a thin walled pipe. Scatter to be wide enough and tall enough to dose is 4 µsv/hr (0.4 mr/hr) at 2 m (6.6 ft) with 57 Ci 75 Se image the diameter of the pipe/weld and source exposed. heat effect zone in a weld quality radiograph. Figure 15 depicts the beam masking technique that allows for on-site adjustments to beam dimension. Some applications or highly regulated operating environments may necessitate additional shielding considerations. Figure 16 shows a SCAR setup with shielding placed at the end and along the lengths of an open-ended thin walled pipe to attenuate internal scatter and scatter along the length of the pipe. [ID214] 10

4 Conclusion SCAR concepts are well established in some regions of the world where regulations restricting operator and public exposure has driven its adoption (e.g., Europe). In other regions SCAR concepts and techniques have been applied for many years to address the issues described in this paper; with varying degrees of success. Where not driven by regulation, adoption of Small Controlled Area Radiography solutions often requires a paradigm shift both by radiography service providers and the industries they serve. Continual improvement to provide innovative, high quality solutions to customer pain points drives this paradigm shift. Service providers endeavour to address common pain points of their clients associated with radiographic testing. End consumers of RT services, often owners of highly capital intensive facilities, strive to minimize or eliminate anything adversely impacting operational efficiency. SCAR offers RT service providers a customer-back solution for their customers to minimize the impact of radiography on operations, enhance safety, and reduce overall operational liability often associated with industrial radiography. References [1] Korea Atomic Research Institute, Table of Nuclides, 2000. [Online]. [Accessed 25 September 2017]. [2] QSA Global, MAN-027-880 Series Source Projector, vol. November 2014 Release, Burlington, MA: QSA Global, Inc., 2012. [3] U.S. Nuclear Regulatory Commission, NRC Regulations Title 10, Code of Federal Regulations, 29 August 2017. [Online]. [Accessed 20 September 2017]. [4] U.S. Nuclear Regulatory Commission, NRC Regulations Title 10, Code of Federal Regulations, 29 September 2017. [Online]. [Accessed 20 September 2017]. [5] J. R. Lamarsh, Introduction to Nuclear Engineering, 3rd edition ed., Upper Saddle River, New Jersey: Prentice Hall, 2001. [ID214] 11