Outline of Measures for Fire Prevention and Safety under the Laws and Regulations of Fire Fighting

Similar documents
CABINET ORDER FOR ENFORCEMENT OF THE FIRE SERVICE ACT

CHALLENGES IN THE FIELD OF FIRE DEFENSE

Fire Service System in Japan

Inspection and Life Safety Education Division. Public Safety Committee September 9,

Japanese Case Study: How to maintain the fire safety in subway station and tunnel

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

Guideline No 11:2005. European guideline. Recommended Numbers of Fire Protection Trained Staff

Fire Department Fire Prevention Inspection Services. HIGH RISE STRUCTURE Fire Inspection Program

Winnipeg Fire Department Fire Prevention Branch

May 27, Mayor Thomas M. Roach Members of the Common Council City of White Plains 255 Main Street White Plains, New York 10601

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

May 27, Mayor Joanne D. Yepsen Saratoga Springs Commissioners City of Saratoga Springs 474 Broadway Saratoga Springs, New York 12866

What you need to know about. Maintaining essential safety measures in your building

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

ORDINANCE NO. Establishing Fire and Life Safety Requirements for Existing Multi-Family Residential Buildings Classified as Group R, Division Occupancy

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Amagasaki, Hyogo Prefecture: Nagasakiya Department Store

Life Safety and Professional Standards Bureau

Regulations for Fire Protection in Japan

Understanding and Managing Fire Safety in Housing Accommodation

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

NOTTINGHAM CITY HOMES

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Procedure DESCRIPTION/OVERVIEW

Bold items are particular to the City of Euless

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

- CONSTRUCTION FIRE SAFETY STANDARDS

Housing and Fire Safety Tips for Your Home & Property. Micki Jones, SFFD Rosemary Bosque, DBI May 6, 2015, SF Main Library

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Fire Safety Education in Multi- Unit Residential Buildings

Fire Safety Report Fire Protection Management Program and Annual Fire Safety Report on Student Housing

Agency for Health Care Administration

Denver Fire Department Fire Prevention Division

a) Establishment of emergency procedures to be followed at the time of an emergency;

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

Tennessee Code/TITLE 62 PROFESSIONS, BUSINESSES AND TRADES/CHAPTER 32 FIRE PROTECTION/PART 1 FIRE PROTECTION SPRINKLER SYSTEMS

Fire Safety Plan Information. For Construction and Demolition Sites

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

FIRE PROTECTION INTRODUCTION

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Agency for Health Care Administration

Date and Time of Incident. March 10, 1975

Fire Safety Report Fire Protection Management Program and Annual Fire Safety Report on Student Housing

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

SIOUX FALLS FIRE RESCUE STRATEGIC PLAN

Martin Paren HM Inspector of Health & Safety

City of Philadelphia

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Plan Change 56: Fire Fighting Water Supplies Code of Practice

HIGH-RISE RETROFIT ORDINANCES - NO and NO

FIRE SAFETY MAINTENANCE INFORMATION for Agricultural Livestock Structures

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Fire Safety Safety Program

The Social Accountability International (SAI) Fire Safety Checklist

LexisNexis (TM) New Jersey Annotated Statutes

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

CAMPUS COMMUNITY FIRE AND LIFE SAFETY POLICY

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

MINISTERIAL ORDER NO.(6) OF 2013 WITH RESPECT TO PROTECTION OF WORKERS FROM THE HAZARDS OF FIRE IN ESTABLISHMENTS AND WORK SITES

Agency for Health Care Administration

Latest update: Ordinance of the Ministry of Internal Affairs and Communications No. 25 of March 27, 2013

Date of Authorization May 26, 2005 BMEC Authorization BMEC Application # A

2010 FIRE CODE OF NEW YORK STATE

Renovation Program. Renovation Program GENERAL

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

Johnson County, Kansas. Home Daycare Handbook 2013 Edition

Safety Inspector III Class Description

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

ORDINANCE FOR TECHNICAL SPECIFICATIONS PERTAINING TO AEROSOL TYPE EXTINGUISHER APPLIANCES

District of Sicamous. Fire Department Bylaw No. 126, Effective Date February 26, 1996

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

OFM-TG FIRE SAFETY PLANNING FOR RECYCLING FACILITIES AND WASTE PROCESSING OPERATIONS

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

CHAPTER 7 ALTERATIONS LEVEL

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

Fire Risk Assessment Safety Checklist

Annual Fire Safety Report

FIRE PREVENTION AND PROTECTION*

Ministerial Ordinance for Enforcement of the Fire Service Act

Landscape Act. (Act No. 110 of June 18, 2004)

Agency for Health Care Administration

Family Foster Home Fire Safety Evaluation Checklist Instructions

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Overview of the Refrigeration Safety Ordinance

FIRE SAFETY LOG BOOK

Short Term Accommodations Fire Code Requirements

Fire Prevention Bureau INFORMATION PACKAGE

Fire Risk Assessment

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

SPRINKLER ORDINANCE Town of Yarmouth, Maine Recodified: 1/15/98 Amended: 4/19/01 Amended: 6/18/15

In recent years the Hungarian Fire Protection Regulation has changed much more frequently and in greater extent than in previous years.

[NOTE: Proposed additions to existing code language are highlighted in yellow.]

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

Transcription:

Outline of Measures for Fire Prevention and Safety under the Laws and Regulations of Fire Fighting Materials created by the Fire and Disaster Management Agency were translated by the International Fire Service Information Center 1

Fire in Japan Total number of buildings for business purposes and apartment houses: about 4 million Of these, buildings that are required to install a sprinkler system : about 67,000 Annual number of fires: about 48,000 cases Of these, building fires: about 25,000 cases Of these, residential fires: about 14,000 cases 1,625 fatalities 1,254 fatalities 1,100 fatalities Leading cause of death from building fires (1) CO poisoning/suffocation (38.2%) (2) Burns (37.6%) Leading causes for building fires (1) Cooking utensils (14.6%) (2) Cigarettes (10.0%) (3) Arson (9.0%) (4) Heating devices (5.7%) (5) Suspicion of arson (5.3%) 2

Trend in the Number of Fires and Fatalities Case People Number of fires Number of deaths 03 04 05 06 07 08 09 10 11 12 13 (Year) 3

Number of Building Fires by Purpose of the Building Where the Fire Originated Shops for the sale of goods 374 cases (1.5%) Others 4,290 cases (17.1%) Year 2013 Warehouses 558 cases (2.2%) Restaurants 588 cases (2.3%) Business offices 814 cases (3.2%) Factories and workshops 1,750 cases (7.0%) Number of building fires 25,053 cases Conventional homes 8,892 cases (35.5%) Residences 13,621 cases (54.4%) Multipurpose buildings 3,058 cases (12.2%) Dwelling houses combined with other uses 626 cases (2.5%) Apartment houses 4,103 cases (16.4%) 4

Division of National Government Roles regarding Measures for Fire Prevention and Building Safety Building structure (Fire prevention section, making interior decoration non-combustible, stairs, and others) Ministry of Land, Infrastructure, Transport and Tourism (Building Standards Act) Fire fighting equipment (including fire hydrants and sprinklers) Fire control (including fire management, maintenance of equipment, and training) Fire and Disaster Management Agency of the Ministry of Internal Affairs and Communications (Fire Services Act) 5

Measures for Fire Prevention and Safety under the Laws and Regulations of Fire Fighting (Overview) Prevention of fires Appointment of a fire prevention management chief Implementation of fire fighting and evacuation drills Fire management Compilation of fire prevention plans Implementation of inspection of facilities to be protected from fire Utilization of fire prevention goods Sensing/detecting/notifying Fire fighting in the initial stage Automatic fire detection system (Automatically notify the outbreak of a fire to inside the building) Fire alarms for a short circuit (Notify a short circuit via alarms) Fire extinguisher Indoor fire hydrants Sprinkler system Other automatic fire fighting equipment Fire brigade operations Water for fire prevention Emergency outlet equipment Wireless communication auxiliary devices Evacuation guidance Evacuation tools Exit route lighting /evacuation signage Technology criteria and procedures are established by government ordinances and municipal ordinances based on the Fire Services Act. Also, necessary measures for fire prevention and safety are required in accordance with the purpose of the building, scale, and number of people. In addition, the fire fighting laws and regulations are applied to existing buildings as well (excluding some fire fighting equipment). 6

Examples of Fire Fighting Equipment Fire alarms for a short circuit Indoor fire hydrants Automatic fire detection system Fire extinguisher Exit route light Escape ladder Sprinkler heads 7

Reference Confirmation System before Starting to Use Facilities to Be Protected from Fire Clients or their agents/people who are involved with the facilities to be protected from fire or management officials Building officer or designated confirmation and inspection body Facilities to be protected from fire: schools, hospitals, factories, department stores, office buildings, and condominiums. Agreement Confirmation Fire prevention management chief Fire protection equipment engineers Commencement of construction works Interim inspection Inspection on completion Notification of commencement of construction works Notification of installation of fire fighting equipment or others Notification of starting to use facilities to be protected from fire Fire chief or fire station chief Inspection Issuance of certificate of inspection Notification of the appointed fire prevention management chief Submission of fire prevention plans Issuance of certificate of inspection 8

Reference (People who are involved in) facilities to be protected from fire Confirmation System before Starting to Use Facilities to Be Protected from Fire Commission of design Certificate of confirmation Registered architect Commission of construction works (Commission of interim inspection) Application for confirmation Report of examination results Certificate of confirmation Building officer or designated confirmation and inspection body Fire protection equipment engineers (Interim inspection) Fire protection equipment engineers Notification of installation of fire fighting equipment or others Commission of inspection on completion Inspection on completion Issuance of certificate of inspection Request for fire fighting agreement Agreement Document that notifies the commencement of construction works (Commission of interim inspection) Fire chief or fire station chief Notification of starting to use facilities to be protected from fire 1 Notification of the appointed fire prevention management chief Fire prevention management chiefs Submission of fire prevention plans * Facilities to be protected from fire include schools, hospital, factories, department stores, office buildings, and condominiums. 9

Reference Confirmation System after Starting to Use Facilities to Be Protected from Fire People who are involved in facilities to be protected from fire or management officials Implementation of fire prevention management operations Fire prevention management chiefs Fire protection equipment engineers Qualified inspector of fire protection equipment On-site inspection Drawing up and revising fire prevention plans Fire fighting and evacuation training Inspection of fire fighting equipment Supervision of fire use Evacuation equipment management Capacity control Inspection of fire fighting equipment and others Inspection results report of fire fighting equipment and others Regular inspections of facilities to be protected from fire Fire chief or fire station chief Inspection rules / regulation for handling violations Qualified inspector of facilities to be protected from fire Inspection results report of facilities to be protected from fire Application for special cases Application form for special cases is in the inspection results report of facilities to be protected from fire 10

<Examples of Fire Fighting Equipment Installation Standards (1)> Sprinkler System Installation Standards Sprinkler head standards (extract) To operate within the prescribed time at an air current temp. of 135 C, and an air current speed of 1.8 m/s To uniformly gain a water sprinkling distribution of 0.2 L/min/cm 2 Other standards include strength, corrosion, oscillation, and water hammer resistance Certification of sprinkler heads Sprinkler system installation standards (extract) Sprinkler heads in a fireproof building must be installed within a horizontal distance of 2.3 m or less in each part of the ceiling Sprinkler systems must be capable of a water discharge pressure of 0.1MPa or more, and a water discharge amount of 80 L or more at the top of each head when multiple heads operate simultaneously Other standards include installation height, emergency power sources, pumps, pipe laying, and water source standards Model standard conformance test Certified by the Minister Sampling test of individual products Applying a seal of approval to an accepted product Japan Fire Equipment Inspection Institute Shipping Obligation to use conforming products Preliminary examination by fire headquarters Execution of installation Inspection by fire headquarters after installation To inspect the sprinkler system every year for proper functionality, and to report the result of the inspection to fire headquarters To have an on-site inspection by fire headquarters and to receive instructions on any defects and correction orders Planning and construction In use 11

<Examples of Fire Fighting Equipment Installation Standards (2)> Automatic Fire Detection System Installation Standards Detector standards (extract) To send a signal within the necessary operation time when placed in a vertical air current at a speed of 1 m/s at 125% of nominal operating temperature (example of a fixed temperature detector) Not to operate at a temperature 10 C lower than the nominal operating temperature Other standards include strength, corrosion, oscillation, and heat-resistance Certification (same as sprinkler heads) Standards of a receiver (abstract) To have functions that automatically display the cautionary zone of a fire and sounds an alarm when receiving a fire signal To display the cautionary zone within five seconds from starting receiving a fire signal Other standards include strength, corrosion, oscillation, and heat-resistance Certification (same as sprinkler heads) Obligation to use conforming products Automatic fire detection system installation standards (extract) To install a detector in each guarded area (every 500 m 2 ) To install the detector at least 0.6 m from walls or crossbeams to prevent malfunction When sounding a limited alarm on the floor that a fire breaks out or on the floor above, to sound an alarm to the whole building if the fire signal does not stop after a certain period of time Other standards include installation height, emergency power sources, pumps, pipe laying, standard of water source Preliminary examination by fire headquarters Execution of installation Inspection by fire headquarters after installation To inspect the sprinkler system every year for proper functionality, and to report the result of the inspection to fire headquarters To have an on-site inspection by fire headquarters and to receive instructions on any defects and correction orders Planning and construction In use 12

Installation Rate of Sprinkler Systems and Automatic Fire Detection Systems (As of March 31st, 2014) Building Intensive care home for the elderly, and others Standard (Note 1) In principle, all Retailer 3,000 m 2 or above Sprinkler system Required number Installed number Installation rate Automatic fire detection system Standard (Note 2) Required number Installed number Installation rate 31,534 31,415 99.6% All 39,956 39,822 99.7% 7,317 7,265 99.3% 300 m 2 or above 87,704 85,983 98.0% Hotel 6,000 m 2 or above Underground shopping mall 1,000 m 2 or above 1,989 1,980 99.5% All 45,823 45,396 99.1% 58 58 100% 300 m 2 or above 62 62 100% Total of all facilities 67,085 66,792 99.6% 554,149 541,392 97.7% (Note 1) Article 12 of the enforcement ordinance of the Fire Services Act. Installation standards are as of April 1st, 2015. (Note 2) Article 21 of the enforcement ordinance of the Fire Services Act. Installation standards are as of April 1st, 2015. 13

On-site Inspections, Handling Violations Number of facilities to be protected from fire: about 4 million (as of March 31st, 2014) Number of on-site inspections by fire-fighting personnel 890,000 cases per year (FY2014) Number of correction orders 117 cases per year (FY2014) 14

Mandatory Installation of Residential Fire Alarms Trend in the number of fatalities due to residential fires The number of fatalities due to residential fires (excluding suicides) exceeded 1,000 in 2003, and reached 1,220 in 2005. Approximately 60% of those fatalities involved elderly persons aged 65 years or older, which will tend to increase reflecting the shift to an aging society. (Approximately 60% of fatalities were due to people who failed to escape from a fire.) * Non residential buildings were already required to install fire alarms, but detached houses were not yet required to do so. There are concerns over further increases with the shift to an aging society. Revision of the Fire Services Act in 2004 required the installation of residential fire alarms in bedrooms and other areas of all houses. Installation rate:approximately 80% (As of June, 2014) Locations to be installed Living room Residential fire alarms Bedroom Corrido r Residential fire alarms Bedroom Living room Residential fire alarms Stairs With the spread of residential fire alarms, the number of fatalities due to residential fires has been decreasing. Homes with residential fire alarms also received added benefits in terms of a decrease in fatalities, fire-damaged area, and amount of damage, compared with those without a fire alarm. 15