Fire Risk Assessment and Computer Simulation of Fire Scenario in Underground Mines

Similar documents
How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Environmental Management System Environmental Contingency Program

Y. ORMIERES. Fire risk analysis method for nuclear installations

Considerations in the Design of Smoke Management Systems for Atriums

Fire Investigation in Italian Waste Treatment Plant: lessons learned and future development

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

How design fires can be used in fire hazard analysis

Analysis of Causes of Defects Gloves and Bar Soap Using Failure Mode and Effect Analysis (FMEA) in XYZ Company

Failure Mode Effect Analysis in a Frying Pan Manufacturing Industry

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Probabilistic-deterministic modelling of fire spread

Numerical Standards Listing

FIRE SAFETY FOR OFFICE WORKERS

Simulation of Full-scale Smoke Control in Atrium

Tampa, FL Fire Cause Classification Task Group Tue, 14 April 2011

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

2010 Fire Log Fire Log. Annual Fire Safety Report

METHODOLOGY OF VISUAL IMPACT ASSESSMENT ON SURFACE MINES AND MEASURES OF MANAGING WITH THE VISUAL RESOURCE FOR THE DESIGN OF SURFACE MINES

Fire Dynamics Simulation and Evacuation for a Large Shopping Center (Mall), Part II, Evacuation Scenarios

International Journal of Advance Engineering and Research Development

Safety by Design. Phone: Fax: Box 2398, RR2, Collingwood, ON L9Y 3Z1

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Effects of Smoke on Evacuation Martin Lopušniak 1, a

Modeling a real backdraft incident fire

Case Study of Underground Car Park. Team Japan

Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

Fire Risks of Loviisa NPP During Shutdown States

To obtain a greater understanding of the factors which contribute towards fire injuries and fatalities

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Contractor Worksheet Underground Fires Major Hazard Standard

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

GAS DETECTOR LOCATION. Ø.Strøm and J.R. Bakke, GexCon AS, Norway

The Development of Fire Risk Assessment Method for Heritage Building

Sprinklers Modeling for Tunnel Road Fire Fighting

WHAT IS FIRE DISASTER? Fire Disaster is an occurrence or an incident of such magnitude which creates a situation in which the normal life is suddenly

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

The Swedish National Board of Housing, Building and Planning s general recommendations on the analytical design of a building s fire protection, BBRAD

Analyzing of Reduction Process of Urban Open Spaces in Process of Cities Development with Emphasis on Crisis Management in Tehran Metropolis

Fixed fire protection solutions

Underground fires in metro systems failures, accidents and terrorism

Identifying and Preventing Dust Fire and Explosion Hazards

ADIPEC 2013 Technical Conference Manuscript

Fire and Gas Detection and Mitigation Systems

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

ISO/TR TECHNICAL REPORT. Fire-safety engineering Technical information on methods for evaluating behaviour and movement of people

What is an Emergency?

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

1.1. SCOPE OF THE WORK:

Adrian Milford Sereca - a Jensen Hughes Company, Project Engineer Vancouver, BC, Canada

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Research Needs for the Fire Safety Engineering Profession

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Enclosure 4- RISK ASSESSMENT

ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE. Paul Baybutt Primatech Inc. and

Risk Management of Fire using Video Based Detection

Numerical Standards Listing

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

Fire is No Accident Fire is No Accident It can be prevented.

COMPARISON OF NFPA AND ISO APPROACHES FOR EVALUATING SEPARATION DISTANCES

Aspirating Gas Detection CFD Modelling Predicts Application Performance

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

Unit 6: Fire Investigation

Applying Layer of Protection Analysis (LOPA) to Accelerator Safety Systems Design. Feng Tao

Numerical Standards Listing

FIRE PROTECTION PROGRAM

Research on Decision Tree Application in Data of Fire Alarm Receipt and Disposal

Journal of Faculty of Engineering & Technology

Tunnel Fire Dynamics and Evacuation Simulations

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

4.13 Security and System Safety

Reconciliation of ventilation and production expansion in a potash mine

Hazardous Gas Detection using ARDUINO

Forecasting the Number of Fire Accidents in the Philippines through Multiple Linear Regression

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

Opening up the Gas Market (OGM) Project Oban - Laboratory and Field Testing Results

Research on fire protection methods and a case study "Futurum"

IFE Level 3 Diploma in Fire Science and Fire Safety

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

Electrical failure during NPP cable fires

INCREASING BOILER EFFICIENCY BY USING DIFFERENT MEASUREMENTS AND TYPES OF FIRETUBE PLATES AND DIFFERENT NOZZLES

Update on SFPE Design Fire Scenarios Standard. Charles Fleischmann University of Canterbury

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

Emergency Response Plan

research highlight Canadian Housing Fire Statistics Findings

NATIONAL COMPETENCY STANDARD

International Journal of Advancements in Research & Technology, Volume 2, Issue 8, August ISSN

SIL DETERMINATION AND PROBLEMS WITH THE APPLICATION OF LOPA

Become familiar with the subject areas in the table of contents for OSHA standards through and

Management Practices: Fire Protection Impairments November 2015

ISHRAE. Guideline document to ISO Version 1 Feb Indian Society of Heating, Refrigerating and Air Conditioning Engineers

An experimental study of the impact of tunnel suppression on tunnel ventilation

5 Key Stages to Risk Assessment

Transcription:

Studies in Engineering and Technology Vol. 2, No. 1; August 2015 ISSN 2330-2038 E-ISSN 2330-2046 Published by Redfame Publishing URL: http://set.redfame.com Fire Risk Assessment and Computer Simulation of Fire Scenario in Underground Mines Vancho Adjiski 1, Zoran Despodov 1, Dejan Mirakovski 1, Stojance Mijalkovski 1 1 Faculty of Natural and Technical Sciences, Mining engineering, Goce Delchev University, P.O. Box 201, 2000-Shtip, R.Macedonia Correspondence: Vancho Adjiski, Faculty of Natural and Technical Sciences, Mining engineering, Goce Delchev University, P.O. Box 201, 2000-Shtip, R.Macedonia Received: May 19, 2015 Accepted: June 8, 2015 Online Published: June 24, 2015 doi:10.11114/set.v2i1.825 URL: http://dx.doi.org/10.11114/set.v2i1.825 Abstract Unsafe working conditions in underground mines have led to a number of accidents, loss of life, damage to property, interruption of production, etc. Safety is essential in mining industry, which in recent years mainly focuses on injury prevention in the workplace through a variety of procedures and employee training. The primary goal of this paper is to present a methodology with systematic analysis to determine the most risky places for fire occurrence in underground mines and using a computer simulation to determine the movement of smoke and fire gases trough underground mining facilities from which depends the safe evacuation of all employees. Keywords: underground mines, fire risk assessment, modeling fire scenarios, computer simulation 1. Introduction Fires that occurred in underground mines, generate many dangers and problems for the people that are affected by this emergency situation. Because of this it is required more detailed research in this area and proposing appropriate measures to reduce the risk caused by fires. In underground mines, fire can occur anywhere where flammable material is located, but it is practically impossible to predict all possible locations for fire scenarios (Conti et al., 2005). Using a systematic analysis, this list of fire locations can be limited to those places that have the highest risk of fire occurrence (Iannacchione et al., 2008). Results from the fire assessment can be used to identify and locate the most destructive fire scenarios in underground mines, and with help of computer simulation to build effective system for evacuation. Traditionally the most analysis for evacuation of fire scenarions accidents, focus more on commercial buildings and the evacuation of large populations in public areas. Evacuation systems of this type are many and also well documented. However systems for evacuation in case of fire in underground mines are little and relatively limited. There are attempts from previous researches of making an effective system for evacuation in case of fire in underground mines, but they all have certain limitations in terms of accuracy, because they are based on simplified 2D maps that do not include the actual sizes of the mine together with many ramps, shafts, tunels, etc. Therefore in this research paper will attempt to develop methodology that include fire risk assessment and computer simulation of fire scenario which will show the safe routes for evacuation and rescue in case of fire in underground mines. This presented model will have increased accuracy compared to other models presented so far, because of the prepared 3D model of the underground mine which involved actual dimensions of mine along with its associated elements from which the fire dynamics and system for evacuation depends. 2. Evaluation of Risk Assessment for Occurrence of Possible Fire Scenarios in Underground Mine "Sasa" R.Macedonia The first step in this analysis is the identification of potential fire locations, fire types and the associated consequences. In order to do this a fire risk assessment is necessary. Underground mine fire sources include, but not limited to (Mitchell, 1996): Mobile diesel equipment; Conveyor belts; 54

Compressor stations; Electrical substations; Oil/Lubricant, diesel storage warehouses; Grinding/welding areas in shops and in mine/plant; Shop maintenance areas; Powder/explosive magazines; Tires and wood in warehouses. Each of these areas need to be examined by experts and engineering personnel and the seriousness of each fire scenario are determined by the potential frequency of the hazard, number of people affected, potential spread of contaminants, cost of damage etc. The more formal, team-based risk assessment for identification of potential fire location scenarios, include the following: Reviewing an entire work area; Reviewing manuals for working processes; Observing introduction to new working process; Implementing of new equipment; Observing sources of danger associated to the process tasks/activities; Reviewing statistical data of past injuries. Statistically, the biggest cause for initiating fires in underground mines is the diesel mechanization and warehouses for storage of diesel fuel and other flammable materials (Mallett & Brnich, 1999). For identification of possible fire scenarios in underground mine for lead and zinc "Sasa" R.Macedonia, we will be reviewing and observing sources of danger in all work areas and we will use the manuals for working processes and the diesel mechanization to identify all potential fire scenarios. From the manuals of working processes and the diesel mechanization of "Sasa" mine we identified possible fire scenarios from working diesel mechanization: Minetruck MT 2010, Scooptram ST3.5 and from working activities in the warehouse for diesel fuel. The locations of possible fire scenarios, caused by the above mentioned diesel mechanization will mostly depend on the frequency of their work activities through all underground mining facilities (Zalosh, 2003). To eliminate less risky places for occurrence of fire scenarios from this diesel mechanization we will discard those places in the underground mine where this mechanization has a minimum operating activities (Jain, 2007). The first step in the analysis of occurrence for possible fire scenario is the identification of potential fire sites, analysis of combustible materials and the associated consequences of the fire (Bahr, 1997). In order to make this calculation, you need risk analysis that would single out the most risky locations of occurrence of fire scenarios (Thyer, 2002). The method that will be used in this risk assessment is the modified matrix method that can be used to assess the risks in the workplace, the ranking of the different risks, the acceptability of risk and priority ranking (Donoghue, 2000). The advantage of this method is that can be easily understood by all employees in the mine. Fire risk assessment is possible if we know the nature of dangers, harms and the factors that define the intensity. The data obtained by fire risk assessment is combined with data from other sources (such as data obtained by monitoring employees health, permissible levels of exposure and available statistical data, exposure limit values, etc). In this matrix method for fire risk assessment, the risk is seen as the emergence of dangers and hazards. This fire risk assessment is the product of two dimensions (Donoghue, 2000): The severity of consequences for an employee in case of fire occurrence; The probability and frequency of fire occurrence. The term consequence in the risk assessment can be considered as the "worst case scenario" or outcome that can be reasonably expected if fire incident occur. Generally, consequences can occur in two areas: personal injury/death and property/process damage. The probability of an incident occurring is largely dependent on the exposure frequency. The following aspects should be considered defining the probability: The number of times that fire situations occur; The number of people that are exposed; What has happened in the past in similar situations. Once the consequence and probability of each potential fire scenario has been determined, the corresponding numerical value for consequence and probability from the respective tables can be used to determine the "level of risk". The values for consequence and probability are divided in 4 categories of risk, namely: high, medium, low and insignificant. The numerical value is assigned to each category of risk in that manner that the highest risk has the biggest number. The riskiest locations in "Sasa" mine for fire scenarios caused by loader Scooptram ST 3.5, are those locations where 55

this mechanization is mostly used, and these locations are the excavation bloks. Next step is to determine the size of the associated risks and to determine whether these risks are tolerable (Raman, 2003). Table 1. Consequence Evaluation Consequence (C) CRITERIA OF INJURIES AND DAMAGE CAUSED BY FIRE - Death of one or more people - Permanent disability - Irreparable damage to materials - Loss in production - Factors affecting the Company s image - Injuries causing temporary disability of one or more persons - Remediable or partial damage of the working machinery - Production losses that require special plans to rebuild VALUE HIGH (8) MEDIUM (4) - Non-disabling injuries - Damage to materials that do not affect the production process - Minimum production losses LOW (2) - Almost no losses INSIGNIFICANT (1) Table 2. Probability Evaluation CRITERIA TO ESTIMATE PROBABILITY Probability that fire incident may occur over eight (8) times in a year VALUE HIGH (8) Probability (P) Probability that fire incident may occur from two (2) to eight (8) times a year Probability that fire incident may occur once (1) a year MEDIUM (4) LOW (2) Probability that a fire scenario does not become an incident during the year Table 3. Risk Magnitude Calculation Consequence (C) 1 2 4 8 1 1 2 4 8 Probability 2 2 4 8 16 (P) 4 4 8 16 32 8 8 16 32 64 INSIGNIFICANT (1) Risk Magnitude (MR) of accident from fire scenario is obtained by multiplying Probability (P) times Consequence (C) (Pattnaik, 2009). Table 4. Analysis of possible locations for the occurrence of fire scenario from loader Scooptram ST3.5 Preliminary Hazards Analysis TASKS/ PROCESSES Working activities LOCATION DANGER INCIDENT OCCURANCE Fire from Probability that fire Excavation flammable incident may occur block 1,2,3 materials of from two (2) to loader eight (8) times a Scooptram ST year 3.5 RISK EVALUATION Maximum Minimum C P MR C P MR 8 4 32 2 4 8 The riskiest locations in "Sasa" mine for occurrence of fire scenarios caused by diesel machinery Minetruck MT 2010, are those locations where this mechanization is mostly used and these are the mining transport ramps. 56

Table 5. Analysis of possible locations for the occurrence of fire scenario from diesel machinery Minetruck MT 2010 Preliminary Hazards Analysis TASKS/ PROCESSES LOCATION DANGER INCIDENT OCCURANCE RISK EVALUATION Maximum Minimum C P MR C P MR Fire from Working activities Mining flammable materials of Probability that fire incident may occur transport ramps diesel machinery Minetruck MT 2010 once (1) a year 8 2 16 2 2 4 From the manuals for working processes in "Sasa" mine is identified possible fire scenario from working activities in the warehouse for diesel fuel Table 6. Analysis of the location of fire scenario occurrence in the warehouse for diesel fuel Preliminary Hazards Analysis TASKS/ PROCESSES LOCATION DANGER INCIDENT OCCURANCE RISK EVALUATION Maximum Minimum C P MR C P MR Working activities Warehouse for diesel fuel Fire from diesel fuel Probability that fire incident may occur over eight (8) times in a year 8 8 64 2 8 16 Figure 1. Possible fire scenarios in underground mine for lead and zinc ore - "Sasa" R.Macedonia From the results obtained from fire risk assessment done in "Sasa" mine we identified the fire scenario in the warehouse for diesel fuel to be most destructive. For this fire scenario we will make fire model and with help of computer simulation we will determine the movement of smoke and fire gases and based on these results we will identify the safe routes for evacuation and rescue (Kumar, 2014). 2.1 Modeling of Fire Scenario in the Warehouse for Diesel Fuel in Underground Mine "Sasa" - R.Macedonia In this analysis for modeling of fire scenario in the warehouse for diesel fuel in underground mine "Sasa" - R.Macedonia, we will not analyze possible sources of ignition of the fire but will assume that the fire has already happened and thus we analyze only the products of combustion from the fire scenario and their movement through underground mining facilities. Fire model describes the fire characteristics, such as for example: heat release rate, heat flow, burning rate of material, generating toxic gases, smoke, etc (Hansen, 2010). 57

Studies in Engineering and Technology Vol. 2, No. 1; 2015 Table 7. Properties of diesel fuel Diesel fuel Diesel fuel in the tank 1000 l Density of diesel fuel 918 kg/m 3 Simplified chemical hydrocarbon formula of diesel fuel C 12 H 23 Heat of combustion 46 108 kј/kg Burning rate of Diesel fuel (experimental data) (Totten et al., 0.045 Kg/m 2 *s 2003) From the software for modelling fires Pyrosim (PyroSim User Manual, 2012), and the chemical and physical characteristicss of the diesel fuel (Table.7), we get the following experimental software results for burning 1000 litres of diesel fuel: Figure 2. Heat release rate Figure 3. Volume flow of smoke and fire gases generated by the fire Figure 4. Heat flow Figure 5. Generationn of carbon monoxide from fire Scenario 1: Figure 6. Oxygen in fire place Figure 7. Generating soot from fire Figure 8. Process of modelling fire scenario 1 58

To calculate the movement of smoke and fire gases in the previously specified location in the underground mine SASA - R.Macedonia, we will use the software MINEFIRE PRO + (MineFire Pro+ User Manual, 2013). In the software MINEFIRE PRO+ we are entering the previously calculated fire characteristics from the software Pyrosim, for the fire pool caused by leakage and ignition of 1000 litres of diesel fuel from the warehouse for diesel fuel. Table 8. Input fire parameters in software MINEFIRE PRO +, for fire scenario 1 Volume flow of Concentration of Heat Flow Concentration of Volume flow Time for smoke and fire carbon monoxide in from the fire, oxygen in the fire of air in the complete gases generated the volume flow of (kw) location O 2, (%) branch Q, development of by the fire, smoke and fire (m 3 /s) the fire (min) (m 3 /s) gases CO, (%) 14.42 0.0077 1053.3 20 13 1 In software Pyrosim for fire scenario 1, for complete combustion of 1000 litres of diesel fuel, we obtained the fire time length of 366.6 minutes. From the analysis and calculations of fire scenario 1, done in software MINEFIRE PRO +, we get the following results for movement and spread of smoke and fire gases: Figure 9. Calculations for movement of smoke and fire gases made in software MINEFIRE PRO + for fire scenario 1 The next step after the analysis and calculations for the movement of smoke and fire gases generated by the fire scenario 1, is locating the position of all workers in the underground mine and giving them orders and guidelines based on the previously calculated safe routes for evacuation (Figure 9). 3. Conclusion: Risks of fire occurrence in underground mines are known for a long time. Accidents caused by fire not only can cause damage or at worst deadly consequences, but also cause big expenses because of losses in production, repairs and loss of good will to work. The quick action and preconditioning for dealing this kind of emergency can help save lives and protect the financial investments in the mine. The purpose of this fire risk assessment in underground mines is the identification of possible fire scenarios and their harmful consequences for the life of employees and also finding preventive measures to reduce this risks. This paper presents a methodology for analyzing the risk of fire occurrence, and a system for modeling and simulation of fire scenario which can produce effective system for evacuation in case of fire in underground mines. References Bahr, J. (1997). System Safety Engineering And Risk Assessment: A Practical Approach, Taylor And Francis, NY Conti, R., Chasko, L., & Wiehagen, W. (2005). Fire Response Preparedness For Underground Mines. National Institute For Occupational Safety And Health-NIOSH, Pittsburgh Research Laboratory, Pittsburgh, PA, Hansen, R. (2010). Design Fires In Underground Mines (Doctoral Dissertation). Mälardalen University, Sweden Iannacchione, A., Varley, F., & Brady, T. (2008). The Application Of Major Hazard Risk Assessment (MHRA) To Eliminate Multiple Fatality Occurrences In The US Minerals Industry. U.S Department Of Health And Human Services. Centers For Disease Control And Prevention. National Institute For Occupational Safety And Health Spokane Research Laboratory Spokane, WA, 59

Jain, S. (2007). Environmental And Safety Risk Assessment In Mines (Master s Thesis). Department Of Mining Engineering. National Institute Of Technology Rourkela, Orissa, Kumar, P. (2014). Risk Analysis By Using Failure Mode And Effects Analysis For Safe Mining. International Journal Of Science And Research, (IJSR), 3(11), 2512-2515 Mallett, L., & Brnich, M. (1999). Focus On Prevention: Conducting A Fire Risk Assessment. U.S. Department Of Health And Human Services. Centers For Disease Control And Prevention. National Institute For Occupational Safety And Health, Pittsburgh Research Laboratory, Pittsburgh, PA, Minefire Pro+ User Manual, A Simulator For Underground Fires. (2013). (USER'S MANUAL & TUTORIAL), Mine Ventilation Services, Inc., Clovis, CA, USA Pattnaik, S. (2009). Assessment Of Safety And Environmental Risk In Mines (Master s Thesis). Department Of Mining Engineering. National Institute Of Technology Rourkela, Orissa Pyrosim User Manual-Pyrosim Documentation. (2012). (User Manual Of Computer Code), Thunderhead Engineering Consultants, Inc.Manhattan, KS, USA Raman, R. (2003). Underground Mine Safety- Are We Doing Enough?, Kellogg Brown & Root Pty Ltd, Sydney Thyer. A. (2002). Development Of A Fire And Explosion Risk Assessment Methodology For Underground Mines. Health And Safety Laboratory, United Kingdom, Totten, G., Westbrook, S., & Shah, R. (2003). Fuels And Lubricants Handbook: Technology, Properties, Performance, And Testing, Vol.1, ASTM International, West Conshohocken, PA Zalosh, R. (2003). Industrial Fire Protection Engineering. John Wiley & Sons Ltd, Worcester, WA. http://dx.doi.org/10.1002/9781118903117 This work is licensed under a Creative Commons Attribution 3.0 License. 60