LAB-LINE EXPLOSION-PROOF, FLAMMABLE MATERIAL STORAGE, & GENERAL-PURPOSE LABORATORY REFRIGERATORS, REFRIGERATOR/FREEZERS, AND FREEZERS

Similar documents
Refrigerators, Refrigerator-Freezers and Freezers

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

HOUSEHOLD FREEZER 048-GM-48303/048-GM-48304/048-GM-48305

Outdoor Beverage Center

2.4 Cu. Ft. Compact Refrigerator

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

Instruction Manual. Chest Freezer. Model: ACFM050ADB INSTALLATION INSTRUCTIONS. Before Using Your Freezer Remove the exterior and interior packing.

DOUBLE DOOR COMPACT REFRIGERATOR. User Manual MODEL:KSTRC312BW KSTRC312BB

Outdoor Refrigerator. Be sure unit is standing upright 24 hours prior to plug-in. Model: BLZ-SSRF-50DH

BULL INSTRUCTION MANUAL. Model Number: BC-130 REFRIGERATOR BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Ui REFRIGERATOR SPEC SHEET

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

Compact Refrigerator Refrigerador compacto Réfrigérateur compact

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

FTM419A01W USER S MANUAL FROST FREE REFRIGERATOR

Outdoor Beverage Center

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

9.9 CU.FT. TOP MOUNT REFRIGERATOR INSTRUCTION MANUAL. Model No.: HVDR1040W HVDR1040B HVDR1040S

Upright Freezer 048-GM-48307

Installation and User's Manual for Refrigerator Model SCR33

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

HT-MOSEL-51D PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE WINE CHILLER

Dual Zone Wine Cellar

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

INSTRUCTION MANUAL. Model Number: DX K Wine Cooler BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

REFRIGERATOR-FREEZER

User Manual / Installation Instructions

200L Chest Freezer / GVATCS20Q. Instruction Manual

Instruction Manual. 4.6 Cu. Ft. Refrigerator/Freezer. Wards.com Wards.com The solution for your cold-storage needs!

An Important Message for Installers and Operators IMPORTANT. Model No. Serial No.

OWNER S MANUAL: Outdoor Refrigerator

OPERATION MANUAL LAB-LINE IMPERIAL III RADIANT HEAT INCUBATORS

QA Passed. Inspired living HRF-253 E. OPERATING MANUAL Refrigerator

FRIGIDAIRE COMMERCIAL FREEZER/REFRIGERATOR GLASS DOOR REFRIGERATOR TABLE OF CONTENTS

SPECIFICATIONS Power Requirements: V, 9.5A, 60Hz V, 5.8A, 50Hz Including 2A for internal convenience outlet.

Instruction Manual MODEL: GDUF Cu. Ft. Capacity 120V~, 60Hz, 115W

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Outdoor/Commercial Refrigerator USER S MANUAL

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

Compact Refrigerator. User's Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE USING YOUR REFRIGERATOR AND KEEP IT FOR FUTURE REFERENCE.

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

3.2 CU FT REFRIGERATOR

Upright Freezer Congélateur vertical Congelador vertical

4.9 CU.FT. BEER KEG COOLER INSTRUCTION MANUAL. Model No.: MCKC490S

User Instruction &)+ 4: CFH110QB

FR120RC/FR120RM FR120RR/FR120RB FN-153/FN-153C

WARNING/SAFETY PRECAUTIONS

Refrigerator / Freezer

G-10f/GCG-10f UPRIGHT COOLER

Outdoor Refrigerator USER S MANUAL

4.3 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

Whynter Stainless Steel 3.2 cu. ft. Indoor / Outdoor Beverage Refrigerator

Hazards or unsafe practices that may result in severe personal injury or death.

Compact Refrigerator. User Manual Model 3590A

Water Boilers ME10EN, ME15EN. Table of Contents

Countertop Refrigerator

ULTRA LOW TEMPERATURE FREEZER. User Manual

INSTRUCTION MANUAL. Model Number : CF-300K, CHEST FREEZER BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

INSTRUCTION MANUAL COMPRESSOR DRIVEN WINE COOLER

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

Electron Microscopy Sciences

VACUUM OVEN. Model: VPX9-2. Installation and Operation Manual

Isotemp Explosion-Proof Refrigerators and Freezers

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

Instruction Manual. Chest Freezer MODEL: KI130CF2

Wine Cooler. Model No. MCWC16MCG MCWC30MCG. CAUTION: Read and follow all safety rules and operating instructions before first use of this product.

Wine Cellar. Instruction Booklet. Model: WC-2038

GCG-26c. Instruction Manual. G-Series Cooler

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

MODULAR REFRIGERATOR. Français p. 16 Español p. 31 ITEM # MODEL #BG179B

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

5.2 Cu. Ft. Chest Freezer

MODEL: 1407, , 1408, & INSTALLATION AND INSTRUCTION MANUAL

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

Bar Fridge USER MANUAL MB46W

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

Haier Three In One. Deep Freezer HDF-325H HDF-385H

Before Putting Into Use. Important. Tips for Energy Savings

HOUSEHOLD REFRIGERATOR-FREEZERS

OWNERS MANUAL CBIR-R CBIR-L

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

Instruction Manual. Beverage and Wine Center. Wards.com Sleek and compact MODEL: GDBC47

INSTRUCTION MANUAL FOR WINE COOLER

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Use and Care Manual. For Beverage Cooler RU

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

REFRIGERATOR with CHILLER COMPARTMENT

TABLE OF CONTENTS. Safety Information...3. Installation Instructions...4. Reverse Refrigerator Door...5. Care and Maintenance... 9

Instruction Manual. Refrigerator. Model: HS-65L

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Transcription:

10/98 OPERATION MANUAL MANUAL NO. 057-196-00 REV. NO. Q LAB-LINE EXPLOSION-PROOF, FLAMMABLE MATERIAL STORAGE, & GENERAL-PURPOSE LABORATORY REFRIGERATORS, REFRIGERATOR/FREEZERS, AND FREEZERS MODEL NOs. 3551 3556 3560 3762 3551-1 3556-1 3560-1 3762-1 3551-10 3556-2 3560-10 3763K 3551-11 3556-4 3560-11 3763B 3552 3556-6 3750 3763-1 3552-1 3557 3750-1 3764 3552-10 3557-1 3750-2 3764-1 3552-11 3557-2 3751 3766 3555 3557-3 3751-1 3766BR3X 3555-1 3557-4 3751BK 3766-1 3555-6 3557-5 3767B 3767 3555-7 3559 3752 3767BR3X 3559-10 3559-1 3752P2 3767R17 3559-11 3752R17 3752-1 3767-1 3764L 3750V 3761 3770 3750K 3763BXK 3761-1 3752-2 3767BR17 3556-6K 3566-1 3566-10 3557-4K 3751R27 3566 3566-11 3551KL 3763(L) 3764K 3751L 3751LFS 3556X 3763XR27 3556-4X LAB-LINE INSTRUMENTS, INC. DESIGNERS AND MANUFACTURERS 15th and Bloomingdale Aves., Melrose Park, IL 60160-1491 USA PHONE: 708/450-2600 1-800/LAB-LINE FAX: 450-0943

TABLE OF CONTENTS 2

SECTION TITLE 1 Introduction 2 Explosion-Proof units 3 Flammable Materials Storage units 4 Corrosion-Resistant units 5 General Purpose Laboratory units 6 Installation 7 Operation 8 Troubleshooting 9 Maintenance 10 Optional Gauge Steel Frame Appliance Dolly 11 Optional Vapor Proof Outlet 12 Replacement Parts Warranty SECTION 1 INTRODUCTION 3

THANK YOU for selecting Lab-Line Instruments for your equipment needs. For maximum value and ease of start-up, PLEASE PROCEED AS FOLLOWS: Inspect the carton and contents for shipping damage. Notify the carrier immediately if damage is found. Use the Accessory Checklist when unpacking to verify that the complete unit has been received. Do not discard packing materials until all is accounted for. Read this Operation Manual thoroughly before deciding upon an appropriate location for the unit: you will want to consider the availability of power, water, hook-ups, drains and other unit requirements, as well as user convenience. Insist that every operator of this unit becomes familiar with the Operation Section of this manual. Be sure to fill out the Warranty Registration Card and mail it in to Lab-Line Instruments within seven (7) days after receiving the unit. IF after reading this manual you should have any difficulties with the installation or operation instructions, please call: Lab-Line Customer Relations Department 708/450-2600 (in Illinois) 1-800/LAB-LINE (elsewhere) ALL RIGHT RESERVED The information contained in this manual is the exclusive property of Lab-Line Instruments, Inc., and has been provided solely to enable the users of the equipment described herein to operate and maintain such equipment. Any other use of this information, or the reproduction or transmission of all or any portion of this manual without prior written consent of the manufacturer is expressly prohibited. 1998, Lab-Line Instruments, Inc. SECTION 2 EXPLOSION-PROOF REFRIGERATORS & FREEZERS 4

BE ADVISED: DANGER: UNLESS UNIT IS SPECIFICALLY DESIGNED FOR COMBUSTIBLE OR FLAMMABLE ATMOSPHERES, DO NOT USE IN THE PRESENCE OF FLAMMABLE OR COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES; DO NOT USE IN THE PRESENCE OF PRESSURIZED OR SEALED CONTAINERS FIRE OR EXPLOSION MAY RESULT CAUSING DEATH. WARNING: DO NOT HEAT ANY SUBSTANCE ABOVE A TEMPERATURE THAT WILL CAUSE IT TO EMIT TOXIC FUMES DEATH OR SEVERE INJURY MAY RESULT. WARNING: BEFORE CONNECTING THE FINAL POWER SUPPLY, CHECK THE ELECTRICAL CHARACTERISTICS OF THE UNIT NAMEPLATE TO SEE THAT IT IS IN AGREEMENT WITH THE POWER SUPPLIED. IN ADDITION, POWER SHOULD BE WIRED TO THE UNIT ACCORDING TO THE ELECTRICAL SCHEMATIC AND ALL APPLICABLE CODES. ONLY QUALIFIED ELECTRICIANS SHOULD WORK ON THE ELECTRICAL PORTION OF ANY UNIT INSTALLATION. CAUTION: SOLUTIONS USED TO CLEAN COILS OR NEUTRALIZE BACTERIA GROWTH MUST NOT BE CORROSIVE TO METALS (ENAMEL-COATED STEEL) AND MATERIALS USED IN THE MAINTENANCE OF THIS EQUIPMENT DAMAGE CAN RESULT: USE A SOFT CLOTH AND WARM WATER TO CLEAN. WARNING: STORAGE BY USER OF ANY MATERIALS IN THE PRODUCT WHICH MAY CAUSE A DETERIORATION OF THE PRODUCT SHALL BE DEEMED TO CONSTITUTE ABNORMAL AND IMPROPER USAGE OF THE PRODUCT FOR PURPOSES OF LAB-LINE S WARRANTY. EXPLOSION-PROOF REFRIGERATORS & FREEZERS: (Con t) SHIPPING CARTON: This should be inspected upon delivery. When received, carefully examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt. 5

Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly. IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly. AN OVERVIEW: THE FULL LINE FROM LAB-LINE: EXPLOSION-PROOF REFRIGERATORS AND FREEZERS. Conventional refrigerators and freezers are not only unsuitable for storing flammable materials, they can create potential hazards in a facility. Such units have several components in their electrical and refrigeration systems which can trigger explosions of flammable air-vapor mixtures inside the unit or from the immediate surrounding area. Lab-Line offers the largest explosion-proof selection in the industry, including single and 2-door upright refrigerators and freezers, horizontal chest freezers, and undercounter refrigerators. Motors and thermostats are designed to prevent the arcing which can ignite a flammable air-vapor mixtures, In addition, each unit has wiring, splices, a thermostat, a relay and a compressor motor safely housed within an explosionproof enclosure of construction suitable for use in Class I, Groups C and D. This means that things like the surface temperature of compressors will remain below the flashpoint of any flammable material likely to be found in Class I, Groups C and D locations. All models have heavy-gauge, rigid, braced-steel construction with a durable enamel finish. Interiors have epoxy enamel or ABS plastic construction. Each unit is insulated throughout for energy-efficient operation. These Lab-Line units will prevent potentially destructive explosions in any facility by meeting the standards established by Underwriters Laboratory, Inc., OSHA and National Fire Protection Association for storage of hazardous materials. Lab-Line Explosion-Proof Refrigerators and Freezers are 100% explosionproof. They also meet National Fire Protection Standards as found in Articles 500-501 and provide total protection while storing reagents at or below ambient temperatures. 6

EXPLOSION-PROOF REFRIGERATORS/FREEZERS: (Con t) Explosion-proof models are specifically designed and engineered to prevent the triggering of an explosion inside or outside of the unit in a Class I, Groups C and D hazardous material environment. These models feature stainless steel refrigeration components that are more resistant to attack from corrosive vapors than are aluminum or epoxycoated aluminum. It is important to note that Explosion-Proof models must be connected to the power supply source by rigid metal conduit or mineral-insulated cable with proper fittings suitable for Class I, Groups C and D hazardous locations. In addition, the wires inside the conduit must be sealed. All units carry a 12 month warranty. 7

EXPLOSION-PROOF UNITS: (Con t) MODEL 3551/-1 23¼ WIDE 2-DOOR REFRIGERATOR/FREEZER: FEATURES: ADJUSTABLE NATURAL AIR FLOW VENT OVERALL 11 CU. FT. MANUAL DEFROST 3 ADJUSTABLE SHELVES ABS PLASTIC INTERIOR 4 DOOR SHELVES WHITE COLOR HYDRAULIC THERMOSTAT TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3551 41½ H X 20¾ W X 14 D 12¾ H X 19 W X 15 D 11 63 H X 23¼ W X 24½ D (105 X 53 X 36 cm) (32 X 48 X 38 cm) (160 X 59 X 62 cm) 3551-1 41½ H X 20¾ W X 14 D 12¾ H X 19 W X 15 D 11 63 H X 23¼ W X 24½ D (105 X 53 X 36 cm) (32 X 48 X 38 cm) (160 X 59 X 62 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3551 120/60 360 3.0 0º to 10º -20 to -0º 120 150 (32º to 50º) (-4º to 32º) (54.5) (68.2) 3551-1 240/50 360 1.5 0º to 10º -20 to -0º 120 150 (32º to 50º) (-4º to 32º) (54.5) (68.2) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. EXPLOSION-PROOF UNITS: (Con t) 8

MODEL 3552/-1 32 WIDE 1-DOOR UPRIGHT FREEZER: FEATURES: OVERALL 20 CU. FT. BUILT-IN, EVEN-COOLING SHELVES 4 PERMANENTLY POSITIONED WIRE SHELVES LOCKING DOOR MANUAL DEFROST WHITE COLOR TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3552 57 H X 27 W X 18 D 20 71½ H X 32 W X 33 D (149 X 69X 46 cm) (181 X 81 X 84 cm) 3552-1 57 H X 27 W X 18 D 20 71½ H X 32 W X 33 D (149 X 69X 46 cm) (181 X 81 X 84 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3552 120/60 516 4.3-23º to -5º 225 240 (-9 º to 23º) (102.3) (109.1) 3552-1 240/50 516 2.1-23º to -5º 225 240 (-9 º to 23º) (102.3) (109.1) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. EXPLOSION-PROOF UNITS: (Con t) MODEL 3555/-1 MODEL 3555-6 MODEL 3555-7 9

60¼ WIDE 31½ WIDE 31½ WIDE CHEST FREEZER: CHEST FREEZER: CHEST FREEZER: FEATURES: FEATURES: FEATURES: OVERALL 18 CU. FT. OVERALL 6.0 CU. FT. OVERALL 6.0 CU. FT. KEY LOCK KEY LOCK KEY LOCK STORAGE BASKET STORAGE BASKET STORAGE BASKET KEYLOCK LID KEYLOCK LID KEYLOCK LID MANUAL DEFROST MANUAL DEFROST MANUAL DEFROST WHITE COLOR WHITE COLOR WHITE COLOR EXPLOSION-PROOF UNITS: (Con t) TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS 10

MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3555 28 H X 50¼ W X 22¼ D 18 35 H X 60¼ W X 29½ D (71X 128 X 57 cm) (89 X 153 X 75 cm) 3555-1 28 H X 50¼ W X 22¼ D 18 35 H X 60¼ W X 29½ D (71X 128 X 57 cm) (89 X 153 X 75 cm) 3555-6 28 H X 26¼ W X 16½ D 6 35 H X 35 W X 26¼ D (71 X 67X 42 cm) (89 X 80X 67 cm) 3555-7 28 H X 26¼ W X 16½ D 6 35 H X 35 W X 26¼ D (71 X 67X 42 cm) (89 X 80X 67 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3555 120/60 516 4.3-28º to -18º 185 200 (-18º to 0º) (84.1) (90.9) 3555-1 240/50 516 2.1-28º to -18º 185 200 (-18º to 0º) (84.1) (90.9) 3555-6 120/60 276 2.3-21º to -4º 95 125 (-5 to 24º) (43) (57) 3555-7 240/50 276 1.1-21º to -4º 95 125 (-5 to 24º) (43) (57) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. 11

EXPLOSION-PROOF UNITS: (Con t) MODEL 3557 MODEL 3557-2 MODEL 3557-4 & 3557-1 & 3557-3 & 3557-5 23-1/3 WIDE, 21¼ WIDE 21¼ WIDE UNDER-COUNTER UNDERCOUNTER UNDERCOUNTER REFRIGERATOR FREEZER: REFRIGERATOR/FREEZER: KEY LOCK: FEATURES: FEATURES: FEATURES: COLD-WALL DESIGN ADJUSTABLE THERMOSTAT 1-PIECE SEAMLESS INTERIOR AMPLE DOOR STORAGE MAGNETIC GASKET 2 RUSTPROOF, SLIDE-OUT ADJUSTABLE THERMOSTAT HERMETICALLY-SEALED SHELVES REAR ROLLERS COMPRESSOR ADJUSTABLE FOOT FRONT LEGS LEVEL-ADJUST OFF CYCLE DEFROST DRIP TRAY MAGNETIC GASKET WHITE COLOR MANUAL DEFROST STURDY METAL HINGES WHITE COLOR SEAMLESS 1-PIECE POLYPROPYLENE LINER WHITE COLOR 1 GLASS SHELF 3557 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAY BE INSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIR FLOW IS PROVIDED IT IS SUGGESTED THE UNIT BE RECESSED ONLY 21 TO PERMIT EASY ACCESS TO THE LOCK. 3557-4 & 3557-5 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAY BE ENCLOSED ONLY IF SUFFICIENT SPACE IS PROVIDED FOR PROPER VENTILATION 1 ON THE SIDES, TOP AND REAR, ARE RECOMMENDED. EXPLOSION-PROOF UNITS: (Con t) 12

TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3557 27-½ H X 19 W X 13 D 5.6 33½ H X 23½ W X 23¾ D (70 X 48 X 33 cm) (85 X 59 X 60 cm) 3557-1 27-½ H X 19 W X 13 D 5.6 33½ H X 23½ W X 23¾ D (70 X 48 X 33 cm) (85 X 59 X 60 cm) 3557-2 27½ Hx18 Wx15 D 5.6 33½ H X 21¼ W X 25¼ D (70 X 46 X 38 cm) (85 X 54 X 64 cm) 3557-3 27½ Hx18 Wx15 D 5.6 33½ H X 21¼ W X 25¼ D (70 X 46 X 38 cm) (85 X 54 X 64 cm) 3557-4 21 HX18 WX15¼ D 5¼ H X 15¼ W X 11 D 5.6 33½H X 21¼ W X 25¼ D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 54 X 64 cm) 3557-5 21 HX18 WX15¼ D 5¼ H X 15¼ W X 11 D 5.6 33½H X 21¼ W X 25¼ D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 54 X 64 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3557 120/60 160 1.3 2º to 7º 100 120 (36º to 45º) (45.3) (54.5) 3557-1 240/50 160 0.66 2º to 7º 100 120 (36º to 45º) (45.3) (54.5) 3557-2 120/60 200 1.6-26º to -15º 100 125 (-15º to 5º) (45.3) (54.5) 3557-3 240/50 200 0.83-26º to -15º 100 120 (-15º to 5º) (45.3) (54.5) 3557-4 120/60 160 1.3 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21º) (45.3) (54.5) 3557-5 240/50 160 0.66 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21º) (45.3) (54.5) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. EXPLOSION-PROOF UNITS: (Con t) 13

MODEL 3559/-1 23 WIDE, SINGLE-DOOR REFRIGERATOR/FREEZER: FEATURES: 3 ADJUSTABLE SHELVES 4 DOOR SHELVES ADJUSTABLE THERMOSTAT MANUAL DEFROST WHITE COLOR TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3559 32 H X 19¾ W X 17½ D 8 H X 17¼ W X 12 D 10 58 H X 23 W X 23½ D (83X 50X 45 cm) (20 X 44 X 30 cm) (147 X 58 X 60 cm) 3559-1 32 H X 19¾ W X 17½ D 8 H X 17¼ W X 12 D 10 58 H X 23 W X 23½ D (83X 50X 45 cm) (20 X 44 X 30 cm) (147 X 58 X 60 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3559 120/60 360 3.0 1º to 10º -17º to -6º 120 150 (34º to 50º) (-1º to 21º) (54.5) (68.2) 3559-1 240/50 360 1.5 1º to 10º -17º to -6º 120 150 (34º to 50º) (-1º to 21º) (54.5) (68.2) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHE LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. EXPLOSION-PROOF UNITS: (Con t) MODEL 3566/-1: 32 WIDE, 1-DOOR, REFRIGERATOR : 14

FEATURES: COPPER EVAPORATOR COIL REFRIGERATION COMPONENTS OVERALL 20 CU. FT. 5 ADJUSTABLE SHELVES TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3566 55 H X 27 W X 20 D 20 71½ H X 32 W X 28½ D (140 X 69 X 51 cm) (182 X 81 X 72 cm) 3566-1 55 H X 27 W X 20 D 20 71½ H X 32 W X 28½ D (140 X 69 X 51 cm) (182 X 81 X 72 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3566 120/60 480 4-5º to 15º 240 280 (23º to 9º) (109) (127) 3566-1 240/60 480 2-5º to 15º 240 280 (23º to 9º) (109) (127) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. 15

SECTION 3 FLAMMABLE MATERIALS STORAGE REFRIGERATORS & FREEZERS SHIPPING CARTON: This should be inspected upon delivery. When received, carefully examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt. Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly. IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly. AN OVERVIEW: THE FULL LINE FROM LAB-LINE: FLAMMABLE MATERIAL STORAGE REFRIGERATORS AND FREEZERS. These Lab-Line units will prevent potentially destructive explosions in any facility by meeting the standards established by Underwriters Laboratory, Inc., OSHA and National Fire Protection Association for storage of hazardous materials. They also are designed to comply with National Fire Protection Association Standards Nos. 45 and 99, as well as OSHA Article No. CFR 1910.308. Lab-Line Flammable Materials Storage Refrigerators/Freezers are manufactured for safe, cold storage of volatile materials. Flammable Material Storage (FMS) Refrigerators/Freezers will prevent an explosion from occurring inside the unit. These units have no internal electrical components which could trigger an explosion of hazardous materials inside the unit. (They are NOT designed for use in Class I, Groups C and D environments for these locations use a Lab-Line Explosion-Proof Refrigerator.) However, FMS units are not suitable for use in Class I, Group C and D environments. This complete line includes single and 2-door upright refrigerators and freezers, horizontal chest freezers, and undercounter refrigerators. FLAMMABLE MATERIALS STORAGE 16

REFRIGERATORS & FREEZERS: (Con t) These units are ideal for storing cyclopropane, ethyl ether, ethylene, acetone, alcohol, benzene, butane, gasoline, hexane, lacquer solvent vapors, naphtha, natural gas or propane along with many other potentially hazardous materials. All cabinets have heavy-gauge steel construction with a durable exterior finish of epoxy enamel. A well insulated cabinet and tight sealing magnetic door prevent air leaks along with helping to lower operating costs. The interior is made of porcelain enameled steel or ABS plastic. Lab-Line offers the largest selection of FMS units. All models are delivered with 3-wire line cord and molded plug. All 120 volt FMS models are UL Listed. All units carry a 12 month warranty. FLAMMABLE MATERIAL STORAGE 17

UNITS: MODEL 3551-10/-11 20¾ WIDE 2-DOOR REFRIGERATOR/FREEZER: FEATURES: OVERALL 11 CU. FT. 4 ADJUSTABLE THERMOSTAT ABS PLASTIC INTERIOR MANUAL DEFROST WHITE COLOR NOTE: IN ORDER FOR FREEZER TO REACH -20ºC, VENT ON INSIDE UPPER REAR OF REFRIGERATOR MUST BE CLOSED. TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3551-10 41½ H X 20¾ W X 14 D 12¾ H X 19 W X 15 D 11 63 H X 23¼ W X 24½ D (105 X 53 X 36 cm) (32 X 48 X 38 cm) (160 X 59 X 62 cm) 3551-11 41½ H X 20¾ W X 14 D 12¾ H X 19 W X 15 D 11 63 H X 23¼ W X 24½ D (105 X 53 X 36 cm) (32 X 48 X 38 cm) (160 X 59 X 62 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3551-10 120/60 360 3.0 0º to 10º -20º to -0º 120 150 (32º to 50º) (-4º to 32º) (54.5) (68.2) 3551-11 240/50 360 1.5 0º to 10º -20º to -0º 120 150 (32º to 50º) (-4º to 32º) (54.5) (68.2) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. FLAMMABLE MATERIAL STORAGE UNITS: 18

MODEL 3552-10/11 32 WIDE 1-DOOR UPRIGHT FREEZERS: FEATURES: OVERALL 20 CU. FT. 4 PERMANENT WIRE SHELVES 6 DOOR SHELVES ENAMELED STEEL INTERIOR WITH ABS PLASTIC LOCKING DOOR MANUAL DEFROST WHITE COLOR TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3552-10 57 H X 27 W X 18 D 20 71½ H X 32 W X 33 D (145 X 69 X 46 cm) (182 X 81 X 84 cm) 3552-11 57 H X 27 W X 18 D 20 71½ H X 32 W X 33 D (145 X 69 X 46 cm) (182 X 81 X 84 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3552-10 120/60 516 4.3-23º to -5º 225 240 (-9º to 23º) (102.3) (109.1) 3552-11 240/50 516 2.1-23º to -5º 225 240 (-9º to 23º) (102.3) (109.1) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. FLAMMABLE MATERIAL STORAGE UNITS: 19

MODEL 3556(X)/-1 MODEL 3556-4 MODEL 3556-6 COMPACT 23-3/8 WIDE, 18¼ WIDE 21¼ WIDE NO-FROST FRONT-OPENING REFRIGERATOR/FREEZER: UNDERCOUNTER FREEZER: ALL-REFRIGERATOR KEY LOCK: FEATURES: FEATURES: FEATURES: COLD-WALL DESIGN ADJUSTABLE THERMOSTAT 1-PIECE SEAMLESS INTERIOR AMPLE DOOR STORAGE MAGNETIC GASKET 2 RUSTPROOF, SLIDE-OUT ADJUSTABLE THERMOSTAT HERMETICALLY-SEALED SHELVES REAR ROLLERS COMPRESSOR 3 IN-DOOR RACKS FRONT LEGS LEVEL-ADJUST OFF CYCLE DEFROST ADJUSTABLE FOOT MAGNETIC GASKET WHITE COLOR DRIP TRAY STURDY METAL HINGES MANUAL DEFROST SEAMLESS 1-PIECE WHITE COLOR POLYPROPYLENE LINER WHITE COLOR 1 GLASS SHELF 3556(X)/-1 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAY BE INSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIR FLOW IS PROVIDED IT IS SUGGESTED THE UNIT BE RECESSED ONLY 21 TO PERMIT EASY ACCESS TO THE LOCK. 3556-6 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAY BE ENCLOSED ONLY IF SUFFICIENT SPACE IS PROVIDED FOR PROPER VENTILATION 1 ON THE SIDES, TOP AND REAR, ARE RECOMMENDED. FLAMMABLE MATERIAL STORAGE UNITS: (Con t) TOTAL 20

CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3556 27½ H X 19 W X 13 D 5.6 33½ H X 23½ W X 23¾ D (70 X 48 X 33 cm) (85 X 59 X 60 cm) 3556-1 27½ H X 19 W X 13 D 5.6 33½ H X 23½ W X 23¾ D (70 X 48 X 33 cm) (85 X 59 X 60 cm) 3556-4 27½ H X 18 W X 15 D 5.6 33½ H X 21¼ W X 25¼ D (70 X 46 X 38 cm) (85 X 54 X 64 cm) 3556-6 21 H X 18 W X 15¼ D 5¼ H X 15¼ W X 11 D 5.6 33½ H X 21¼ W X 25¼ D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 54 X 64 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3556 120/60 160 1.3 2º to 7º 100 120 (36º to 45º) (45.5) (54.5) 3556-1 240/50 160.66 2º to 7º 100 120 (36º to 45º) (45.5) (54.5) 3556-4 120/60 200.60-26º to 15º 100 120 (15 to 32) (45.5) (54.5) 3556-6 120/60 160 1.3 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21º) (45.5) (54.5) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. FLAMMABLE MATERIAL STORAGE UNITS: (Con t) MODEL 3559-10/-11 24 WIDE, SINGLE-DOOR REFRIGERATOR/FREEZER: 21

FEATURES: 3 ADJUSTABLE SHELVES 4 DOOR SHELVES ADJUSTABLE THERMOSTAT MANUAL DEFROST ABS PLASTIC INTERIOR WHITE COLOR TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3559-10 32 H X 19¾ W X 17½ D 8 H X 17¼ W X 12 D 10 58 H X 23 W X 23½ D (83 X 50 X 45 cm) (20 X 44 X 31 cm) (147 X 58 X 60 cm) 3559-11 32 H X 19¾ W X 17½ D 8 H X 17¼ W X 12 D 10 58 H X 23 W X 23½ D 83 X 50 X 45 cm) (20 X 44 X 31 cm) (147 X 58 X 60 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3559-10 120/60 360 3.0 1º to 10º -17º to -6º 120 150 (34º to 50º) (1º to 21.º) (54.5) (68.2) 3559-11 240/50 360 1.5 1º to 10º -17º to -6º 120 150 (33.8º to 50º) (1º to 21º) (54.5) (68.2) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. FLAMMABLE MATERIAL STORAGE UNITS: (Con t) MODEL 3566-10/-11: 32 WIDE, 1-DOOR, REFRIGERATOR : FEATURES: ALUMINUM EVAPORATOR COIL REFRIGERATION COMPONENTS OVERALL 20 CU. FT. 22

5 ADJUSTABLE SHELVES TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3566-10 55 H X 27 W X 20 D 20 71½ H X 32 W X 28½ D (140 X 69 X 51 cm) (182 X 81 X 72 cm) 3566-11 55 H X 27 W X 20 D 20 71½ H X 32 W X 28½ D (140 X 69 X 51 cm) (182 X 81 X 72 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3566-10 120/60 480 4-5º to 15º 240 280 (23º to 9º) (109) (127) 3566-11 240/60 480 2-5º to 15º 240 280 (23º to 9º) (109) (127) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. SECTION 4 CORROSION-RESISTANT REFRIGERATORS/FREEZERS BE ADVISED: DANGER: UNLESS UNIT IS SPECIFICALLY DESIGNED FOR COMBUSTIBLE OR FLAMMABLE ATMOSPHERES, DO NOT USE IN THE PRESENCE OF FLAMMABLE 23

OR COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES; DO NOT USE IN THE PRESENCE OF PRESSURIZED OR SEALED CONTAINERS FIRE OR EXPLOSION MAY RESULT CAUSING DEATH. WARNING: DO NOT HEAT ANY SUBSTANCE ABOVE A TEMPERATURE THAT WILL CAUSE IT TO EMIT TOXIC FUMES DEATH OR SEVERE INJURY MAY RESULT. WARNING: BEFORE CONNECTING THE FINAL POWER SUPPLY, CHECK THE ELECTRICAL CHARACTERISTICS OF THE UNIT NAMEPLATE TO SEE THAT IT IS IN AGREEMENT WITH THE POWER SUPPLIED. IN ADDITION, POWER SHOULD BE WIRED TO THE UNIT ACCORDING TO THE ELECTRICAL SCHEMATIC AND ALL APPLICABLE CODES. ONLY QUALIFIED ELECTRICIANS SHOULD WORK ON THE ELECTRICAL PORTION OF ANY UNIT INSTALLATION. CAUTION: SOLUTIONS USED TO CLEAN COILS OR NEUTRALIZE BACTERIA GROWTH MUST NOT BE CORROSIVE TO METALS (ENAMEL-COATED STEEL) AND MATERIALS USED IN THE MAINTENANCE OF THIS EQUIPMENT DAMAGE CAN RESULT: USE A SOFT CLOTH AND WARM WATER TO CLEAN. 24

CORROSION-RESISTANT REFRIGERATORS/FREEZERS: (Con t) SHIPPING CARTON: This should be inspected upon delivery. When received, carefully examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt. Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly. IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly. AN OVERVIEW: THE FULL LINE FROM LAB-LINE: CORROSION- RESISTANT REFRIGERATORS AND FREEZERS. Aluminum or epoxy-coated refrigeration components are susceptible to attack by caustic materials and strong acids. These components will corrode, and, as a result, will leak allowing Freon to escape. This inevitably causes the compressor to fail. Lab-Line units eliminate these problems by utilizing stainless steel condensing coils, evaporators and shelves. Units come 5 shelves (depending on model) which are adjustable on 1 centers, along with a storage basket. Units can be utilized either as a freezer or refrigerator. They can include porcelain enamel interior and stainless steel door liners for improved corrosion resistance over ABS plastic or enameled steel. A locking door is standard. Both explosion-proof and flammable material storage versions are available. All units carry a 12 month warranty. CORROSION-RESISTANT UNITS: 25

MODEL 3560/-1/-10/-11: 32 WIDE, 1-DOOR, REFRIGERATOR : FEATURES: ALUMINUM OR EPOXY COATED PORCELAIN ENAMEL INTERIOR REFRIGERATION COMPONENTS STAINLESS STEEL DOOR LINER OVER ABS PLASTIC OR OVERALL 20 CU. FT. ENAMELED STEEL 6 ADJUSTABLE SHELVES (ON 1 KEY LOCK CENTERS) WHITE COLOR MANUAL DEFROST TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3560 55 H X 27 W X 20 D 20 71½ H X 32 W X 28½ D (140 X 69 X 51 cm) (182 X 81 X 72 cm) 3560-1 55 H X 27 W X 20 D 20 71½ H X 32 W X 28½ D (140 X 69 X 51 cm) (182 X 81 X 72 cm) 3560-10 55 H X 27 W X 20 D 20 71½ H X 32 W X 28½ D (140 X 69 X 51 cm) (182 X 81 X 72 cm) 3560-11 55 H X 27 W X 20 D 20 71½ H X 32 W X 28½ D (140 X 69 X 51 cm) (182 X 81 X 72 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3560 120/60 480 4-5º to 15º 240 280 (23º to 9º) (109.1) (127.3) 3560-1 240/60 480 2-5º to 15º 240 280 (23º to 9º) (109.1) (127.3) 3560-10 120/60 480 4-5º to 15º 240 280 (23º to 9º) (109.1) (127.3) 3560-11 240/50 480 2-5º to 15º 240 280 (23º to 9º) (109.1) (127.3) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. 26

SECTION 5 GENERAL-PURPOSE LABORATORY REFRIGERATORS/FREEZERS BE ADVISED: DANGER: UNLESS UNIT IS SPECIFICALLY DESIGNED FOR COMBUSTIBLE OR FLAMMABLE ATMOSPHERES, DO NOT USE IN THE PRESENCE OF FLAMMABLE OR COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES; DO NOT USE IN THE PRESENCE OF PRESSURIZED OR SEALED CONTAINERS FIRE OR EXPLOSION MAY RESULT CAUSING DEATH. WARNING: DO NOT HEAT ANY SUBSTANCE ABOVE A TEMPERATURE THAT WILL CAUSE IT TO EMIT TOXIC FUMES DEATH OR SEVERE INJURY MAY RESULT. WARNING: BEFORE CONNECTING THE FINAL POWER SUPPLY, CHECK THE ELECTRICAL CHARACTERISTICS OF THE UNIT NAMEPLATE TO SEE THAT IT IS IN AGREEMENT WITH THE POWER SUPPLIED. IN ADDITION, POWER SHOULD BE WIRED TO THE UNIT ACCORDING TO THE ELECTRICAL SCHEMATIC AND ALL APPLICABLE CODES. ONLY QUALIFIED ELECTRICIANS SHOULD WORK ON THE ELECTRICAL PORTION OF ANY UNIT INSTALLATION. CAUTION: SOLUTIONS USED TO CLEAN COILS OR NEUTRALIZE BACTERIA GROWTH MUST NOT BE CORROSIVE TO METALS (ENAMEL-COATED STEEL) AND MATERIALS USED IN THE MAINTENANCE OF THIS EQUIPMENT DAMAGE CAN RESULT: USE A SOFT CLOTH AND WARM WATER TO CLEAN. 27

GENERAL-PURPOSE LABORATORY REFRIGERATORS/FREEZERS: (Con t) SHIPPING CARTON: This should be inspected upon delivery. When received, carefully examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt. Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly. IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly. AN OVERVIEW: THE FULL LINE FROM LAB-LINE: GENERAL-PURPOSE LABORATORY COOL-LAB ALL-REFRIGERATORS, REFRIGERATOR/ FREEZER AND ALL-FREEZER MODELS. There are undercounter, upright, along with one- and two-door model refrigerators. All-freezer units features chest, upright and undercounter models. Features can include white, textured steel cabinet, seamless ABS plastic liner, magnetic door latch(s), polyurethane insulation, rust-proof shelving. Depending upon the model required, additional features are available. X MODEL: OPTIONAL THERMOMETER/TEMPERATURE ALARM Modes designated with an X come with a fully digital thermometer/ temperature alarm. Though factory-calibrated the unit can be recalibrate, set every function with a common blunt-point pencil or ballpoint pen. Operation: Thermometer: Temperature range -58º to +230ºF, or -40ºC to + 110ºC, with an accuracy to ±2ºF or 1ºC. Continuous temperature readout to 1 degree; Alarm Mode: Siren alarm and blinking LED warn when temperature passes pre-set critical points for more than 15 minutes. Power-Failure Alarm: LED display goes out and siren sounds for a minimum of 12 hours. Pre-Set Delay: 15-minute delay prevents siren sounding during normal door operation or system cycling. Specifications: Power supply is 110-115V AC external transformer. 28

COOL-LAB GENERAL-PURPOSE LABORATORY UNITS: (Con t) MODEL 3750/-1/-2 18¾ WIDE 23-3/8 WIDE REFRIGERATOR/FREEZER: UNDER-COUNTER FREEZER: MODEL 3751(R27)/-1, 3571B FEATURES: 1-PIECE SEAMLESS INTERIOR 2 RUSTPROOF, SLIDE OUT SHELVES 3 IN-DOOR SHELVES ADJUSTABLE FOOT DRIP TRAY MANUAL DEFROST WHITE COLOR FEATURES: ABS PLASTIC INTERIOR 4 ADJUST-SHELVES ADJUSTABLE THERMOSTAT MAGNETIC DOOR GASKET WHITE COLOR KEY LOCK 1 GLASS SHELF 3750 & 3571 NOTE: THIS UNIT IS DESIGNED FOR FREE STANDING INSTALLATION ONLY. IT MAY BE INSTALLED UNDER A COUNTER ONLY IF SUFFICIENT SPACE FOR AIR FLOW IS PROVIDED. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. COOL-LAB 29

GENERAL-PURPOSE LABORATORY UNITS: (Con t) TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3750 21 H X 18 W X 15¼ D 5¼ H X 15¼ W X 11 D 5.6 33½ HX 21¼ W X 25¼ D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 54 X 64 cm) 3750-1 21 H X 18 W X 15¼ D 5¼ H X 15¼ W X 11 D 5.6 33½ HX23-1/3 WX23-3/4 D (53 X 46 X 39 cm) (13 X 39 X 28 cm) (85 X 59 X 60 cm) 3750-2 23½ H X 18¾ W X 20 D 5½ H X 15-3/8 W X 11 D 5.5 33 H X 21¼ W X 26 D (59.6 X 47.6 X 50.8 cm) (13.9 X 39.1 X 27.9 cm) (83.8 X 53.9 X 66.0 cm) 3751 27½ H X19 W X 13 D 5.6 33-1/3 H X 23-1/3 W X 23¾ D (70 X 48 X 33 cm) (85 X 59 X 60 cm) 3751-1 27½ H X19 W X 13 D 5.6 33-1/3 H X 23-1/3 W X 23¾ D (70 X 48 X 33 cm) (85 X 59 X 60 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3750 120/60 160 1.3 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21.2º) (45.3) (54.5) 3750-1 240/50 160 0.66 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21.2º) (45.3) (54.5) 3750-2 240/60 160 0.66 2º to 7º -26º to -6º 100 120 (36º to 45º) (-15º to 21.2º) (45.3) (54.5) 3751 120/60 160 1.3 2º to 7º 100 120 (36º to 45º) (45.5) (54.5) 3751-1 240/50 200 0.8 2º to 7º 100 120 (36º to 45º) (45.5) (54.5) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. COOL-LAB GENERAL-PURPOSE LABORATORY 30

UNITS: (Con t) MODEL 3752/-2 21¼ WIDE UNDER-COUNTER FREEZER: FEATURES: ADJUSTABLE THERMOSTAT MAGNETIC GASKET HERMETICALLY-SEALED COMPRESSOR MANUAL DEFROST WHITE COLOR TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3752 27½ H X 18 W X 15 D 5.6 33½ H X 21¼ W X 25¼ D (70 X 46 X 38 cm) (85 X 54 X 64 cm) 3752-2 27½ H X 18 W X 15 D 5.6 33½ H X 21¼ W X 25¼ D (70 X 46 X 38 cm) (85 X 54 X 64 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3752 120/60 200 1.6-26º to -15º 100 120 (-15º to 5º) (45.5) (54.5) 3752-2 240/50 200 0.8-26º to -15º 100 120 (-15º to 5º) (45.5) (54.5) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. COOL-LAB GENERAL-PURPOSE LABORATORY UNITS: (Con t) 31

MODEL 3761/-1 MODEL 3762/-1 31½ WIDE 60¼ WIDE TOP-OPENING TOP-OPENING CHEST FREEZER: CHEST FREEZER: FEATURES: KEY LOCKING COVER STORAGE BASKET KEYLOCK LID MANUAL DEFROST WHITE COLOR FEATURES: KEY LOCKING COVER STORAGE BASKET KEYLOCK LID MANUAL DEFROST WHITE COLOR COOL-LAB GENERAL-PURPOSE LABORATORY UNITS: (Con t) TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS 32

MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3761 28 H X 26¼ W X 16½ D 6.0 35 H X 31½ W X 24¼ D (71 X 67 X 42 cm) (89 X 80X 67 cm) 3761-1 28 H X 26¼ W X 16½ D 6.0 35 H X 31½ W X 24¼ D (71 X 67 X 42 cm) (89 X 80X 67 cm) 3762 28 H X 50¼ W X 22¼ D 18.0 35 H X 60¼ W X 29½ D (71 X 128 X 57 cm) (89 X 153 X 75 cm) 3762-1 28 H X 50¼ W X 22¼ D 18.0 35 H X 60¼ W X 29½ D (71 X 128 X 57 cm) (89 X 153 X 75 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3761 120/60 276 1.5-21º to -4º 95 125 (-5º to 24º) (43.2) (56.8) 3761-1 240/50 276 0.9-21º to -4º 95 125 (-5º to 24º) ((43.2) (56.8) 3762 120/60 516 4.3-28º to -18º 185 200 (-18º to 0º) (84.1) (90.9) 3762-1 240/50 516 2.1-28º to -18º 185 200 (-18º to 0º) (84.1) (90.9) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. COOL-LAB GENERAL-PURPOSE LABORATORY UNITS: (Con t) MODELS 3763, 3763B 3763BXK, 3763-1 MODEL 3764/-1 28 WIDE 23 WIDE 2-DOOR SINGLE-DOOR 33

REFRIGERATOR/FREEZER: REFRIGERATOR/FREEZER: FEATURES: 2 DOOR SHELVES ADJUSTABLE THERMOSTAT MAGNETIC DOOR GASKET AUTOMATIC DEFROST WHITE COLOR FEATURES: 3 ADJUSTABLE SHELVES MANUAL DEFROST WHITE COLOR 3763B: OPTIONAL THERMOMETER/TEMPERATURE ALARM Modes designated with an B come with a fully digital thermometer/ temperature alarm. Though factory-calibrated the unit can be recalibrated with every function being set with a common blunt-point pencil or ballpoint pen. Operation: Thermometer: Temperature range -58º to +230ºF, or -40ºC to + 110ºC, with an accuracy to ±2ºF or 1ºC. Continuous temperature readout to 1 degree; Alarm Mode: Siren alarm and blinking LED warn when temperature passes pre-set critical points for more than 15 minutes. Power-Failure Alarm: LED display goes out and siren sounds for a minimum of 12 hours. Pre-Set Delay: 15-minute delay prevents siren sounding during normal door operation or system cycling. Specifications: Power supply is 110-115V AC external transformer. 3763BXK: DUAL THERMOMETER/TEMPERATURE ALARM WITH DUAL KEY LOCKS This unit is similar to the one above except it offers a separate key lock and temperature alarm with probe for both the refrigerator and freezer section. COOL-LAB GENERAL-PURPOSE LABORATORY UNITS: (Con t) TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3763 36½ H X 25 W X 15½ D 15¼ H X 24 W X 16 D 14.0 61½ H X 28 W X 28 D (93 X 64 X 39 cm) (39X 61 X 41 cm) (156 X 71 X 71 cm) 34

3763-1 36½ H X 25 W X 15½ D 15¼ H X 24 W X 16 D 14.0 61½ H X 28 W X 28 D (93 X 64 X 39 cm) (39X 61 X 41 cm) (156 X 71 X 71 cm) 3764 32 H X 19¾ W X 17½ D 8 H X 17¼ W X 12 D 10.0 58 H X 23 W X 23½ D (81 X 50 X 45 cm) (20 X 44 X 31 cm) (147 X 58 X 60 cm) 3764-1 32 H X 19¾ W X 17½ D 8 H X 17¼ W X 12 D 10.0 58 H X 23 W X 23½ D (81 X 50 X 45 cm) (20 X 44 X 31 cm) (147 X 58 X 60 cm) NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3763 120/60 420 3.5 0º to 10º -20º to 0º 170 190 (32º to 50º) (-4º to 32º) (77.3) (86.4) 3763-1 240/50 420 1.7 0º to 10º -20º to 0º 170 190 (32º to 50º) (-4º to 32º) (77.3) (86.4) 3764 120/60 360 3.0 1º to 10º -17º to -6º 120 150 (34º to 50º) (-1º to 21 º) (54.5) (68.24) 3764-1 240/50 360 1.5 1º to 10º -17º to -6º 120 150 (34º to 50º) (-1º to 21 º) (54.5) (68.24) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. COOL-LAB GENERAL-PURPOSE LABORATORY UNITS: (Con t) MODEL 3766/-1 MODEL 3767/-1 MODEL 3770 32 WIDE 32 WIDE 18½ WIDE 1-DOOR UPRIGHT BENCH TOP ALL-REFRIGERATOR: FREEZER: REFRIGERATOR/FREEZER: FEATURES: FEATURES: FEATURES: OVERALL 20 CU. FT. OVERALL 20 CU. FT. OVERALL 1.9 CU. FT. FROST-FREE 6 DOOR SHELVES REMOVABLE SHELF 5 ADJUSTABLE SHELVES ENAMELED STEEL INTERIOR MANUAL DEFROST ON 1 CENTERS KEY LOCK WHITE COLOR 35

1 STORAGE BASKET ADJUSTABLE THERMOSTAT AUTOMATIC DEFROST WHITE COLOR MANUAL DEFROST WHITE COLOR 3770 NOTE: ALLOW THE FOLLOWING CLEARANCE: TOP, 12"; BACK, 5"; SIDES, ½". GENERAL-PURPOSE LABORATORY UNITS: (Con t) TOTAL CHAMBER DIMENSIONS VOL. EXTERIOR H X W X D (CM) (CU. DIMENSIONS MODEL REFRIGERATOR FREEZER FT.) H X W X D (CM) 3766 57 H X 27 W X 17¾ D 20 71 H X 32 W X 28½ D (145 X 69 X 45 cm) (180 X 81 X 72 cm) 3766-1 57 H X 27 W X 17¾ D 20 71 H X 32 W X 28½ D (145 X 69 X 45 cm) (180 X 81 X 72 cm) 3767 57 H X 27 W X 18 D 20 71½ H X 32 W X 33 D (145 X 69 X 46 cm) (182 X 81 X 84 cm) 3767-1 57 H X 27 W X 18 D 20 71½ H X 32 W X 33 D (145 X 69 X 46 cm) (182 X 81 X 84 cm) 3770 15¼ H X 16¼ W X 11 D 6 H X 6¼ W X 8¼ D 1.9 19 H X 18½ W X 19 D (39 X 41 X 28 cm) (15 X 16 X 21 cm) (48 X 47 X 48 cm) 36

NET SHIP ELECTRICAL WT. WT. CHARACTERISTICS TEMP. RANGE ºC (ºF) LBS. LBS. MODEL VOLTS/HZ WATTS AMPS REFRIG. FREEZER (KG) (KG) 3766 120/60 480 4.0-5º to 15º 241 285 (23º to 59º) (109.5) (129.5) 3766-1 240/50 480 2.0-5º to 15º 241 285 (23º to 59º) (109.5) (129.5) 3767 120/60 516 4.3-23º to -5º 225 240 (-9º to 23º) (102.3) (109.1) 3767-1 240/50 516 2.1-23º to -5º 225 240 (-9º to 23º) (102.3) (109.1) 3770 120/60 132 1.1 0º to 7º -5º to 0º 46 52 (32º to 45º) (23º to 32º) (20.9) (23.6) NOTE: AMPS LISTED ARE AT NORMAL RUN MODE, STARTING AMPS MAY BE HIGHER. LAB-LINE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT PRIOR NOTICE. SECTION 6 INSTALLATION SHIPPING CARTON: This should be inspected upon delivery. When received, carefully examine for any shipping damage before unpacking. If damage is discovered, the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt. Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded after unpacking, if damage is found promptly report it to the carrier and request a damage inspection promptly. IMPORTANT: Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage: you must call for a damage inspection promptly. LOCATION Locate your unit in the most convenient place and near a grounded electric outlet. If units are placed on a countertop, the front should be 3" or more back from the edge to avoid accidental tipping of the unit. If possible, locate your unit out of direct sunlight and away from heat sources such as a radiator, stove or heat duct. 37

CLEARANCE: Position the unit so that there is at least 12 clearance on the top, 3 at the back, and 2 on each side. It is recommended that even more space be left at the back of the unit in case maintenance is required. ELECTRICAL Units must be connected to a grounded outlet matching the nameplate. If you are not sure about the outlet, you should contact a qualified electrician for assistance. The unit should always be connected to its own individual outlet. CAUTION: DO NOT REMOVE, UNDER ANY CIRCUMSTANCE, THE GROUNDING PRONGS FROM THE 3-PRONG POWER CORD SUPPLIED WITH ALL UNITS. CAUTION: DO NOT USE ELECTRICAL EXTENSION CORDS WHICH MAY RESULT IN VOLTAGE LOSS AND POSSIBLE HAZARDOUS OPERATION. NOTE: EXPLOSION-PROOF UNITS DO NOT COME WITH LINE CORDS,THEY REQUIRE RIGID CONDUIT TO BE RUN DIRECTLY IN ORDER TO SEAL OFF THE FITTING ON THERMOSTAT HOUSING. THIS SHOULD BE DONE BY A LICENSED ELECTRICIAN FOLLOWING ALL LOCAL ELECTRICAL CODES. IF ANY QUESTION PERTAINING TO ELECTRICAL SAFETY ARISES, PLEASE REFER TO ARTICLE 501 OF THE NATIONAL ELECTRIC CODE. 38

INSTALLATION: (Con t) HOW TO SEAL KILLARK BOX CONDUIT WITH FIBER AND SEALING COMPOUND TO HELP PROTECT AGAINST EXPLOSIONS: The purpose of the procedure that follows to build fiber rope dams on the left and right hubs of the horizontal conduit. The fiber rope damns will surround conduit wiring that is housed inside the horizontal conduit. When both the left and right fiber rope dams have been pressed into place, sealing compound is poured between the two and forms into an air-tight plug. All of this is done in order to prevent the very real threat of gas entering the Killark box and a resulting serious explosion. After the unit wires have been pulled through the horizontal conduit the following procedure is required: Turn power off at the circuit breaker before proceeding. Place a small amount of sealing compound granules (enclosed) into a clean mixing vessel. Add small amounts of water while stirring until a thick paste is formed, then carefully continue adding smaller amounts of water until a thick gravy consistency is achieved NOT WATERY. (Discard any material that becomes too stiff to use. Never attempt to restore workability by stirring in more water.) Locate silver Killark box, back/top-center of unit. CONDUIT DOMED-COVER UNSCREW & REMOVE COVER CONDUIT OPENING HORIZONTAL CONDUIT LEFT HUB RIGHT HUB Unscrew conduit domed-cover. INSTALLATION: (Con t) 39

HOW TO SEAL KILLARK BOX CONDUIT WITH FIBER AND SEALING COMPOUND TO HELP PROTECT AGAINST EXPLOSIONS: (Con t) HORIZONTAL CONDUIT, CUTAWAY: WIRING LEFT HUB RIGHT HUB Insert fiber rope material down into horizontal conduit opening. Pressing down firmly, work the material into the left hub and most importantly being sure the material COMPLETELY SURROUNDS THE WIRING, from the top to the bottom, completely blocking this end of the horizontal conduit. Insert fiber rope material down into horizontal conduit opening. Pressing down firmly, work the material into the right hub and most importantly being sure the material COMPLETELY SURROUNDS THE WIRING, from the top to the bottom, completely blocking this end of the horizontal conduit. INSTALLATION: (Con t) 40

HOW TO SEAL KILLARK BOX CONDUIT WITH FIBER AND SEALING COMPOUND TO HELP PROTECT AGAINST EXPLOSIONS: (Con t) Pour sealing compound down in between the two fiber rope dams filling the remaining space pour slowly, being careful not to trap air bubbles. (Immediately wipe off any spilled sealing compound.) Screw conduit domed-cover back onto conduit opening. NOTE: INITIAL SETUP OF SEALING COMPOUND WILL OCCUR IN APPROXIMATELY 30 MINUTE HOWEVER, THE SEALING COMPOUND REQUIRES A MINIMUM OF 8 HOURS ABOVE 32ºF TO DEVELOP SUFFICIENT STRENGTH TO WITHSTAND EXPLOSIONS. SECTION 7 OPERATION 41

DANGER: DO NOT USE IN THE PRESENCE OF FLAMMABLE OF COMBUSTIBLE MATERIALS OR EXPLOSIVE GASES. FIRE OR EXPLOSION MAY RESULT, CAUSING DEATH OR SEVERE INJURY. CHILD ENTRAPMENT WARNING DANGER: RISK OF CHILD ENTRAPMENT! Before you discard your old refrigerator or freezer: Remove door(s), Leave the shelves in place so that children may not easily climb inside. UNIT S ENVIRONMENTAL OPERATING CONDITIONS: POLLUTION DEGREE: 2 INSTALLATION CATEGORY: II ALTITUDE: 2000 Meters MSL (Mean Sea Level) HUMIDITY: 80% maximum, non-condensing ELECTRICAL SUPPLY: 120VAC or 240VAC VOLTAGE TOLERANCE: ±10% of normal rated line TEMPERATURE: 15ºC to 40ºC PRODUCT USAGE: This product is intended for use indoors only START-UP PROCEDURE: Rotate the control knob clockwise to lower the temperature and counterclockwise raise it. To check chamber temperature, place a dial thermometer on a shelf in the unit. Initially, rotate the temperature control knob to an arbitrary setting. Allow approximately 2 hours for the temperature to initially stabilize. Check the temperature and compare with the dial setting. Adjust dial further to reach the desired operating temperature. Always allow ½ to 1 hour for the chamber temperature to stabilize. Because the markings on the dial do not indicate specific temperatures, use them as reference points for any future setting of the temperature. If the room thermostat is turned below 60ºF at night, you may want to set the temperature control one step colder. It should be left at this setting for the night time period: return temperature control to original setting when the room thermostat is returned to its normal setting. RESTART PROCEDURE: If unit is unplugged or turned off, allow 3 minutes before restarting or plugging it back in. OPERATION: (Con t) MANUAL DEFROST PROCEDURE: FOR MODELS 3556-4, 3556-6, 3557-2, 3557-4 3750 & 3752 ONLY Do not use any sharp instrument, blade or scraper to remove ice and 42

frost on refrigerator surfaces because of the very real danger of puncturing the cooling coil. Do not use any electrical device to defrost the unit. When frost accumulates to ¼" or more, the operating efficiency of the unit will be affected. Use the following procedure to defrost manually: Turn the temperature control knob to the OFF setting. Disconnect the power cord from its outlet. Remove contents of unit. If practical, wrap contents in paper and then in a heavy blanket to maintain temperature of items, especially those removed from a freezer. Wear protective gloves to prevent frost bite when handling cold items. Open door and allow free circulation of ambient air. To speed the process, place pan of warm water inside the chamber. Wipe out the interior. Replace contents. Reconnect power cord to outlet and set temperature control to desired operating temperature. HOW TO SAVE ENERGY: Be sure to follow location suggestions as mentioned in the previous INSTALLATION section. Wipe moisture from glassware or other materials before placing them in a unit. Don't overcrowd the unit too many items can increase electrical energy demand in order to keep everything cool. Close the door as soon as possible in hot, humid weather. Make certain that the door is closed tightly. As soon as frost has accumulated to ¼, defrost. Keep containers covered (when possible) to reduce moisture buildup. Set operating temperature no colder than necessary for the items being refrigerated. OPERATION: (Con t) SAFETY TIPS: 43

After a unit is in operation, do not touch the cold surfaces, particularly when hands are damp skin may adhere to the extremely cold surfaces. Never disconnect your unit by pulling on the power cord: always grip the plug securely and pull straight out from the outlet. Do not use a power cord that shows cracks or abrasions. Have a qualified electrician repair or replace damaged cords immediately. REVERSING THE FRONT DOOR: MODEL 3551. Switch off at the socket outlet and pull out the mains plug. Remove all food from the appliance. Using a cross-headed screwdriver, remove the top hinge screws. Remove the top hinge (1) while holding the door. Lift the door carefully from the lower hinge (2). Remove the lower hinge (3). Reposition the upper hinge (4). Remove the lower hinge plugs (5); remove plugs with tip of small a screwdriver. Reposition the door hinge bushing and plugs on the opposite side (6). Reposition the lower hinge (7) on the opposite side and fit the hinge washer. Refit the door (8). Locate the top hinge in the door and loosely attach to the cabinet. Align the door and then tighten screws firmly on the top hinge (9) check that the door open and closes easily make sure there are no gaps which would allow air into the cabinet (adjust the top hinge if necessary). OPERATION: (Con t) REVERSING THE FRONT DOOR: MODELS 3556, 3557, 3751. Remove bolts and plugs using a screwdriver. 44