R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

Similar documents
UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Utility Battery Chargers DC Power Systems Custom Design

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

FLOAT BATTERY CHARGERS

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

LORAIN CIP 4890/48120 DC Power System

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

APS-Series 1500VDC OUTDOOR SOLAR INVERTER

APS-Series 1000VDC OUTDOOR SOLAR INVERTER

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

LORAIN CSP DC Power System

Central Emergency Lighting Inverter Systems

Light Support Power Systems CENTRAL EMERGENCY LIGHTING INVERTER SYSTEMS

Variable Frequency Drive SERIES MP800 VFD

Across-the-Line SERIES MP300 Combined Manual and Automatic

SECTION POWER SUPPLIES AND DISTRIBUTION

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Soft Start Series MP700 Solid State, Reduced Voltage

Spectron LSN (Life Safety Network) Suggested Specifications

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

B. Section Transfer Switches: Automatic transfer switch.

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AS950 REFRIGERATED SAMPLERS

Commercial and Light Industrial Fire Alarm Control Panel

Drawing Submittal Package

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Drawing Submittal Package

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

DGC-1000 DIGITAL GENSET CONTROLLER

Galaxy Pulsar Plus Digital Battery Plant Controller

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Setting the New Standard in Chiller Technology ±0.1 C ZEROPOINT CHILLER SERIES

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU

Specification for On-Line UPS Battery Monitoring and Data Management System

Batt-Safe Battery String Monitoring System

Guide Specification Model CTG Automatic Transfer Switch

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

A New Standard of Excellence

» EN50171» Lighting» Reliable

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

For Complete Fire and Gas Solutions

UltraLITE MODEL ELU. Centralized Emergency Lighting Inverters

Heating Cable. Description

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

elite TM SERIES Centralized Emergency Lighting Inverters MODEL ELE

Touchpoint Plus. A whole new control experience

EON TM. 10 kw - 55 kw THREE PHASE. Centralized Emergency Lighting Inverters MODEL EL3

AIS750 Series Alarm Annunciator

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

DemandAire. amaximize Energy Efficiency aincreased Kitchen Comfort acustomizable Systems. Demand Control Kitchen Ventilation System

CPS V Cabinet Power System

Model A1700 Series Annunciator

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

AS950 PORTABLE SAMPLERS

SECTION AUTOMATIC TRANSFER SWITCHES

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

ARR-M Series Product Manual

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

ENGINE GENERATORS AND ACCESSORIES

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

M2500 Engine Controller Installation Manual

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

FDF Foam Pump Controllers Features

Dale Power Solutions Ltd

Vocia VACIE. Reference Guide

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Model A2100 Series Annunciator

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Guide Specifications for InRow Direct Expansion

VACIE REFERENCE GUIDE REVISION 1.2.6

Power Supplies. Overview

APPLICATION DATA SHEET

Electric Coils. Blower Coils. Product Information

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

MULTIFUNCTIONAL SYSTEM

RE-PR3-E-27 3-Phase Panel Mount 27kW

CALTECH Pasadena, CA

TPSD. Installation and Operation Manual. Filtered Battery Charger Power Supply / Battery Eliminator

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Powering The Network. Network DC Power Solutions: Power Systems Converters

NERC PRC Compliance Guide

VA301C CONTROLLER WITH BACnet OPTION

Tempco s process controllers provide integrated solutions to manage your thermal loop system.

Technical Data Submittal Documents

GasGard 100 Control System

Transcription:

SCR Battery Charger

Product Specifications Description The is RIC Electronics premiere SCR battery charger/rectifier. The provides power to critical DC loads through a wide range of outputs and is engineered for maximum reliability and ease of maintenance. A key component of the charger is usability, that s why they designed a responsive human-machine interface with built in LEDs and mimic screen. Providing a bright two line vacuum florescent display and central key pad, performing routine maintenance couldn t be easier. Focusing on continual innovation has enabled their to provide mean time between failure, or MTBF to over 200,000 hours and reduce mean time to repair, or MTTR to less than 30 minutes. Offering fast lead times and customized solutions, RIC Electronics is your go-to for all industry applications. Industries Hospital Standard Features Output blocking diode Digital output voltage and current metering Battery test mode Temperature compensation (optional probe is required) Modbus TCP, RS-485 & RS-232 communications Molded case UL 489 AC and DC breakers Designed for parallel operation and loadsharing Automatic and manual equalize and float modes w/ configurable setpoints & alarming High temperature shutdown 6

Product Specifications Alarming and Control Programmable common alarm Programmable Form C relays and digital inputs High DC voltage Low DC voltage/end of battery voltage AC failure/loss Rectifier failure Ground fault (+/-) Charger overload Control card temperature (high/low) High ripple alarm Wall mount showing I/O and battery breaker Human-Machine Interface (HMI) Vacuum Fluorescent Display - bright display panel, wide viewing angles, can withstand extremely high and low temperatures Alarm Logging Password Protected Panel - only authorized users can change settings Mimic screen with LED test feature Audible Buzzer sounds alarm on common alarm Additional LEDs - customizable to any alarm HMI providing mimic screen, control and metering control 7

Available Options Mechanical Options Enclosure options: NEMA 2 NEMA 3R NEMA 4/4X NEMA 12 Floor mount/wall mount Integrated battery rack High seismic rating as per IEEE 693 Enclosure insulation Conformal coating Heater, air conditioner, fan c/w thermostat Redundant configuration Integrated load distribution breakers Breakers padlock provision/kirk-key Door mounted mushroom button E-stop NEMA 4 marine type, fully insulated charger with a heater, air conditioning and an integrated battery rack. Electrical Options 12 pulse rectifier Input/AC monitoring (voltage, current, frequency, kw, kva & harmonics) Shunt trip (AC/DC, and/or battery breaker) High short circuit capacity (KA) breakers Communication: DNP3: RS-485, RS-232, Ethernet Fiberoptic SNMP Relay card (2 form C contacts per alarm) Auxiliary alarm contact on breakers Dual input source option c/w breaker interlock Temperature probe (5, 10, 15m) NEMA 3R charger fitted with double doors and rain hoods over vents. Integrated battery rack w/ 20 yr. VRLA batteries. 8

Available Options Monitoring Solutions When charging and providing backup power for critical devices, battery health is of the utmost importance. RIC Electronics provides two solutions for your monitoring needs: integrated monitoring on a string level or stand-alone monitoring on a single cell level. Battery Sense Integrated Monitoring Integrated monitoring offers battery string voltage, current and midpoint voltage measurements and alarming functionality. The additional temperature probe provides battery string temperature measurements as well as battery temperature compensation which automatically adjusts the battery charger voltage based on ambient temperature. Single Cell Stand-alone Monitoring Stand-alone monitoring provides full single cell battery readings including: cell conductance, voltage, temperature, and strap resistance between cells. Single cell monitoring can save hours on monthly, quarterly and annual battery checks and maintenance and in turn, substantial monetary savings. Measurement Battery string voltage Battery string current Battery string midpoint voltage Battery string temperature* Single cell conductance Single cell voltage Single cell temperature Strap resistance (between cells) *Additional temperature probe may be required Battery Sense (String Level) Cell Monitoring (Single Cell Level) 9

Technical Specifications Input Input AC Voltage 1ph - 120, 208, 240, 480, 600V (other voltages optional) 3ph - 208, 480, 600V Input Breaker Short Circuit Rating 240VAC 65kAIC (standard) up to 200 kaic (optional) 480VAC 35 kaic (standard) up to 200 kaic (optional) 600VAC 18 kaic (standard) up to 100 kaic (optional) Frequency 50 / 60 Hz Power Factor Model Dependent 0.95 Input Voltage Tolerance ±10% Frequency Tolerance ± 2 Hz Short Circuit Protection Auto shutdown at 250% of rated output (Auto Recovery) Output Output DC Voltage 12, 24, 48, 120, 240VDC (others upon request) Output DC Voltage Range 12VDC: 1-15, 24VDC: 1-30V, 48VDC: 1-60V, 120VDC: 1-150V, 240VDC: 1-300 Output Breaker Short Circuit Rating 240VDC 10 kaic (standard) up to 30 kaic (optional) Output Current 5 to 1200A Efficiency Model Dependent 93% Regulation < 0.5% for input variation of 10% Ripple 1% (150mV optional) Technical Features Programmable Form C Relays 9 Programmable LEDs 4 Programmable Digital Inputs 3 Environmental Operating Temperature -25 to 40 C (up to 55 C optional) Storage Temperature -40 to 55 C Altitude Above Sea Level 1000m w/o derating Method of Cooling Convection Noise Level (1 meter) <60 dba Humidity 0 to 95%, non-condensing General Features Enclosure NEMA 1 (optional: NEMA 2, 3R, 4/4X or 12) Mounting Positions Floor mount/wall mount Enclosure Size Model Dependent Size between: 24 H x 20 W x 16 D & 70.87 H x 47.24 W x 31.50 D Certification CSA 107.1/107.2/UL1012 Communication Modbus: TCP, RS-485, RS-232 (optional: DNP3, Ethernet; Fiberoptic, SNMP) Warranty 5 years from shipment 10