In this issue. Online application change keeps businesses moving. We ve bee RE EVERYWH ARC regio visits > read in

Similar documents
Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Control of refrigerant gases during manufacture, installation, servicing

In this issue. RAC equipment use up/ refrigerant leaks down. Access Canberra Safety Alert 065 Gas Explosion

Page 2 Draft Revision to the Australian Automotive Air Conditioning Code of Practice 2014

Fire Protection Industry Board (ODS & SGG) Risk Management Plan. A risk management plan for storing and disposing of fire extinguishing agents

Retrofitting Existing Systems

Information Guide Maintenance and Refrigerant Regulations. Issue 35

Guidance for Stationary Refrigeration & Air-Conditioning

The natural solution for domestic refrigeration

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

FPA Australia submission to the review of the Ozone Protection and Synthetic Greenhouse Gas Management Act 1989 and associated legislation.

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

Legislation & Standards

FACT SHEET 6 Transport Refrigeration

Licence numbers hit record high

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

Electrical Management

Meeting the Challenges of the EU HFC Phase-Down

NOTTINGHAM CITY HOMES

4: Leakage matters: for service and maintenance contractors

ARE YOU AN AUTHORISED REFRIGERATION GAS PRACTITIONER?

FIRA Technical Services. Suzie Radcliffe-Hart Technical Manager

Risk Management for an Event example

Ozone Protection and Synthetic Greenhouse Gas Management Regulations 1995

E INSTITUTE The Official Newsletter of IPA

Periodic Electrical Testing Policy

BSI Kitemark the business case

Transitioning to Alternatives and Challenges in Japan

PERODIC NEWSLETTER NOVEMBER 2014

Fire Safety Policy (Communal Areas)

Ultra cold freezer storage. Risk management guide for research materials

Split System Air Conditioning

Fire Safety in Communal Areas Policy

PERIODIC ELECTRICAL TESTING POLICY

INFORMATION PACK COULD YOU BE THE SCREWFIX #SFTA TRADE APPRENTICE OF 2017? IN ASSOCIATION WITH

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Application Form. Qualified Accreditation

Fire Policy. Fire Safety Order (2005) Dangerous Substances and Explosive Atmospheres Regulations (2002)

EXTINGUISHER MAINTENANCE METHOD STATEMENT.

CCTV Policy. Core values in daily life at St John Rigby College are expressed as:

Update - Home Improvement

Split System AIR CONDITIONING RANGE. Australians love a Kelvinator

Guided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)

CONTRACTOR WHS HAZARD STANDARD LASER SAFETY EXTERNAL USE ONLY

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Mitsubishi Electric Guide to Chiller Technologies. Information Guide 58

Fire Protection Accreditation Scheme (FPAS)

Type 5 Certifications:

Fire safety and high rise student accommodation

Victorian Solar Hot Water Rebate Guidelines for Applicants and Suppliers (Updated 4 September 2009)

Split System AIR CONDITIONING RANGE. Australians love a Kelvinator

Guide to Membership Assessments

Workplace Health and Safety Hotel Induction Handbook

Refrigerant Recovery Machine. Model No Operating Manual

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Under Section 608 of the CAA, EPA has established regulations (40 CFR Part 82, Subpart F) that:

Making equipment decisions

PENRHYN QUARRY BETHESDA GWYNEDD. Proposed Inert Recycling Facility DESIGN AND ACCESS STATEMENT

Actions to Control Emission of HFCs in Japan

INFORMATION PACK UP FOR THE CHALLENGE? To apply please visit Applications open from 5th February until 4th March 2018

Fire risk management plan. MH/05/Revised/06/17

BETTER DEVELOPMENT. The Greens will take on shoddy developers

Value Paper Authors: Stuart Nunns CEng, BSc, FIET, FInstMC. Compliance to IEC means more than just Pfd!

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Health & Safety Policy

Electrical Safety Policy

LANDSCAPE INSTITUTE CORPORATE STRATEGY ISSUED 3RD APRIL Landscape Institute 107 Grays Inn Road London WC1X 8TZ United Kingdom

BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS

ILEX Individual Medals Nomination Form 2011

DUH Background Paper. Deficiencies in treatment of CFC-containing waste refrigeration equipment in Germany

Managing Ex Asset Integrity

MOMENTS Alexander Interiors

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

EC Regulation No 842/2006 on certain fluorinated greenhouse gases

Procedure: Emergency Preparedness Response & Operational Control

CLOSED CIRCUIT TELEVISION POLICY

INFORMATION PACK UP FOR THE CHALLENGE? To apply please visit Applications open from 4 th March until 31 st March 2019

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

THE ULTIMATE HEATING + COOLING GUIDE PCRAU0318

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Statutory Compliance Checklist

Fire Safety Policy 2018/19

5.5 CD/14 (Warning & Advice Notice)

HIGH VOLTAGE ELECTRICAL SUPPLY CONNECTIONS Overview of High Voltage Customer Obligations

International New Technology and Refrigerant Symposium

St Edward s Oxford FIRE SAFETY POLICY

Council is committed to its groups working together, and to working closely with other relevant agencies, including the Queensland Police Service.

elaundercare; On Premise Laundry Procedures

Facilities and Estates. Hot Works: Standard Operating Procedure. Document Control Summary

United Nations Environment Programme Headquarters Bangkok, Thailand

Safety Systems Review Retail Guidance and specification Version

CLYST ST. MARY VILLAGE HALL

Policies and Measures for HCFCs in Japan

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

Split System AIR CONDITIONING RANGE. Australians love a Kelvinator

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

Loss Prevention Standard

Draft Eastern District Plan

Provincial Heritage Places Recognition Program

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

Transcription:

Newsletter for the Refrigeration and Air Conditioning Industry August 2018 In this issue Online application change keeps businesses moving We ve been EVERYWHERE Face-to-face education is the key to compliance FREE promo materials & servicing stickers RAC apprenticeships taking off! Property managers told to look for the tick Be well-equipped: commercial freezer room TECH TIP refrigerant identifiers are not all the same 49 Online application change keeps businesses moving Adding a risk management plan (RMP) template to RTA applications has simplified the online process. Under the Ozone Protection and Synthetic Greenhouse Gas Management Regulations 1995, a condition of holding an RTA is implementing an effective RMP. A RMP should identify potential risks which could result in the emission of refrigerant to the atmosphere and identify processes and practices that minimise the possibility of those risks occurring. In the past a RMP needed to be submitted separately to an online application. The new pre-populated template provides businesses with a generalised RMP for refrigerants, which they can tailor to their specific needs. Hopefully these changes make life a little easier for businesses, said ARC CEO Glenn Evans. Businesses now have the opportunity for an uninterrupted application process, without delays and potential restrictions on refrigerant purchases. Basically, they can get on with what they do best, he said. To view the RMP template visit the ARC website www.arctick.org/rmp Do not charge R32 in systems designed for R410a Aussie innovation rapid refrigerant recovery ARC Director gets nod for industry Hall of Fame n We ve bee RE E EVERYWH nal ARC regio visits > read in side Australian Refrigeration Council www.arctick.org ARC Hotline: 1300 88 44 83

We ve been EVERYWHERE With two ARC field officers based in each mainland State, we cover a lot of ground. However, it s not uncommon for businesses and technicians in remote areas to think we might not make it to see them. While we can t be everywhere at once, the ARC makes sure field officers plan permit condition and education visits to reach remote places on a regular basis. Just recently, WA-based field officer Robert Clark did a 1,500 km round trip from Perth to Esperance, where he met with many businesses, providing guidance and advice on compliance, as well as gathering evidence into non-licensed activity. In the past 3 months, ARC field officers have conducted permit condition checks and education visits to areas including: NSW South Coast, Eden to Batemans Bay the ACT WA, Esperance and surrounding areas QLD, Gladstone and surrounding areas. The trips focused on: making sure automotive licence holders are working to the codes of practice ensuring refrigeration and air conditioning training providers had the understanding and appropriate equipment to deliver quality training for the sector making sure restricted licence holders are working within their licence entitlements, and visiting local councils and checking the processes for refrigerant recovery from end-of-life air conditioners and refrigerators. We found the businesses and people we met were eager to do the right thing and were supportive of the ARC and the scheme. It was great to see many businesses had their refrigerant records in place and had a good grasp of what to do. In particular, it was great to see the new RTA record keeping templates in action. Record keeping templates can be found on our website at www.arctick.org/ business-authorisation/business-reporting-templates-and-guides/ In the coming months we are planning to visit parts of northern Victoria and central New South Wales, so keep an eye out for news about our trips and contact our customer service team on 1300 884 483 if you have any questions about your authorisation or licence. Face-to-face education is the key to compliance Statistics highlight the value of targeted face-toface education when it comes to refrigeration and air conditioning businesses achieving compliance. About 30,000 permit condition checks have been performed over the past few years. Face-to-face conversations are essential for a better understanding of the regulations and better compliance outcomes, said ARC CEO Glenn Evans. A visit from a qualified and experienced ARC field officer goes a long way to helping RAC businesses better understand their responsibilities, particularly when they have specific questions about reporting, equipment or gas cylinder maintenance. They may even help businesses find efficiencies in their reporting or refrigerant management. ARC field officers provide education materials and fact sheets for businesses to use and share with their staff. They are available free of charge on the ARC website www.arctick.org and categorised for technicians, businesses and apprentices.

FREE promo materials & servicing stickers The ARC provides free resources for you to promote your licence and authorisation to customers, and ensure your servicing and work is labelled correctly. Whether your business already promotes its competitive prices, great service or years of experience, communicating your licence/authorisation provides that important tick of credibility. It gives customers peace of mind they have chosen a qualified person to do the job and meet environmental regulation requirements. The following is a check-list of free promotional items and servicing stickers developed for appropriate licence and authorisation holders. Please note: For licence and authorisation holders, eligibility for some items is restricted by the entitlements of the licence held and by the licence holder(s) nominated under the authorisation. Stickers General Service Tags (RAC only) General Air Conditioning Service stickers (RAC and Auto) Degassed stickers Licensed Sticker for work vehicles Under Bonnet service stickers (Auto) Refrigerant type used: Refrigerant oil type used: Ultraviolet dye added: Service person name: Service person ARC licence no: Business name: Date of service: Posters Licensed Air Conditioning Maintenance (A3) (RAC and Auto) Licensed Air Conditioning Service outdoor signage for workshop/shop front (corflute, 45cm X 62cm) (RAC and Auto) Call your ARC-licensed technician for an annual check-up Hand-outs Benefits of using Licensed Technicians for customers (RAC and Auto) Air Conditioning Information Guides for customers (Home and Auto air conditioning only Auto shown) Encouraging regular maintenance for customers cool Air conditioning is Your air conditioner and fridge should be serviced regularly by an ARC-licensed technician, who will check for blockages and cleanliness. They can also do more extensive check-ups and maintenance work, such as inspecting, cleaning and performance testing, as well as helping you to decide whether it s time to replace your cooling system. AIR CONDITIONING GUIDE Why use ARC-licensed technicians? ARC-licenced technicians have shown themselves to be qualified to do the job. They have met the licensing / authorisation requirements under the Ozone Protection and Synthetic Greenhouse Gas Management Regulations 1995 and must adhere to an Industry Code of Practice. Non-licensed technicians have not demonstrated their willingness to adhere to their legal obligations and this may reflect in their services. Using un-licensed technicians may lead to: Sub-par service / installation which may mean additional services are required Risk of product warranty becoming null and void Risk of refrigerant leaking into the atmosphere - bad for the environment and bad for the performance of the system www.arctick.org www.lookforthetick.com.au REGULAR SERVICING REGULAR SAVINGS lookforthetick.com.au Date: RHL: DEGASSED Your record of air conditioning service Your air conditioning was serviced/repaired on: / / Service person ARC licence no: Next service due: / / cool Air conditioning is AIR CONDITIONING GUIDE Qualified and Licensed lookforthetick.com.au Contact the ARC via email at enquire@arctick.org to place an order

Do not charge R32 in systems designed for R410a The following statement was issued by the Federation of Environmental Trade Associations (FETA UK) on 13 March 2018. FETA has recently been advised that there have been some instances of R410a (classified as A1; non-flammable) being completely removed from an air conditioning system, and the system being recharged with R32 (classified as A2L; low flammability). Given the differences in properties of these two refrigerants, a number of issues need to be taken into account: Refrigerant manufacturers have clearly stated that A2L refrigerants are NOT SUITABLE for retrofit. A system that was originally designed for R410a will not have taken into account the safety factors required when using an A2L refrigerant and could create a significant safety hazard. Systems designed for use with R32 have different pressure switch regimes, altered inverter profiles, and specially designed heat exchangers. Charging an existing system with R32 would leave the system non-compliant with the refrigerant safety standard EN 378, leading to the possibility of forming a flammable atmosphere in a leakage situation. Such a refrigerant change would be strictly against the system manufacturer s instructions and would render any relevant warranty invalid. It would also mean that the system would not be compliant with CE marking or the Pressure Equipment Directive and could also have insurance implications. R32 has a higher compressor discharge temperature than R410a, and will increase wear on the compressor, reducing its life significantly. Should any problem arise from a system change such as this, any liability would rest ENTIRELY with the person who carried out the change. In summary, it is not good practice to charge a system with a refrigerant that the system was not originally designed to use without appropriate assessment of the differences in characteristics of the replacement gas. Aussie innovation rapid refrigerant recovery In May, Melbourne-based refrigerant wholesaler A-Gas launched an innovative refrigerant recovery service that can empty refrigerant out of a system faster than conventional equipment. The A-Gas Rapid Recovery service operates in Victoria and New South Wales and allows contractors to sub-contract refrigerant recovery to A-Gas. A-Gas will send a RAC licensed technician to a site in a fully equipped vehicle that has custom made, petrol powered refrigerant pumps mounted on it. Each pump weighs 275kg and can handle standard refrigerants and low-pressure liquids such as R11 and R123. The pumps cannot recover natural refrigerants. A recent trial with a major supermarket involved pumping 320kg of R404a out of one of their LT racks leaving the system at atmospheric pressure. This recovery service was performed in 30 minutes and 33 seconds. Refrigerant gas is recovered from systems into cylinders that can be left on site whilst maintenance is completed. The contractor will then pump it back in and call A-Gas to return to pick up the cylinders upon completion or request them to take the product away for recycling or destruction. The same process applies if the refrigerant is being removed from a decommissioned system. A-Gas Rapid Recovery can either take the gas away for recycling or arrange for it to be destroyed. All jobs are recorded and the customer can access a full report of refrigerant records that can be used during a RTA permit condition check. Do you know of other environmentally conscious innovations in refrigeration and air conditioning? Let us know at enquire@arctick.org

ARC Director gets nod for industry Hall of Fame In May, Australian Refrigeration Council Director Mark Padwick was inducted into the Air Conditioning, Refrigeration and Building Services (ARBS) Hall of Fame. As well as being an ARC Director, Mark is President of the Air Conditioning & Refrigeration Equipment Manufacturers Association and Managing Director of Sanden. Mark was also Chairman of the ARC for six years. Mark s influence on the refrigeration and air conditioning sector over many years was recognised by ARBS member industry associations, who nominate inductees each year. ARBS Hall of Fame inductees have significantly contributed to the development of the HVAC&R and building services industry. They are recognised for their outstanding service, contribution and commitment above and beyond the call of duty. The individuals have worked tirelessly, and in most cases voluntarily to further the industry and its endeavours with demonstrable achievements that have greatly benefited the industry. In particular, ARBS recognised Mark s work influencing industry policy and representing the interests of technicians and businesses in the sector. Mark Padwick with his ARBS Hall of Fame trophy From everyone at the ARC we congratulate Mark on this prestigious achievement. RAC apprenticeships taking off! Refrigeration and air conditioning (RAC) training providers have announced that RAC apprenticeships have increased in the past 12 months in some cases by up to 100 per cent. At a May 2018 meeting of the National Refrigeration and Air Conditioning Training Alliance (RACTA), two trainers one from Far North Queensland and one from New South Wales each reported a 100 per cent increase in the number of students enrolled in RAC courses. The RACTA group gives registered training organisations an opportunity to meet and discuss important information and direction on national training packages and future improvements to the training system and delivery. ARC s Technical and Training Manager, Noel Munkman is a member of this group. Significantly, the examples from Far North QLD and NSW were not isolated. All other members of the RACTA group had similar stories to tell, with an average increase of 50 per cent across the group. This is a fantastic trend for the future of our industry. There have been a number of quality initiatives delivered by various industry groups over the past two years focused on promoting the RAC sector. In early 2017, ARC produced an industry careers video which was sent to secondary schools Australia-wide, along with a package of information promoting the industry as vital to modern life, and a pathway to career opportunities. Australian Refrigeration Council www.arctick.org ARC Hotline: 1300 88 44 83

Property managers told to look for the tick Recently, the ARC wrote to property managers Australiawide about the benefits and legal requirements of using appropriately licensed tradespeople to repair and maintain cooling and heating systems under their care. Property managers are key decision makers when it comes to choosing a business and technician to repair and maintain air conditioners in properties under their management. It is vital they understand only fully licenced refrigeration and air conditioning (RAC) technicians can perform these services. Using RAC licensed tradespeople: reduces the risk of sub-standard repairs and maintenance, and related costs helps extend the running life of cooling systems minimises system down-times to maximise tenants comfort reduces emissions of fluorocarbon refrigerant into the atmosphere that can damage the ozone layer and contribute to global warming, and meets Government requirements that only technicians with a Full RAC licence can service RAC systems. Be well-equipped: commercial freezer room Working on commercial freezer rooms of varying sizes and locations means there are some things a technician may be required to comply with. Personal Protective Equipment (PPE) Correct industrial clothing and footwear (compliance with AS4602 and AS2210). This may include eye protection, ear protection, gloves and a hard hat. This may also include thermal clothing when entering a freezer room with temperatures of minus 20C or lower. Site induction or notification Are you working alone or do you have an apprentice or another tradesman? (This may include plant room access too). Working at heights, hot works, confined spaces Are on site permits required? Do you have all the correct safety equipment and understand its correct function and application? Awareness of alarms when working in these areas Location and requirement for power isolation Understanding the difference between control circuit isolation and mains isolation. Restrictions may apply to mains isolation and permission or other persons may be required. Understanding of system pipework layout and all its functions Correct isolation of system components when accessing system for service works. Compliance with refrigerant handling code of practice 2007 part 2 Identification of refrigerant type and quantity required for correct operation Understanding correct system performance and operation Works completion documentation Return of site security. Notification of site departure and completion of any site documents. Please note: This is not a prescribed list or an exhaustive list. There may be a significant number of other items that you are required to complete, either by your employer, Legislation (State or Commonwealth) or the site customer/occupant. TECH TIP Refrigerant identifiers are not all the same On a recent visit with a refrigerant wholesaler, one of our field officers told the following story highlighting the potential for misdiagnosis from refrigerant identifiers: A wholesaler asked me to test a cylinder of refrigerant after they received a report from a customer that their refrigerant identifier indicated the R404a cylinder contained air. I have both a new and old model electronic refrigerant identifier, so I took both. To ensure that both identifiers were operational, I did a test for R134a from a separate cylinder. Both identifiers tested 100% pure, indicating they were operational. I began by testing the customer s refrigerant with the newer model identifier. This tested fine for R404a. However, the older model indicated air was present on both occasions I tested the cylinder. I then checked the operating manual for the older model which stated it was able to identify R12, R134a, R22, HC and R410a. No mention of R404a. It turned out the customer had an older model identifier, and that the cylinder contained 100 per cent R404a. Technicians should make sure their refrigerant identifiers are fit for purpose before testing refrigerant.