WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

Similar documents
Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 310/610 ECO PRO RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

WELCOME TO REMEHA, THE EXPERT CHOICE REMEHA QUINTA RANGE FEATURES AND BENEFITS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Remeha Quinta 30. Technical information. High-efficiency. condensing boiler for. wall mounted. installation. Output: kw

Remeha Quinta 45 and 65

Sirius FS. Working towards a cleaner future

Sirius WH. Working towards a cleaner future

Remeha Quinta 85. Technical information. Remeha Quinta 85. High-efficiency. condensing boiler for wall. mounted installation.

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

Remeha Quinta 115. Technical information. Remeha Quinta 115. High-efficiency. condensing boiler for wall. mounted installation.

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

ENERGY TOP. Condensing boiler solutions

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Hamworthy Fleet Vertical Floor Standing. Condensing Boilers Natural Gas Outputs 80kW to 1050kW 5 YEAR HEAT EXCHANGER WARRANTY

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

Technical information. Remeha P 500. Pressurized boiler. Heat output: kw

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Hamworthy Fleet Horizontal Floor Standing. Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY

Seradens Super Seradens Super Plus

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Residential Heating Boilers

1 VICTRIX ZEUS Superior kw I features

RIELLO 40 GS/M SERIES

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

S-AF Floor Standing Condensing Boiler kW

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

Remeha Gas 610 ECO. Technical information. Remeha Gas 610 ECO. High efficiency condensing. boiler with low NO X emission. Heat outputs: kw

Cast Iron Boilers. G Series ( kW)

Compact HRE Boiler Range. The smart choice for heating and hot water

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Gas 220 Ace Cascade Assembly Manual

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

range W, Plus Condensing boilers kW Commercial & Industrial Boilers

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

R-SERIES kW YEAR ROUND MAXIMUM CONDENSING BOILER. burning diesel oil, kerosene, natural gas or liquid petroleum gas

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

EVOMAX CONDENSING BOILER

WOLF GAS CONDENSING BOILERS COMFORTLINE

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

Power X High Power Condensing Wall-Hung Boilers

remeha Gas 3c ECO Technical information Fully condensing atmospheric gas boiler kw

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

EVOMAX CONDENSING BOILER

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Clyde CK40. Cast Iron Boiler. Engineering Data Sheet 663/8 May Natural gas Class D oil Dual Fuel. 350 kw to 500 kw

Hamworthy. Wessex Modumax. High Efficiency, Fully Modulating Boilers Condensing & Non Condensing, Pre-mix, Gas Fired. Outputs 100kW to 750kW

TopGas Wall Hung Condensing Gas Boiler

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Condensing Boilers. Floor Mounted - Evomod, Imax Xtra & Imax Plus III. Commercial Heating Solutions.

Copper-Fin GAS-FIRED BOILERS

Ultramax PB. Floor standing premix gas fired condensing boilers with outputs at 65, 85, 100 & 120kW BOILERS

Copper-Fin GAS-FIRED WATER HEATERS

Power X High Power Condensing Wall-Hung Boilers

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

INDEPENDENT COMBINATION & SYSTEM BOILERS.

VICTRIX Superior kw Export VICTRIX Superior kw X Export

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data

C Tahiti. condensing

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

EVOMAX CONDENSING. PRODUCT & FLUE GUIDE IDEALCOMMERCIALBOILERS.COM

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Exclusive Green E Condensing Wall-Hung Boilers

CONDENSING HIGH EFFICIENCY BOILERS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

CITY OPEN - CITY BOX from 25 to 35 kw

95% Hamworthy Fully Modulating, Low NOx, Stainless Steel, Condensing Modular Boilers. Wessex ModuMax mk3. New. Restyled with latest Siemens controls

CPM WALL HUNG GAS FIRED CONDENSING BOILERS. Installation, Commissioning and Maintenance instructions

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

PRODUCT CATALOGUE

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

Transcription:

GAS 110 ECO

WHAT S INSIDE 03 WELCOME TO REMEHA 03 INTRODUCING THE REMEHA GAS 110 ECO RANGE 04 BOILER CONSTRUCTION 07 OPERATING PRINCIPLE 08 TECHNICAL INFORMATION 10 ENGINEERING SPECIFICATION 11 DIMENSIONS AND CONNECTIONS 12 MAINTENANCE AND SERVICE CLEARANCES 13 TYPICAL INSTALLATIONS 14 ELECTRICAL INSTALLATION 15 ELECTRICAL CONNECTIONS 16 FLUE OPTIONS 23 MODULAR/CASCADE OPTIONS 25 SMART TECHNOLOGY AND COMPONENTS 27 TECHNICAL SUPPORT 27 DECLARATION OF COMPLIANCE

GAS 110 ECO RANGE 03 WELCOME TO REMEHA, THE EXPERT CHOICE WE LEAD THE WAY IN INNOVATION, RELIABILITY AND EFFICIENCY FOR ADVANCED COMMERCIAL HEATING SOLUTIONS. We re completely focused on commercial heating solutions and are at the forefront of condensing gas boiler technology we don t manufacture boilers for anyone else. We heavily invest in research and development which enables our specialist team to design high-performance products at every level. From using the latest materials and manufacturing techniques, to meticulously designing and engineering each boiler, we ensure they re efficient to specify, install, run and maintain. INTRODUCING THE REMEHA GAS 110 ECO RANGE All our boilers share the same simple design, so they re expandable, adaptable and future-proofed. We ve tried to think of everything, so from specification to blueprint sign-off, through to supply and installation, our customer service and product support is our number one priority. FEATURES AND BENEFITS The Gas 110 Eco range features advanced floor-standing, modular gas-fired condensing boilers, available in 65 and 115kW models. These boilers have been specifically developed to fit directly into the same floor area as a traditional boiler of equal output, promoting higher energy-efficiency and lower carbon emissions. They're designed for sealed and open-vented heating systems, with a maximum operating temperature of 90 C. High efficiency boiler up to 96.3% GCV Small dimensions and lightweight design Ultra-low, Class 5 NO x emission levels of 35mg/kWh at 0% 0 2 dry or less Premix down-firing gas burner and one-piece cast aluminium heat exchanger Digital display, removable front panel, data file for storing information and remote signalling options Remeha s built-in advanced boiler control: modulating 19-100% (5:1) Open Therm (OT) control 0-10V or volt-free control integration Cascade/modular packages for up to six boilers Quiet operation <48 db(a) For use with natural gas and LPG (115 requires a conversion kit) Higher than average energy-savings Easy to install in smaller spaces particularly suitable for retrofit applications Low pollutant emissions that meet environmental regulations including BREEAM and Clean Air Act Clean, trouble-free operation Improved ease of maintenance and operation Built-in flexibility for easy installation and reliable heat delivery Effective space-saving solution for greater design flexibility Improved comfort Flexible solution to energy-saving heating

GAS 110 ECO 65 BOILER CONSTRUCTION 9 8 7 6 10 11 5 4 3 12 2 1 13 C001485 KEY 1 Fan air inlet 6 Fan 11 Flame inspection window 2 Return sensor 7 Control panel 12 Heat exchanger inspection cover 3 Heat exchanger 8 Burner 13 Siphon 4 Venturi 9 Flow temperature sensor 5 Gas valve 10 Ignition electrode and ionisation electrode

BOILER CONSTRUCTION 05 GAS 110 ECO 115 BOILER CONSTRUCTION 9 8 7 6 10 11 12 5 4 3 2 1 13 C001485 KEY 1 Fan air inlet 6 Fan 11 Flame inspection window 2 Return sensor 7 Control panel 12 Heat exchanger inspection cover 3 Heat exchanger 8 Burner 13 Siphon 4 Venturi 9 Flow temperature sensor 5 Gas valve 10 Ignition electrode and ionisation electrode

OPERATING PRINCIPLE 07 GAS 110 ECO OPERATING PRINCIPLE The products of combustion, in the form of hot flue gases, are forced through the heat exchanger, transferring their heat to the system water. The flue gas temperature is reduced to approximately 5 C above the temperature of the system return water then discharged vertically via the condensate collector, through the flue connection to atmosphere. The low flue gas exit temperature means there will be a vapour cloud formed at the flue gas terminal this is water vapour formed during the combustion process. If the controls allow the flow, and therefore return temperature, to fall below dew point (55 C), this water vapour will begin to condense in the boiler, transferring its latent heat into the system water and increasing the output of the boiler, without increasing gas consumption. Condensation formed within the boiler and flue system is discharged from the boiler to an external drain via the drain pan/siphon supplied. Combustion air is drawn into the closed air box by a variable speed fan, through the air inlet connection from the plant room (open flued) or from outside via the concentric flue system (room-sealed). On the inlet side of the fan is a specially designed Venturi which is connected to the outlet side of the gas valve. Depending on the demand (under the dictates of flow/return sensor and other external/internal control inputs) the electronic control unit directly monitors the volume of gas and air being delivered to the premix burner. This mixture is initially ignited by the combined ignition/ionisation probe which then monitors the state of the flame. If the flame doesn t ignite or is unstable, within the pre-set safety time cycle, the controls will shut the boiler down (after five attempts) requiring manual intervention to reset the boiler. The digital display will also indicate a flashing fault code confirming the reason for the failure.

GAS 110 ECO TECHNICAL INFORMATION GAS 110 ECO 65 GAS 110 ECO 115 PERFORMANCE Nominal heat output central heating operation @ 80/60 C kw (min-max) 12-61 16.6-107 Nominal heat output central heating operation @ 50/30 C kw (min-max) 13.2-65 18.4-114 Nominal input (Hi) (min-max) 12.2-62 17.2-110.2 EFFICIENCY SBEM seasonal efficiency GCV 96.3% 94.79% Efficiency full load 100% NCV 98.3% 97.1% Efficiency part load 30% NCV 108.9% 107.1% ECO design useful efficiency @ 80/60 C (100% full load) GCV 88.6% 87.5% ECO design useful efficiency @ 50/30 C (30% part load) GCV 98.1% 96.5% Energy labelling seasonal space efficiency GCV 96% N/a ErP efficiency rating A N/a Annual energy consumption Gj 189 N/a GAS Standard fuel Natural gas Natural gas Optional fuel adjustment see installation and service manual LPG (propane) LPG (propane) conversion kit required Max gas consumption NG m 3 /h 6.56 11.66 Max gas consumption LPG kg/h 4.82 8.56 Min-max gas inlet pressure NG mbar 17-40 17-40 Min-max gas pressure LPG mbar 25-60 25-60 Gas connection size BSP inches ¾ Male thread ¾ Male thread FLUE (CONCENTRIC CONNECTION SUPPLIED AS STANDARD) Flue diameter mm I/D 100 Air inlet diameter mm I/D 150 Min-max flue gas flow rate kg/h 20.5-104 28.9-186 Average flue gas temperature (75/60 C) 65 67.9 Residual fan duty PA 100 250

TECHNICAL INFORMATION 09 GAS 110 ECO TECHNICAL INFORMATION GAS 110 ECO 65 GAS 110 ECO 115 HYDRAULICS Water content litres 6.5 7.5 Hydraulic resistance @ 20 C T mbar 175 230 Resistance @ 11 C T mbar 580 830 Nominal flow rate @ 20 C T l/s 0.73 1.28 Nominal flow rate @11 C T l/s 1.32 2.32 Minimum flow rate l/hr 240 350 Condensate connection Connection size BSP 25mm OD 1¼" Male thread Standard operating temperature C 20-90* Max operating temperature C 90* Max water temperature C 110* Max water operating pressure bar 4 Min water operating pressure bar 0.8 Min water operating pressure bar open vented* (OV) 0.3 0.5 GENERAL Dry weight kg 116 133 Dimension (WxHxD) (includes flow/return and gas pipework) 600 x 1100 x 770 600 x 1322 x 770 NO x (dry, 0% 0) mg/kwh EN483/15420 32 35 Noise levels db(a) at 1 metre 48 <48 ECO Design Sound Power Levels LWA indoors db 49 N/a Standby heat loss kwh/24hr 0.125 0.131 ELECTRICAL Nominal power supply 230v x 1ph x 50hz Power consumption w 88 213 Modulating input v DC 0-10 Fuse rating amps 6.3 Controls voltage 24 (max 4va) Insulation class IP 21 *Open vented option maximum operating temperature 75 C.

SUGGESTED ENGINEERING SPECIFICATION GAS 110 ECO CONSTRUCTION The boiler will be a floor standing type condensing boiler. The single piece, cast aluminium heat exchanger and other major components are contained within a sealed air box. The boiler casing is complete with a removable front section for maintenance purposes. Electrical and electronic controls are contained within the instrument panel mounted in the hinged top panel and also the electrical housing mounted on the inside of the boiler panel. HYDRAULIC, GAS AND FLUE CONNECTIONS The combined flue gas outlet and combustion air inlet shall be mounted at the top of the boiler, with the flow, return, gas and condensate connections located at the rear. The boiler is suitable for room-sealed or open flue applications. The boiler is designed for central heating and indirect hot water production up to four bar working pressure. The boiler is suitable for use on sealed systems and open vented installations. OPERATION The boiler is complete with a modulating control system that limits the maximum difference in temperature between the heating flow and return, and the maximum speed at which the flow temperature increases. The boiler is complete with a pre-mix burner (NG or LPG) with the gas/air ratio control system controlled internally. An intelligent, advanced boiler control continuously monitors the boiler conditions, varying the heat output to suit the system load. The control is able to react to external negative influences in the rest of the system (flow rates and air/gas supply problems) maintaining boiler output for as long as possible without resorting to a lock out condition. Should a negative effect happen in the system the boiler reduces its output and/or shuts down (shut-off mode), awaiting the negative conditions to return to normal before restarting. The control cannot override the standard flame safety controls. Standard frost protection shall activate below 7 C with stage one activating the system/shunt pump. Stage two shall activate below 3 C with boiler switching on to 10 C flow. CONTROLS The boiler includes a controls package that allows the actual and set values to be read and adjusted on the built-in digital display, which also provides normal operating and fault code indication. The controls come as standard with the following inputs/outputs: 0-10V input (flow temperature or load control) DHW temperature input (optional) High-limit lock out Safety/shutdown/release input Low water protection Outside sensor (optional) External shunt pump control Service report output External system pump control (optional) Fault alarm output DHW 3-port valve control Open therm interface Flue gas damper (optional) FEATURES Ultra-low NO X <37 mg/kwh Fully modulating Quiet operation <48 db(a) Data file for storing fault/run info ErP compliant PC connection Premix burner The boiler meets the requirements of the EC regulations and directives 90/396/EEC Gas Appliances Directive 92/42/ EEC Efficiency Directive 2006/95/EC Low Voltage Directive 89/336/EEC EMC directive ErP compliant ECA listed CE Certification Remeha Gas 110 ECO 115/65 CE-0063BS3826.

ENGINEERING SPECIFICATION AND DIMENSIONS AND CONNECTIONS 11 The Gas 110 Eco 65 has a compact design of w600 x h1100 x d770 including flow/return and gas pipework and the Gas 110 Eco 115 is w600 x h1322 x d770. GAS 110 ECO DIMENSIONS AND CONNECTIONS 600 240 110 770 663 4 ØF 245 1 170 D A 5 208 1 21 C001272 B 2 3 C E 460 420 198 158 118 173 1210 600 A C001486 DIMENSIONS 1 Heating outlet 1¼" M A Gas 110 Eco 65: 1100mm Gas 110 Eco 115: 1322mm ØF Forced flue connection Gas 110 Eco 65: Ø100/150mm Gas 110 Eco 115: Ø100/150mm 2 Heating return 1¼" M B Gas 110 Eco 65: 410mm Gas 110 Eco 115: 632mm (1) Basic dimension: 21mm Adjustment: 21 to 40mm 3 Condensates discharge: (Ø25mm external) C Gas 110 Eco 65: 124mm Gas 110 Eco 115: 346mm 4 Automatic air vent D Gas 110 Eco 65: 968mm Gas 110 Eco 115: 1190mm 5 Gas inlet ¾" M E Gas 110 Eco 65: 152mm Gas 110 Eco 115: 374mm

MAINTENANCE AND SERVICE CLEARANCES Clear space should be left around the boiler: 700mm in front of the boiler 400mm above the boiler 100mm each side of the boiler. (Facilitates removal of the casing.) VIEW FROM ABOVE 700 663 300* 600 600 100 600 100 600 250 VIEW FROM THE SIDE 400 A 300* 600 663 700 Note: *300mm refers to singular boiler installations, 600mm refers to modular boiler applications.

MAINTENANCE AND SERVICE CLEARANCES AND TYPICAL INSTALLATIONS 13 Note: These layouts do not constitute a design. Calculations must be carried out to ensure pipework and pumps are sized to match boiler nominal flows against system design flow requirements. All connections are to the back of the boiler. TYPICAL INSTALLATIONS SINGLE BOILER Flow Return Gas Condensate SINGLE BOILER, DIRECT HOT WATER PRIORITY WITH LOW LOSS HEADER Flow Return Gas Condensate MODULAR/CASCADE BOILER CONFIGURATION Condensate Flow Gas Return

ELECTRICAL INSTALLATION GENERAL The Gas 110 Eco is supplied as standard with electronic control and flame ionisation safety controls, with a specially designed microprocessor at the heart of the control system. SPECIFICATIONS ELECTRICAL SUPPLY The Gas 110 Eco must have a permanent 230V 50Hz single phase supply rated at 6.3 amps. The control unit is not phase/ neutral sensitive. CONTROL BOX Manufacture Model Supply voltage Gasmodul MCBA 1461 D 230V/50 Hz BOILER TEMPERATURE CONTROL The Gas 110 Eco has electronic temperature control with flow and return temperature sensors. The flow temperature can be adjusted between 20 and 90 C. HIGH-LIMIT TEMPERATURE PROTECTION The high-limit temperature protection device switches off and locks out the boiler when the flow temperature exceeds the high-limit set point (adjustable). When the fault is corrected, the boiler can be restarted by using the reset key on the control panel. LOW WATER PROTECTION (FLOW AND CONTENT) The Gas 110 Eco is supplied with low water protection via temperature measurement. By modulating back at the moment the water flow threatens to fall too low, the boiler is kept operating for as long as possible. In the event of low flow (F/R T > 45 C) the boiler will shut off and not lockout. If the boiler is fired dry it will go to lockout (code 18). Electrical rating Pre-purge time Post-purge time Safety time Anti-hunting time Pump run on (HTG) Pump run on (DHW) 10VA 0.3 seconds 10 seconds 3 seconds 150 seconds 1-15 minutes 5 minutes FUSE SPECIFICATION The boiler is protected by fuses: On the 203V power supply located in the control panel 6.3 amps (fast acting) On the control box located on the bottom right hand side of the boiler: Control circuit 230V 2 amps (fast acting) Control circuit 24V DC 4 amps (slow acting)

ELECTRICAL INSTALLATION AND ELECTRICAL CONNECTIONS 15 The Gas 110 Eco 65/115 must have a fixed 230v 50Hz single phase mains supply. It must be powered by a circuit containing a double pole switch with an opening distance of 3mm. ELECTRICAL CONNECTIONS A BUS GND + T T T L L1 N 1 2 3 4 5 6 7 8 9 10 111213 14 15 1617181920 2122 2324 252627 N L N L Safety interlock link Optional flue damper link B 300014906-001-C Note: The power and control terminal wiring strip can be accessed by removing the top casing panel and instrument cover plate. All external connections are made on the 27 way terminal strip (A). KEY A. STANDARD TERMINAL CONNECTIONS 1-2 0-10v or modulating controller 10 Safety interlock (10-14) 19-20 Boiler pump or system pump (max 1 amp) 3-4 Enable on/off or first stage firing 11-13 N/A 21-22 Common alarm volt free (opens on failure) 5-6 High/low (second stage) or outdoor sensor 14 Safety interlock 23-24 Boiler run volt free (closes on run) 7-8 DHW sensor or volt free thermostat 15 N/A 25-27 Power supply 9 N/A 16-17 DHW diverting valve or DHW primary pump, 240V signal to BMS (power supply live) F3 6.3 amp fuse B. OPTIONAL TERMINAL CONNECTIONS 15-16 System pump 22-23 DHW sensor 36-37 Extension timer 17-18 DHW pump 24-25 Flow temperature sensor 20-21 Outdoor sensor 34-35 Internal sensor

FLUE OPTIONS The Gas 110 Eco boilers have fan assisted flues supplied as standard, with a concentric flue outlet/air inlet connection used for room sealed operation, or for open flue (room ventilated) applications. An optional twin pipe fitting is available for the room sealed CLV system. The concentric system can be supplied for individual boilers for horizontal or vertical installation. Because of the excess fan capacity of the boiler, most flue lengths can be accommodated (depending on the boiler model and actual route taken), which enables installers to position the boiler almost anywhere in the building. Open flue or room ventilated systems can be installed as individual or combined flues and should discharge vertically, with the flue terminating in an optional tapered cone, complete with bird guard. Care needs to be taken when siting the actual discharge point as a vapour plume will be visible when the boiler is operating (maximum flue gas exit temperature will be less than 75ºC) and it s possible for water to drip to the ground from the terminal on horizontal installations, which could turn to ice in freezing conditions.

FLUE OPTIONS 17 TYPICAL FLUE OPTIONS 2 1 2 5 6 7 3 4 2 C001246 KEY 1 Flue type C13 Air/flue gas connection by means of concentric pipes to a horizontal terminal (so-called forced flue) 5 Flue type C53 Air and flue gas connection separated by means of a bi-flow adapter and single pipes (combustive air taken from outside) 2 Flue type C33 Air/flue gas connection by means of concentric pipes to a vertical terminal (roof outlet) OR 3 OR 4 Flue type C33 Air/flue gas connection by concentric pipes in the boiler room and single pipes in the chimney (combustive air in counter current in the chimney) Flue type C33 Air/flue gas connection by concentric pipes in the boiler room and single 'flex' in the chimney (combustive air in counter current in the chimney) Note: If further classification is required please refer to a specialist flue contractor. 6 7 Flue type B23P Chimney connection (combustive air taken from the boiler room) Flue type B23P Cascade installation compulsory accessories: Flue damper

TYPICAL FLUE SYSTEMS CONCENTRIC ROOM-SEALED APPLICATIONS (C13/C33) CALCULATION DATA ROOM-SEALED APPLICATIONS FLUE OPTION GAS 110 ECO 65 GAS 110 ECO 115 O/L O/L To suit site requirements O/L Maximum length O/L using 100/150mm concentric flue Maximum length O/L using 100/150mm concentric flue C13 9m 5.9m C33 11.5m 9.4m 90 Elbow an equivalent length of 1.9m 45 Elbow an equivalent length of 1.2m Inspection Tee an equivalent length of 3.3m Note: Flue lengths can be extended by using larger diameter flue pipe. For further clarification please consult a flue specialist and the Remeha technical department on 0118 978 3434. CONVENTIONAL FLUE B23P CALCULATION DATA CONVENTIONAL FLUE FLUE OPTION GAS 110 ECO 65 GAS 110 ECO 115 Maximum length O/L using 100mm single wall flue B23P 27m 19m O/L Birdguard and reduction cone 90 Elbow an equivalent length of 5m 45 Elbow an equivalent length of 1.2m Inspection Tee an equivalent length of 5.3m Note: Flue lengths can be extended by using larger diameter flue pipe. For further clarification please consult a flue specialist and the Remeha technical department on 0118 978 3434.

FLUE OPTIONS 19 CLV SYSTEM B53 CALCULATION DATA CLV SYSTEM (TWIN PIPE TWO ZONE) APPLICATIONS FLUE OPTION GAS 110 ECO 65 GAS 110 ECO 115 Maximum length O/L using 2 x 100mm single wall flue C53 23m 16m (11m air/ 5m gas) Birdguard O/L 90 Elbow an equivalent length of 5m 45 Elbow an equivalent length of 1.2m Inspection Tee an equivalent length of 5.3m Note: Flue lengths can be extended by using larger diameter flue pipe. For further clarification please consult a flue specialist and the Remeha technical department on 0118 978 3434.

The flue damper kit allows for safe and efficient operation of multiple Gas 110 Eco boilers when used on a common flue system. The following table offers flue system sizing guidance, based upon the total heat output and the available chimney height. Please consult a flue specialist or our technical department for any further assistance. MODULAR FLUE SYSTEMS Tapered cone c/w bird guard 100mm Boiler connections HEAT OUTPUT P BOILER TYPES ØD - ØD (MM) KW H-2-5M H-5-9M H-9-13M H-13-17M 122 2 x 65 155 145 184 3 x 65 220 200 195 190 244 4 x 65 265 240 230 225 305 5 x 65 305 275 255 250 366 6 x 65 340 300 280 275 214 2 x 115 200 185 180 321 3 x 115 285 255 240 235 428 4 x 115 345 305 285 275 535 5 x 115 395 345 323 315 642 6 x 115 440 385 355 345 Note: Connect the boilers to the horizontal header using swept connections.

FLUE OPTIONS 21 FLUE DILUTION SYSTEMS Bellmouth 2 x D + 50 D Opening in duct 2 x D 30 Drain Typical duct entry detail 100mm Boiler connections Note: Please contact a flue specialist for assistance with flue dilution system design. * Typical modular flue dilution system showing the flue break necessary for use on all pre-mix boilers. The flue break prevents the dilution fan affecting the gas/air ratio control system within the boiler. FLUE GUIDELINES Refer to the latest relevant British Standards. REF BS 5440-2: Specification for installation and maintenance of ventilation for gas appliances not exceeding 70kW (1st, 2nd and 3rd family gases). REF BS 5440-1: Specification for installation of gas appliances to chimneys and for maintenance of chimneys not exceeding 70kW (1st, 2nd and 3rd family gases). REF BS 6644: Specification for installation of gas red hot water boilers of rated inputs between 70kW to 1.8 MW (net) (2nd and 3rd family gases). REF IGE/UP/10: Installation of flued gas appliances in industrial and commercial premises. It's the responsibility of the installer to install the flues and fluecades to comply with the current regulations and standards. IMPORTANT NOTE All flue terminals and CLV kits are supplied with a condense drain/siphon this must be connected within one metre of the boiler flue connection. Any condensate which is able to flow back into the boiler from flue lengths greater than one metre must be discharged via a condense collector and drain system fitted within one metre of the boiler flue connection. Make sure that any flue gas outlet pipe to the boiler has a sufficient gradient (at least 50mm per metre) and there's a sufficient condensate collector. Where boilers have been installed on a common open flue system, condensate collectors and drain systems must be fitted on each individual boiler directly above the boiler flue connection. Condense siphons must be deep-seal water type with the discharge taken to a suitable drain point. Further information regarding flue with dissimilar metals can be found in BS6644 2011 Section 6.10.4. Concentric room-sealed flue components should not be mixed with single wall flue components. Flue components are constructed from a white painted metal outer and plastic inner. Flue terminals are painted as detailed in the terminal diagrams. Plume kit external components are aluminium or plastic and are painted black. All flue components are CE approved.

MODULAR/CASCADE OPTIONS AND SMART TECHNOLOGY 23 Spreading the total required heat output over several boilers in cascade configuration improves reliability and efficiency of the heat provision. MODULAR/ CASCADE OPTIONS 100 100 234 DN65-617 DN100-631 Remeha s Smart Connection Technology modular pipework kit has been designed to reduce installation time and simplify the planning of the primary circuit layout, for up to six boilers. The pipework kit comprises a flow and return assembly to each boiler which incorporates a suitably sized circulation pump, safety relief valve set at three bar and isolation valves. Each manifold (one per boiler) simply bolts together at 700mm centres, with a low loss header and connecting/blanking flanges completing the installation. The standard manifold provides connections for both in-line and back-to-back boilers. Simply blank off the connections not used with the caps contained within the kit. The pipework kits have been designed to operate at a minimum 15ºC T. 234 DN65: 114658 DN100: 114661 148 660 C001696 700 49 300 300 300 SMART CONNECTION TECHNOLOGY 1322 1100 DN65-617 DN100-631

SMART TECHNOLOGY AND COMPONENT LIST 25 For flue damper details contact our technical department. SMART CONNECTION TECHNOLOGY KIT COMPONENT LIST 100011491 100011490 DN65: 100011703 DN100: 100011492 111067 DN65: 111788 DN100: 111790 DN65: 114658 DN100: 114661 7608382 DN65: 112632 DN100: 112633 DN65: 111701 DN100: 111703 111708

TECHNICAL SUPPORT AND DECLARATION OF COMPLIANCE 27 TECHNICAL SUPPORT From brochures to CAD drawings and BIM files, you can access all the information you need at remeha.co.uk Or call our sales or technical departments on 0118 978 3434. We re always happy to help. We can provide you with: Brochures Technical specification sheets Case studies Installation manuals BIM files CAD files Energy-related Products Directive data Commissioning Technical information Spare parts (part of our after sales service). DECLARATION OF COMPLIANCE We hereby certify that the series of appliances specified herein is in compliance with the standard model described in the EC declaration of compliance, and that it is manufactured and marketed in compliance with the requirements and standards of the following European Directives. 90/396/EEC Gas Appliance Directive Reference Standards: EN 437; EN 483; EN 625; EN 677 2006/95/EC Low Voltage Directive Reference Standard: EN 60.335.1 2004/108/EC Electromagnetic Compatibility Directive Generic standards: EN 1000-6-3; EN 61000-6-1 92/42/EEC Efficiency Directive ErP compliant ECA listed.

Innovation House 3 Oaklands Business Centre Oaklands Park Wokingham RG41 2FD T 0118 978 3434 E info@remeha.co.uk W remeha.co.uk A Baxi Heating Brand Registered address: Baxi Heating UK Ltd Brooks House Coventry Road Warwick CV34 4LL Printed October 2016