Exit Stopper. STI-6400 Series

Similar documents
Exit Stopper. STI-6400 Series

Addendum for STI-6406 with Dual Access Control

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Installation and ZONES: Operation Manual. Model: ON STI-34108

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

STANDARD FEATURES SPECIFICATIONS

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Stopper II Heated Enclosure

Stopper II SERIES ADA. We protect the things that protect you

Illuminated Stopper Station Push Button

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Child Resistant Pool Alarms

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for models:

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Gate Mount Pool Alarms

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Installation Instructions

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

AL600ULADA. NAC Power Extender. Installation Guide

AED Alarm System Model Operations Manual

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Installation Guide for models:

WM3000 WIRELESS MODULES

EVO192 v3.0 Fire and Burglary What s New

COMPANY PROFILE PROTECTING THE THINGS THAT PROTECT YOU

AL800ULADA. NAC Power Extender. Installation Guide

ALARMED EXIT HARDWARE

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Series. Access Power Controllers. Installation Guide

Independent Zone Control (I.Z.C.)

ANNUNCIATOR FIXED MODULE

Alarmed Exit Hardware

PRX-320 Waterproof Proximity Access Operating Instructions and Installation Manual

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

MANUAL RESET ALARM RELEASE

Carbon Monoxide Transmitter

KT-100 Door Controller

4100U City and Relay Cards Installation Instructions

Installation Instructions

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

MANUAL RESET ALARM RELEASE

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

MODEL B2 INSTALLATION MANUAL

User Manual X8s Access Control System

Installation Instructions. CAR COMING Pedestrian Alert Safety Signs (PASS)

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Model 5100A, 5200A, and 5100ALBV Owner s Manual

TRX MAINS CONNECTION DIAGRAM

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

SPECIFICATIONS. Contents List

Go Smart. Go Wireless.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Pilfergard Door Alarms

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Product Catalog. For specs & details go to sti-usa.com 1

General Purpose IO Technical Manual

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

Model 4001 Series Single Channel Controller

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

CORNELL Emergency Response Systems

DE5300 Delayed Egress System. General Information

Go Smart. Go Wireless.

Product Catalog. For specs & details go to sti-usa.com 1

WIRING DIAGRAM AND INSTRUCTIONS

Pump-Up Controller MODEL 4062

Public Safety DAS Annunciator Panel

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

Wireless D.I.Y. Alarm Kit

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Remote Display Alarm Indicator for Oxygen monitor

ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2

Pump-Down Controller MODEL 4052

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Transcription:

Exit Stopper STI-6400 Series Features Alarm helps prevent unauthorized exits/entries through doors. Easy to install. Select volume, alarm duration and delay settings. May be mounted on top, right, left or next to almost any door. User can select on-site whether to use an alarm or annunciator. Less expensive than heavy horizontal bar type units and practical for all emergency doors. Contact STI for custom applications. We protect the things that protect you. - 1 -

Table of Contents Warnings and Cautions... Page 2 Warranty Information... Page 2 Specifications... Page 3 1. Dimensions... Page 3 2. Polycarbonate... Page 3 3. Electronics... Page 3 4. Remote Horn... Page 3 Circuit Board Set-Up... Page 4 Terminal Strip Layout... Page 4 Switch Settings... Page 4 Alarm Feature Description... Page 5 Installation Instructions All Units / STI-6400... Page 5 Mounting Options... Page 6 STI-6402 Double Door additional install notes... Page 6 STI-6403 Remote Horn additional install notes... Page 6 STI-6404 Double Door with Remote Horn additional install notes... Page 6 STI-6405 Exit Stopper with Momentary Reset... Page 6 Warnings All units are recommended for indoor use, not for outdoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase additional exit stopper units. When purchasing a remote unit (STI-6403 or STI-6404) you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Maximum of three remote alarms may be used in parallel. All specifications and information shown are current as of publication and subject to change without notice. Warranty Information Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14-2 -

Specifications Polycarbonate Enclosure Dimensions 5.375 W x 5.375 H x 2 D (137mm x 137mm x 51mm) Flammability UL94 V-2 Wall Thickness 0.12 in (3.05mm) Electronics: STI-6400 - All Units 9 VDC Alkaline or 9V-24VDC wired Power Source Class II UL Listed transformer Horn Volume at 1 ft. 95 db low / 105 db high Relay Output Form C Dry Contacts 0-30 VDC or VAC, 1 Amp Stand by Current 10uA Alarm Current 130mA at 95 db / 200mA at 105 db Operating Temperature Range 32 to 113 F (0 to 45 C) Electronics: STI-6403 and STI-6404 - Remote Horn Unit Power Source 9 VDC operating power* only Horn Volume at 1 ft. 95 db low / 105 db high Stand by Current 0 A Alarm Current 50mA at 95 db/ 200 ma at 105 db * Power source for the STI-6403 and STI-6404 Remote Horn uses a separate power source from the STI-6400 alarm. The Remote Horn contains an internal 9 volt battery. Horn operates when the Form C contact at main unit is activated on alarm. - 3 -

Circuit Board Set-up ALARM VOLUME SWITCH (ON) DOOR PROP SWITCH (OFF) JP2 JP5 TERMINAL BLOCK ALARM DURATION SWITCH (OFF) (OFF) JP4 JP3 (FACTORY DEFAULT SETTINGS) ARMING SWITCH (ON) JP7 FORM C DRY CONTACTS REMOTE POWER INPUT 9-24 VDC REED SWITCH TERMINALS KEY SWITCH TERMINALS NC COM NO GD V+ RS1 RS2 KEYSW TERMINAL BLOCK WIRING CONNECTIONS Figure 1 STI-6400, STI-6403 and STI-6405 are shipped with jumper installed for use with one reed switch (RS2). If using second reed switch, remove jumper and insert second switch. Switch Settings FEATURE JP2 JP3 JP4 JP5 JP7 Volume - POLYCARBONATE High (105 db) BASE at 1 ft. ON* Volume - Low (95 db) at 1 ft. OFF Duration - 30 Second Alarm OFF* OFF* Duration - 180 Second 120 db HORN Alarm OFF ON Duration - Continuous Alarm ON OFF Duration - Annunciator Mode ON ON Trip - Immediate POLYCARBONATE COVER Door Prop Mode Arming - Immediate Arming - 30 Second Delay OFF* ON ON* OFF Slide black lever to desired ON/OFF position as labeled on circuit board. *Factory Settings - 4 -

KEYSW NC COM NO GD V+ RS1 RS2 KEYSW Alarm Feature Description Volume Switch JP2 - Sets alarm volume to high 105 db or low 95 db. Duration Switch JP3 and JP4 - Amount of time alarm sounds after trip. Arming resets at end of duration if door is closed. Alarm will not reset if in continuous mode; alarm will sound until reset with the key or until battery is drained. Annunciator mode will sound a series of short beeps until door is closed or 15 seconds. Door Prop Mode Switch JP5 - Once unit is armed with the key (OFF to ON) the alarm will sound if the door remains open for 15 seconds. If the door opens and closes within 15 seconds, the alarm will not sound. Arming Delay Switch JP7 - Delays arming of alarm for 30 seconds. To start arming delay timing, cycle the key switch (OFF to ON). Door must remain closed for 30 seconds for alarm to arm. Test Alarm Note: STI recommends testing the alarm in factory settings (see Switch Settings) prior to mounting. 1. Make sure key switch is in the OFF position. 2. Remove tamper screw on the side of the unit using the tamper wrench provided. Remove housing cover. Save the tamper wrench for future service and battery replacement (Fig. 2). 3. Connect battery. 4. Place magnet next to reed switch. Note: For STI-6402 model, insert jumper in RS2 terminals or install second reed switch and place magnet next to reed switches 1 & 2. 5. Turn the key switch to the ON position. 6. Move magnet away from reed switch. Unit should alarm immediately. 7. Turn unit off with the key to silence alarm. Installation Instructions 1. Set switches on circuit board to desired alarm settings (Fig. 1). 2. If using external power source, use Class II UL Listed transformer. 9V battery will be in no-load standby. 3. Mount main unit on or next to the door using hardware provided. Reed switch may be moved to one of four positions shown in Fig. 2 or you may route the reed switch through the knockout in the bottom of the cover as shown in Fig. 3. 4. Mount magnet using hardware provided. Magnet must be within ¾ of the reed switch when door is closed. Please refer to figures 7, 8 and 9 for other mounting options. Note: When mounting on metal doors or door frame, use plastic spacers provided. Magnet must be within 3/8 of the reed switch when door is closed. 5. If installing STI-6402, STI-6403, STI- 6404 or STI-6405 continue to page 6. 6. Replace cover by sliding flanges on inside of cover into slots on base, snap closed and replace the tamper screw. 19039 SCREW 6 x 1 1/4 in. - 5 - EMERGENCY USE ONLY ALARM SOUNDS WHEN DOOR IS OPENED ON OFF NC COM NO GD V+ RS1 RS2 KEYSW FLANGES COVER REED SWITCH MOUNTING LOCATIONS (LABELED 1-4) VIEW SHOWING MAGNET INSTALLATION MAGNET COVER 4 19014 MOUNTING SCREW (4) PROVIDED SLOTS 1 TERMINAL STRIP 9 VOLT BATTERY 2 19011 TAMPERPROOF SCREW (1) PROVIDED 3 19016 TAMPER WRENCH BASE (1) PROVIDED FLANGES REMOVE FRONT COVER AND ROUTE REED SWITCH WIRES THROUGH NOTCH ON BOTTOM SURFACE AS SHOWN MAXIMUM GAP 3/4 in. (19mm) 3/8 in. (9.5mm) ON METAL DOOR AND FRAME REED SWITCH MOUNTING LOCATIONS SPACERS (USE AS NECESSARY) NOTE: 2 SPACERS UNDER BOTH 4 MAGNET AND REED SWITCH MUST BE USED ON STEEL DOORS 19018 ANCHOR Figure 2 Figure 3

STI-6402 Double Door Install Notes 1. If not using extra reed switch, add jumper across two terminals of RS2 on terminal block. 2. Determine length needed for reed switch wires. STI provides 1 reed switch with 6 ft. wires. Cut to desired length. 3. Connect first reed switch in RS1 and second in RS2 (Fig. 5). (Refer to Fig. 1 for additional details.) *Note: Alarm will sound when either door is opened. TERMINAL BLOCK OPTIONAL: TO REMOTE HORN STI-6403 INTERNAL REED SWITCH (RS1) TO KEY SWITCH VIEW SHOWING INSTALLATION OF ADDTIONAL REED SWITCH 06402 06402 REED SWITCH (RS2) Figure 4 STI-6403 Remote Horn Install Notes 1. Remove cover. 2. Connect two conductor wire (14-24 AWG) from main unit terminal block pins COM and NO to remote horn unit terminal block. (wire not provided). Units can be set up to 300 ft. apart. Not polarity sensitive (refer to Fig. 1 and Fig. 5 for details). 3. Connect internal battery. 4. Mount similar to main unit with #8 x 1 in. screws and anchors if necessary. 5. Replace cover and screws. 6. Turn key switch to ON position. *Note: The ON/OFF key position is opposite from 6400 main unit. Remote horn sounds when main unit alarm is activated. ROUTE WIRES THROUGH NOTCH KEY SWITCH STI-6403 REMOTE HORN UNIT INSTALLATION Figure 5 STI-6404 Double Door with Remote Horn Install Notes The STI-6404 is a combination unit for double doors with a remote horn. Reference the installation instructions for the main unit, the STI-6402 and the STI-6403 for complete installation. STI-6405 Exit Stopper with Momentary Reset The STI-6405 uses a momentary switch. After initial installation, unit is always on and you do not have to remember to turn it on when you leave a protected area. This model also eliminates having to remember to re-arm it because it is never off. When the alarm is triggered, to silence the alarm, insert the key and turn completely to the RESET position and hold for 2 seconds, then release. The switch will spring back to its original position and push the key out. To turn the unit off, supply power must be removed. - 6 - RESET Figure 6

INSTALLATION 19039 SCREW Mounting 6 Options x 1 1/4 in. 19039 SCREW 6 x 1 1/4 in. MAGNET MUST BE INSTALLED OPPOSITE RAISED RIB ON OUTER COVER SPACERS - USE NOTE: (2) SPACERS MUST BE AS NECESSARY USED ON STEEL DOORS TYPICAL FLUSH MOUNT DOOR JAMB INSTALLATION 19018 ANCHOR MAGNET MAGNET MUST BE INSTALLED OPPOSITE 6400 UNIT RAISED RIB ON OUTER COVER SPACERS - USE NOTE: (2) SPACERS MUST BE AS NECESSARY USED ON STEEL DOORS DOOR 19018 ANCHOR MAGNET SWING 6400 UNIT DOOR SWING JAMB DOOR STOP DOOR JAMB DOOR STOP DOOR Figure 7 TYPICAL RECESSED MOUNT DOOR JAMB INSTALLATION MAGNET ASSEMBLY (SEE ABOVE FOR INSTALLATION) TYPICAL RECESSED MOUNT DOOR JAMB INSTALLATION DOOR STOP MAGNET MAGNET ASSEMBLY (SEE ABOVE FOR INSTALLATION) 6400 SWING DOOR STOP 3/4 in. (19mm) MAXIMUM GAP 3/8 in. (9.5mm) ON METAL DOOR AND FRAME 3/4 in. (19mm) MAXIMUM GAP 3/8 in. (9.5mm) ON METAL DOOR AND FRAME DOOR SWING MAGNET 6400 SWING *Note: When mounting reed switch on door and the main unit on wall, wire DOOR service loop must be used. SWING Figure 8 TYPICAL DOUBLE DOOR INSTALLATION STI-6402 INTERNAL REED SWITCH (RS1) - 7 -TO KEY SWITCH Figure 9

2306 Airport Rd Waterford, MI 48327 Phone: 248-673-9898 Fax: 248-673-1246 info@sti-usa.com www.sti-usa.com Safety Technology International (Europe) Ltd. Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 E-mail: info@sti-europe.com Web: www.sti-europe.com Printed in USA Subject to change without notice. - 8 - Inst. 6400 SEPT2014