V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

Similar documents
MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

2 shp 13 lc 1 36 t - 1 a

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

ASHRAE 90.1 COMPLIANT 6 to 36 Tons

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

13 GEP A L P - 1 A

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

RGE 13 A T - 1 A

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

T P A 120 S 4 S N 1 Y

Lennox 8 Series Single Zone - R-410A

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

14 AC x

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

Visit us at For the latest technical information,

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

CB X 32 mv

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

INDOOR AIR QUALITY CCWH Complete Comfort Whole-Home Dehumidifier ENGINEERING DATA. Nominal Capacity - 65 to 135 pints per day CCWH - 090

T P A 048 S 4 N 4 1 T

MERIT SERIES Downflow

T S A 048 S 4 N 4 1 T

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Bosch BVA Series Air Handler

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

PRODUCT SPECIFICATIONS

INSTALLATION INSTRUCTIONS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

ELITE SERIES Downflow - High Efficiency Blower Motor

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

Air Conditioner SVC MANUAL(Exploded View)

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

Air-Cooled Condensing Units with Compact Screw Compressors

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

Corp L2 Revised

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

ELITE Series Variable Capacity

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

CBX32MV (HFC-410A) SERIES UNITS

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

Commercial High-Efficiency Condensing Units

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Product Catalog Split System Air Conditioners Odyssey

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Bosch BVA Series Air Handler

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

C22 Bulletin # October 1993 Supersedes May 1993

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

TECHNICAL SPECIFICATIONS

Engineering Data Book

Engineering Data Book

HEAT PUMP INSTALLATION MANUAL

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

Submitted to Reference Approval Construction Unit Designation Schedule #

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

ELITE Series R-410A - Two-Stage Compressor

Installation Instructions

C22FC Bulletin # October 1993 Supersedes May 1993

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

Submitted to Reference Approval Construction Unit Designation Schedule #

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

High Profile Evaporator

Split System Cooling Product Data

Ductless Split Systems Ceiling Cassette Heat Pumps

Engineering Data Book

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

Transcription:

PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF V8MS Mode Selection Box for VRA Heat Recovery - 60HZ Bulletin No. 070 March 06 Supersedes July 04 Allows simultaneous heating and cooling of multiple zones. Used with VRA Heat Recovery outdoor units. Comprised of a series of solenoid valves that control refrigerant flow through each indoor unit based on the operational mode selected for that indoor unit. NOTE - For indoor use only. CONTENTS Dimensions...4 Electrical Data... Installation Clearances...5 Mode Selection Box Details...3 Sound Data... Specifications... V8MSBB0 V8MSBB0 V8MSBB03 V8MSBB04 APPROVALS Units are ETL certified for the U.S. and Canada. WARRANTY Components - Limited one year. FEATURES V8MSBB0 (A53) - group, indoor unit maximum. V8MSBB0 (A54) - groups of 4, 8 indoor units maximum. V8MSBB03 (A55) - 4 groups of 4, 6 indoor units maximum. V8MSBB04 (A56) - 6 groups of 4, 4 indoor units maximum. Linear Expansion Design - Regulates the flow of refrigerant and reduces sound levels. Flare Fittings - For indoor unit pipe connections. Sweat Fittings - For outdoor unit pipe connections. Removable Panels - Removable side and bottom panels for maintenance access. Adaptors Furnished - Includes two kits to adjust to a larger pipe size for smaller indoor units. (/4 in. to 3/8 in. and / in. to 5/8 in.).

SPECIFICATIONS General Data Model Number V8MSBB0 VBMSBB0 V8MSBB03 V8MSBB04 Maximum Number of Indoor Unit Groups 4 6 Maximum Number of Indoor Units in Each Group 4 4 4 Maximum Number of all Downstream Indoor Units 8 6 4 Valve Type Solenoid Solenoid Solenoid Solenoid Capacity Maximum Capacity Each Indoor Unit Group (Btuh) 96,000 54,000 54,000 54,000 Total Capacity of all Downstream Indoor Units (Btuh) 68,000-96,000 96,000 54,000 54,000 Piping Connections Connection to Outdoor Unit Connection to Indoor Unit Liquid line O.D. - in. / / 5/8 5/8 High Pressure O.D. - in. 3/4 3/4 7/8 7/8 Low Pressure O.D. - in. 7/8 7/8 -/8 -/8 O.D. - in. 3/8 3/8 3/8 3/8 O.D. - in. 5/8 5/8 5/8 5/8 3 Drain connection O.D. - in. Dimensions and Weight Data Control Wiring (AWG) Unit dimensions (H x W x L) 9 x 3-5/8 x 4-3/4 9 x 3-5/8 x 4-3/4 9 x 3-5/8 x 37-3/4 9 x 3-5/8 x 37-3/4 Unit weight (net / shipping) - lbs. 43 / 60 43 / 60 69 / 88 77 / 98 8 gauge (3-core shielded) ELECTRICAL DATA Line voltage data - 60 hz - ph 08/30V 08/30V 08/30V 08/30V Input (W) 30 30 50 70 3 Maximum Overcurrent Protection (amps) 5 5 5 5 4 Minimum Circuit Ampacity 0.0 0.0 0.35 0.50 3/8 x /4 in. adaptor furnished for liquid pipe connection to indoor unit (if required). 5/8 x / in. adaptor furnished for gas pipe connection to outdoor unit (if required). 3 x 3/4 in. condensate drain adaptor furnished for field installation (if required). 4 HACR type circuit breaker or fuse. 5 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. SOUND DATA Model No. Sound Pressure Level - dba - STEADY STATE V8MSBB0 VBMSBB0 V8MSBB03 V8MSBB04 Heating 37 3 3 Cooling 34 3 36 Main Heating 39 36 34 Main Cooling 33 36 3 V8MS Box 39-3/8 (000) The majority of indoor units are operating in cooling or heating mode. Model No. Sound Pressure Level - dba - MODE SWITCHING V8MSBB0 VBMSBB0 V8MSBB03 V8MSBB04 Minimum 50 48 5 Maximum 53 5 6 This data represents the instantaneous peak data during mode switching. NOTES: Sound measured at 68 F ambient temperature at MS Box. Tested in semi-anechoic room. Measured from the bottom of the unit. V8MS Mode Switching Device / Page

MODE SELECTION BOX DETAILS MODE SELECTION BOX FOR HEAT RECOVERY OUTDOOR UNITS V8MSBB0 (Maximum No. of Groups x Indoor Units - x = ) V8MSBB0 (Maximum No. of Groups x Indoor Units - x 4 = 8) Low Pressure High Pressure V8MSBB03 (Maximum No. of Groups x Indoor Units - 4 x 4 = 6) Low Pressure High Pressure V8MSBB04 (Maximum No. of Groups x Indoor Units - 6 x 4 = 4) Gas pipe Liquid pipe Low Pressure High Pressure V8MS Mode Switching Device / Page 3

DIMENSIONS - INCHES (MM) V8MSBB0, V8MSBB0, V8MSBB03, V8MSBB04 9 (9) MOUNTING LUGS (4) CONDENSATE DRAIN (5) dia. 3-5/8 (600) -/4 (3) CONNECTIONS TO INDOOR UNITS CONNECTIONS TO OUTDOOR UNIT LOW PRESSURE GAS PIPE TO OUTDOOR UNIT HIGH PRESSURE GAS PIPE TO OUTDOOR UNIT LIQUID PIPE TO OUTDOOR UNIT GAS PIPE LIQUID PIPE B A Model No. A in. mm in. mm B V8MSBB0 4-3/4 69 9-/4 489 V8MSBB0 4-3/4 69 9-/4 489 V8MSBB03 37-3/4 959 3-/4 89 V8MSBB04 37-3/4 959 3-/4 89 Pipe Diameter - in. Model No. Connections to Outdoor Unit Low Pressure High Pressure Liquid Pipe Connections to Indoor Unit V8MSBB0 7/8 3/4 / 3/8 5/8 V8MSBB0 7/8 3/4 / 3/8 5/8 V8MSBB03 -/8 7/8 5/8 3/8 5/8 V8MSBB04 -/8 7/8 5/8 3/8 5/8 3/8 x /4 in. adaptor furnished for liquid pipe connection to outdoor unit (if required). 5/8 x / in. adaptor furnished for gas pipe connection to outdoor unit (if required). V8MS Mode Switching Device / Page 4

INSTALLATION CLEARANCES - INCHES (MM) CONCRETE CEILING -7/8 (300) Minimum REFRIGERANT PIPE PIPE HANGER (5) Minimum SUSPENDED CEILING 59 (500) Maximum 59 (500) Maximum 4 (60) NOTE - A suitable sized access panel is required to provide full access to electrical panel. ELECTRICAL PANEL 5-3/4 (400) CONNECTIONS TO OUTDOOR UNIT 9-3/4 (50) Minimum CONNECTIONS TO INDOOR UNITS 36 (94) Minumum NOTE - An access panel is recommended for gaining access to flare nuts or isolating ball valves if mounted above a solid ceiling. V8MS Mode Switching Device / Page 5

REVISIONS Sections Electrical Data Sound Data Description of Change New section. New section Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 06 Lennox Industries, Inc.