966A AIR IONIZER. SUMITOMO 3M LIMITED Electronic Solutions Division

Similar documents
ELIMINOSTAT DC-ESR-CL-S2

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Ionizer (Static Remover) STABLO-EX Instruction Manual

Thank you for purchasing our Stat Clean No. BBZ-E. Read this instruction manual before use. Keep it in a safe handy place for future reference.

3 963/963E Benchtop Air Ionizer Instructions

Instruction Manual STATIC ERASER TOP FAN. Table of Contents

Eagle 2500 TM OWNER S MANUAL. Electronic Air Purification 110 and 220 volt Systems. EcoQuest International. Application.

OPERATION INSTRUCTION

16 mm. Ionizer Nozzle type. Ion balance ±10 v. Slim design: Thickness dimension 16 mm RoHS compliant. Series IZN10

model No: ir20.v2 FUSE

Page 1 of 18. Part# /5/2013

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

IMPORTANT INSTRUCTIONS OPERATING MANUAL

STATIC ELECTRICITY SOLUTION APPLICATION SHEET

IONIZING AIR BLOWER INSTRUCTION MANUAL

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

NON-DUCTED TYPE SMOKELESS BBQ ROASTER MODEL NJG-C

ULTRA LOW TEMPERATURE FREEZER. User Manual

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

SYSTEM Inverter Air Conditioners

Models: GW/R-T GW/R-2-T GW/R-3-T

3M Benchtop Air Ionizer 963E. User s Guide

Instruction Manual for Dust Collector

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

BL Series INSTRUCTIONS

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Installation/Instruction Manual

Bench Top Ionizer Installation, Operation and Maintenance

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

AIR PURIFIER CLASSIC INSTRUCTION MANUAL. CAUTION: Read manual carefully for correct procedures and proper operation.

YC ON-OFF SERIES. Service Manual

Inverter Split-type Room Air Conditioner

INSTRUCTION MANUAL 4HP WET / DRY VACUUM VC V 60 Hz 7A. Gal

Requests for Daily Care and Maintenance

JT-SB116JH-G-NA JT-SB116JH-W-NA

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Read this Safety Guide first.

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

Electric Hand dryer. Installation and operating manual

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

Intelligent Swing Gate Turnstile Operating Manual CPW-322CS

SLP98UH SERIES VARIABLE CAPACITY GAS FURNACE WARNING WARNING

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

CA3500, BA3500, CH3500 New Comfort

THE ENVIROFLEX ESE201A-W-2 PORTABLE SMOKE EXTRACTOR OWNER S MANUAL

infrared paraffin / kerosene / diesel heater

AiRTX Static Elimination

USER MANUAL. 60cm, 3 burners, Hob AKC 630

Intelligent Super Toilet AFC230 User Instruction Manual

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Models TX-KE and TX-KP Toxic Gas Transmitters

INSTALLATION AND OPERATIONS MANUAL

EL195UHE SERIES GAS FURNACE WARNING WARNING

Coway Air Purifier AP-1008DH

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

Tornado Operations & Maintenance Manual

WARNING FIRE OR EXPLOSION HAZARD.

Chargebuster Ion Gun Installation, Operation and Maintenance

WARNING FIRE OR EXPLOSION HAZARD.

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

Operator s Manual. 6 Gallon Model No. VQ607SFD FOR YOUR SAFETY. Read and understand this manual before use Keep this manual for future reference

Chargebuster Ion Gun Installation, Operation and Maintenance

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

300KV Van de Graaff Generator Kit Builders Manual

USER MANUAL. 80 cm 2 burners, glass hob AKC 820C/BLM

Series: MBC1-TC Mini Benchtop Temperature Controller

Polti S.p.A. reserves the right to change equipment or accessory specification without prior notice.

Operation Manual RANGE HOOD

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

OWNERS MANUAL. Installation. Operation. Specifications. Features. Maintenance. Warranty REV 02_04 FA SP-ENG OM - 02_04

YOUR PORTABLE AIR PURIFIER

Operation regulations must be strictly obeyed.

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

Operator s Manual. 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY. Read and understand this manual before use. Keep this manual for future reference.

CF-100 Food Waste Fertilizer OPERATION MANUAL

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Operating Manual. Model 940/942 Ionising Air Nozzles

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Static Control in the Plastic Bottling Industry

ZJ-FA10. Advanced Ionizer with Visible Discharge Status. Ionizer (Advanced Fan Type) Features. Sensing Charge and Discharge Status

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

TLA-1245 EFFICIENT HEAT CYCLE SHRINK TUNNEL OPERATION MANUAL

REFRIGERATOR - FREEZER OPERATION MANUAL

ScrubMaster 26C OPERATING & MAINTENANCE

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Antari Low Fog Machine

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

INSTRUCTIONS AND WARRANTY

FATG OM 0604 OWNERS MANUAL. Anywhere. Everywhere. Fresh Air... To Go.

EFX 600. aquamanta. Instruction Manual. 4year guarantee. the experts in aquatic technology. >600 Litres

PROLUX AIR PURIFIER / HUMIDIFIER MODEL: PL-2 Operation Instruction

400KV Van de Graaff Generator Kit Builders Manual

Sanitary Water Tank INSTALLATION & SVC MANUAL

Transcription:

966A AIR IONIZER Operation Manual Precautions...1 Safety precautions...1 Other precautions...1 Outline...2 Structure and kinds of the ionizer...2 Specifications...2 Characteristic...3 How to Install 966A air ionizer...3 Installation and Wiring...4 General for ionizer installation...5 How to install...5 Layout of air...5 Operations...6 Maintenance....7 Trouble shooting...7 Thank you for purchasing the 3M TM 966A Air Ionizer. Before installing and using the product, please read this operation manual carefully and be sure you fully understand all safety information and operating procedures. Please store the manual in a secure location for convenient reference. If you need further help on the instructions and precautions given here, please contact a Sumitomo 3M sales representative or authorized dealer. <3M> is a trademark of 3M Company.

Precautions Safety precautions Read this operation manual carefully before installing and using this product and be sure to use the product correctly. WARNING The 966A AIR IONIZER does not incorporate explosion-proof specifications. Do not install or use it in a location or environment where flammable gases or solvents are present. There is a danger of fire or explosion. The tip of the emitter needle is sharp. Use sufficient caution when handling it. The tip can cause injury. This product must not be opened inside the unit. High voltage may cause injury or dead. Be sure to supply the clean & dried air to this device. CAUTION! Please use with optional nozzle. When cleaning the 966A housing or emitter points, verify that the unit is off and disconnected from electrical power. The 966A is designed for use in those areas using AC 100-120 V electrical service. Usage of unit with the incorrect electrical voltage could result in incorrect performance and an unsafe operating condition. If the air includes water and oil, the electrode gets dirty, the ability to remove electricity is lowered, or causing deterioration of the electrode In an abnormal condition, please contact our company because adjustment or repair by manufacture is necessary. If a condition in which no air is supplied continues, the red lamp may be lit on. Other Cautionary Statements Complete the necessary information on the enclosed warranty card (postcard), and be sure to return it to Sumitomo 3M. Failure to do so may prevent you from receiving services such as repair, replacement, and inspection. Do not disassemble the product or subject it to rough treatment or strong impacts. Malfunctions resulting from these causes are not covered by the warranty, even within the warranty period. 1

Outline This IONIZER is, as a countermeasure against static electricity, a quick-acting air-blow type IONIZER. Ion air neutralizes static electricity of charged objects immediately and effectively and removes dust to the objects by static electricity to prevent contamination. Structure and Kinds of the Ionizer This IONIZER consists of the following parts: Optional Nozzles, an electrode, a high-voltage transformer, and the body of 966A in which has warning display circuit at the time of abnormal condition. It applies high-frequency-high-voltage from the high-voltage transformer to the discharge needle inside, giving off alternating current corona discharge toward the metal cap (grounding terminal), and produces positive and negative air ion. It transfers the air ion by air. The Ion air neutralizes static of charged objects located away and removes dust stuck to the charged objects. The characteristic of this equipment is that it can transfer ion air by using the optional air tube in addition to air-blowing directly through the air nozzle. OUTLOOCK of 966A AIR IONIZER Specifications Method to Generate Ion Corona discharge with high frequency Input Voltage DC24V±5 Capacity 2.4 VA Output Voltage AC 2.0kV Size 87.2L x 18W x 50.7H Main Body Only Temperature for Use Between 5 to 40 degree 2

966AS 0.050.45MPa 966AP1,P3 0.050.45MPa 966AT 0.050.45MPa Characteristics Abnormal Output Circuit Ozone Generation B contact without voltage 0.04ppm : Measured Distance 300mm How to install 966A Air Ionizer The metal cap of the nozzle part in the electricity-removing equipment does not touch the metal frame. Installment holes(4-3.5 dia) M 3

Don t touch the Air-cap and Tube and Pipe to the grounding object. Don t touch the metal frame. Installation and Wiring ALARM POWER First take off the cover cap of discharge needle. In case of blowing ion air directly form the nozzle 966AS Screw the 966AS air nozzle completely into the IONIZER body. Installation of the equipment should be arranged so that the air nozzle will be pointed to the charged object and air will be blown against it. 966ATTeflon tubein case of transferring ion air through a tube form the nozzle Screw the 966AT air nozzle completely into the IONIZER body. Install this equipment at a roomy place and lay tubes to the charged object located in a small space. Lay the tip of the tube closer to the charged object. 966AP1, 966AP3In case of transferring ion air through a pipe form the nozzle Screw the 966AP1,P3 air nozzle completely into the IONIZER body. Install this equipment at a roomy place and lay pipes to the charged object located in a small space. 4

General for Ionizer Installation At the time of installing the equipment, pay attention to stain caused by water and oil, high temperature, and humidity. and especially a very humid place with a possibility of appearance of dewdrop should be avoided. The best installation place of the electrode to remove electricity is just in front of the place where troubles are caused by static electricity. If the electrode to remove electricity is installed at the place the charged object touches or is closer to another object, the effect of removing electricity can not be obtained, so install the equipment at a place where the charged object is floating in the air. object Un-effective point Effective point ionizer Effective point Un-effective point How to Install Install it at a designated place by using installment holes (4-3.5 dia), (in case install as vertical use with optional flame while seeing it that the metal cap of the nozzle part in the electricity-removing equipment does not touch the metal frame. Supply DC24V to the power source connector of the equipment. A power and signal cable is attached. An adapter of input AC 100V is Option. In case supply the DC power, make sure that attach the Air cap. Layout of Air Install the air hose Outside diameter 6mm at the air-inhaling part of the equipment. Extend the air hose to the air source (Air compressor, Blower ) through the pressure adjuster. Supply pure air (air which does not include water and oil) to the electrode. 5

Operation 1. Install the equipment at a designated place, and conduct power source wiring, grounding wiring, and air laying.) 2. Supply DC24V through the power source connector of the equipment. The power source of high voltage starts and corona discharge is generated at the discharge electrode, producing air ion. When the power source is supplied, the green LED (in the normal condition) is lit on. 3. Open the main valve of air equipment (installed by your company), and supply air to the nozzle with designated pressure after adjusting the pressure adjuster. Ion air is blown out from the nozzle and static electricity of the charged object placed in the air-flow is neutralized and removed. Pay attention to excessive air pressure, which will lower the effect of removing electricity. Use it below the upper limit. 4. When you attach the tube to the nozzle, move the tip of the tube closer to the charged object and blow ion air. 5. Abnormal Warning Display (red light of LED ----- bad condition of removing Electricity Abnormal Warning Display (at the time when LED red light is on.) is installed in this equipment so that the abnormal condition will be cleared away immediately. The possible typical causes for the lighting of red lamp are as follows: Lowered high-voltage output Loosened metal cap (incomplete tightening), condition of touching the grounding belt. Dirt or dust sticking to the electrode, creating a condition similar to a short circuit between the discharge needle and the earth.). 6. Structure of Abnormal Output Circuit (Open Collector) Clear of Abnormal Condition :red LED light When the LED is lit on, carry it out after supply of input power source is stopped. Check the metal cap or Pipe or Tube does not touch the ground. Object. Check the looseness of the metal cap Remove the metal cap, clean up the insulating part of the body grounded discharge needle with isopropyl alcohol, and attach the metal cap. 7. High Voltage Circuit (MOS FET Relay) Main Circuit :DC24V :DC0V :GND :ALARM :ALARM DC24V LORD DC30V 0.2A MAX DC 24V POWER&SIGNAL CABLE RED: INPUT POWER DC+24V5% BLACK:POWER GROUND YELLOW:ALARM OUTPUT NC WHITE:ALARM OUTPUT NC GREEN:CIRCUIT GROUND Inside Circuit Outside Cicuit ALARM OUTPUT CIRCUIT 6

Maintainance Since the insulator, which is a part of the electrode of removing electricity, gradually becomes deteriorated with exposure to alternating high-voltage electric field, it is necessary to regard it as an expendable supply. The expected life span is thought to be 10,000 hours even if sufficient maintenance is conducted, and replacement is recommended. If the maintenance is not sufficient, its life span will be shorter. The maintenance is very important. This equipment is supposed to be placed at a place where it is free from water and oil, etc...if it were splashed with water, oil, or paint, wipe it out with waste or cloth. A special attention is necessary for the high-voltage Clean-up of the Discharge Needle and Its Surrounding Area. The dirty tip of the discharge needle lowers the ability to remove electricity. When the effect of removing electricity is declining, clean it up with a nylon brush. (Do not use a wire brush.) Revolve the metal cap of the nozzle and take it away from the pipe body, and clean up the discharge needle and its surrounding area inside the pipe with waste or a brush. After the cleanup, put the metal cap back firmly. Make sure the polarity of DC power as +(Positive) and (Negative). In case DC power of 966A turn on after within one second as turned off, the alarm signal send out. To keep over one second without mis-signal send out. When the air will not be supplied, also the DC power must be turned off. It makes same damage by OZON in side nozzles. Trouble Shooting In Case Of Dying Out Of Removing Electricity In case of no lighting of the LED red or the green lamp. *Check normal supply of DC 24V of the input power source. In case of lighting of the LED red lamp. *See the above-mentioned Clear of Abnormal Condition. The technical information given in this manual is based on testing carried out by Sumitomo 3M. It does not represent a guarantee. This manual may be changed without advanced notice due to product characteristic or design improvements, or for other reasons. Before using this product, verify that it is in fact suitable for the intended purpose of use. Sumitomo 3M accepts no responsibility for damages resulting from incorrect use or other mishandling of the product. This manual was created based on information that is current as of January 2008. 7