Testing and Calibration Report

Similar documents
HEALTH & SAFETY ARRANGEMENTS FOR PORTABLE APPLIANCE INSPECTION & TESTING

Management Standard: Portable Appliance Testing

Electrical Management

Understanding and implementing an electrical safety regime in your organisation. Dispelling the myths and promoting a risk-based approach

TESTSAFE. minipat APPLIANCE TESTER USER MANUAL

PAT: Portable Appliance Testing

THE SAFE USE OF ELECTRICITY

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

FIRE SAFETY LOGBOOK ADDRESS OF PREMISES NOMINATED RESPONSIBLE PERSON

BASIC FIRE SAFETY GUIDANCE AT UCL STUDENT HALLS OF RESIDENCES

Use numbers given in the box to complete the following sentences. In the UK, the mains electricity supply is volts.

Who are the Electrical Safety Council? Contents. Page

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

PERIODIC ELECTRICAL TESTING POLICY

Periodic Electrical Testing Policy

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

Who are the Electrical Safety Council? Contents. Page

Fire Safety Protocol

ECOLEC PANEL HEATERS GENERAL NOTES.

DEVIL CERAMIC SPACE HEATERS

PREMISES FIRE SAFETY LOGBOOK

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

Q1. The diagram shows the inside of a mains plug. Label the earth, live and neutral pins.

Guide to Condition Reports for Domestic Electrical Installations

Guide to sollysta Wiring Accessories

Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Oceanic Sauna Heater Manual

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Owner s Manual CPU-1QD CPU-1 CPU-1T CPU-2 CPU-2T HEAVY DUTY UPRIGHT VACUUMS. Save These Instructions

Read the other side, then complete the list below.

On/off button with booster (max) function* Fine filter Prefilter. Dust container Release button Charging indicator light. Vacuum cleaning cover

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Electrical Safety Policy

Update Note on the Disposal of Waste Electrical and Electronic Equipment (WEEE)

SHORT WAVE INFRARED PANEL DRYER

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

16 Ultiflame Inset Electric Fire

POLICY FOR THE SAFE WORKING WITH ELECTRICITY

Contact Details. Please note that some of the contact details on this PDF document may not be current.

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

Electrical Safety Requirements

The Facilities Manager s Guide to: Electrical Testing, Fire Alarms and Emergency Lighting Regulations. Updated May 2016

Turbo Circulating Fan (DC)

ELECTRICAL SAFETY for GAS ENGINEERS ACV. Do a GOOD JOB Take care of YOURSELF STAND OUT from the competition 2018 ISSUE 1. sterling4gas.co.

OPERATING INSTRUCTIONS

STEAM WALLPAPER STRIPPER MODEL HTW5

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

EH0554 Indoor Climate Control

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

MHG201 Gas Hob Manual for Installation, Use and Maintenance

Installation & Maintenance Guide

ASHDOWN STOVE SUITE

OPERATING INSTRUCTIONS

MOBILE PARTS WASHER MODEL No: CWM20

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

Glenmere Primary School Fire Safety Policy FIRE SAFETY POLICY. Revised on April Sam Conlon. Created by S.Conlon 1

TH100 Three in One Instant Hot Water Tap

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

Statutory Compliance Checklist

PAC1500Xi PORTABLE APPLIANCE CHECKER

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

8L Evaporative Cooler

Comment / Changes / Approval 0.1 Nov Draft Draft Policy

Well managed building mean risk is normal. Fire action notices should be displayed by all alarm break glass call points.

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

Girona. Operating Instructions. Glass Panel Heaters. Models: GFP050 W/B GFP075 W/B GFP100 W/B GFP150 W/B GFP200 W/B. A world of expertise

Fire Safety Policy Date: 0

EXTINGUISHER MAINTENANCE METHOD STATEMENT.

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

HS&S Alert No: 103 Date: 9 March 2017

Induction Cooker. Instruction manual. Model CM352-A

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Commercial Fan Heater

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

NFPA 70E Electrical Safety & Arc Flash Training

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

OPERATING INSTRUCTIONS

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Electrical Safety Policy

Imperial Electric Fires

Safety and Instruction Manual

Spa Control System OWNER S MANUAL

Where Process Safety meets Machine Safety

GETTING TO KNOW YOUR DRYER

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

MODELS HSCFH60WX, HSCFH90WX, HSCFH120WX

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

T550i power shower pump Installation and operating instructions

Installation & User Instructions:

Health & Safety Guidance

OPERATING INSTRUCTIONS

Transcription:

07/02/2011 Testing and Calibration Report for and on behalf of: Dr Jones Jones Surgery Newport Gwent NP20 2DX Your Next Test Date February 2012 Call: 01633 213366 Email:calibration@millermedicalsupplies.com

Test Results Summary Report Dr Jones Jones Surgery Newport Gwent NP20 2DX TestDate 22/02/2012 Product Count of Tests Baby Scales 1 Ear Syringe 1 Hyfrecator 1 Medical Pat Tests 1 I certify that the above test summary is an accurate record of work undertaken on 29/02/2012 Signed: (On behalf of Miller Medical Supplies Ltd) Name: (Print Name) Date:

Test Results Summary Report Dr Jones Jones Surgery Newport Gwent NP20 2DX TestDate 22/02/2012 Make Model Serial Number Calibration or Inspection? Pass/Fail Product: Baby Scales SOEHNLE CWB 7726 dfdfdf Calibration Product: Ear Syringe PROPULSE NG 65765765 Product: Hyfrecator Conmed Hyfrecator 2000 123456 Calibration Fail Fail Pass

Ear Syringe Fail Unit Details Customer Dr Jones TestDate 07/02/2011 Make and Model PROPULSE - NG Serial Number 65765765 Calibration or Inspection Test Results Test Description Result Unit Maximum Pressure Minimum Pressure Water Flow Rate Tip Leak Rate (over 15 seconds) Comments lkjlj 5 20 10 50 (High) Bar (maximum 3.45 Bar) (Low) Bar (minimum 0.27 Bar) ml/min. Drops General Visual Check n.a. Medical PAT Test Medical PAT Test Completed?

Baby Weighing Scales Fail Customer Dr Jones TestDate 22/02/2012 Unit Details Make and Model SOEHNLE - CWB 7726 Serial Number dfdfdf Calibration or Inspection Calibration Applied Weight Test Results Test Description Result Unit 5 kg KG 10 kg KG 15 kg KG 20 kg KG Comments General All feet in correct position Needle set at and returning to Needle straight Numbers easily identifiable Screen fitted securely Medical PAT Test Medical PAT Test Completed?

Hyfrecator Pass Customer Dr Jones TestDate 29/02/2012 Unit Details Make and Model Conmed - Hyfrecator 2000 Serial Number 123456 Calibration or Inspection Calibration Test Results Low Mode High Mode Bipolar Mode 1 Watt 1 Watts 5 Watts 5 Watts 3 Watts 3 Watts 3 Watts 3 Watts 10 Watts 10 Watts 5 Watts 5 Watts 5 Watts 5 Watts 20 Watts 20 Watts 15 Watts 15 Watts 35 Watts 35 Watts Comments All working as per normal, all documentation up to date. General Cable test on pencil pass Operational Foot Switch n.a. Cable test on bipolar forceps fail Working patient plate pass Checked pencil controls pass Medical PAT Test Medical PAT Test Completed? Yes

Guide To PAT Testing Below is a guide to Portable Appliance Testing as laid out in the Code of Practice for In- Service Inspection and Testing of Electrical Equipment compiled by the Institute of Electrical Engineers. Portable Appliance Testing has been developed as a convenient and complete method of testing electrical appliances to ensure that they are safe and with the correct maintenance schedule and test results ensures you to comply with your legal obligations. PAT testing is often seen as a process of "going through the motions" for some companies and often many companies fail to have it carried out at all. As a company we have tested many thousands of appliances and often attend premises to find appliances in dangerous conditions. The risks to employees, employers and businesses is very real, not only from the risk of electrical shock but also the risk of fire caused by faulty appliances. How many times do you read in the newspaper that a lifes have been lost or a home or business has been destroyed and that the cause was an electrical fault? PAT testing is an important part of any health & safety policy. Although there is no direct law at present stating that Portable Appliance Testing must be carried out you have a legal obligation under the following regulations to ensure that your electrical equipment is safe. Legal Requirements There are four main regulations which cover health and safety law The Health & Safety at Work Act 1974 puts the duty of care upon both the employer and the employee to ensure the safety of all persons using the work place. The Management of Health & Safety at Work Regulations 1999 state: "Every employer shall make suitable and sufficient assessment of: the risks to the health and safety of his employees to which they are exposed whilst at work" and to ensure the health and safety of persons not in his employment arising out of or in connection with the conduct by him or his undertaking." The Provision and Use of Work Equipment Regulations 1998 state: "Every employer shall ensure that work equipment is so constructed or adapted as to be suitable for which it is provided." PUWER 1998 covers most risks that can result from using work equipment. With respect to risks from electricity, compliance with the Electricity at Work Regulations 1989 is likely to achieve compliance with the PUWER 1998. PUWER 1998 only applies to work equipment used by employees at work. This includes all work equipment connected to a source of electrical energy. PUWER does not apply to fixed installations in a building such as the building internal wiring. The electrical safety of which is dealt with by the Electricity at Work Regulations. The Electricity at Work Regulations 1989 state: "As may be necessary to prevent danger, all (electrical) systems shall be maintained so as to prevent, so far as reasonably practicable, such danger." "'System' means an electrical system in which all the electrical equipment is, or may be, electrically connected to a common source of electrical energy and includes such source and such equipment". "'Electrical Equipment' includes anything used, intended to be used or installed for use, to

"'Electrical Equipment' includes anything used, intended to be used or installed for use, to generate, provide, transmit, transform, rectify, convert, conduct, distribute, control, store, measure or use electrical energy." Who should carry out the Testing? The IEE Code of Practice states, those carrying out the inspection and testing must be competent to undertake the inspection and, where appropriate, testing of electrical equipment and appliances having due regard of their own safety and that of others. The tester must have an understanding of the modes of electrical, mechanical or thermal damage to electrical equipment and appliances and their flexes which may be encountered in any environment. Training must include the identification of equipment and appliance types to determine the test procedures and be able to recommend the frequency of inspection and testing. Persons testing must be familiar with the test equipment used and in particular their limitations and restrictions so as to achieve repeatable results without damaging the appliance through testing. Types of Equipment Although the term used for testing is portable appliance testing it is not only your "portable" appliances which are required to be tested as laid out in the code of practice. The reason why PAT testing is carried out is to reduce the risk of danger from electrical shock and fire caused by faulty appliances. After all you have the same risk of receiving an electrical shock from a piece of equipment that is movable or static as you have a piece of portable equipment. The IEE Code of Practice gives guidance on the various equipment types. They then use this guide to suggest how often you should re-inspect equipment according to the type of business they are operating within. Portable appliance An appliance of less than 18kg in mass that is intended to be moved whilst in operation or an appliance which can easily be moved from one place to another, e.g. vacuum cleaner, toaster, food mixer, etc. Movable equipment This equipment is either: 18 kg or less in mass and not fixed, or Equipment with wheels, castors or other means to facilitate movement by the operator as required to perform its intended use. Hand Held equipment or appliances This is portable equipment intended to be held in the hand during normal use, e.g. hair dryer

soldering iron. Stationary equipment or appliances This equipment has a mass exceeding 18kg and is not provided with a carrying handle, e.g. refrigerator, washing machines. Fixed Equipment or appliances This equipment or an appliance which is fastened to a support or otherwise secured in a specific location many of these appliances are mainly fed from a hard wired cable directly into a fused spur unit, e.g. bathroom hand driers etc. Information technology equipment Information technology equipment includes electrical business equipment such as computers and mains powered telecommunications equipment, and other electronic equipment, such as printers, photocopiers, fax machines and monitors but to name a few. Frequency of Testing The Code of practice suggests testing frequencies based upon both the type of equipment, the class of equipment and the location or type of business in which the equipment is used. They have based their frequencies upon factors such as:- Environment - If equipment is installed in an environment where it may suffer damage such as on a construction site then the frequencies of testing would be more often than in an office for example where equipment is not subjected to the elements. Users - if the users report damage as and when it becomes evident, hazards will be avoided. Conversely, if equipment is likely to receive unreported abuse, more frequent inspection and testing is required Equipment construction - the safety of a Class 1 appliance is dependant upon a connection with earth of the electrical installation. If the flexible cable is damaged the connection with earth can be lost. Safety of Class 2 equipment is not dependent upon the fixed electrical installation as Class 2 equipment does not require an earth connection for the purpose of appliance safety. The equipment type - appliances which are hand held are more likely to be damaged than fixed appliances. If they are Class 1 the risk of danger is increased, as the safety is dependant upon the continuity of the protective conductor from the plug to the appliance. Testing Procedure In-Service testing involves: - Preliminary visual inspection - Earth continuity tests (for Class 1 equipment) - Insulation testing (Which may sometimes be substituted by touch current measurement) - Functional checks. Electrical testing should be performed by a person who is competent in the safe use of the test

Electrical testing should be performed by a person who is competent in the safe use of the test equipment and who is able to interpret the test results obtained. Visual Inspections Formal visual inspections should only be carried out by persons competent to do so. The results of the inspection must be recorded. The following must be considered when carrying out the inspection Suitability of the equipment for the use and environment The equipment should be assessed for its suitability for the environment or the nature of the work being undertaken. When the work environment is harsh or hazardous particular care needs to be taken when selecting the equipment and assessing the frequency of inspection and testing. Good Housekeeping A check should be made to ensure the equipment is installed and is being operated in accordance with the manufacturers instructions. Notwithstanding the manufacturers instructions, the following are examples of items which should be checked: (a) Cables located so as to prevent damage occurring. (b) Means of disconnection/isolation readily accessible (c) Adequate ventilation and cooling and that ventilation points are not obstructed. (d) Cups, plants and work material are placed correctly to prevent spillage (e) Equipment so positioned as to avoid strain on the cables or cords. (f) Equipment is being operated with the covers in place and any doors are closed (g) No Indiscriminate use of multi-way adaptors and trailing socket outlets. (h) No unprotected cables run under carpets Disconnection of equipment The means of isolation from the electricity supply must be readily accessible to the user, i.e. in normal circumstances it must be possible to reach the plug and socket without to much difficulty. The condition of the equipment Before inspecting equipment the users should be asked if they are aware of any faults and if the equipment works correctly. The following items need to be inspected: (a) The flexible cable (b) The socket outlet (if known), or flex outlet (c) The appliance - does it work and is it free from cracks or damage (d) The plug Some of the following checks may not be possible for equipment fitted with a non-rewirable plug Plug Top Checks

Plug Top Checks (a) Check detachable power cords to Class 1 equipment incorporates an earth cable (b) Check for signs of overheating (c) Internal inspection; cord anchorage, wired correctly, connections are tight (d) If non-rewirable plug; cord anchorage (e) Correct size fuse is fitted with British Standard or ASTA markings (f) Plug cover properly fitted (g) Check the flexible cable connections and anchorage at the equipment, if practica. Testing Procedure The electrical testing procedure should only ever take place after an appliance has successfully passed the visual inspection. All automatic Portable appliance testing equipment follows this procedure. - Earth bond continuity tests - Insulation resistance testing - Functional checks Earth Bond Test (Class 1 equipment only): Readings should be less than 0.1+R Ohms (where R is the resistance of the cable) Tested at a current of 1.5 times the rating of the fuse and no greater than 25A for a period of between 5 and 20 seconds or with a short-circuit test current within the range 20mA to 200mA. Insulation Resistance Test (may be substituted for the Touch current method) The applied test voltage recommended is 500 Vdc Class 1 heating equipment greater than 3kW 0.3M Ohms Class 1 All other equipment 1M Ohms Class 2 Equipment 2M Ohms Class 3 Equipment 250k Ohms Touch current method Class 1 Handheld Appliances 0.75mA Other Class 1 Appliances 3.5mA Class 2 Appliances 0.25mA Optional Tests: More advanced tester will carry out load/run tests and also download test results to a PC Operation / Load test The appliance is powered from the 240 v ac supply and a power consumption reading is taken from the appliance this is usually displayed in Watts or VA (Volt Amperes) and should be compared to the wattage rating stated upon the appliance label. Flash Test The flash test is no longer a requirement and is only recommended to be carried out upon repair of an appliance i.e. power tools.

Record Keeping Records of tests along with test results should be kept throughout the working life of an appliance. Without such records duty holders cannot be certain that the inspection and testing has actually been carried out. If an unfortunate incident should occur then records of test results could prove that you had done all "as far as is reasonably practical" in preventing danger. Records should include: A register of all Equipment A record of formal visual inspections and tests A repair register A register of faulty equipment Labelling On successful completion of tests an label should be attached to the appliance indicating: Appliance Number Whether the unit has passed or failed Test Date Next test due date Testers identity