AIRSYS-P-SC-TELECOOL-E1511V01.3 TELECOOL. Cabinet Cooling Unit. Cooling Capacity:500W-3000W

Similar documents
AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

Precision Air Conditioner For Critical Application

Chilled Water Precision Air Conditioner for Critical Application

AIRSYS-P-SC-MOBILECOOL-OUTDOOR-E1509V01.5 MOBILECOOL-OUTDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.5kW-13.

Liebert HIROSS for Telecom

Parts introduction FRONT BACK

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

DC Inverter Smart VRF Products(R410A)

LG VRF Systems. Air Conditioning Technologies

HERO SERIES-DC INVERTER HEAT PUMPS

Using the DewTrak II Dew Point/ Humidity Transmitter

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

GUCHEN THERMO TRANSPORT REFRIGERATION UNITS INTRODUCTION

New standard in compressed air treatment, providing Energy Savings up to 99%

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

Leak testing in the HVACR Industry

RIGID DC LIQUID CHILLER

Inverter Ducted Air Conditioners

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE. Master Rack Compressor Sequencer 7/21/2017

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

productdatasheet Compressed Air Refrigeration Dryer Efficient compressed air treatment Rev 01_0317 Page 1

DAIKIN Modular Inverter Air Cooled Chiller

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

Air Conditioning Systems

Technical Manual of Oceanair Refrigeration and Air-Conditioning Series Products. Product overview

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

Refrigeration dryers DW 2-504

Precision Cooling. DataMate3000 Series Precision Cooling Systems for Small Equipment Room IT Application

Guide Specifications

SUBCRITICAL & TRANSCRITICAL SYSTEMS

DAIKIN Huizhou Factory Profile

BURAN BURAN. Refrigeration Compressed Air Dryers for volume flows from 20 to 850 m³/h

Harold Ag & Mobile Products

Driven by CLIMATISATION. Excellence for professionals. Bosch air conditioning service units for R-134a and R-1234yf

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

190 PINT MANUAL # Pint 86 F 80%RH 115Pint 80 F 60%RH

ENCLOSURE COOLING. Glossary

Emerson Superheat Control. The smart solution for your application

The Refrigeration Cycle. Jerry Cohen President Jacco & Assoc.

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Boreas DV DV AVS / WVS Air cooled / water cooled Refrigeration Dryers

All DC Inverter Multi VRF

Hi-Pres Cooling Products Catalogue

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

ef cooling - FURRER Industriekühlung GmbH Technical Data Water Cooling Units EPI-A 2 - EPI-A 6 norden cooling

Air & Water Heat Pump R832

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

How To Make Lando Water Chillers? Leading the way of innovation. Here is the instruction to know more us how to

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

MAC-A R410A Series Air cooled Modular Chiller

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

15,000 BTU Portable Air Conditioner

EN aquatech.piovan.com

Refrigeration air dryer

Introduction of Panasonic CO2 refrigeration system. Panasonic Corporation Refrigeration and Air-Conditioning Devices Business Division

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Membrane Dryers KMM Series

Hi-Pres Cooling Products Catalogue. Product Catalogue

Pharmacy Refrigerator

Safe Enclosure Cooling

Industrial cooling systems LT

Implementation of Energy Saving measures in Existing Buildings

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

KONDRAIN KONDRAIN HP. Condensate Drains. Intelligent condensate drainage up to 350 bar. Rev 03_ EN

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Component Replacement Guidelines. For AIRSYS Wall Packaged Units. Models

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

DATASHEET CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC

MAC-D R410A Series Air-cooled Modular Chiller/Heat pump

Product Line Introduction. Karl Zhang Technical support engineer

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CONSTRUCTION AND OPERATION. 1. Air Conditioning Operation BE-95 BODY ELECTRICAL AIR CONDITIONING

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

CRV Variable Operation Refrigeration Dryers scfm

PRODUCT GUIDE

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner

PORTABLE AIR CONDITIONER

Quality Products. Service Excellence.

3 0 H X C A - H P 2

MOBILE AIR CONDITIONER. User Manual PC15/20/26-BCB

Refrigeration. User Instructions & Service History

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

OPERATING INSTRUCTIONS

LMF Rotary Screw Air Compressors kW LX Range

Climate Control Quick Reference

Development of compact air heat pump inverter module chiller Air heat pump chiller DT-R(4 units)

Biomedical Freezer 37 38

MODEL NUMBER: SRCOOL60KCW

Transcription:

AIRSYS-P-SC-TELECOOL-E1511V01.3 TELECOOL Cabinet Cooling Unit Cooling Capacity:500W-3000W

Brief Introduction TELECOOL cabinet cooling unit is cooling with compressor or heat pipe, and it will remove the heat inside the cabinet to outside. It can also keep the dust and heat outside the cabinet, avoiding problems from using fan. The inside cabinet can be maintained at an ideal temperature for electrical components which effectively guarantees the stability of the electronic equipment and improves the reliability of the whole system. The products can be widely used for outdoor communication cabinets, battery cabinets, electric cabinets, industry control cabinets etc. The default power source of TELECOOL is 48V DC, using the cabinet battery directly. The unit doesn t bear any additional failure risk and energy consumption caused by inverter, and continues working by using the electric energy from accumulator after the interruption of main supply, protecting the cabinet from shutting down due to the high temperature working environment. We provide multiple power sources for TELECOOL, the customer could choose suitable product according to their demands. Applications Battery Cabinet Outdoor Cabinet Telecommunication Base Station Nomenclature TELECOOL-AC. 50 C1 R134. DC4. 03. XXX Code for Custom Design: 3 alphabetic and numerical code Separator Character. Design Code 03: Design code for the third time 04: Design code for the forth time Separator Character. Power voltage DC4:48VDC(Standard) AC2:220VAC/1Ph/50Hz(60Hz) AD24:220VAC/1Ph/50Hz(60Hz) & 48VDC(not available for TLC-HP) Separator Character. Refrigerant: R134=R134a Cabinet Size Code: C1, C2, C3, C4. Cooling capacity Unit: W(TLC-AC Series & TLC-HY Series) Heat exchange Unit: W/K(TLC-HP Series & TLC-HY Series) Separator Character. Product series name: TELECOOL-HEATPIPE: Cabinet Heat Exchanger, it can be abbreviated as TLC-HP ; TELECOOL-AC: Cabinet Air Conditioner, it can be abbreviated as TLC-AC ; TELECOOL-HYBRID: Cabinet Air Conditioning Heat Exchanger, it can be abbreviated as TLC-HY. 02

TLC-HP Heat Exchanger Brief Introduction Heat exchanger is a device that utilizes the natural cool resource to exchange heat between hot inside and cool outside of cabinet with limited power consumption. When there is large temperature difference. The device will effectively exchange heat between hot inside and liquid refrigerant, between cool outside and gaseous refrigerant, bringing out heat through heat pipe, which make the cabinet to be an enclosed system with temperature control, and equipment inside can work normally. Product Features Unique Z shaped heat pipe structure, high heat exchange efficiency Without compressor, compact structure and light in weight, easy for installation and maintenance Parallel flow heat exchanger featured as short aisle, large fin space, making dust easy to pass. No need to install filter and maintain regularly Low startup temperature difference, making the most of natural cooling source Word-famous key components makes the system more stable Enclosed air circuit cooling system design, effectively avoid contamination from outside RS485 Communication port, monitor control 48V DC power supply standard, AC, AC&DC power supply are available on request Tested before leaving factory, performance and quality is assured Working Principle 1 6 5 2 4 7 3 8 1 Evaporator fan 2 Seporator 3 Condenser fan 4 Heat pipe 5 Air outlet for external circulation 6 Air inlet for internal circulation 7 Air inlet for external circulation 8 Air outlet for internal circulation 03

TLC-AC Air Conditioner Brief Introduction Comparing to the ones of traditional outdoor mobile base station without a temperature management device, the new battery of outdoor base station with a cooling unit has a service life prolonged 3 to 4 times. The newtype compression multi-functional cooling unit, which applies DC power supply, is able to ensure that the temperature of battery cabinet will not exceed 25 when the environmental temperature is as high as 55, and that its energy consumption only takes 1/4 of that of the traditional cabinet cooling unit. By advantage of the adaptation of 48V DC direct-driving compressor, the cooling unit doesn't need to bear any traditional failure risk and energy consumption caused by inverter, and continues working by using the electric energy from accumulator after the interruption of mains supply. Owing to the excellent energy efficiency ratio(eer), the working cooling unit only consumes a little of back-up power. For the regions where the mains supply is in a better and stable condition, we also provide a type of multi-functional cooling unit which applies the bi-model (AC & DC) power supply technologies. The compressor is AC-powered. When the mains supply is interrupted, the DC-powered fan and electric air valve will operate in time for indoor/ outdoor air exchange, so as to prevent the cabinet from excessive high temperature as a result of the interruption of mains supply. The electric air valve also has the function of exhausting hydrogen and acid gases produced by the working battery from the cabinet in daily use. The installation of multi-functional cooling unit not only can extend the service life of battery of outdoor station, but also prevent the station from paralysis as a result of battery failure. The multi-functional cooling unit not only can be used for the cooling of battery chamber, and also applies to the heat management of small outdoor cabinet due to its compact and light structure. Product Features Low noise mode, can be activated on site, meet special requirements Word-famous key components makes the system more stable Enclosed air circuit cooling system design, effectively avoid contamination from outside RS485 Communication port, monitor control 48V DC power supply standard, AC, AC&DC power supply are available on request Tested before leaving factory, performance and quality is assured Working Principle 4 1 7 2 8 1 Evaporator fan 9 3 6 5 10 2 Seporator 3 Condenser fan 4 Condenser 5 Evaporator 6 Compressor 7 Air outlet for external circulation 8 Air inlet for internal circulation 9 Air inlet for external circulation 10 Air outlet for internal circulation 04

TLC-HY Integrated Air Conditioning Heat Exchanger Unit Brief Introduction An ideal mini-shelter heat management equipment shall have low energy consumption as the heat exchanger but with the same cooling capacity as the cabinet airconditioning. Furthermore, when the cooling system malfunctions, the heat exchanger can operate automatically, so as to prevent the entire system of outdoor base station from "out of service" due to loss of temperature control. The innovative design integrates the compression cooling system and the independent flow heat exchanger, creating the "Integrated Air-conditioning Heat Exchanger", a brandnew heat management device which doesn't belong to cabinet air-conditioning and is different from ordinary heat exchanger. The outdoor base station works under changing temperatures. In general, the daily maximum temperature is in the time period from 10:00AM to 3:00PM. During such period, the compression cooling unit is used for cooling supply, while the heat exchanger is used to control the temperature during the rest periods. Therefore, under the same condition, the energy consumption of integrated air-conditioning heat exchanger is 70% lower than that of traditional cabinet air-conditioning. With an independent cooling and heat exchange system installed inside, the mini-shelter possesses two redundant sets of equipment even if merely one set in installed. Product Features Integrated with independent refrigerating system and heat exchanger Refrigerating system can work simultaneously and back up for each other, more stable Make the most of natural cooling source with intelligent step cooling Strongly recommend for energy saving projects Word-famous key components makes the system more stable Enclosed air circuit cooling system design, effectively avoid contamination from outside RS485 Communication port, monitor control 48V DC power supply standard, AC, AC&DC power supply are available on request Tested before leaving factory, performance and quality is assured Working Principle 4 5 1 9 10 2 1 Evaporator fan 11 3 8 6 7 12 2 Seporator 3 Condenser fan 4 Condenser 5 Outside heat exchanger 6 Inside heat exchanger 7 Evaporator 8 Compressor 9 Air outlet for external circulation 10 Air inlet for internal circulation 11 Air inlet for external circulation 12 Air outlet for internal circulation 05

Technical Parameters TLC-HP Heat Exchanger Model 80C2 120C3 180C4 Rated heat exchange W/K 80 120 180 Rated power input W 135 192 173 Power input -48V DC Working temperature -40~ +45 Color RAL7035 Refrigerant R134a Noise level db 65 Ambient air circuit m 3 /h 620 1130 1910 Cabinet air circuit m 3 /h 620 1130 1910 Unit dimensions and weight Width mm 497 567 646 Height mm 797 1007 1191 Depth mm 180 200 218 Weight kg 20 28 34 TLC-AC Air Conditioner Model 50C1 100C2 150C2 Cooling capacity(l35/l35) W 500 1000 1500 Rated power input W 200 440 550 Power supply -48V DC Working temperature -20~+55 Color RAL7035 Refrigerant R134a Noise level db 65 Ambient air circuit m 3 /h 360 420 420 Cabinet air circuit m 3 /h 255 420 420 Unit dimensions and weight Width mm 352 497 497 Height mm 583 797 797 Depth mm 173 180 180 Weight kg 16 26 28 TLC-HY Integrated Air Conditioning Heat Exchanger Unit Model 150C3 300C4 Cooling capacity(l35/l35) W 1500 3000 Rated power input W 550 970 Rated heat exchange W/K 80 120 Power supply -48V DC Working temperature -40~+60 Color RAL7035 Refrigerant R134a Noise level db 65 Protection grade Internal circuit IP34 External circuit IP55 Height Depth mm 507 600 Weight mm 947 1295 Depth mm 198 220 Weight kg 45 59 06

Unit Dimension Drawing C1 Cabinet Dimension Drawing 1 Inside air inlet 2 Power connection 3 Inside air outlet 4 Drain hose 5 Cutting area 6 Mounting hole C2 Cabinet Dimension Drawing 1 Drain hose 2 Outside air outlet 3 Outside air inlet 4 Panel locking hole 5 Cutting area 6 Mounting hole 07

C3 Cabinet Dimension Drawing 1 Outside air outlet 2 Outside air inlet 3 Drain hose 4 Cutting area 5 Mounting hole C4 Cabinet Dimension Drawing 1 Inside air inlet 2 The terminal 3-48VDC+alarm input power connection 4 RJ45 communication interface 5 Inside air outlet 6 Mounting flange 7 Drain hose 8 Cutting area 08

AIRSYS is a cooling product and solution provider for ICT (Information & Communication Technology) industry. The products include: Air conditioner and Chiller for IT room and large data center Intelligent Control system (BAS) for IT room and data center Air conditioning equipments for telecom shelters Intelligent control system for shelter cooling. Air conditioner and heat exchanger for telecom cabinets. The solution include: Cooling system design System integration Installation and Commissioning Operation and Maintenance AIRSYS is also a global leader in providing cooling solution for Medical Imaging System. AIRSYS Refrigeration Engineering Technology (Beijing) Co. Ltd. Add: No.28, LuGuDong Str., Shijingshan District, Beijing, China Post code: 100040 Tel:+86-10-6865 6161 Fax:+86-10-6865 2453 Callcenter :+86-400-820-5515 www.air-sys.com