TRV 300 RADIATOR VALVES

Similar documents
THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Halo. Thermostatic heads with built-in sensor

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

The new Terrier Belmont Thermostatic Radiator Valve range

Thermostatic Actuators

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Radiator Valve Program

RA2000 Thermostatic Radiator Valves

TA-MATIC

Data sheet Thermostatic sensors type RA 2000

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Form 4: Integrated Science Notes TOPIC: TEMPERATURE CONTROL AND VENTILATION TEMPERATURE CONTROL: HEAT TRANSFER

We have replacements! Introducing the NEW Macon Controls EVO, VAO/VAC and EVO-Z

TS RD 7761 RD, 7761 RD

Section - A. Radiator Valves

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Heating Controls Thermostatic and Manual Radiator Valve range

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

Heating Technology sinc e

caleffi hydronic valves page 1 of 12

RT021 User and Installation Instructions

SOLUTIONS GUIDE. For total efficiency

IMI Heimeier Kit Hydroca ble

INSTALLATION AND MAINTENANCE MANUAL. Alcor FA

ST Wiring diagram. Product description. Standard temperature controller. Order number

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

Thermostatic head with wax sensor

Convertible radiator valve for one-pipe systems, centre distance 35 mm

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Installation and operating instructions

Frost Protection Thermostat

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

STRAIGHT AND ANGLED THERMOSTATIC VALVES

DEVIATING VALVES ART K063

T4398A,B Precision Electric Heating Thermostat

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.

The heart of electric appliances ELECTRIC WATER HEATING MADE IN ITALY

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Instruction FH-CWP Thermostat

Dear Customer. Contents. 1) Vantage Electric Radiator characteristics Pag.3. 2) Technical specifications Pag.3. 3) Warnings Pag.4

Thermostatic valves with radiator connection systems

Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet

OIL FILLED RADIATOR Instruction manual

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

Heating controller with optimisation functions

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Operating instructions Oil condensing boiler

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Flush individual room control for floor heating systems

Automatic balancing valves ASV-PV (new generation) DN 32-50

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Programmable Towel Radiator Manual

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

T5000 LCD Digital Fan Coil Thermostat

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

HYDROTHERM H - SERIES TOWEL RAIL H4 Model

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

CROMO manual mixer shower

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

RVA /109. Heating Circuit ZONE Controller. Instructions for the INSTALLER

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Waterbaths & Oilbaths

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

living connect, Electronic Radiator Thermostat

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Overview Frost Heave Prevention for Freezer floors on ground.

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

Installer Manual KNX Touchscreen Thermostat

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

TA-SCOPE. Balancing instrument ENGINEERING ADVANTAGE

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4.

Frost Units for air temperature monitoring

USER MANUAL AND TECHNICAL MANUAL

Raychem Heating System

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Dear Customer, We wish that this product, manufactured at modern facilities with total quality notions, will deliver you the best performance.

Rotameter series 250 metal tube variable area flowmeter

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Transcription:

RADIATOR VALVES THERMOSTATIC HEADS Placed on radiator valves, these self-acting thermostatic heads for adjusting temperature are reliable, accurate, and long-lasting. LIQUID FILLED SENSOR ELEMENT For higher closing power, reduced maintenance costs and trouble-free operation. REMOTE SENSOR OPTION For total accuracy. TEMPERATURE LIMITATION Set maximum and minimum temperatures, helping to reduce running costs.

TECHNICAL DESCRIPTION Application: Heating systems Functions: Regulating Shut-off Maximum and minimum restriction Nominal temperature range: See each product Temperature: Max. ambient temperature: 50 C Min. ambient temperature: -25 C Stroke: 0.22 mm/k Heat transfer from inlet water: Thermostatic head with integral sensor and thermostatic head with remote setting: 0.4K Thermostatic head with remote sensor: 0.3K Replacement thermostatic head M28x1,5: 0.8K Time to close: Thermostatic head with integral sensor 24 min Thermostatic head with remote sensor: Horizontally fitted sensor 12 min Vertically fitted sensor 15 min Hysteresis: 0.2K Materials: Plastic parts of ABS, acetal and nylon. Sensor element contains ethyl acetate liquid. Colour: White Marking: Thermostats are marked with TA and, where applicable, with the CEN symbol. 2

50 340-028 6-28 C With locking ring 50 341-028 6-28 C With two locking screws Allen key 2 mm 50 343-028 6-28 C Protective model 50 370-026 8-26 C 3

THERMOSTATIC HEAD WITH REMOTE SENSOR Capillary tube length 50 340-127 6-27 C 1,25 m 50 340-227 6-27 C 2 m 50 340-527 6-27 C 5 m 50 340-827 6-27 C 8 m With locking ring Capillary tube length 50 341-227 6-27 C 2 m With two locking screws Allen key 2 mm Capillary tube length 50 343-227 6-27 C 2 m To install the capillary tube in electric installation tube. Note: Tube without bends; use minimum 25 mm diameter. Tube with bends; use minimum 32 mm diameter. THERMOSTATIC HEAD WITH REMOTE SETTING Capillary tube length 50 380-227 8-27 C 2 m 50 380-527 8-27 C 5 m 50 380-827 8-27 C 8 m 4

THERMOSTATIC HEAD WITH REMOTE SETTING AND REMOTE SENSOR Capillary tube length 50 382-227 8-27 C 2 m x 1,5 m To install the capillary tube in electric installation tube. Note: Tube without bends; use minimum 25 mm diameter. Tube with bends; use minimum 32 mm diameter. THERMOSTATIC HEAD WITH REMOTE SENSOR FOR POCKET TUBE OR HEAT TRANSFER CRADLE Pocket tube and heat transfer cradle - see Accessories. Capillary tube length 50 364-201 20-50 C 2 m 50 364-202 40-70 C 2 m REPLACEMENT THERMOSTATIC HEAD M28 Ø48 80 50 310-028 6-28 C M28 HANDWHEEL 50 399-003 5

ACCESSORIES Setting key For thermostatic head, protective model 50 370-001 Locking ring For thermostatic head with integral/remote sensor 50 350-006 Key regulator 4 mm allen key 50 399-006 Adapter M28-M30 50 357-530 Restriction pin For thermostatic head with intergral/remote sensor 50 340-001 6

Pocket tube for remote sensor For thermostatic head 50 364-201/-202 50 364-200 186 G1/2 Heat transfer cradle for remote sensor For thermostatic head 50 364-201/202 50 364-203 FUNCTION TRV 300 When the ambient temperature rises above the set value of the thermostat, the fluid in the sensor expands and starts to close the valve. When the ambient temperature falls below the thermostat s set value, the fluid in the sensor contracts and the return spring in the valve starts to open the valve. When set to the frost protection position ( ), the valve opens at a temperature of about 6 C in order to prevent the heating system from freezing. NB: If the TRV 300 with integral sensor is fitted vertically to a valve, with the sensor upwards, it may be affected by the heat from the pipe below and therefore close too early. In such cases, a thermostatic unit with a remote sensor should be used, with the sensor placed immediately beneath the radiator if possible or, if not, in the centre of the room. The scale on the thermostat represents a temperature change of 4 C between each numeral. Each mark on the scale represents a 1 C change. Thermostatic head with remote sensor for pocket tube or heat transfer cradle When the water temperature rises above the thermostat s set value, the thermostat start to close the valve. When the water temperature falls below the set value, the return spring in the valve start to open the valve. 7

MAXIMUM TEMPERATURE RESTRICTION Set the index opposite to the maximum room temperature required. E.g. number 3 corresponding to 20 C room temperature. 1. Put the restriction pin in a little way opposite to number 5 to mark the correct pin position. Close the thermostat a little by turning it clockwise. 2. Fully insert the restriction pin. 3. Open the thermostat by turning it anti-clockwise and check that the index stops at a position corresponding to desired room temperature. NOMINAL TEMPERATURE RANGE The specified temperatures apply at the nominal lift height in accordance with CEN. Under normal operating conditions, the set temperature will be maintained with a maximum deviation of ±1K. SETTING SCALES The closing temperature is normally 2K higher than ambient temperature. Thermostatic head with integral sensor / remote sensor The various settings give approximately the following room temperatures: Thermostatic head, protective model The various settings give approximately the following room temperatures: Thermostatic head with remote setting / remote setting and remote sensor The various settings give approximately the following room temperatures: Thermostatic head with remote sensor for pocket tube or heat transfer cradle The settings produce approximately the water temperatures shown on the thermostatic head. Tour & Andersson retains the right to make changes to its products and specifications without prior notice. 1-10-5 TRV 300 2008.05 8