We know what it takes...

Similar documents
Senscient s team has more than 150 years collective experience in gas. detection.

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

FIRE & SAFETY SPRING 2016 EDITION

GASSONIC Ultrasonic Gas Leak Detection. How fast does your Gas Detection System detect leaks? Because every life has a purpose...

MSA Flame & Gas Mapping

Gas Detection in Process Industry The Practical Approach

Using CFD to Analyze Gas Detector Placement in Process Facilities

Dräger Catalytic Ex-Sensors DrägerSensors

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

International Journal of Advance Engineering and Research Development

Laser-based gas detection technology and dispersion modeling used to eliminate false alarms and improve safety performance on Terra Nova FPSO

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Fixed Gas & Flame Detection International Product Range Overview

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Aspirating Gas Detection CFD Modelling Predicts Application Performance

Dräger PIR 3000 Detection of flammable gases and vapours

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

FM Approved Fire & Gas Detection System

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Flame 5000 Flame Detection

Application Bulletin. LNG / LPG Facilities FLAME AND GAS DETECTION FOR LNG FACILITIES

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

TOXIC AND FLAMMABLE GAS CLOUD DETECTORS LAYOUT OPTIMIZATION USING CFD

MSA XCell Sensors. Because every life has a purpose

CCTV, HOW DOES IT WORK?

Portable Instrument Application Guide

Dräger Flame 5000 Flame Detection

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Safe Operation Manual. Honeywell IQ Force Gas Detector

Firefighter Safety in Battery Energy Storage System Fires

Datalogging as standard

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

HFID Heated Total Hydrocarbon Analyzer Module

Fire Alarm Intelligibility. Chris Nolan

Protecting Ethylene Process Facilities: A Review of Gas Detection Methods

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

BP Alaska GC-1. Design Review Project. January 2003

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

Dräger X-am 5000 Multi-Gas Detection

APN0064.P65 Issue 01-06/2000 COMPARISON OF OPTICAL DETECTION SYSTEMS FOR INFRARED HYDROCARBON GAS DETECTION

intrinsically safe detector for hydrocarbon gases

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Application Note. Gas Turbines. Introduction. Market Segments

FIXED GAS DETECTORS PDF

Thank You for Attending Our February Webinar:

Aspirating Smoke Detection for Duct Monitoring

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters

T.ex Single Gas Detector VISA

Training Authorised Gas Tester Level 1. Basic Information

Thermo Scientific TVA2020 Introduction

Dräger Flame 2100 Flame Detection

ALTAIR 5X Multigas Detector

ULTIMA X5000. MSAX5000.com

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

IFD-E Flame Detector User Manual

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Guidance on Video Smoke Detection Technology (VSD)

Standoff CWA/TIC Detection. Innovation with Integrity. Toxic Gas/Vapour Threat Mitigation RAPIDplus CBRNE

CALIDUS tm the Modular micro Gas Chromatograph

Personal Protection Systems (PPS)

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

GAS DETECTOR LOCATION. Ø.Strøm and J.R. Bakke, GexCon AS, Norway

IFD-E Flame Detector User Manual

Ex Products Highest level of safety under the most difficult conditions

MicroRay IR-100 NEW. Inspection MicroRay IR-100

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

Model D12-IR. Digital Gas Transmitter...

Dräger X-am 2500 Multi-Gas Detection

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Procedure for the Approval of New Fire Detection and Alarm Technologies

Dräger QuadGard Control System

Hydrocarbon Gas Detector

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

CHAPTER 1 INTRODUCTION

Water Spray Systems: NFPA 15

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

MSA Portable Gas Detection

Ultrasonic Gas Leak Detection

Sensor Placement Algorithm for Rapid Theatre Assessment (SPARTA)

Selecting Gas Detectors for Confined Space Entries

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

ALTAIR 5X Multigas Detector

Outages Happen 24/7. So Should Monitoring. / PREVENT POWER TRANSFORMER FAILURE WITH HELP FROM VAISALA

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Bringing Smarts to Methane Emissions Detection

Properly calibrating catalytic bead sensors: A practical guide

Operating Instructions and Maintenance Manual

testo 316-EX gas leak detector Instruction manual

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Xi Advanced Electronics for Zirconium Oxide Oxygen Probes

Chapter 17, Initiating Devices

LP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2

Case Study. Selecting fire and gas detectors for harsh and remote locations. INSTRUMENTATION

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Dräger GS01 (wireless) Detection of flammable gases and vapours

Nanotechnology-Based Gas Sensors

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Transcription:

We know what it takes... 2017-2018 Gas Detection Seminars Practicable approaches to mitigate risks from flammable and toxic gas releases... with CAPEX and OPEX considerations. The ability of the gas detection system to detect gas releases reliably and quickly is crucial for the mitigation of flammable gas explosion risks or toxic gas poisoning risks. Deciding detector placements for good detection coverage that will ensure fast alarming of gas releases is therefore a critical task for the gas detection system engineer. This task is significantly more difficult when the area to be monitored is an open space that is subjected to changes of wind speed and direction. Having to balance between risk mitigation and cost considerations further complicates this task. This series of seminars will present how some of MSA s leading gas and flame detection technologies can help improve detection coverage for faster alarming and faster execution of other risk mitigation actions; practicably with a low cost of ownership. Seminar speaker: Edwin Choo The speaker has a Bachelor s Degree in Electrical & Electronics Engineering from the National University of Singapore and is a Certified Functional Safety Professional. He has 25 years of professional experience in Fire & Gas System solutions design and implementation, and is presently MSA s Detection Product Group Manager, Pacific Asia Region. www.msasafety.com/detection

Seminar 1: A method to improve the likelihood and speed of detecting dangerous natural gas releases for fast gas detection alarming Natural gas typically contains a high percentage of methane (CH 4 ) gas plus a few other hydrocarbon gases, usually in significantly smaller amounts. Depending on where it is extracted from, natural gas can also contain small amounts of carbon dioxide (CO 2 ) and hydrogen sulfide (H 2 S), in which case the gas is termed sour natural gas. With the aid of gas dispersion modeling, this seminar will illustrate how a high sensitivity ELDS TM OPGD (Measuring range: 0-1000ppm.m, 0-1LEL.m) can significantly improve the likelihood and speed of detecting flammable natural gas releases in windy open spaces... by measuring CH 4 at lower concentrations. The use of the ELDS TM OPGD as an alternative solution for detecting highly toxic H 2 S in open spaces will also be presented; to show that this solution can produce a very high degree of detection coverage at a significantly lower cost of ownership. Other topics that will be covered in this seminar: How ELDS Harmonic Fingerprinting guarantees no false alarming, even at low concentration measurements. How the ELDS measurement accuracy is maintained by the Harmonic Fingerprint Lock technique. How the ELDS safety functions are checked daily to maintain high system safety integrity. Duration: 120 minutes.

Seminar 2: Detecting gas releases in high wind open spaces reliably and quickly by measuring the ultrasonic sound pressure level (SPL) of leaks with an intelligent UGLD A change in wind direction can alter the dispersion path of the released gas; moving it away from the stationary gas detector. This can render the gas detection system ineffective and allow the gas release to continue for a longer period, thus multiplying the risk factor. Wind can also dilute the gas plume to such an extent that the gas concentration falls below the minimum measuring sensitivity of the gas detector; at the location of the detector. Closer to the release point, the released gas concentration will be at a significantly higher concentration. This seminar discusses how the Ultrasonic Gas Leak Detector (UGLD) can be a very effective solution for detecting high pressure gas releases very shortly after it occurs, even in high wind open spaces. A well designed spread of the UGLD can result in very high gas detection coverage without a large quantity of conventional gas detectors. Consequently, the costs of implementation and maintenance will be very low. The discussion will cover: Factors that influence and limit the performance of the UGLD. How the placement of a UGLD can be field tested for confirmation of detection coverage; to validate engineering design. How multiple UGLD units can be used together to determine the possible location of the gas release point. Duration: 60 minutes

Seminar 3: Using gas dispersion modeling and gas mapping to position point type gas detectors more effectively in open spaces All point detectors measure gas concentration only when it comes into contact with the gas. Detector placement is therefore a crucial engineering task. The general rules of thumb for placing point type gas detectors that are often quoted are; 1) Place gas detectors near potential points of gas release; 2) Place gas detectors within zones of potential gas accumulation. In practice, this guidance is often too simplistic to be truly useful to the gas detection system engineer, especially when the monitored area is outdoors where wind factors can affect gas dispersion, and when there are multiple potential points of gas release for the engineer to deal with. Further compounding the problem are factors such as source terms of release, ambient pressure and temperature, wind stability, composition of gas, height of release, direction of release, impingement, roughness of terrain, area confinement and obstructions. Gas dispersion modeling and gas mapping tools are often used to compute all these factors in aid of this design process. The ultimate aim is to quantify and position detectors for best coverage. Depending on the degree of conservativeness, gas dispersion modeling and gas mapping can result in a larger number of detectors than first anticipated, for the desired detection coverage. Rationalizing detector quantity to balance between cost and coverage can be difficult. Using worked examples the seminar will discuss and illustrate: Key factors that influence gas dispersion. Gas detection coverage and how it matters in risk assessment. How the dual sensor feature of the S5000 and X5000 detectors can help reduce the total cost of implementation, without sacrificing the desired detection coverage. How XCell sensors with TruCal features can reduce the need for detector maintenance and significantly lower total cost of ownership, without affecting system safety integrity. Duration: 90 minutes

Seminar 4: Using flame mapping to place, orientate and angle flame detectors for more effective detection coverage The ability of a protection system to suppress fires and execute other protective actions before more severe consequences occur is highly dependent on the system s ability to detect the fire reliably and quickly. One measure of ability is detection coverage. A high degree of detection coverage usually means a higher ability to react effectively. In flame detection systems, the choice of sensing technology, the design of detector optics, detector positioning, detector mounting height, rotation orientation and declination angles are key factors that can affect the degree of detection coverage. Flame mapping is a software simulation process that is now widely applied to assess detection coverage. Except for sensing technology and optics design, all other parameters used in flame mapping are installation related. For the simulated detection coverage to be realized, the installation parameters used in the flame mapping exercise must be physically applied to the detectors. Quite often, it is found that rotational and declination angle adjustments of flame detectors after mounting on site are done poorly or not at all. The result is poor detection coverage; which unfortunately may remain unknown until there is an actual fire. The seminar discusses and illustrates: How flame mapping is used to determine detector placement, for optimum deployment quantity Factors that influence flame detection coverage Applying the flame mapping parameters in the real world Duration: 60 minutes

MSA S.E. Asia Pte Ltd 35 Marsiling Industrial Estate Road 3, Unit #04-01 Singapore 739257 Office main line: +65 6350 4500