IES PREPARATION COURSE FOR PPE PART2 EXAM ELECTRICAL ENGINEERING CP5 on Wiring Regulations and Low Voltage Design Calculations

Similar documents
ABC WATERS PROFESSIONAL COURSES Elective Module EU 5

ABC WATERS PROFESSIONALS COURSES CORE MODULE CU 4

AN INSIGHT TO SINGAPORE S ABC WATERS MANAGEMENT STRATEGY

Contents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671

For Registration or any Inquiries. Date: November 2017 (3-Day) Time: 8:00 am - 4:00 pm Venue: Manama, Kingdom of Bahrain

The extent of liability of the signatory/signatories is limited to the work described above as the subject of this certificate.

ER 52 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) EA 147M(c)(i) (1 mark) EA 147M(c)(ii)

Guide to: 17 th Edition Consumer Units

An overview of the main proposals in BS th Edition. Electrical Contractors Association

NATURAL GAS 1 DAY ANGVA WORKSHOP ON. WORKSHOP 20 May for VEHICLES, YANGON, MYANMAR

Laser Safety Forum. 10 September followed by. Laser Safety Refresher Course 11 September 2013

BS Outcomes 6

ABC Waters Professionals and Practitioners Networking Night

Master Gardener Volunteer Expectations Guidelines

INTERNATIONAL STANDARD

DCP3/ DETAILS OF THE CLIENT ADDRESS OF THE INSTALLATION

(date) except for the departures, if any, detailed as follows: Name (CAPITALS) N/A. Name (CAPITALS) N/A

INTERNATIONAL STANDARD

Date of Start and downloading the tender 12 sep 2018

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

Sponsor Irrigation Association Classes in Your Area

Requirements for Electrical Installations

Project Briefing Document. Section 3 Electrical Services design guide and specifications

REBATE. Ductless Mini-Split Heat Pump

Guide to Condition Reports for Domestic Electrical Installations

clipboarddesigns INTERIOR DESIGN HOME STYLING ONLINE

ELECTRICAL INSTALLATION PERMIT HOMEOWNER

Subject Description Form

Advokatfirmaet BAHR AS - ENGAGEMENT TERMS

CUMULATIVE (ENVIRONMENTAL) IMPACT ASSESSMENT

ABC Waters Project at Potong Pasir A Case Study

MASTERCLASS IN CUMULATIVE (ENVIRONMENTAL) IMPACT ASSESSMENT

DIPLOMA IN DIPL INTERIOR DESIGN

THE LAWN AND GARDEN SHOW

ELECTRONIC SECURITY THEORY/REGULATIONS EXAMINATION 19 November 2011

Replacing a consumer unit in domestic premises where lighting circuits have no protective conductor

Level 3 Certificate in Fire Safety Fire Auditors Xact Consultancy and Training Limited

NZQA registered unit standard version 1 Page 1 of 5

IFE-NFPA WORKSHOPS. Jointly organized by The Institution - of Fire Engineers, Singapore Branch & National Fire Protection Association, USA

Presented by: The Electrical Association of Philadelphia 527 Plymouth Road, Suite 408 Plymouth Meeting, PA (610)

Application for Up-Grade Approved Electrician

Neil Hewitt Electrical & Air Conditioning P/L

Application for the Issue of Initial SJIB Grade (ECS) Card

Massachusetts COOL SMART

IFLA Guidelines for Satellite Meetings. Approved by the IFLA Professional Committee and the IFLA Governing Board August 2012

Dear Volunteer Master Gardener Applicant for the Sutter-Yuba Counties, U.C. Master Gardener Program

Initial Application for an Electrical Fitter (ECITB) SJIB Grade (ECS) Card

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

Initial Application for Emergency & Security Systems Operatives SJIB Grade (ECS) Card

Level 4 Certificate in Fire Safety Fire Auditors Xact Consultancy and Training Limited

INTERNATIONAL STANDARD

Level 5 Fire Engineering Design. Courses and qualification

INTERNATIONAL STANDARD

Plumbing, Heating & Gas Industry Course Information

SUMET09 Maintain electrical systems and equipment (SQA Unit Code- H956 04)

RIAI URBAN DESIGN SEMINAR & WORKSHOP SERIES 2010

At least 10 calendar days prior to project start date Within the last 30 days of a project that will extend beyond 12 months

Membership Application

Exemptions Interprofessional practice: Architects and engineers are exempt for work which is incidental to their practice.

ABC Waters Professionals and Practitioners Networking Night

IFE: Level 5 Diploma in Fire Engineering Design Xact Consultancy and Training Limited

Rain garden and native planting area registration forms

INTRODUCTION TO ENVIRONMENTAL IMPACT ASSESSMENT (EIA)

2013 season ticket for CPD events

3 o/c2 The symbol used to show that a BS 88 device has a motor circuit application is a gg b gm c l z d I 2.

Initial Application for Fire Detection & Alarm Systems Operatives SJIB Grade (ECS) Card

Adopt-A-Community Garden Agreement

Victorian Solar Hot Water Rebate Guidelines for Applicants and Suppliers (Updated 4 September 2009)

Terms of Reference for the appointment of a Public Relations Service Provider for events at the Kirstenbosch National Botanical Garden (KNBG),

Guide to condition reports for domestic electrical installations.

Buying goods/services

Writer member application

PIKES PEAK REGIONAL BUILDING DEPARTMENT Fire Alarm Contractor License Application

Contact Details. Please note that some of the contact details on this PDF document may not be current.

2018 Membership Application

CORRIGENDUM NO: 2 TO REQUEST FOR QUOTATION CRFQ NO E-Tender Ref. No: 9093

INTERNATIONAL STANDARD

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

FTTN Business Readiness Testing Special Terms

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

IFLA Regional Office for Latin America and the Caribbean: Call for Applications to host the Regional Office

COMMUNITY GARDEN BYLAWS

2019 Landscape Awards

Developer, new connection and infrastructure charges

Initial Application for ECS Related Discipline Card

INTERNATIONAL STANDARD

Fire Sprinkler Courses

Contract for Hire Kaikohe Memorial Hall Memorial Avenue Kaikohe

Membership Application

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

Multifamily Energy Efficiency Rebates Application Package

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

FOR SALE RESIDENTIAL DEVELOPMENT OPPORTUNITY BLAIRTUMMOCK EASTERHOUSE

INTERNATIONAL STANDARD

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

SMALL WORKS PROJECT REQUEST FOR SEALED BIDS

Periodic inspection reporting - recommendation codes for domestic and similar electrical installations

Exhibition Application and Guidelines -Urbanspace Gallery-

Consumer unit replacement in domestic and similar premises

ELECTRIC FIRE PUMP CONTROLLER

Transcription:

IES PREPARATION COURSE FOR PPE PART2 EXAM ELECTRICAL ENGINEERING CP5 on Wiring Regulations and Low Voltage Design Calculations PROGRAMME DETAILS Date Duration Time Venue Fees * : 27 & 28 March 2018 (Tuesday & Wednesday) : 8 Hours : 9am 6pm : IES Academy @ Jurong East (Devan Nair Institute, E2i Building) 80, Jurong East Street 21 #04-10, Singapore 609607 (Near Jurong East MRT) : $695.50 (IES Member), $909.50 (Non-Member) Inclusive of 7% GST and course materials.. Certificate of Attendance will be given to participants with 100% attendance Day 1: Code of Practice for Electrical Installation CP5 Wiring Regulations (Made Easy to Understand with Explanations for Design) INTRODUCTION My many years of Professional activities and social interaction talking to a number of Professional Electrical Engineers and old and young Electrical Engineers from the consulting, electrical installation and contracting industry, as well as Plant Electrical Engineers from the manufacturing sectors, I gained the strong impression that there was one need which had not really been fulfilled and satisfied. This was the need to conduct a comprehensive training course on the Code of Practice for Electrical Installation CP5 for all interested parties involved in the electrical industry. OBJECTIVES The code of practice for electrical installation CP5 applies to the design, selection, erection, testing and inspection of electrical installations. It covers all general commercial and industrial electrical installations operating at voltage up to 1000 Volts. Its main objective is to provide safety from fire, shocks and burns. There are a total of seven parts which make up the Code - CP5: Part 1 Scope, objective and fundamental requirements for safety Part 2 Definitions of terms used in the Code- CP5 Part 3 Assessment of general characteristics Part 4 Protection for safety Part 5 Selection and Erection of equipment Part 6 Special installation or locations Part 7 Inspection and Testing and Seven (7) Appendices The course aims to provide participants with a thorough knowledge and understanding of the Code of Practice with explanations backed by basic electrical engineering theory why certain regulations are written and worded in a way seen less obvious for the average person. Note Participants taking this course must bring their own copy of the Code of Practice CP5.

COURSE OUTLINE The topics to be discussed in each parts of the Code of Practice will include but not limited to the following: Part 1 Scope, objective and effects and fundamental requirements for safety Inclusions and Exclusions from the scope Objective and Effects In Contractual Agreement Relationship with Statutory Authority Licensing of Electrical Installations Workmanship and Materials Equipment Conductors Overcurrent Protective Devices Protection against earth leakage and earth fault Fundamental safety requirement Part 2 Definitions Suggest for self reading Part 3 Assessment of general characteristics Purpose, Supplies and Structure Arrangement of Live Conductors Type of Earthing Earthing arrangement used in Singapore Prospective short-circuit current External Earth Fault Loop Impedance Part 4 Protection for Safety Protection against Electrical Shock Temperature Effect on (Z s ) under earth fault conditions Protection against both Direct and Indirect Contact General requirement for EEBADS Purpose of Providing Equipotential Bonding Equipotential Zone Inside and Outside of Equipotential Zone EEBADS for TN-S System Protection against Indirect Contact on TN-S System Circuits with Difference disconnection times emanating from a common distribution board EEBADS for TT-System EEBADS Supplementary equipotential Bonding Protections against thermal effects Protections against overcurrent Overload Current and Fault Current Nature of Protective Devices Protection against both overload and fault current Co-ordination between conductor and protective devices Determination of Prospective Fault Current Short Circuit Calculations Phase to Neutral Short Circuit Phase to Phase Short Circuit Three Phase Short Circuit Phase to Earth Short Circuit Fault Current at the origin of an installation Characteristics of a Fault Protective device Isolation and Switching Protection according to the nature of the circuit and distribution systems

Part 5 Selection and Erection of equipment Method of installation of cables and current-carrying capacity of cables Conductor operating temperature Determine the size of cable to be used Grouping factor and application of grouping factor Ambient temperature Derating factor Application of Ambient temperature factor Thermal Insulation Derating factor and its applications The general rules When Protective Device is not a Semi- Enclosed or Rewireable Fuse Circuits subject to simultaneous overload Circuit not subject to simultaneous overload Voltage drop in consumers installation Voltage drop calculation Part 6 Special installation or Location particular requirements Bath Tub/ Shower Basin Swimming Pools Hot air Sauna Part 7 Inspection and Testing Day 2: Low Voltage Electrical Installation design calculations for compliance with Code of Practice for Electrical Installation CP5 INTRODUCTION The first stage in designing an electrical installation system after having carried out the assessment of general characteristics demanded in part 3of CP5 and the determination of the design current, is the choice of the type of cable and the method of installation of that cable for such circuit. Where there are a number of options open to the installation designer from purely technical considerations, the final choice will depend on the commercial aspects or designer s or clients personal preference. To determine the minimum conductor cross-sectional area of the live conductors of a particular circuit, the designer must take into consideration circuits in varying external influences and installation conditions, such as circuits in thermal insulation walls, circuits totally surrounded by thermal insulating material or circuits in ventilated trenches or on perforated metal cable trays or in enclosed trenches or in enclosed metal trunkings or in metal conduits. Also, the designer must decide at some stage, whether the circuit is to be run singly or bunched or grouped with other circuits. He must also decide whether it is intended the overcurrent protective device is to give: (a) Overload Protection only, or (b) Short Circuit Protection only, or (c) Overload and Short Circuit Protection (d) Establish the maximum voltage drop (e) Estimate the route length of the circuit It cannot be emphasised too strongly that unless all the foregoing items are available, it is not possible to design any circuit.

OBJECTIVES The course aims to provide participants with practical skills backed by theoretical knowledge on how to: Calculate the cross-sectional areas of live conductors for compliance with Regulation 523-01-01, namely that under normal load conditions that maximum permitted normal operating temperature is not exceeded. Calculate the earth fault loop impedance for compliance with the requirement concerning maximum disconnection time of protective device being used for protection against indirect contact. Calculate the circuit protective conductor cross-sectional areas for compliance with Regulation 543-01-01. Calculate the short circuit current at the origin of an installation and elsewhere These are broadly speaking topics demanded in the syllabus of the PPE examination part 2. Note Participants taking this course must bring their own copy of the Code of Practice CP5 and Calculator. COURSE OUTLINE (A) Calculation for the determination of the cross-sectional areas of circuit live conductors. Topics and calculation examples covered under this section will include but not limited to: General Circuits Circuits in thermally insulated walls Circuits totally surrounded by thermally insulating materials Circuits in varying external influences and installation conditions Circuits in ventilated trenches Circuits on perforated metal cable trays Circuits in enclosed trenches Circuits in enclosed metal trunkings and in metal conduits Circuits in low temperatures Motor circuits subject to frequent stopping and starting Circuits for Star-Delta Starting of motors (B) Calculation of Voltage drop under normal load conditions. Topics will include but not limited to: Using the simple approach Using the more accurate approach taking account of the load power factor Using the more accurate approach taking account of both conductor operating temperature and load power factor Voltage drop in Ring Circuits (C) Calculation of Earth Fault Loop Impedance. Topics will include but not limited to: The simple approach The more accurate approach taking account of conductor temperature Calculations taking account of transformer impedance Calculations concerning circuits fed from Sub-Distribution boards Calculations where cable armouring is used as a protective conductor Calculations where conduit or trunking is used as the Protective Conductor (D) Calculations concerning circuit protective conductor cross-sectional areas. Topics include but not limited to: Calculations when the protective device is a fuse Calculations when the protective device is an Mcb Calculations when the protective device is an RCCB

(E) Calculations related to short-circuit conditions. Topics will include but not limited to: AC single-phase circuits The more rigorous method for AC single-phase circuits Three-phase circuits (a) The symmetrical three-phase short circuit (b) The phase-phase short circuit (c) The phase-neutral short circuit (d) The phase-earth short circuit Fault current at the origin of an installation Characteristics of a Fault Protective device (F) Combined Examples All the previous discussions and examples dealt with individual aspects of the design of circuits. In this last section, we will discuss a series of practical design examples of complete electrical installation and show by calculations how each circuit is designed for compliance with the code CP5. Generally speaking, these will be involved: Determine the conductor cross-sectional area Voltage drop supply transformer to main intake switchboard Voltage drop from main intake switchboard to sub-distribution boards Prospective short-circuit current at the terminals of the transformer Prospective short-circuit current at the origin of the installation ie. at the main intake switchboard Prospective short-circuit current at the sub-distribution boards The earth fault loop impedance at main intake switchboard and sub-distribution boards etc. Calculations for determination of cross-sectional area of protective circuit conductors etc. TARGET AUDIENCE This course should be of interest to all Electrical Installation designers, Electrical Engineers from the installation and contracting industry, Plant Electrical Engineers from Industrial Sector as well as all LEWs and any interested parties. This course will benefit greatly those young Electrical Engineers and individuals who are aspiring to be professional engineers as well as those who are preparing to sit for the Practice of Professional Engineering Examination Part 2 (Electrical). CP5 is one of the major topics in the syllabus of the PPE examination Part 2.

CV OF SPEAKERS Er. Lee Keh Sai DFH MIEE CEng PEng Er Lee Keh Sai is a Chartered Electrical Engineer and a Registered Professional Engineer with more than 50 years of industrial experience. He specializes in Electrical Power Engineering, Energy Management and Power Quality Solutions. Er Lee is the Principal of K.S.Lee & Associates which he established in 1970. He has provided consultancy services to many MNC and SMEs. Prior to the establishment of his consultancy services, he held senior staff positions in the Electricity Department of the former Public Utilities Board and later with Shell Eastern Petroleum at their Pulau Bukom Refinery Complex. Er Lee has served in various capacities in many professional associations, government agencies and educational institutions. He had previously served as Deputy Chairman, Board of Governors, for both the ITE and Singapore Polytechnic. He is currently serving as a member of Strata Titles Board and EMC s Market Survellance Compliance Panel. Er Lee is an approved and certified trainer and is currently teaching the core module Motor Driven Systems under the Singapore Certified Energy Managers (SCEM) Program.

Registration Form IES PREPARATION COURSE FOR PPE PART2 EXAM ELECTRICAL ENGINEERING: CP5 on Wiring Regulations and Low Voltage Design Calculations Date : 27 & 28 March 2018, Tuesday & Wednesday Time : 9am 6.00pm Venue : IES Academy@Jurong East (Devan Nair Institute, E2i Building) 80 Jurong East Street 21, #04-10 Singapore 609607 Fees (Include GST): IES Members: $695.50 Non-Members: $909.50 Please register online/fax the completed form by 20 March 2018 before 3pm to: Contact Person: Vincent Chiew Address: 80 Jurong East Street 21, #04-10 Singapore 609607 Tel: 64639211 Fax: 64639468 Participant Details *Name : *NRIC : (Please written in BLOCK Letter) Company : *Designation : *Address 1 : (For mailing of invoice and receipt) Address 2 : (For mailing of Certificate) *Postal Code : Sex : Male / Female *Contact No. : Fax : *Your Email : (For sending of confirmation email, preferable personal unless company sponsored) Please indicate : IES members IES M ship No.: Non-members Contact Person Details (if different from participant) #Name : Designation: #Tel : Fax: #Email : Payment Details Bank / Cheque No.: Amount ($): Sponsored by company * All Fees are inclusive of 7 % GST. * Cheque should be made payable to: Engineers Singapore Pte Ltd. Acceptance of Terms and Conditions for Registrations of IES Academy s Events I agree to abide by the Terms and Conditions for Registration of IES Academy s Events Name : Signature : _ *Mandatory entry #Compulsory Entry for participant who choose to be INVOICE to your company

TERMS & CONDITIONS COURSE REGISTRATION Registration Any registration, whether on-line or fax will be on a first-come-first-served basis and will only be confirmed upon receipt of full payment by Engineers Singapore Pte Ltd unless otherwise invoice to company. All registrations must be submitted with duly completed registration form. Closing Date & Payment The closing date of the event will be 1 week prior to event commencement date or earlier. Cheques should be crossed A/C payee only and made payable to Engineers Singapore Pte Ltd, with the Title of The Event indicated clearly written on the back of the cheques, and submitted with the duly completed registration forms to: IES Academy@Jurong East Devan Nair Institute for Employment and Employability, 80 Jurong East Street 21, #04-10 Singapore 609607 Confirmation of Registration Confirmation of registration will be given at least 1 week before the commencement date via email. If you do not receive the said confirmation email, you are required to contact IESA at 6463 9211 during office hours. IESA reserves the right to allow only confirmed registrants to attend the Event. Withdrawals/Refunds of Fees Written notice at least 1 week in advance before the commencement of the event Full course fee shall be refunded subjected to 4.5% transaction charge. NO refund otherwise. No show of participant would not be accepted as a valid reason for withdrawal/refund. One time replacement is allowed only if written notice is received by us at least 1 week before the commencement of the event. However, when an IES member is replaced by a non-member, the participant has to pay the difference in the relevant fees. Cancellation/Postponement Changes in Venue, Dates, Time and Speakers for the Events can occur due to unforeseen circumstances. IES reserves the full rights to cancel or postpone the Event under such circumstances without prior reasons. Every effort, however, will be made to inform the participants or contact person of any cancellation or postponement. Fees will be refunded in FULL if any Event is cancelled by IESA. UTAP (Union Training Assistance Programme) is an individual skills upgrading account especially for NTUC members. As a member, you enjoy UTAP funding at 50% of the unfunded course fee capped at $250 every year. SkillsFuture Credit (SFC) All Singaporeans aged 25 and above can use their $500 SkillsFuture Credit from the government to pay for a wide range of approved skills-related courses. Visit the SkillsFuture Credit website (www.skillsfuture.sg/credit) to choose from the courses available on the SkillsFuture Credit course directory. Please visit HERE for more information on SFC & UTAP claim. PERSONAL DATA PROTECTION ACT I consent to the processing by Institution of Engineers, Singapore of personal data, including sensitive personal data as defined in the Data Protection Act 2014, about me for the proper purposes of Institution of Engineers, Singapore (IES). I undertake to observe the provisions of the Data Protection Act 2014 in relation to any personal data I may myself hold and process as a Members of Institution of Engineers, Singapore, and I agree to indemnify Institution of Engineers, Singapore from liability for any claims or damages that may arise from the processing of this data. For more information kindly refer to here. Enquiries For further enquiries, please contact IESA general office at Tel: 6463 9211.