Chapter Nursing Homes

Similar documents
Agency for Health Care Administration

Agency for Health Care Administration

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Agency for Health Care Administration

Agency for Health Care Administration

CHAPTER 7 ALTERATIONS LEVEL

Residential Care Facilities Requirements

Residential-based Care Facility R-4 Guideline

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

Life Safety - Means of Egress/Exits NFPA 101

Agency for Health Care Administration

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

Agency for Health Care Administration

City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

For additional information regarding R-3.1 residential care facilities please contact (951)

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

Short Term Accommodations Fire Code Requirements

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

Agency for Health Care Administration

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

Defend In Place 2012 IFC Overview of Institutional Occupancies

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Agency for Health Care Administration

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

DEALING WITH FIRE SAFETY

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIVISION OF ADULT FOSTER CARE LICENSING ADULT FOSTER CARE FACILITIES

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Large Family Daycare Guideline

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015

HAWAII ADMINISTRATIVE RULES DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH GENERAL INDUSTRY STANDARDS

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Residential Based Care Facility Guidelines

Washoe County Department of Social Services

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Agency for Health Care Administration

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

Agency for Health Care Administration

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

APPLICATION FOR Large Family Day Care Permit

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

Agency for Health Care Administration

K SURVEY FOR DATE OF PLAN APPROVAL SURVEY UNDER

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

January 1, 2014 Mandatory Effective Date

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

School Fire Safety Checklist

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Exit Routes. Introduction/Overview. OSHA Regulations. Exit Route

FIRE PREVENTION STANDARDS

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

MULTI-LEVEL & COVERED BOOTH CONDITIONS

Level I Chapter 1 Worksheet

New Facilities. Minimum Requirements

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

2012 B.C. Building Code Compliance Review (Division B Part 3)

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL

Report on First Revisions with Statement June 2014 NFPA 101

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

FIRE PREVENTION AND PROTECTION*

Ch. 54 GROUP B EDUCATIONAL 34 CHAPTER 54. GROUP B EDUCATIONAL OCCUPANCY GROUP

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

Accreditation Program: Hospital

Family Foster Home Fire Safety Evaluation Checklist Instructions

Special attention should be given to new students, to students with special needs and to students enrolled in visiting classes.

Agency for Health Care Administration

FIRE SERVICE FEATURES

Denver Fire Department Fire Prevention Division

ICC CODE CORNER 2015 International Fire Code

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

Element C3.5 Means of Escape

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

AHC Meeting #7 July 12-13, Occupancy WG Report

Transcription:

Chapter 16.01 Nursing Homes Section 1. Licensing. No nursing, convalescent or old age home, as defined in Section 2 of this ordinance, shall be operated except under a license from the City Council of Howard Lake. Such license shall be issued for one year from the date of issue and shall be revocable for cause. Application for license shall be made on the form provided for the purpose and, where deemed necessary, shall include plans showing details of the construction, exit facilities and fire protection equipment. No license shall be issued until the provisions of this ordinance have been complied with and approval has been obtained from the Council. Section 2. Definition. Subdivision 1. A nursing, convalescent or old age home shall mean a building or buildings used for the lodging, boarding or nursing care on a 24-hour basis of four or more infants or children, convalescents or aged persons, but shall not include hospitals and mental or correctional institutions. Subdivision 2. Standards. Approved shall mean accepted by the enforcing official as a result of his investigation and experience, or by reason of test, listing or approval by Underwriter s Laboratories, Inc., the National Bureau of Standards, the American Gas Association Laboratories or other nationally recognized testing agencies. Subdivision 3. Fire Alarm. Automatic fire detection system shall mean a system which automatically detects a fire condition and actuates a fire alarm signal device. Subdivision 4. Person Defined. Person shall mean and include person, persons, children, infants, firm, corporation, partnership or limited liability company. Section 3. Occupancy per Square Foot. Subdivision 1. The number of persons in any room or area used as sleeping quarters shall not exceed the proportion of one adult for each 75 square feet, one child for each 50 square feet, one infant for each 25 square feet. Subdivision 2. Limitations on Occupancy. No occupancy not under the control of, or necessary to, the administration of a nursing, convalescent or old age home shall be contained in any building used as sleeping quarters for such occupancy. Subdivision 3. Story Defined. The basement shall be considered as a story if one-half or more of its clear height is above the average elevation of the ground adjoining the building on all sides. An unoccupied attic or roof space shall not be considered as a story. Section 4. Fire Proofing. Exterior wall of frame construction and interior stud partitions shall be fire-stopped so as to cut off all concealed draft openings both horizontal and vertical between any cellar or basement and the first floor. Such fire stopping may consist of suitable noncombustible material or of wood at least 2 inches thick.

Section 5. Heating. Subdivision 1. Heating apparatus and boiler or furnace rooms shall be separated from other areas by construction having a fire resistance rating of not less than 1 hour. Subdivision 2. Hazardous Areas. Hazardous areas such as basements or attics used for the storage of combustible material, workrooms such as carpenter shops, paint shops and upholstery shops, central storerooms such as for furniture, mattresses and miscellaneous storage, and similar occupancies intended to contain combustible materials which will either be easily ignited, burn with an intense flame or result in the production of dense smoke and fumes, shall be separated from other areas by construction having a fire resistance rating of not less than one hour or shall be protected by an approved automatic fire detection or automatic sprinkler system. Subdivision 3. Unnecessary Storage. The use of attics or basements for the storage of unnecessary combustible materials shall be prohibited. Section 6. Exit Ways. Subdivision 1. At least two exit ways, remote from each other, shall be provided for every occupied story of a building. Subdivision 2. Exit doorways shall be of such number and so located that the distance of travel from the door of any occupied room to an exit doorway from that floor shall not exceed 50 feet in an unsprinklered building nor 75 feet in a sprinklered building, except where buildings are constructed and protected to comply with all requirements applicable to new buildings used for institutional occupancy. Subdivision 3. Width of Exit Stairs. The aggregate width of exit stairs and ramps shall be such as to provide sufficient 22-inch exit units, at the rate of 15 persons per exit unit, for the maximum number of persons that may occupy any floor, except where buildings are constructed and buildings are used for institutional occupancy. Subdivision 4. Exit Requirements. Each occupied room shall have at least one doorway opening directly to the outside, or to a corridor leading directly or by a stairway or ramp to the outside, or to an adjacent room which has such access to the outside. Section 7. Subdivision 1. Stairs. Stairs and ramps serving in required exit ways shall be not less than 36 inches wide in existing nursing, convalescent and old age homes and not less than 40 inches in existing buildings hereafter converted to such use. Subdivision 2. Exit Requirements. At least one required exit doorway from each floor above or below the first floor shall lead directly, or through an enclosed corridor, to the outside. A second or third required exit doorway, where a more direct exit is impractical, may lead to a first floor lobby having ample and direct exits to the outside. Subdivision 3. Shafts. In buildings hereafter converted to use as a nursing, convalescent or old age home, all floor openings, such as interior stairways, laundry chutes and

dumbwaiter shafts, extending to cellar or basement and between occupied floors shall be enclosed in partitions having a fire-resistance rating of not less than one hour, except that in sprinklered buildings such enclosures may be of any construction having a fire-resistance rating of not less than one-half hour or may be wired glass in metal frame -work. Subdivision 4. Stairway Enclosures. In existing buildings used for nursing, convalescent or old age homes all floor openings shall be enclosed as required by Section 7, Subdivision 3, except that stairway enclosures may be either at the head or foot of each stairway from one floor to another. Section 8. Subdivision 1. Corridors. Corridors and passageways in a required exit way shall be at least 36 inches wide. Subdivision 2. Corridors and passageways in a required exit way shall be unobstructed and shall not lead through any room or space used for a purpose that may obstruct free passage. Corridors and passageways which lead to the outside from any required stairway shall be enclosed as required for stairways. Section 9. Subdivision 1. Width of Exits. Exit doorways shall be at least 30 inches wide. Subdivision 2. Fire Doors. All doorways to stairways, vertical openings, passageways or hazardous areas, which are required to be enclosed, shall be provided with fire doors or self-closing smoke-resistive doors (see Section 10, Subdivision 2). Section 10. Subdivision 1. Partition of Floor Space. In buildings of other than fire-resistive (fireproof or semi fireproof) construction, all floors above the first floor occupied by persons under care and exceeding 3,000 square feet in area shall be divided into separate areas by smoke barriers so located as to provide ample space on each side for the total number of beds on the floor. Doors provided in such smoke barriers, shall be smoke-resistive doors, as described in Subdivision 2, so installed that they may normally be kept in open position, but will close automatically or may be released manually to self-closing action. Subdivision 2. Fire Doors. Smoke barriers shall have a fire-resistance rating of not less than one-half hour. Metal, metal-covered or 1-1/8 inch thick solid core flush-type wood doors, so hung as to be reasonably smoke-tight, may be accepted as smoke-resistive doors. Openings in either smoke barriers or smoke-resistive doors shall be glazed with wired glass. Section 11. Subdivision 1. Exit Signs. Signs bearing the word exit in plain legible block letters shall be placed at each exit doorway, except at doors directly from rooms to corridors or passageways and except at doors leading obviously to the outside from the entrance floor. Additional signs shall be placed in corridors and passageways wherever necessary to indicate the direction of exit. Letters of signs shall be at least 6 inches high, except that the letters of intern-

ally illuminated exit signs may be not less than 4½ inches high. All exit and directional signs shall be maintained clearly legible by electric illumination or other acceptable means when natural light fails. Subdivision 2. Fire Resistant Walls. Wall and ceiling surfaces of all occupied rooms and of all exit ways therefrom shall be of such material or so treated as not to have a flame spread classification of more than 75 according to the method for the Fire Hazard Classification of Building Materials of Underwriters Laboratories, Inc., unless the building is sprinklered. Section 12. Combustible Material. All combustible decorative and acoustical material, including textile floor coverings and curtains located in corridors, passageways or stairway enclosures and in lobbies or other rooms or spaces for use by occupants or visitors, shall be rendered and maintained flame-resistant. A material shall be deemed to be flame-resistant if it will not ignite and allow flame to spread over the surface when exposed to match flame test applied to a piece removed from the material and tested in a safe place. The piece shall be held vertically and the bottom edge exposed to a flame from a common match held in a horizontal position, one-half inch underneath the piece, and at a constant location for a minimum of 15 seconds. Section 13. Subdivision 1. Heating Equipment. The heating of buildings occupied as nursing, convalescent or old age homes shall be restricted to steam, hot water or warm air systems employing central heating plants with installation such as to safeguard the inherent fire hazard. The use of portable heaters of any kind is hereby prohibited. Subdivision 2. Heating Equipment. Installation of heating and ventilating systems and equipment in accordance with the Code for the Installation of Heat Producing Appliances, Heating, Ventilating, Air Conditioning, Blower and Exhaust Systems recommended by the National Board of Fire Underwriters shall be deemed prima facie evidence of compliance with the requirement that installation be such as to safe-guard the inherent fire hazard. Section 14. Extinguisher. Approved-type extinguishers shall be provided on each floor, so located that a person will not have to travel more than 100 feet from any point to reach the nearest extinguisher. An additional extinguisher shall be provided in, or adjacent to, each kitchen or basement storage room. Section 15. Subdivision 1. Sprinkler. Buildings which are not of fire-resistive (fireproof or semifireproof) construction shall be protected throughout by an approved automatic sprinkler system. Subdivision 2. Sprinkler. Sprinkler systems shall be provided with an approved water flow alarm. Section 16. Subdivision 1. Fire Alarm. Manually operated fire alarm system shall be provided, except;

a) Sprinkler System. Where the entire building is protected by an automatic sprinkler system equipped with a water flow alarm; or b) Automatic Alarm. Where the entire building is protected by an automatic fire-detection system. Subdivision 2. Type of Fire Alarm. Fire alarm systems shall be of approved type. At least one fire alarm sending station shall be provided on each story, located at a readily accessible point in the natural path of escape from fire. The system shall be so arranged that the operation of any sending station will sound an alarm which is audible throughout the building, or where advisable because of the type of occupancy, the system may be arranged that the initial alarm signal will sound only at some central point where 24-hour service is maintained. Subdivision 3. Automatic Alarms. Automatic fire-detection systems shall be approved supervised systems. Where fixed temperature devices are used they shall be constructed to operate at 165 degrees Fahrenheit or less, except that in spaces where high temperature is normal devices having a higher operating point may be used. Operation of a thermostatic device shall cause an alarm which is audible throughout the building, or where advisable because of the type of occupancy, the system may be so arranged that the initial alarm signal will sound only at some central point where 24-hour service is maintained (See Section 15, Subdivision 2). Section 17. Attendants. Every nursing, convalescent or old age home shall have at least one attendant on duty, awake and dressed therein at all times and in addition, one stand-by attendant within hearing distance and available for emergency service. These attendants shall be at least 18 years of age and capable of performing the required duties of evacuation. No person other than the management or a person under management control shall be considered as an attendant. Section 18. Subdivision 1. Fire Plan. Every nursing, convalescent or old age home shall formulate a plan for the protection of all persons in the event of fire and for their evacuation to areas of refuge and from the building when necessary. All employees shall be instructed and kept informed respecting their duties under the plan. Subdivision 2. Mattresses. Every mattress shall be provided with strong canvas or leather handles so that it may serve as a stretcher when necessary for evacuation. Section 19. Smoking. Smoking shall not be permitted in nursing, convalescent or old age homes. Section 20. Inspection. Every building coming within the scope of this ordinance shall be inspected periodically by representatives of the agencies named in Section 1 in order to insure proper compliance with the provisions of this ordinance. Section 21. Penalties. Any person convicted of violating any of the provisions of this ordinance is guilty of a misdemeanor.