Gas and dual fuel burners Burner sizes 5 and 9 Group 2 apacity.4-5. MBtu/h
Burner sizes 5 and 9 M/MH Turndown ratio, up to :8, firing on gas apacity regulation: modulating (M) for gas, two stage (H) for light fuel oil Burner control system is integrated into the burner Easy to commission and to operate dvanced, user-friendly Oilon WiseDrive 2-4 burner control system improves combustion efficiency and reduces flue gas emissions. Increased savings and fast payback. The Oilon burners, series 5 and 9, are fully automatic gas burners and dual fuel burners. In their design and development special consideration has been given to safety, economic and ecological factors, reliability, and easy servicing. The burners can be fitted on hot water boilers, steam boilers or air heaters. The burners are suitable for use in boilers with either high or low combustion chamber pressure. They are intended for use in covered areas. Installation horizontally, vertically downwards or vertically upwards. % OIL 2 Easy and graphic Oilon WiseDrive 2-4 burner control system. The control panel functions are illustrated with graphic symbols for better usability. The user can easily follow the burner operation phases from the animated symbols on control panel screen. To learn more about our Oilon WiseDrive 2-4 burner control system, please watch the video on Oilon s YouTube channel http://www.youtube.com/watch?v=8h6bntis pplications The burners can be fitted on hot water boilers, steam boilers or air heaters. The burners are suitable for use in boilers with either high or low combustion chamber pressure. They are intended for use in covered areas. Installation horizontally, vertically downwards or vertically upwards. Fuels In different burner types, the following fuels can be used: KP models: light fuel oil, viscosity from 4 to 2 mm2/s (cst) (68 F) GP models: natural gas, propane GKP dual fuel burners: fuel properties as above, natural gas/ light fuel oil. Burners using other fuels are available upon request. Oil pipes KP and GKP models are fitted with one main shut-off valve for oil and each oil pipe leading to nozzle with its own shutoff valve. Valve trains On GP and GKP models all gas fittings comply with with most North merican and European applicable standards. Flame monitoring ll models are supplied with automatic flame monitoring. The flame sensor for the KP models is of photoresistor type, and the GP and GKP models have the UV photocell type. ontrol system The burner control (control unit) is mounted on the burner. The control unit sequences all the operation automatically. In the event of fault conditions control unit automatically goes to lockout and burner shuts down. 46-575/V control voltage transformer comes as a adder and will be supplied in a standalone box GP/KP motor starter inbuilt under cover. GKP motor starter in standalone box supplied loose. This specification is subject to alteration without notice. Other fuels, frequencies, and voltages upon request. For more information, please contact Oilon burner sales.
Light Fuel Oil Burners BURNER KP-5 H KP-9 H apacity, oil, gal/h MBtu/h 5. - 2.4 742-2,995 8.6 5.4,24-4,948 Burner motor ~28 6 V, 6 Hz Output hp urrent /46 V Speed r/min. 2. 5. 4.5 5 Oil hose connection R/8 R/2 Weight lb 97 4 Based on oil density 52,4 lb/ft apacity/backpressure curves KP-5 H 2 in.w 5 5 2 25 GPH KP-9 H 4 in.w 2 5 5 2 25 5 4 45 GPH
KP-5 H 552 / 2.7 27 /.6 28 /.4 F 59 / 2.4 24 / 2.76 85 / 7.28 746 / 29.7 586 / 2.7 9 /.54 57 / 6.8 /.4 4 pcs 2 /.47 4 pcs 75 / 6.89 4 / 5.55 8 /.5 6 / 6. R67 / 24.29 4 / 5.55 / 4. / 4. 22 / 8.7 F ( : 5) KP-9 H 25 / 9.84 88 / 4.76 6 / 24.92 674 / 26.54 5 / 2.4 59 / 4. 29 / 2.95 542 / 2.4 2 x4.47 x.6 26 / 8.5 R694 / 27.2 /.8 25 / 9.84 55 / 6. R67 / 25.8 2 / 7.87 55 / 6. Dimensions in mm/inches
Gas Burners BURNER GP-5 M GP-9 M apacity, MBtu/h 67-2,942 99-4,948 Burner motor ~28-6 V, 6 Hz Output hp urrent /46 V Speed r/min. 2. 5. 4.5 5 Weight lb 88 9 apacity/backpressure curves GP-5 M in.w 2 5 5 2 2 5 5 MBtu/h 4 GP-9 M in.w 2 5 5 2 2 5 5 4 4 5 5 5 5 6 MBtu/h
GP-5 M 544 / 2.42 26 /.28 28 /.4 F 59 / 2.4 24 / 2.76 85 / 7.28 74 / 29.7 98 / 8.62 24 / 9.45 57 / 2.24 9 /.54 2 / 4.72 57 / 6.8 2 /.47 9 / 7.52 max 66 / 6.54 min R64 / 24.96 85 / 7.28 24 / 9.45 / 5.6 8 /.7 24 / 9.45 F ( : 5) 66 / 25.98 /.85 59 / 4. GP-9 M 2 / 4.28 72 / 28.46 /.8 542 / 24.4 29 / 2.95 2 / 8.9 <MOD-BOX>26 / 8.5 <MOD-DIM>2 /.47 <MOD-DIM>2 / 7.87 R694 / 27.2 2 / 4.72 /.8 <MOD-DIM>2 / 7.87 55 / 6. 55 / 6. R67 / 25.8 ( : 5) Dimensions in mm/inches
Dual Fuel Oil Burners BURNER GKP-5 MH GKP-9 MH apacity, oil, gal/h oil, MBtu/h gas, MBtu/h 5. - 2.4 742-2,995 67-2,942 8.6 5.5,24-4,948 99-4,948 Burner motor ~28 6 V, 6 Hz Output hp urrent /46 V Speed r/min. 2. 5. 4.5 5 Oil hose connection R/8 R/2 Weight lb 97 4 Based on oil density 52,4 lb/ft apacity/backpressure curves GKP-5 MH in.w 2 5 5 2 2 5 5 MBtu/h GKP-9 MH 4 in.w 2 5 5 2 2 5 5 4 4 5 5 5 5 6 MBtu/h
GKP-5 MH 552 / 2.55 27 /.6 28 /.4 F 59 / 2.4 24 / 2.76 85 / 7.28 74 / 29.7 98 / 8.62 24 / 9.45 57 / 2.24 9 /.54 2 / 4.72 57 / 6.8 8 /.7 2 /.47 9 / 7.52 max 66 / 6.54 min R64 / 24.96 85 / 7.28 24 / 9.45 / 5.6 24 / 9.45 F ( : 5) 674 / 26.54 5 / 2.4 59 / 4. GKP-9 MH 2 / 4.28 72 / 28.46 /.8 542 29 2 26 / 8.5 2 /.47 2 / 7.87 R694 / 27.2 2 / 4.72 /.8 2 / 7.87 55 / 6. ( : 5) R67 / 25.8 55 / 6. Dimensions in mm/inches
Gas valve selection tables BURNER GS VLVE BURNER MX. PITY MBtu/h *) GS INLET PRESSURE ( W) ONN. TYPE **) 8 2 2 4 GP/GKP-5 M, M/H R2 VGG 2,576 2,995 2,995 2,995 GP/GKP-9 M, M/H R2 " VGG,27,69 4,948 4,948 Note! When the burner is firing other gases than the above mentioned or when the gas inlet pressure is below 8 "W every case must be checked separately. *) The max. capacities given in the table are obtained at a boiler backpressure of and air pressure of 5 psi. 2_M/MH/US/./427 Oilon US Inc. P.O.Box 4, Thomasville, Georgia, US Tel: + 229 26 6546, info.northamerica@oilon.com www.oilon.com