INSTRUCTION MANUAL (ATEX / IECEx)

Similar documents
INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX / IECEx)

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

4) Intrinsic Safety Certification

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INSTRUCTION & SERVICE MANUAL

Approved by: Document no.: EGT

standards: standards:

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

E2S Datasheet v10a

INSTRUCTION MANUAL (ATEX)

TECHNICAL MANUAL EXPLOSION PROOF SOUNDER/ HORN & BEACON BHB 125/ BHB 150. Scope: EXcite USER MANUAL BHB 125 / BHB 150 Date: Page: Checked by: Rev.

IECEx Certificate of Conformity

TECHNICAL MANUAL EXPLOSION PROOF MANUAL CALL POINT BCP 135. Scope: EXcite USER MANUAL BCP 135. Date: Page: Page 1 of 6.

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTRUCTION & SERVICE MANUAL

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

Guide for hazardous areas

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

VERSAFLOW VORTEX Supplementary instructions

P R O D U C T D ATA S H E E T

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Operating Instructions

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

14300 MAINS SEPARATOR ALARM MANUAL

IR25 Dual Gas Series Datasheet

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

official distributor of Newson Gale Ltd.

HYTEK ATEX APPROVED BUND ALARM

INSTRUCTION MANUAL A131 High Level Audible Warning System

Certification Supplement Manual

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Electrical Installations Design, Selection, Erection and Inspection

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Approvals, Certificates and Conditions

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

IR15 Dual Gas Series Datasheet

IECEx Certificate of Conformity

Earth-Rite II PLUS Static Earthing System

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

OPTIBAR DP 7060 Supplementary Instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

HYTEK ATEX APPROVED TANK ALARM

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

Certification Supplement Manual

UL HAZARDOUS LOCATIONS SERVICES

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Certification Supplement Manual

SERIES 46000E Bi-Directional In-Line Deflagration Flame Arrester

PREMIER PLATINUM INFRARED GAS SENSOR

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

YO3 - YO4 / YL4 - YO5 / YL5

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

ATM Lighting sp. z o.o

IECEx Certificate of Conform ity

Technical data sheet TDS0060

Explosion-proof Immersion Heater Type D-8660

Snifter ATEX22 VERSION. User Manual. Distributor

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Technical data sheet TDS0034

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

RM100S RM100S. Intrinsically-Safe Fieldbus Device Coupler. ROUTE-MASTER Fieldbus System. November A1

Annubar Flowmeter Series

Dual certification! Air handling units for potentially explosive atmospheres

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Exp, pressurized systems

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

IR1 Single Gas Series Datasheet

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

1. GENERAL TECHNICAL INFORMATION

WHO WE ARE AND WHAT WE DO

P R O D U C T D ATA S H E E T

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

OPTIWAVE X500 Supplementary Instructions

Synergy Grill User & Engineer Installation & Conversion Guide

Universal Tank Alarm Type Installation, Operation & Maintenance

Temperature sensors SensyTemp TSP Measuring insets TSA

Transcription:

INSTRUCTION MNUL (TEX / IECEx) ExG21D Flameproof Xenon eacon For use in Flammable Gas and Dust tmospheres 1) Introduction The ExG21D is a flameproof beacon certified to meet the requirements of the TEX directive 94/9/EC and the IECEx scheme. The beacon produces synchronised visual warning signals and can be used in hazardous areas where potentially flammable gas and dust atmospheres may be present. The ExG21D has can be used in Zone 1 and Zone 2 areas with gases in groups II, II and IIC and Temperature Classifications of T1, T2, T3 and T4 in an ambient temperature up to +55ºC. The beacon can also be used at an ambient temperature up to +70ºC with a temperature classification of T3. The units can be used in Zone 21 and Zone 22 areas for combustible dusts and have an IP rating of IP 67 and a surface temperature rating of T135ºC if the upper ambient temperature is restricted to +55ºC or T200ºC with an the upper ambient temperature of +70ºC. The ExG21D beacon has two xenon tubes and can produce three different flash patterns. 2) Marking 3) Type pproval Standards The beacon has EC Type Examination and IECEx certificates issued by KEM and has been approved to the following standards:- EN60079-0:2006 IEC60079-0:2004 (Ed4) EN60079-1:2007 IEC60079-1:2007 (Ed6) EN61241-0:2006 IEC61241-0:2004 (Ed1) EN61241-1:2004 IEC60079-1:2004 (Ed1) 4) Installation Requirements General Requirements Flameproof Enclosure d Dust General Requirements Dust Enclosures td The beacon must be installed in accordance with the latest issues of the relevant parts of the S EN 60079 specifications or the equivalent IEC specifications Selection, Installation and maintenance of electrical apparatus for use in potentially explosive atmospheres (other than mining applications or explosive processing and manufacture):- ll units have a rating label, which carries the following important information:- EN60079-14:2008 IEC60079-14:2007 (Ed4) Electrical Installations in Hazardous reas (other than mines) Unit Type No. ExG21D Input Voltage: DC Units 24V or 48V C Units 230V or 115V Code: Certificate No s Warnings: Ex d IIC T4 Ta 50ºC to +55ºC Ex d IIC T3 Ta 50ºC to +70ºC Ex td 21 IP67 T135ºC based on max Ta of +55ºC Ex td 21 IP67 T200ºC based on max Ta of +70ºC Epsilon x: Equipment Group and Category: CE Marking Notified ody No. KEM 00TEX2006 IECEx KEM 10.0002 II 2G/D 0518 DO NOT OPEN WHEN N EXPLOSIVE GS OR DUST TMOSPHERE IS PRESENT EN60079-10:2003 IEC60079-10:2008 (Ed1) Classification of Hazardous reas The installation of the units must also be in accordance with any local codes that may apply and should only be carried out by a competent electrical engineer who has the necessary training. 5) Zones, Gas Group, Category, IP Rating and Temperature Classification The ExG21D beacon has been certified Ex d IIC T3 Ta 50ºC to +70ºC and Ex d IIC T4 Ta 50ºC to +55ºC for gas and Ex td IP67 T200ºC based on max Ta +70ºC and T135ºC based on max Ta +55ºC for dust. This means that the units can be installed in locations with the following conditions:- rea Classification Gas: Zone 1 Zone 2 Explosive gas air mixture likely to occur in normal operation. Explosive gas air mixture not likely to occur, and if it does, it will only exist for a short time. COVER OLTS CLSS 4-80 USE HET RESISTING CLES ND CLE GLNDS (Rated 110ºC) T M. TEMPERTURES OVER 40ºC 90º Gas Groupings: Group II Group II Group IIC Propane Ethylene Hydrogen and cetylene Year of Construction/ Serial No. i.e. 10 / 1D72000001 Temperature Classification: T1 400 o C mb. +70ºC T2 300 o C mb. +70ºC T3 200 o C mb. +70ºC T4 135 o C mb. +55ºC European Safety Systems Ltd. Impress House, Mansell Road, cton, London W3 7QH sales@e-2-s.com Tel: +44 (0)208 743 8880 Document No. IS 2492-P Issue D 18-03-10 Sheet 1 of 4 (1)

rea Classification Dust: Zone 21 Zone 22 Explosive dust air mixture likely to occur in normal operation. Explosive dust air mixture not likely to occur, and if it does, it will only exist for a short time. IP Rating: IP67 T200ºC Ta < +70ºC T135ºC Ta < +55ºC Equipment Category: 2G/D mbient Temperature Range: 6) eacon Location and Mounting -50 C to +70 C (T3 < 55ºC) The location of the beacon should be made with due regard to the area over which the warning signal must be visible. They should only be fixed to services that can carry the weight of the unit. SFETY WRNING: The ExG21D beacon must be mounted with their flashdome in a position between upright and 90º as shown. 90º In order to connect the electrical supply cables to the beacon it is necessary to remove the flameproof cover to gain access to the flameproof chamber. To achieve this remove the four M6 hexagon socket head screws (see figure 2) and withdraw the flameproof cover taking extreme care not to damage the flameproof joints in the process. Note the four M6 screws are Class 4-80 stainless steel and only screws of this category can be used on these beacons. It is therefore important that these screws and their spring washers are kept in a safe place during installation. On completion of the cable wiring installation the flameproof joints should be inspected to ensure that they are clean and that they have not been damaged during installation. lso check that the earth bonding wire between the two casting sections is secure and the O ring seal is in place. When replacing the flameproof cover casting ensure that it is square with the flameproof chamber casting before inserting. Carefully push the cover in place allowing time for the air to be expelled. Only after the cover is fully in place should the four M6 Stainless Steel 4-80 cover bolts and their spring washer be inserted and tightened down. If the cover jams while it is being inserted, carefully remove it and try again. Never use the cover bolts to force the cover into position. 4 off M6 Cover Screws The beacons should be securely bolted to a suitable surface using the 7mm diameter boltholes in the stainless steel U shaped mounting bracket (see figure 1). The angle can then be adjusted as required but the mounting restrictions must be observed (see above). This can be achieved by loosening the two large bracket screws in the side of the unit, which allow adjustment in steps of 18. On completion of the installation the two large bracket adjustment screws on the side of the unit must be fully tightened to ensure that the unit cannot move in service. SFETY WRNING: The flashdome guard must not be removed from the unit at any time. Flashdome Guard Flameproof Chamber Flameproof Cover 8) Power Selection External Earth Terminal Figure 2 It is important that a suitable power supply is used to run the beacon. The power supply selected must have the necessary capacity to provide the input current to all of the beacons connected to the system. Figure 1 S/S racket The following table shows the input current taken by the various units:- Unit Type Nominal I/P Input Max. Voltage Current I/P Volts ExG21D 24V DC 1.2 28V ExG21D 48V DC 600m 56V ExG21D 230V C 280m 253V ExG21D 115V C 560m 126.5V The above table also shows the maximum voltages at which the beacons can be operated. 9) Cable Selection 7) ccess to the Flameproof Enclosure When selecting the cable size consideration must be given to the input current that each unit draws (see table above), the European Safety Systems Ltd. Impress House, Mansell Road, cton, London W3 7QH sales@e-2-s.com Tel: +44 (0)208 743 8880 Document No. IS 2492-P Issue D 18-03-10 Sheet 2 of 4 (2)

number of beacons on the line and the length of the cable runs. The cable size selected must have the necessary capacity to provide the input current to all of the beacons connected to the line. SFETY WRNING: If the ExG21D beacon is used at high ambient temperatures, i.e. over +40ºC, then the cable entry temperature may exceed +70ºC and therefore suitable heat resisting cables must be used, with a rated service temperature of at least 110ºC. For combustible dust applications, the cable entry device and blanking elements shall be in type of explosion protection increased safety "e" or flameproof enclosure "d" and shall have an IP 6X rating according to EN60529:1992 SFETY WRNING: If the ExG21D beacon is used at high ambient temperatures, i.e. over +40ºC, then the cable entry temperature may exceed +70ºC and therefore suitable heat resisting cable glands must be used, with a rated service temperature of at least 110ºC. 10) Earthing oth C and DC beacon units must be connected to a good quality earth. The units are provided with internal and external earthing terminals which are both located on the terminal chamber section of the unit (see figures 2 and 3). When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure. When using the external earth terminal a cable crimp lug must be used. The cable lug should be located between the two M5 stainless steel flat washers. The M5 stainless steel spring washer must be fixed between the outer flat washer and the M5 stainless steel nut to ensure that the cable lug is secured against loosening and twisting. The internal earth bonding wire ensures that a good quality earth is maintained between the flameproof chamber casting and the flameproof cover casting. 12) Cable Connections The cable connections are made into the terminal blocks on the electronic pcb assembly located in the flameproof enclosure. See section 7 of this manual for access to the flameproof enclosure. four-way terminal block is provided on the C beacons, with feeds both boards, therefore there are two live terminals and two neutral terminals so that both input and output wiring can be terminated if more than one beacon is being wired to a single supply. On the DC units there is a three-way terminal on each of the boards making up the electronics assembly. The terminal blocks are wired in parallel with each terminal having a +ve terminal a -ve terminal and an S2 second stage terminal. Therefore both input and output wiring can be terminated if more than one beacon is being wired to a single supply ExG21D DC 21 Joule eacon ExG21D eacon Cover Internal View Internal onding Wire Terminal 2 off M20 Cable Entries Internal Earth Terminal Figure 3 Flash Pattern Pin Header ExG21D C 21 Joule eacon Figure 4 11) Cable Glands The ExG21D beacon has dual cable gland entries which have an M20 x1.5 entry thread as standard. Only cable glands approved for Ex d applications can be used, which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN60079-14:2008 / IEC60079-14:2007. When only one cable entry is used the other one must be closed with an Ex d flameproof blanking plug, which must be suitably approved for the installation requirements. Flash Pattern Pin Header Figure 5 European Safety Systems Ltd. Impress House, Mansell Road, cton, London W3 7QH sales@e-2-s.com Tel: +44 (0)208 743 8880 Document No. IS 2492-P Issue D 18-03-10 Sheet 3 of 4 (3)

Wires having a cross sectional area of up to 2.5mm² can be connected to each terminal way. If an input and output wire is required a 2.5mm² wire can be connected to each terminal way. When connecting wires to the terminals great care should be taken to dress the wires so that when the cover is inserted into the chamber the wires do not exert excess pressure on the terminal blocks. This is particularly important when using cables with large cross sectional areas such as 2.5mm². 13) Synchronised Operation 15) End of Line Monitoring (DC Units) On the ExG21D DC beacon, dc reverse line monitoring can be used if required. ll DC beacons have a blocking diode fitted in their supply input lines. n end of line monitoring diode or an end of line monitoring resistor can be connected across the +ve and ve terminals. If an end of line resistor is used it must have a minimum resistance value of 3k3 ohms and a minimum wattage of 0.5 watts or a minimum resistance value of 500 ohms and a minimum wattage of 2 watts. ll ExG21D beacons that are connected to the same supply line will have synchronised flash patterns provided that they are set to the same flash pattern. 14) Flash Patterns The ExG21D beacons have two xenon tubes and can produce three different flash patterns as listed below. The flash patterns are set internally by the selection of pin headers. On the DC beacons the flash pattern set can be changed externally to produce a second stage by connecting terminal S2 to ve supply line. The C beacons do not have a second stage. DC eacons Stage 2 Single Flash @ 1Hz (oth tubes flashing together) lternate Flash @ 2Hz (Tubes flashing alternately) Double Strike @ 1Hz (One Tube flashing immediately after the other) F SF SF Single Flash lternate Flash Double Strike C eacons Single Flash @ 1Hz (oth tubes flashing together) lternate Flash @ 2Hz (Tubes flashing alternately) Double Strike @ 1Hz (One Tube flashing immediately after the other) Single Flash lternate Flash Double Strike European Safety Systems Ltd. Impress House, Mansell Road, cton, London W3 7QH sales@e-2-s.com Tel: +44 (0)208 743 8880 Document No. IS 2492-P Issue D 18-03-10 Sheet 4 of 4 (4)

EC DECLRTION OF CONFORMITY Manufacturer: Equipment Type: European Safety Systems Ltd. Impress House, Mansell Road, cton London, W3 7QH, UK ExG05D, ExG05E, ExG10D, ExG10E, ExG15D, ExG15E, ExG21D, ExTG05D, ExGL1D Directive 94/9/EC: Electrical and Mechanical equipment for use in explosive atmospheres (TEX) Notified ody for EC type Examination: EC-type Examination Certificate: Notified ody for Quality ssurance Notification: Quality ssurance Notification: Provisions fulfilled by the equipment: KEM Quality.V. Notified ody No.: 0344 Utrechtseweg 310, 6812 R rnhem, The Netherlands KEM 00TEX2006 Sira Certification Service Notified ody No.: 0518 Rake Lane, Eccleston, Chester CH4 9JN, UK SIR 05 TEX M342 Standards applied: EN 60079-0:2006 EN 60079-1:2007 EN 60079-7:2003 EN 61241-0:2006 EN61241-1:2004 Directive 2004/108/EC: Electromagnetic Compatibility Directive (EMC) Standards applied: EN 61000-6-1:2007 EN 61000-6-2:2005 EN 61000-6-3:2007 EN 61000-6-4:2007 ll2 G Ex d llc T3 to T6 or ll2 G Exde llc T4 to T6 ll2 D Ex td 21 lp66 or lp67 T85 C to T200 C The standards EN 60079-0: 2006, EN 60079-7:2003, EN 61241-0:2006 and EN 61241-1:2004 are no longer harmonized. The requirements of these standards have been checked against the harmonized standards EN 60079-0:2009, EN 60079-7:2007 and EN 60079-31:2009 and there were no major technical changes affecting the latest technical knowledge for the products listed above. On behalf of European Safety Systems Ltd., I declare that, on the date the equipment accompanied by this declaration is placed on the market, the equipment conforms with all technical and regulatory requirements of the above listed directives. Martin Streetz Date and Place of Issue: London, 04/07/2012 Quality ssurance Manager Document No: DC-004-Issue_C Telephone: +44 (0)20 8743 8880 European Safety Systems Ltd Facsimile: +44 (0)20 8740 4200 Company Registration No. 2763350 E-mail: sales@e2s.com Registered Office: Impress House www.e2s.com Mansell Road, London, UK, W3 7QH, UK