Sunny Hills. HVAC Maintenance Checklist Template. conducted for. Conducted on 31 Oct :40 PM. Prepared by Jon Nieve

Similar documents
RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

Top of the World Tower

Commercial Maintenance Agreement (CMA) Benefits

USER S INFORMATION MANUAL (2,4)SG13B

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

Packaged Gas/Electric

Preventative Maintenance Tables

USER'S MANUAL PGE Single Package Rooftop

Fig. 1 - Unit PGD4, PGS4, WPG4

IRCC MAINTENANCE QUARTERLY HOME CARE CHECKLIST

Comfort Heating. Comfort Care. 10% Off today s and any future repairs. Same-Day Service and never an overtime charge!

Owner s Information Manual

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Bosch 80% AFUE Gas Furnace BGS80 Model

CHAPTER UTILITY SYSTEMS-HEATING & AIR CONDITIONING. Utility and General System Notes. Heating and Air Conditioning

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Heat Pump Training Course 128 hours, 128 NATE CEHs, 12.8 CEUs Volume Pages, Volume Pages

Heating Maintenance and Repair

power Describe the purpose of lockout/tag-out devices Demonstrate use of lockout/tagout

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

User's Infomation Manual

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Entry Level Assessment Blueprint Heating, Ventilation and Air Conditioning (HVAC)

User s Information Manual

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

User s Information Manual

Indiana WX Oil Furnace Inspection Guide

User s Information Manual

Experienced Worker Assessment Blueprint HVAC - Heating, Ventilation and Air Conditioning

PLP - TERMS AND CONDITIONS Philadelphia Gas Works Residential Parts & Labor Plan Contract

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

USER S INFORMATION MANUAL

Installation & Service Instructions for Jackson & Church Flexaire Packaged Furnaces SDF-125 thru SDF-400 Gas Firing

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to

Jr. Tech (JT-1, 2, 3) Knowledge Areas

User s Information Manual

Before any Ohio winter, it's imperative you ensure your furnace is safe to run, energy-efficient, and ready for heavy, consistent use.

user s information manual

SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

SERVICING AND BREAKDOWN...

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Heating, Ventilation & Air Conditioning (HVAC)

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

INSTALLATION INSTRUCTIONS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

RP8.1Y (ERRATA 1) (202) 2 of 8

Welcome to the Monroe Equipment Inc. Distributor/Dealer Extended Warranty Program

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

MANUAL WARNING FIRE OR EXPLOSION HAZARD. SL280UHNV SERIES WHAT TO DO IF YOU SMELL GAS:

Green Maintenance Needed to Keep HVAC Systems Green

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

POWER VENTER. Model: PVE Series

ML180UH SERIES GAS FURNACE WARNING WARNING

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

USER S INFORMATION MANUAL

SERVICE & PAYMENT PLANS. Note from a valued customer LOOK INSIDE FOR OUR NEW BUDGET CHANGES ESTABLISHED 1919

USER MANUAL SOM SERIES MUL-T-POISE WARM AIR OIL FIRED FURNACE

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

REPLACEMENT PARTS LIST

NJR Home Services General Terms and Conditions Basic Comfort Plans

Indirect gas-fired air heater

USER S INFORMATION MANUAL

Electric Heat Inspection Form Revised September 2012

National Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Direct Fired Heater Model AD Specification

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

XE SERIES INDOOR INDIRECT GAS FIRED HEATING UNIT

Installation instructions for Plenum-mounted add-on electric heaters

Owner s Manual Unit Specifications...3 Rating Information...3. Built Right First... To Last! Warning!

What is Included with a Seasonal Service?

WARNING FIRE OR EXPLOSION HAZARD.

Auto Service Test Review. For the Most Effective Personal Review, Match the Following Questions to the On Line Study Guide Multimedia

Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers

DDYZ SERIES - 13 SEER SINGLE PACKAGED GAS/ELECTRIC AIR CONDITIONER (R-410A, STYLE A,B)

4.6 Advanced Propane Appliance Service and Troubleshooting Performance-Based Skills Assessment 2019

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

Heavy Duty Heater / Air Conditioner Model R-8545

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

PVE SERIES POWER VENTER SYSTEM MANUAL

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

TRSW/G Series Air Conditioning System

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Transcription:

HVAC Maintenance Checklist Template conducted for Sunny Hills Conducted on 31 Oct 2018 03:40 PM Prepared by Jon Nieve Location 102 S Mendel St, Fort Stockton, TX 79735, USA Completed on 31 Oct 2018 04:11 PM Score 35/38.0-92.11%

Failed Responses This section lists responses that were set as "failed responses" in the template used for this audit Question Response Details Check the condenser coil to determine if it needs cleaning. Second floor bedroom air conditioner's coil needed to be cleaned. Appendix 1 Replace air filter or clean reusable type filter. Air filters of second floor air conditioner and first floor guest room air conditioner were cleaned. No need for replacement of filters. Appendix 2 Appendix 3 Check bearings & lubricate blower motor if needed. Lubricated. - 2 -

Audit - 35/38 92.11% Question Response Details Air Conditioner Score (15/17) 88.23% Check and adjust thermostat. Check the condenser coil to determine if it needs cleaning. Second floor bedroom air conditioner's coil needed to be cleaned. Appendix 1 Check all wiring and connections to controls and electrical connections. Check blower belt wear, tension & adjust. Check voltage & amperage draw on all motors with meter. Check compressor contactor. Visually inspect compressor and check amp draw. Check start capacitor & potential relay. Check pressure switch cut-out setting. Replace air filter or clean reusable type filter. Air filters of second floor air conditioner and first floor guest room air conditioner were cleaned. No need for replacement of filters. Appendix 2 Appendix 3-3 -

REFERENCE: Reusable type filter [This is an example of how you can use iauditor to include best practice reference images in your templates to assist with inspections] Install gauges & check operating pressures. Check refrigerant (freon) level and advise if adjustments necessary. Freon level still good. - 4 -

Check condensate drain and pan then advise of any discrepancies. Check expansion valve & coil temperatures. Lubricate parts as needed. Check evaporator coil and advise if dirty or if it needs cleaning. Check the shape that the total system is in and advise customer of discrepancies. Air conditioners of the property are well maintained. Only cleaning of the coils and filters were done. Heat Pump Score (20/21) 95.24% Check and adjust thermostat. Check to make sure that the indoor & outdoor units turn on. Replace the air filter or clean if reusable type. Check bearings & lubricate blower motor if needed. Check blower belt, wear, tension & adjust as needed. Check electrical connections for tightness. Check evaporator coil to determine if it needs cleaning. Check voltage to unit. Check blower motor amp draw. Check electric heaters with amp probe and voltage during heating inspection. Check condenser motor bearings & lubricate if needed. Check condenser motor amp draw. Check refrigerant (freon) level. Check compressor amp draw. Lubricated. - 5 -

Check crankcase heater if compressor has one installed. Check defrost controls. Check reversing valve operation. Check coil temperature. Check condensate drain and pan then advise of any discrepancies. Perform visual inspection of ductwork and make notes regarding discrepancies. Check the shape that the total system is in and advise customer of discrepancies. Electric Heater Check and adjust thermostat. Check to make sure that the indoor unit turns on. Replace the air filter or clean if reusable type. Check bearings & lubricate blower motor if needed. Check blower belt, wear, tension & adjust as needed. Check evaporator coil to determine if it needs cleaning. Check voltage to unit. Check amp draw on motor. Check amperage draw on each element. Check total amperage draw on elements. Check heat sequencer. Check electrical wiring and connections. Check temperature rise. Check supply temperature. Heat Pump is fairly new but only needed some lubrication. - 6 -

Check heat anticipator. Perform visual inspection of ductwork and make notes regarding discrepancies. Check the shape that the total system is in and advise customer of discrepancies. Gas Furnace Check and adjust thermostat. Check heat anticipator. Check to make sure furnace/heat comes on. Replace the air filter or clean if reusable type. Check blower motor bearings & lubricate if needed. Check blower belt wear, tension & adjust as needed. Check the flue for rust & corrosion and advise of discrepancies. Check flue for satisfactory operation. Check, clean, and adjust pilot if needed. Check electronic spark ignition control for proper operation. Check all wiring and connections to controls and electrical connections. Check burners to see if they need cleaning and advise. Check and adjust burners for fuel efficiency. Check heat exchanger for cracks, soot, & rust. Check heat exchanger for cracks when the furnace is hot. - 7 -

Check blower motor & induce draft motor amps. Check manifold pressure. Check fan controls. Test safety shutoff response. Check condensate drain and pan then advise of any discrepancies. Perform visual inspection of ductwork and make notes regarding discrepancies. Check the shape that the total system is in and advise customer of discrepancies. Dual Fuel Heat Pump Furnace Check and adjust thermostat. Check to make sure that the indoor & out doorunits come on, which includes the furnace. Replace the air filter or clean if reusable type. Check bearings & lubricate blower motor if needed. Check blower belt, wear, tension & adjust as needed. Check electrical connections for tightness. Check evaporator coil to determine if it needs cleaning. Check voltage to unit. Check blower motor amp draw. Check electric heaters with amp probe and voltage during heating inspection. Check condenser motor bearings & lubricate if needed. Check condenser motor amp draw. - 8 -

Check refrigerant (freon) level. Check compressor amp draw. Check crankcase heater if compressor has one installed. Check defrost controls. Check reversing valve operation. Check coil temperature. Check the flue for rust & corrosion and advise of discrepancies. Check flue for satisfactory operation. Check, clean, and adjust pilot if needed. Check electronic spark ignition control for proper operation. Check and adjust burners for fuel efficiency. Check heat exchanger for cracks, soot, & rust. Check heat exchanger for cracks when the furnace is hot. Check blower motor & induce draft motor amps. Check manifold pressure. Check fan controls Test safety shut off response. Check condensate drain and pan then advise of any discrepancies. Perform visual inspection of ductwork and make notes regarding discrepancies. Check the shape that the total system is in and advise customer of discrepancies. - 9 -

Completion Overall Comment / Cost of Maintenance Air conditioning system and heat pump are both in good condition. All parts are functioning according to specifications. Freon level still good. Only cleaning for maintenance was done. Everything should be good for another three months. Fee: $100.00 Name and Signature Jon Nieve 31 Oct 2018 04:10 PM - 10 -

Media Appendix 1 Appendix 2 Appendix 3-11 -