A2CM2 Dual Wire Continuous Resistance Monitor

Similar documents
Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

RangerNET Network Ready Constant Monitor Model CM2815

Ohm Metrics. Instruction Manual. Model CM400 Series. Continuous Workstation Monitors

Bench Top Ionizer Installation, Operation and Maintenance

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Universal Clamp Meter

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

FLT93 Installation, Operation and Troubleshooting Guide

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

Chargebuster Ion Gun Installation, Operation and Maintenance

AMC-RAM-4. Refrigerant Alarm Module USER MANUAL. Please read the installation and operating instructions completely and carefully before starting.

BFN. Static Eliminators. Instruction Manual. BFN 803 Ionizing Blower

JENCO ELECTRONICS, LTD.

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

NT DUAL CHANNEL DISPLAY. User Guide

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

1228s Multidrop INSTRUCTIONS. Installation and Operation of the AMC-1228s Electrochemical Sensor Module For Use With Multidrop AMC Monitors

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

BFN. Static Eliminators. Instruction Manual. BFN 802 Ionizing Blower

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Pump-Up Controller MODEL 4062

STATUS ALARM HISTORY ALARM RESET

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

RAM3 Remote Alarm Module

Chargebuster Ion Gun Installation, Operation and Maintenance

Pump-Down Controller MODEL 4052

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Model OEM-2 INSTRUCTIONS FOR USE

Mark 25 Ultrapure Water Conductivity Analyzer

Alarm Tone Generator Model AG17

Global Water Instrumentation, Inc.

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

CHARGED PLATE DETECTORS

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

MODEL QTS-1800 SERIES WALL MOUNT DIGITAL AND ANALOG TRANSMITTER/SENSOR

Critical Environment Ionizing Blower. Model 5810i. User s Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Instruction Manual Model L2 RF Switch

Spy model 673 wet sponge holiday detector ope rati ng instructions

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Warranty Registration

Chargebuster Jr. H/O with Emitter Cassette Installation, Operation and Maintenance

RK Transmitter Technical Notice

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Chore-Tronics Load Cell Indicator

STEP-HEAR Activator (SH-220)

Protocol Station Remote Alarm

3 963/963E Benchtop Air Ionizer Instructions

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

1022 R/T Remote Monitor

RK Combustible Gas Transmitter Operator s Manual

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

MODEL 4000A & 4001A ACCELEROMETER

! "! # Please read these installation and operating instructions completely and carefully before starting.

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC

C0-210 Carbon Monoxide Probe

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

Gas Monitor 1A1 with DSI

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

Single Station Remote Alarm

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

GAS MONITOR Model Model

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Interscan Corporation. Instruction Manual Series Compact Portable Analyzer

User's Guide. Pinless Moisture Meter. Model MO257

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

WARNING Important Safety Information

Dimensions of the Optional Mounting Box (BB-400R/W)

DICKSON KT6 DICKSON. Temperature Chart Recorder. Specifications. Product. Display Symbols. Information & Operating. Contents:

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

D2E Duct Smoke Detector

RK/ RK Oxygen Detector Operator s Manual

GG-NH3 AMMONIA GAS SENSOR. Installation and Operation Manual

KT-100 Door Controller

CRITICAL ENVIRONMENT (C/E) SERIES OVERHEAD IONIZER OWNER S MANUAL

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

Chargebuster Ion Gun Installation, Operation and Maintenance

GG-NO2 NITROGEN DIOXIDE GAS SENSOR. Installation and Operation Manual

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

Gas Monitor 1A1 Series

Freeze Alarm. General Description VD-6300-MCS / VD-6301-MCS. Applications. Features. Specifications. Dimensions

INSTRUCTION MANUAL. Dual Alarm Clock Radio For ipod BCR002IP

Remote Sensor Module: EB-RSM-01

Beacon 800 Gas Monitor Operator s Manual

Installation Manual COPYRIGHT NOTICE

QMF MAINFRAME Installation Manual

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Transcription:

A2CM2 Dual Wire Continuous Resistance Monitor Instruction Manual BOKAR International 10 Enterprise Drive Carbondale, PA 18407, USA Tel: (570) 842-2812 Fax: (570) 842-4290 E-mail: bokar@bomir.com www.bokar.com www.smt-tool.com www.esdmeters.com www.esdpackaging.com www.assembly-smt.com www.smtpreheater.com www.smtrepair.com US Master Distributor: www.bomir.com Bokar International Warehouse: RR#7, Box 7208, Moscow, PA 18444, USA www.bokar.com Page 1 of 5

Contents Contents... 2 Description... 2 Installation... 2 Installation Instructions... 2 Installation Diagram... 3 Mounting Instructions... 3 Mounting Diagram... 3 Operation... 4 Wrist strap monitor operation.... 4 Mat monitor operation.... 4 GND monitor operation.... 4 Maintenance... 4 Product Specifications... 4 Parts Included... 5 Service and Warranty... 5 Description The Ohm Metrics A2CM2 Dual Wire Continuous Resistance Monitor continuously checks two (2) operators and two(2) work surface ground connections. The unit has a nor-mal voltage of 200mV when wearing a wrist strap and 900mV is the maximum (open wrist strap condition). The A2CM2 packaged in a stainless steel case with remote jacks. Utilizing very precise, low-voltage, resistive loop technology, the A2CM2 is an extremely sensitive and reliable ground monitoring instrument that uses the operator s skin resistance to determine if the system is operating properly. Audible and visible alarms are triggered if the operator s resistance exceeds 10 or 35 megohm (selectable at factory with default of 35 megohm). Low resistance also triggers an alarm event. Each monitor uses the AWB2500 series dual wire wrist strap and coil cord although other compatible wrist strap sets may be substituted. Dual conductor wrist straps enable efficient, accurate resistance monitoring and grounding redundancy. Features Ability to monitor two workstations Three color LED to indicate status of operator and workstation: HIGH, LOW, SAFE Audio and LED will give alarms when monitor detects problems on grounding wires from operator to remote jack and remote jack to monitor Installation Installation Instructions 1. Install the Monitor and remote wrist strap terminals in workstation that has a Common Point Ground, an AC out-let and in a location where the alarm indicators will be visible. NOTE: See Mounting for further instructions. 2. Plug a telephone cable from the left remote to OP1 connector on the back of the monitor 3. Plug a telephone cable from the right remote to OP2 connector on the back of the monitor. 4. Connect grounding Zero Ohm wire to the terminal on the back of the monitor labeled ESD GROUND. If there are no grounded ESD mats to be monitored, connect a wire from M1 and M2 terminals to the ESD GROUND terminal on the back of the monitor and skip steps 5 and 6. 5. Connect monitor wire from the first grounded Mat to the terminal on the back of the monitor labeled M1. 6. Connect monitor wire from the second grounded Mat to the terminal on the back of the monitor labeled M2. Note: The Mat must be grounded with a Zero Ohm wire for proper mat monitoring operation. If your workstations are required to be grounded with 1M resistance the monitor must be modified. If monitor has optional low resistance monitoring called GND monitoring, but there are no grounded connections needed to be monitored, connect a wire from G1 and G2 terminals to ESD GROUND terminal on the back of the monitor and skip steps 7 and 8. 7. Connect monitor wire the first grounded connection to the terminal on the back of the monitor labeled G1. 8. Connect monitor wire the second grounded connection to the terminal on the back of the monitor labeled G2. 9. Plug power supply into the PWR connector on the back of the monitor and into the power line. Bokar International Warehouse: RR#7, Box 7208, Moscow, PA 18444, USA www.bokar.com Page 2 of 5

Installation Diagram Bokar International Figure 1: Back View Figure 2: Connection of Mat1 and Mat2 to the monitor and ESD Ground Mounting Instructions 1. Install monitor in a location where alarm indicators will be visible and audible to operator such as under a shelf or on workstation table top. 2. Mount monitor securely in place with Velcro. 3. Install remote wrist strap terminals in a convenient lo-cation for operators. Frequently units are mounting on the underside of the workbench. 4. Mount terminals with two (2) screws each. 5. Power outlet and Common Point Ground (CPG) can be in any convenient place on workstation. Mounting Diagram Figure 3: Mounting of monitor and remote jacks with outlet and CPG Bokar International Warehouse: RR#7, Box 7208, Moscow, PA 18444, USA www.bokar.com Page 3 of 5

Operation Wrist strap monitor operation. Monitoring begins when the coiled cord of the wrist strap is plugged into the remote jack. The status of a dual wrist strap resistance is indicated by the tricolor LED and audible Alarm: Stand-by indication. If operator wrist strap is not plugged into the remote, OP (operator) led will be TURNED OFF. Low alarm. If operator wrist strap is plugged into the remote and resistance is less than 1.8M, OP led will be YELLOW and audible alarm will sound. Normal indication. For normal operating resistance OP led will be GREEN. High alarm. 1. If the operator wrist strap is plugged into the remote and resistance is higher than maximum, the OP led will be RED and audible alarm will sound. 2. If remote is not plugged into the monitor, or there is a break in the connection between the monitor and remote, OP led will be RED and audible alarm will sound. 3. If the wrist strap is plugged into the auxiliary AUX socket and OP socket is not used, high alarm will sound to indicate that operator is plugged into a non-monitored connection. If the operator is plugged into an OP socket, plugging a second wrist strap into an AUX socket will not cause an alarm. The Alarm settings for the wrist strap are 1.8M for Low alarm and 35M for high alarm Mat monitor operation. The status of Mat resistance is indicated by the tricolor LED: Normal Mat indication. For normal operating resistance, led will be GREEN. High Mat alarm. If MAT resistance is higher than maximum limit, the led will be RED and audible alarm will sound. Alarm setting for a mat is 3.5M for high alarm. GND monitor operation. Normal GND indication. For normal operating resistance led will be GREEN. High GND alarm. If GND resistance is higher than maximum limit, led will be RED and audible alarm will sound. GND inputs alarm setting for high alarm is 10 Ohm. Maintenance CALIBRATION AND PERIODIC TESTING: Alarm resistance limits are set by the precision resistors inside the tester and never need calibration. You can verify proper operation of the monitor by periodically testing monitor with a resistance limit comparator box from Bokar International, part number A2CM2PV. Product Specifications Performance Specifications Dimensions (W x D x H) Weight Power Supply 4 x 3 x 1 (10.16 x 7.62 x 2.54 cm) 6.8oz 120VAC 60hz, 9-15 Volts DC, 100-600 ma, 2.1mm center positive output Unit monitoring capabilities A2CM2 A2CM2PV 2 wrist straps/persons + 2 mats Periodic verification tool for A2CM2 Bokar International Warehouse: RR#7, Box 7208, Moscow, PA 18444, USA www.bokar.com Page 4 of 5

Performance Specifications Maximum operator voltage (alarm condition) 900mV Typical operator voltage < 200mV Maximum GND current 1.25V Maximum GND voltage (alarm condition) < 900mV Maximum GND voltage (open circuit condition) 100μA Maximum GND voltage (alarm condition) 1mV Maximum GND voltage (open circuit condition) 50mV Alarm Limits Min Typical High Wrist strap low limit* 1.6M 1.8M 2.3M Wrist strap high limit 30M 35M 40M Mat high limit 3.0M 3.5M 4.0M GND (tool) high limit 9.5Ω 10Ω 10.5Ω Temperature limits Adjustments 50 F (10 C) to 122 F (50 C) No field serviceable components; see periodic verification tools *Operator wrist strap is grounded through 2M resistors inside the monitor Parts Included 1. CM2015 Dual workstation monitor 2. Two (2) remote terminals boxes 3. Plug-in Power Supply (9-15 Volts DC, 100-600 ma, 2.1mm center positive output) 4. Instruction manual 5. Two (2) 10 ft., 4 wire, telephone cables 6. Velcro 7. Four (4) mounting screws 8. Two (2) 6 ft. dual-wire anti-allergic wrist-straps (optional) Service and Warranty Bokar International provides a limited warranty. All new products are guaranteed to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Liability is limited to servicing (after evaluating, repairing or replacing) any product returned to Bokar International. The company does not warrant damage due to misuse, neglect, alteration or accident. In no event shall Bokar International be liable for collateral or consequential damages. To receive service under warranty, please contact Bokar International Technical Support. BOKAR International 10 Enterprise Drive Carbondale, PA 18407, USA Tel: (570) 842-2812 Fax: (570) 842-4290 E-mail: bokar@bomir.com www.bokar.com www.smt-tool.com www.esdmeters.com www.esdpackaging.com www.assembly-smt.com www.smtpreheater.com www.smtrepair.com US Master Distributor: www.bomir.com Bokar International Warehouse: RR#7, Box 7208, Moscow, PA 18444, USA www.bokar.com Page 5 of 5