Dual Probe Vaccine Temperature Data Logger w/ Software-Less Reporting

Similar documents
Refrigerator/Freezer Thermometer

Refrigerator/Freezer Thermometer

WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

PRODUCT SPECIFICATION

THERMOMETERS Dataloggers/Refrigerator

LogTag TICT - is0 Tag

WHO PQS-Code E006/016. Q-tag CLm doc USB Multi- Limit Temperature Indicator

MIRADOR Real Time Monitoring

D3 Wireless temperature alarm & monitoring system family. tek-troniks

UTRED day Logger with display

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

Specifications Minimum Typical Maximum Unit

USRIC-8(M) USB PDF Temperature Recorder. Product User Guide. LogTag Recorders Ltd

UTRED30-WiFi. 30 day WiFi Logger with display

DATAssure. Laboratory wireless alarm & monitoring system

ISO New Product Catalog. Addendum 2014 TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS

EL-USB-1-LCD Temperature Data Logger with LCD

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Global Laboratory Catalog

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Fridge-tag 2 L. with external sensor OPERATION MANUAL

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Data Logging Solutions

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

EL-USB-1-LCD Temperature Data Logger with LCD

iminiplus PDF User Guide Version 2.0

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Fridge-tag 2 L OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

HOBO U14 Data Logger User Manual

EasyLog Data Logger Series

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Exceptional data integrity. Complete peace of mind.

ELMTEC. Kattreppeln Königslutter / /

Cold chain monitoring technologies. Facility monitoring

2014, TempSen Electronics Company

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY

EL-USB-TC Thermocouple Data Logger with USB Interface

MR SERIES CARD LOGGERS

Temperature Monitoring System. Specifications

EasyLog Data Logger Series

Common Customer Challenges

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

The 6 Most Important Parts of a Temperature Monitoring System

EL-OEM-3 OEM Packaged Voltage Data Logger

NYS Vaccines for Children (VFC) Program Fridge-Tag 2L Data Logger: Implementation and User Guide

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Sirius Technologies, Inc.

What's new in LogTag Analyzer 2.8

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

IceSpy System5. A big deal in the world of large scale environmental monitoring INDUSTRY SPECIFIC PRODUCT SOLUTIONS HEALTHCARE.

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module


The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

ThermoControl 0 C - 10 C - 20 C - 30 C

data logger DL200H DL200D DL200L

USER MANUAL USB Multi-Function Datalogger Model RHT35

Our Extended Personal Electronic Dosimeter (PED) Family

User Manual. Humidity-Temperature Chart Recorder. Model RH520

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Danfoss gas detection units

Traceable Ultra Waterproof Thermometer

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

Process & TeMPerATUre UniversAl input DigiTAl MeTers

THX-DL Data Logger USER & INSTALLATION MANUAL V

Simple, digital wireless reporting.

InTemp CX Temperature Logger (CX40x) Manual

Vaccine Storage and Handling Training. Onondaga County Health Department November 2012

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

Introduction. OM-THA2

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

FITOCLIMA 600 & 1200 STABILITY

Danfoss gas detection unit Type GD Heavy Duty

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

Installation and User Instructions

What's new in LogTag Analyzer 2.8

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

VIBRA-series: VIBRA, VIBRA +

Smart Wireless Sensor

Ion Gateway Cellular Gateway and Wireless Sensors

Smart Wireless Sensor

Accessories, interfaces, sensors and complete solutions.

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

FITOCLIMA 600 & 1200 STABILITY

Instruments. for hydroponics & horticulture 2016

Ultra Low Freezers. Blood Management Solutions. B Medical Systems U Range

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Are you still stuck with the current status of manual thermometer recording? X Labor Intensive X No History X Inaccurate

SMS GSM Alarm Messenger

Transcription:

1 2018

Dual Probe Vaccine Temperature Data Logger w/ Software-Less Reporting Exceeds CDC & VFC Data Logger Requirements for Vaccine Temperature Monitoring and Compliance Thermco s new Dual Probe ACCRT8017 Data Logger is the most powerful logger to date. Designed to meet today s CDC s and VFC s requirements for vaccine storage and monitoring. Monitor both the refrigerator and freezer temperatures simultaneously or add the optional ACCRTAMB ambient temperature sensor and log the room temperature, and either a refrigerator or freezer. The ACCRT8017 can record 24 million records. Each record contains date, time, sensor temp readings, sensor status: normal - hi alarm - low alarm sensor failure, and battery status: charging or power level remaining. ACCRT8017 is a self-contained data logger that requires No PC Software to generate a complete Excel csv report. Large easy to read display for viewing both channels current-min-max temperatures plus time and battery status. Each data logger is certified, serialized and traceable to NIST from Thermco s own ISO17025 calibration laboratory, accredited by ilac-mra to assure accuracy and compliance with all regulatory requirements. (accreditation no. 69071) Available soon Flash-Alert SD Wi-Fi / Memory Card accessory for ACCRT8017 that will upgrade the data logger with the following functions... Wireless Email and SMS Alerts, 2 Daily Status Reports, and a Real-Time Dashboard via Web Browser. EXCEEDS Current CDC & VFC Requirements for Vaccine Storage and Monitoring NIST/ ilac-mra Traceable Certificate Supplied High Accuracy ±0.3 C (±0.6 F) Log 24 Million Readings on 2G Micro SD Card Data File in Excel.CSV Format Retrieve Data from Logger with Removable SD Memory Card or by USB cable to PC Logger Records Date, Time, P1 & P2 Temp, and Battery Level in CSV file Logging Interval Selectable from 1 to 720 Minutes Detachable Shatter Proof Vaccine Size Bottle Probes Bottles Filled with Bio-Safe Glycol Buffer Medium Large LCD Display shows Current Min Max Temperature for each Sensor plus Time and Low Battery Indication User Adjustable Low and High Alarm Limits Setting for Each Sensor Audible and Flashing LED Alarm Indicators Temperatures in C or F Time in 12 or 24 Hour Format Flip Out Desk Stand Battery Life About 10 Months in Continuous Operation with no alarms CATALOG NO. ACCRT8017 ACCRTAMB ACCFA1 Dual Probe Vaccine Data Logger to Monitor Refrigerator or Freezer. Includes... 2yr. NIST Traceable Certificate, 2 Vaccine Bottle Sensors, 2GB Micro SD Card, Micro SD Card Reader, MicroSD to SD card adapter, Mini USB Cable, 3 x AA batterys,110v USB Power Adapter Optional: Ambient Room Temperature Sensor Optional: Flash-Alert SD Wi-Fi / Memory Card Provides SMS Alerts (Information and availability soon) Measuring Range External (Bottle Probe): -50 to 70 C (-58 to 158 F) Internal: 0 to 50 C (32 to 122 F) Display Accuracy ±0.3 C (±0.6 F) Over Full Range Display Resolution 0.1 Display Reading Update 10 Seconds Memory Removable 2G Micro SD Card (Max: 4G) Memory Capacity 24 Million Readings Data Logging Interval Once Per Minute to Once Per 720 Minutes User Option Alarm Limit Setting Resolution 0.1 Default Alarm Value Low -10 C, High 50 C Time Accuracy ±1 Second Per Day Time Display Format 12/24 Hour Format User Option Effective Calendar Period 2016-2099 Battery 1.5 Volt Type AAA x 3 Pieces Battery Life About 8000 Hours In Continuous Operation with No Alarm Triggered Working Ambient Temperature 0 to 50 C (32 to 122 F) Display Size 54(W) X 64(H) mm External Sensor Cable Length 2000 mm External Sensor Bottle Size 19.5 Dia. X 40mm (H) Pe Bottle Product Size 83 (W) X 120 (H) X 26 (D) mm 2

Flash-ALERT Wireless Email & SMS Alert Notifications Upgrade Card for ACCRT8017 Catalog No. ACCFA1 Ambient Room Temperature Sensor Accessory for ACCRT8017 Data Logger Catalog No. ACCRTAMB 3

LogTag Vaccine Temperature Data Logger with 30-Day Summary Summary of TRED30-16R updates from previous model TRED30-7. Built-in audible alarm. New, easy to read LCD display with 30 day summary in calendar format. Up to 15.9K recordings - Enough memory for 66 days at 6 minute logging. Auto-pause function - unplugging the external probe automatically suspends alarm & statistics processing. EXCEEDS CDC/VFC Vaccine Monitoring Guidelines The LogTag TRED30-16R is a Bio-Safe Glycol / Water Bottle Medium CDC / VFC compliant ISO/IEC 17025 NIST traceable temperature data logger used to monitor & record the temperatures of vaccines in refrigerators or freezers. The LogTag TRED30-16R measures and stores up to 15.9K readings over a temperature range of -40 to +99 C (-40 to +210 F) via external bottle probe. The display is designed to show At A Glance if temperature excursions have occurred during the current day and up to the previous 29 days. The display also shows the current temperature reading, the current time, recording status and battery status. The alarm is triggered if temperature readings are outside preset alarm limits. The status indicator changes from a to a and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option. Details of any excursions in the preceding 30 days can be checked directly by inspecting the statistics history on the recorder s display or in more detail by downloading the logged data via a standard LogTag Interface cradle to LogTag Analyzer operating software. NIST Traceable w/certificate Data Logging Records time and temperature data for later download Day alarm summary - Displays in calendar format alarms for the last 30 days Current time & temperature - Shows the current time and temperature when not in review mode Push Button Logging start with optional delayed start or specific Time & Date start Rapid Download! Takes only seconds to download recordings Pre-Start logging - LogTag can be configured to record even if it has not been started High performance at low cost Thin flat case Fits easily into packaging and thin enough to be easily mailed letter rate Real time clock records time & temperature simultaneously Easy to use LogTag Analyzer software that runs on any PC configures LogTag for recording then downloads resulting data for analysis. Data can also be exported to fomats compatible with other applications such as Excel CATALOG NO. LTTRED3016R LTTRED3016RUSB LTISOLOGTEMP LTIUSB LTBRACKET Temperature Data Logger - 15.9K logs w/probe and Vial Note: LTIUSB (USB Interface Cradle) required for operation VFC Compliant Temperature Data Logger, w/probe, Vial and USB Interface Cradle ISO17025/IEC Accredited Temperature Calibration USB Interface Cradle Wall Mount Bracket Temperature Sensor -40 C ~ +99 C (-40 F ~ +210 F) Measurement Range Operating Temp Range -30 C ~ +60 C (-22 F ~ +140 F) Storage Temp Range -10 C ~ +40 C (-14 F ~ +104 F) Rated Temperature ±0.5 C ( ±0.9 F) for -20 C to +40 C (-4 F to +104 F), typically ±0.3 C (0.6 F) Reading Accuracy ±0.8 C ( ±1.4 F) for -40 C to -20 C (-40 F to -4 F), Typically ±0.5 C (0.9 F) Rated Temperature Reading Resolution 0.1 C (0.2 F) for measurements -40 C to +50 C (-40 F to +122 F) Please see the Rated Native Resolution chart above. LogTag Analyzer currently displays to one decimal place of C or F. The native resolution is what is stored in the LogTag. 15.9K temperature readings. 66 days @ 6min logging. Recording Capacity Day summary statistics memory (for display on LCD): up to 30 days of Max/ Min/duration and alarm trigger statistics. Sampling Frequency Configurable from 30 seconds to hourly. Sensor Reaction Time Typically less than 2 minutes (T90) in moving air Push button start or specific date & time. Logging Start Options Optional start delay of up to 18 hours. Recording Indication State indicator REC Download Time Typically less than 10 seconds for full memory Environmental IP61 (when vertically mounted or hung). Power Source 3V CR2032 (LiMnO2) coin cell battery, user replaceable Battery Life Typically 1 year of operation. Size 93mm(H) x 54.5mm(W) x 8.6mm(T) Weight 41 grams without External Probe Case Material Polycarbonate Standard External Standard: 1.5m (4 11 ). Probe Cable Lengths Extended: 3m (9 10 ) (recommended maximum). External Probe Type PTFE (FDA food contact rated) coaxial. 4

Vaccine Temperature Data Logger Software-Less Reporting Generation Bio-Safe Glycol / Water Bottle Medium Record Room Temperature and Refrigerator (or Freezer) Simultaneously EXCEEDS Current CDC & VFC Requirements for Vaccine Storage And Monitoring NIST Traceable w/certificate High Accuracy ±0.5 C (±1.0 F) Log 24 Million Readings on 2G Micro SD Card Data File in Excel.CVS Format Retrieve Data from Logger with Removable SD Memory Card or by USB cable to PC Logger Records Int/Ext Min/Max Temps into Memory Logging Interval Selectable from 1 to 720 Minutes Detachable Shatter Proof Vaccine Size Bottle Probe Filled with BioSafe Glycol Large LCD Display shows Internal / External Current Min/Max Temps, Time and Battery Strength User Adjustable Low and High Alarm Limits Setting for Each Sensor Audible and Flashing LED Alarm Indicators Temperatures in C or F Time in 12 or 24 Hour Format Flip Out Desk Stand Battery Life About 10 Months in Continuous Operation with no alarm triggered Thermco s new ACCRT8002 Data Logger is the most powerful logger designed to meet today s CDC s and VFC s requirements for Vaccine Storage and Monitoring. The ACCRT8002 is a SELF CONTAINED DATA LOGGER that requires NO PC SOFTWARE to generate a complete Excel CVS report. Monitor both the Ambient Room and Refrigerator (or Freezer) Temperatures Simultaneously. Large Easy to Read Display for viewing the current Room and External BottlProbe Temperatures -- Min and Max Recorded Temperatures -- Time and Battery Strength. Each Thermometer is Certified, Serialized and Traceable to NIST in Thermco s own ISO17025 Calibration Laboratory, accredited by ilac-mra to assure accuracy and compliance with all regulatory requirements. (Accreditation No. 69071) CATALOG No. ACCRT8002 Ambient - Refrigerator/Freezer Vaccine Data Logger w/ Vial & Probe, Mini USB Cable, 110v USB Power Adapter Micro SD Card, USB Card Adapter Measuring Range External Bottle Probe: -50 to 70 C (-58 to 158 F) Internal Unit Sensor: 0 to 50 C ( 32 to 122 F) Display Accuracy ±0.5 C (±0.9 F) Over Full Range Display Resolution 0.1 Display Reading Update 10 Seconds Memory Removable 2G Micro SD Card (Max: 4G) Memory Capacity 24 Million Readings Data Logging Interval Once Per Minute to Once Per 720 Minutes User Option Alarm Limit Setting Resolution 0.1 Default Alarm Value Low -10 C, High 50 C Time Accuracy ±1 Second Per Day Time Display Format 12/24 Hour Format User Option Effective Calendar Period 2014-2099 Battery Life About 8000 Hours In Continuous Operation With No Alarm Triggered Battery 1.5 Volt Type AAA x 3 Pieces Working Ambient Temperature 0 to 50 C (32 to 122 F) Display Size 70(W) X 64(H) mm External Sensor Cable Length 2000 mm External Sensor Bottle Size 19.5 Dia. X 40mm (H) Pe Bottle Product Size 94 (W) X 110 (H) X 25 (D) mm 5

Fridge-tag 3 Wireless Vaccine Temperature Data Logger Receive Real-time Temperature Excursion Alerts via SMS Notifications Software-Less PDF Generation of Temperature, Alarm Data Plus Graphs Fridge-tag 3 is the ideal Temperature Data Logger for the continuous monitoring of sensitive Vaccines and Pharmaceuticals stored in medical refrigerators & freezers. Real-time SMS text messaging notifications of temperature excursion are transmitted wirelessy by Celluar GSM (Global System for Mobile communication). The Fridge-tag 3 is not dependent on Wi-Fi and local networks in order to send sms messages, and even during power outages can send critical Alerts to your Cell Phone. No software needed to generate temperature & alarm data. As soon as the Fridge-Tag 3 is connected via USB to a PC or Mac it creates a PDF and an CSV file. The PDF file provides a daily summary of temperature activity (selectable: 28, 56, 84 or 112 day overview) PLUS 8 weekly graphs of temperature performance. Temperature readings are recorded every 5 minutes and can be found in a table within the TXT file. Thanks to the electronic signature the raw data can be verified as compliant with FDA regulations 21 CFR Part 11. This means that each month you obtain a report and the assurance that your temperaturesensitive goods are stored in accordance with regulations. The data logger s external thermometer probe is sealed in a Bio-Safe glycol filled bottle to buffer temperature variations. Meets and exceeds the latest VFC CDC requirements published in the Guidelines for Storage and Temperature Monitoring of Refrigerated Vaccines NIST Traceable with 2yr Certificate Removable Probe True Seal Flat Ribbon Probe Cable Bio-Safe Glycol / Water Probe Medium Current Temperature Display No Software Needed for Reporting or Computer Connection 30 Day Status on Screen Press for 30-Days of Min/Max History PDF report... 60 days of temperature & alarm data High/Low Alarm 43,200 Temperature Observations Monthly Meets FDA 21 CFR Part 11 requirements Accuracy ±1 F (0.5 C) Weekly Graphs 4 graphs Each with 1 Week of Tempearture Data 56 Days of Information Date in USA Format Date of Activation Give State Health Departments a warning when a device will be out of calibration Battery Level Indicator Showing Full, Middle and Low CATALOG No. BERFRIDGETAG3 Wireless Vaccine Data Logger, NIST Traceable Certificate, Vial & Probe Note: 2 year data plan required for SMS Alerts External Dimensions (L x W x H) 136 x 98 x 21 mm Size of the LCD Display 95 x 27 mm Weight 170 g Storage Condition (inactive) 0 C to +30 C +32 F to + 86 F Operating Temperature (Main housing) +5 C to +50 C* +41 F to +122 F (Display visible) -10 C to +55 C +14 F to +131 F Alarm Temperature Range -30 to +50 C in 0.1 C increments (-22 to +122 F) Alarm Limits 2 individually programmable alarm limits (1 upper and 1 lower alarm limit) Warning Limits 2 individually programmable alarm limits (1 upper and 1 lower alarm limit) Alarm Time 1 Minute to 23h 59min Temperature measurement interval Every minute (Log interval programmable. Recommended 5, 10, 15 minutes) Accuracy of temperature +/- 0.8 C from -25 to -10 C (+/-1.44 F from -13 to +14 F) measurement +/- 0.5 C from -10 to +40 C (+/-0.9 F from +14 to +104 F) +/- 0.8 C from +40 to +55 C (+/-1.44 F from +104 to +131 F) Measurement accuracy of the time Daily time updates (depending on network operator) if not supported +/- 30 min / year Calibration Every device is calibrated / NIST / ILAC traceable Memory Space 30 day as a display and 60 days overview in a PDF report Date / Time programming Date and time will be set automatically when device is activated (via GSM network) Battery Protection Class 2D Code on Label Operating Lifetime Activation Stopping Configuration Data Communication Alarm Indication Manipulation Format of the original document Free software for verifying PDF and ASCII Files Standards 6 Lithium Polymer Li-ion battery - Complies with IATA DGR Packaging Instruction UN3481 PI 967 section ll and is therefore not considered as dangerous good. IP50 (IP64 without external sensor) GS1 and data matrix Min. 3 years useful life / at least 72 hours power back up Press SET and READ button simultaneously for more than 3 seconds No stop function Pre-set by Berlinger & Co AG or for self configuration via SMS or server Optional: To be pushed on a regular interval to a predefined server Buzzer, SMS or server Fridge-tag 3 GSM cannot be manipulated or reset without destroying it. ASCII (it can also be imported by many ERP systems) / PDF JAVA / The software verifies the digital signature of the ASCII and PDF files. FDA regulation 21 CFR Part 11 compliant. Software is compliant with GAMP 5 requirements. ASTM 2500, 21 CFR Part 11, 21 CFR Part 820, ICH Q8/Q9, ANSI/IEEE 829/830/1008, EN 12830, 2002/95 EC Directive (RoHS), EN/IEC 60529 IP protected classes, IATA Regulations, EN 301511, EN 301489-1/7, EN 60950-1 + A2:2013, EN 62133, FCC part 15B

Fridge-tag 2L Vaccine Data-Logger Software-Less PDF & Graph Report Generation 3 Year NIST Traceable Certificate & Updated Features (in red) Bio-Safe Glycol / Water Bottle Medium Fridge Model Shown w/ Yellow Label Freezer Model Shown w/ Blue Label Exact measurement of temperature and time The Fridge-tag 2L is a high-precision, electronic temperature monitor. It is 100% calibrated and has a measurement precision of ±0.5 C. Temperature measurement occurs every minute throughout the entire monitoring time. This guarantees faultless and extremely accurate measurement results. Even if an alarm limit has been exceeded and the Fridge-tag 2L alarm is displayed, it accumulates each additional temperature threshold violation. The precision time measurement is generated by a built-in quartz clock. NIST/ILAC Traceable with 3yr. Certificate. Data read-out without software via USB As soon as the Fridge-tag 2L is connected via USB to a PC or Mac, it creates a PDF or an ASCII file. Thanks to the electronic signature the raw data can be verified to be in compliance with the FDA regulations 21 CFR Part 11. Any changes are immediately recognized and the document rejected. This means that each month you obtain a report and the assurance that your temperature-sensitive goods are stored and recorded in accordance with regulations. CATALOG No. BERFRIDGETAG2L Fridge - Vaccine Data Logger w/vial & Probe, Alarm @ 2.0 to 8.0C BERFREEZTAG2L Freezer - Vaccine Data Logger w/vial & Probe, Alarm @ -20.0 to 1.0C FRIDGETAG2USA User Set Alarm Vaccine Data Logger, 2 Individually programmable alarm limits (1 upper and 1 lower alarm limit) NIST Traceable with 3yr. Certificate Audible Alarm Now with Weekly Temperature Graphs Improved Battery Life Battery Level Indicator Improved LCD Contrast Daily Verification Log w/time-stamp Longer Sensor Cable 62 (optional) Removable Probe True Seal Flat Ribbon Probe Cable Bio-Safe Glycol / Water Probe Medium Current Temperature Display No Software Needed for PDF Reporting 30 Day Status on Screen Press for 30-Days of Min/Max History High/Low Visual Alarm 43,200 Temperature Observations Monthly Meets 21 CFR Part 11 requirements Accuracy ±0.5 C (1.0 F) External dimensions (L x W x H) 128 x 75 x 14.5mm Temperature measurement interval Size of the LCD display 95 x 27mm Accuracy of Weight 96g temperature measurement Storage condition (inactive) -30 C to +60 C / -22 F to +140 F Accuracy of time Operating temperature -30 C to +55 C / -22 F to +131 F Calibration (Display visible) -10 C to +55 C / +14 F to +131 F Date/Time programming -30 C to +50 C, in 0.1 C increments Alarm temperature range Protection class / -22 F to +122 F 2 individually programmable alarm limits Operating lifetime Alarm limits (1 upper and 1 lower alarm limit) Manipulation Alarm time 1 Minute to 23h 59min Every minute ±0.5 C (-5 C to 30 C), ±0.6 C (beyond this range) ±1.0 F (+23 F to +86 F), ±1.1 F (beyond this range) ±30 minutes / year Every device is calibrated / NIST/ILAC traceable Date and time will be set when device is activated (see operation manual) IP67 up to years - expiry date printed on label Fridge-tag 2 cannot be manipulated or reset without destroying it. 7

LogTag Cryogenic Temperature Data Logger Built-in audible alarm. New, easy to read LCD display with 30 day summary in calendar format. Up to 15,900 recordings - Enough memory for 66 days at 6 minute logging. Auto-pause function - unplugging the external probe automatically suspends alarm & statistics processing. Record inspections at the push of a button. Interchangeable External Probe with high quality gold plated connector. Comprehensive customisation options including alarm settings, sample interval and trip duration The LogTag TREL30-16 cryogenic temperature data logger is excellent for monitoring & recording freezers, blood plasma, vaccines, pharmaceutical and more over a range of -80 C to +40 C (-112 F to +104 F) via external probe. The TREL30-16 can store up to 15,900 temperature records enough memory for 66 days at 6 minute logging. The display is designed to show At A Glance if temperature excursions have occurred during the current day and up to the previous 29 days. The display also shows the current temperature reading, the current time, recording status and battery status. The alarm is trigged if temperature readings are outside pre-set alarm limits. The status indicator changes from a to a X and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option. Details of any excursions in the preceding 30 days can be checked directly by inspecting the statistics history on the recorder s display or in more detail by downloading the logged data via a standard LogTag Interface cradle to LogTag Analyzer operating software. CATALOG NO. LTTREL3016 Product Model External Sensor Measurement Range Operating Temperature Range Storage Temperature Range Rated Temperature Reading Accuracy Rated Temperature Reading Resolution Sampling Interval Logging Start Options Recording Indication Download Time Environmental Power Source 8 Battery Life Real Time Clock Standard Remote Sensor Cable Length Remote Sensor Cable Type Size Weight Case Material Temperature Data Logger - 15.9K logs w/probe Note: LTIUSB (USB Interface Cradle) required for operation TREL30-16 (Replaceable Battery). -80 C to +40 C (-112 F to +104 F). -20 C to +40 C (-22 F to +104 F). -10 C to +55 C (14 F to +131 F). Better than ±1.0 C for -30 C to +20 C Better than ±1.2 C for -45 C to -30 C and +20 C to +40 C. Better than ±1.7 C for -80 C to -45 C Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart above. Accuracy figures can be improved by recalibration. Less than 0.1 C for -80 C to 0.0 C Less than 0.2 C for 0.0 C to +20 C Less than 0.5 C for +20 C to +40 C Please see the Rated Native Resolution chart above. LogTag Analyzer currently displays to one decimal place of C or F. The native resolution is what is stored in the LogTag. Configurable from 30 seconds to hourly. Push button start or specific date & time. Optional start delay of up to 18 hours. State indicator REC". Typically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used. IP61 (when vertically mounted or hung). 3V CR2032 (LiMnO2) coin cell battery, user replaceable. Typically 1 year of operation. NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time. Download data monthly. NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible. Built-in real time clock. Rated accuracy ±25ppm @ 25 C (equivalent to 2.5 seconds/day). Rated temperature coefficient is -0.034 ±0.006ppm/ C I.e typically +/- 0.00294 seconds/day/ C). Standard: 1.5m (4 11"). Extended: 3m (9 10") (Recommended maximum). PTFE (FDA food contact rated), coaxial. 93mm(H) x 54.5mm(W) x 8.6mm(T). 41g without External Probe. Polycarbonate.

LogTag Dry Ice Probe-Less Low Temperature Recorder The LogTag Dry Ice Probe-less Temperature Recorder operates, measures and stores up to 8000 temperature readings in temperature environments ranging from -80 C to +40 C (-112 F to +104 F) Intended for use in transit monitoring of articles stored in packaging incorporating dry ice cooling. Available in single trip (SRIL-8) and multiple trip (TRIL-8) versions. Using the LogTag Interface Cradle and the freely available companion software LogTag Analyzer, these are easily set-up for recording conditions including delayed start, sampling interval, number of readings, continuous or fixed number of readings and configuration of conditions to activate the 'ALERT' indicator. The Red Alert indicator provides an immediate indica tion, without access to a PC, if any readings are outside the limits specified at the time the unit was configured. Green OK indicator provides immediate visual confirma tion, without access to a PC, that the unit is operating. LogTag Analyzer also provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel once the data has been downloaded. The product incorporates an external temperature sensor uniquely arranged in a recess in the case. This arrangement protects the sensor from physical damage while retaining the faster response time normally associated with remote sensors. CATALOG NO. LISRIL8 Recorder Operating Range Temperature Accuracy Temperature Resolution Capacity Sampling frequency Download Time Environmental Power source Battery life / Endurance Size Weight Case Material Interface & software Single use Dry Ice Probe-Less Low Temperature Recorder -80 ~ +40 C (-112 F ~ +104 F) Better than ±1 C for -30 C~ +20 C better than ±1.2 C for -45 C~ -30 C & +20 C~+40 C better than ±1.7 C for -80 C~-45 C Less than 0.1 C for -80 C ~ 0.0 C less than 0.2 C for 0.0 C ~+20 C less than 0.5 C for +20 C ~+40 C 8000 temperature readings (16Kbytes memory) Adjustable, 1min to several hours Typically with full memory in less than 5 seconds depending on computer or readout device used. IP65 3V low temperature chemistry Lithium battery. Minimum storage life of 12 months before start. Single use version rated for a typical trip of 2 weeks duration at dry ice temperatures. Multi-use version is rated for up to a total accumulative exposure of 1000hrs @ -80 C across multiple trips. 86mm(H)x54.5mm(W)x8.6mm(T) 35grams Polycarbonate Operates with standard LogTag Interface cradles Requires LogTag Analyzer 2.2r20 or later. 9

HiTemp 135 Autoclave Temperature Data-Logger HiTemp 135 is a rugged, high precision, temperature data logger that is built for use in harsh environments. This stainless steel device is submersible, can withstand temperatures up to 140 C (284 F) and has an accuracy of +/-0.1 C (0.18 F) over the entire operating range. The HiTemp135 can store up to 32,700 readings, and features a 2 rigid external probe capable of measuring extended temperatures, up to 260 C (500 F). Also the device records date and time stamped readings, and has non-volatile solid state memory that will retain data even if the battery becomes discharged. Using the Thermco Software, starting, stopping and downloading the HiTemp135 is simple and easy. Graphical, tabular and summary data is provided for analysis and data can be viewed in C, F, K or R. The data can also be automatically exported to Excel for further calculations. ±0.1 C (0.18 F) Accuracy Operates Up To 140 C (284 F) Submersible (IP68) NIST Traceable User Replaceable Battery Rugged Programmable start time Programmable stop time Engraved Label Probe Lengths Up To 7 Battery Life Indicator BENEFITS: Simple Setup and Installation Minimal Long-Term Maintenance Long-Term Field Deployment APPLICATIONS: Autoclave Verification Implement HACCP Programs Food Preparation and Processing Environmental Studies Well Monitoring Dishwasher Testing Pasteurization CATALOG No. ACCHITEMP135 ACCHITEMP135PT High Temperature Data Logger with a 2 probe High Temperature Data Logger with 24 Flex probe ACCESSORIES: ACCTIFC400 Docking station with USB cable, software and manual ACCHITEMPBAT-2 Replacement battery for the ACCHITemp135 MGNIST NIST Calibration Certificate Temperature Sensor : 100Ω Platinum RTD Probe Measurement Range : -200ºC to +260ºC (-328ºF to +500ºF) Temperature Resolution : 0.01ºC (0.02ºF) Calibrated Accuracy : ±0.1ºC/±0.18ºF (-20ºC to +140ºC/-4ºF to +284ºF) Software programmable immediate start Start Modes : Delay start up to eighteen months in advance Manual through software Stop Modes : Timed (specific date and time) Real Time Recording : May be used with PC to monitor and record data in real time An optional password may be programmed into the device to restrict access to Password Protection : configuration options. Data may be read out without the password. Memory : 32,700 readings Wrap Around : Yes Reading Rate : One second up to once every 24 hours Battery Type : 3.6v high-temperature lithium battery included; user replaceable Battery Life: 1 year typical (1 minute reading rate at 25ºC/77ºF) Calibration : Digital calibration through software Calibration Date : Automatically recorded within device Data Format : Date and time stamped ºC, ºF, K, ºR Time Accuracy : ±1 minute/month at 20ºC to 30ºC (68ºF to 86ºF) (Stand alone mode) Computer Interface : IFC 400 USB docking station required 125,000 baud Software ; XP SP3/Vista/Windows 7 Operating Environment ; -20ºC to +140ºC (-4ºF to +284ºF), 0%RH to 100%RH Dimensions (Body) : 2.7 x 0.97 dia. (67mm x 25mm dia.) Dimensions (Probe**) : 2 x.188 to.125 transitional dia. 50mm x 3.8mm to 3.2mm transitional dia. Weight : 4.2 oz (120g) Material : 316 Stainless Steel 10

CRYO TEMP -80 - Data Logger Ultra Low Temperature Data Logger, records temperatures as low as 80C. The Cryo-Temp 80 can be used in a broad line of applications such as monitoring blood plasma, vaccines, pharmaceuticals, frozen foods and shipping containers. This standalone device does not require any additional probes. The enclosure is designed with a handle for easy attachment and is IP64 splash resistant. It utilizes a USB docking station (sold separately), to communicate with a personal computer or laptop. The Cryo-Temp 80 provides date and time stamped temperature readings and uses the Thermco Data Logging Software. The user can view the data in graphical or tabular form. High and low alarm limits and high and low warning limits can be programmed through the software. The user can set the alarm limits in the range required for the goods to be maintained. The warn limits can be set to alert the user when the temperature is nearing a high or low alarm limit, so that proper action can be taken to ensure the integrity of the goods. The Cryo-Temp 80 is equipped with three LED s. The green LED will blink every 15 seconds while the recorder is logging data. The yellow LED will blink every 3 seconds when the temperature has breached the warning limits. The red LED will blink every 3 seconds when the temperature alarm limits have been exceeded. The Cryo-Temp 80 is the ideal temperature monitoring solution for any application involving ultra low temperature data logging. CATALOG No. ACCCRY086 MGNIST ACCTIFC300 Cryo-Temp 80 Data Logger Certificate Traceable to NIST, 1 Temperature Docking Station, USB Cable, Data Logger Software - XP SP3 / Vista/ Windows 7, and Manual Temperature Sensor: NTC Thermistor Temperature Range: -86 C to +35 C recommended, may be used up to +55 C Temperature Resolution: 0.1 C Calibrated Accuracy: ±1.0 C Reading Rate: 5 seconds to 30 minutes, selectable in software Start Modes: Software programmable immediate start, delay start up to 30 days in advance or manual start with magnetic switch Temperature Alarm: Software programmable high and low alarm limits, high and low warn limits each setpoint may be individually enabled or disabled Alarm Delay: Software programmable time delay for warn/alarm limits. Logger will not indicate out of range status until the temperature has been out of range for a for a set period of time. Green- Blinks to indicate safe conditions during logging Status Indicators: Yellow- Blinks to indicate warn limits have been exceeded Red- Blinks to indicate alarm criteria (limits/delay) have been exceeded Password Protection: An optional password may be programmed into the device to restrict access to configuration options. Data may be read out without the password. Calibration: Digital calibration through software Calibration Date: Automatically recorded within device Battery Type: 3.6V lithium battery (LTC-7PN), factory replaceable only Battery Life: 2 years typical @ 25 C, 1 min. reading intervals 1 year typical @ 80 C, 1 min. reading intervals Data Format: Date and time stamped ºC, ºF, K, ºR Time Accuracy: ±2 minutes/month max. at 20 to 30 C ±5 minutes/month max at 80 C Computer Interface: USB docking station to PC (IFC300) 38,400 baud Software: Vista/Win 7 8 10 Operating Environment: -86 C to +35 C (may be used up to +55 C); 0 to 100% RH Dimensions: 3.3 x 2.1 x 0.4 (83 mm x 54 mm x 11 mm) Ingress Protection/IP: IP65 (splash resistant, not submersible) Enclosure: ABS plastic, white, polycarbonate labeling Weight: 1.4 oz (40 g) 11

LogTag Humidity & Temperature Recorder NIST Traceable w/certificate Alert indicator indicates if readings are outside of preset limits OK indicator indicates if still recording and if readings within configured limits Inspection mark in log by push button Push Button Logging start with optional delayed start or specific Time & Date start Rapid Download! Takes only seconds to download recordings Fine resolution of measurement 0.1%RH & 0.1 C/ F Pre-Start logging - Logtag can be configured to record even if it has not been started. High performance at low cost Credit card sized case thin enough to be easily mailed letter rate. Real time clock records time & temperature simultaneously Easy to use LogTag Analyzer software that runs on any PC configures LogTag for recording then downloads resulting data for analysis. Data can also be exported to fomats compatible with other applications such as MS Excel Re-calibration to achieve higher accuracy possible Replaceable sensor air filter The LogTag Humidity & Temperature Recorder measures and stores up to 8000 sets of high resolution humidity and temperature readings over 0 to 100%RH & -40 C to +85 C (-40 F to +185 F) measurement ranges. Using the LogTag Interface and LogTag s freely available companion software LogTag Analyzer, the LogTag is easily set-up for recording conditions including delayed start, sampling interval, number of readings, continuous or fixed number of readings and configuration of conditions to activate the ALERT indicator. Readings are downloaded using LogTag Analyzer, which provides facilities for charting, zooming, listing data statistics and allows exporting the data to other applications such as MS Excel. CATALOG NO. LTHAXO8 LTISOLOGRH LTIUSB LTBRACKET 0 ~ 100%RH but with limitations as detailed in Humidity Measurement Operating and Storage conditions below Humdity Measurement Range Temperature Measurement Range -40 ~ +85 C (-40 ~ +185 F) Wall Mount Bracket The LogTag Wall Mount Bracket provides an easy and tidy solution to mounting a LogTag on a wall,door. Interface Cradle Logtag s unique interface cradle design provides rapid and reliable LogTag data transfer to Logtag Analyzer software in a matter of seconds Data Logger Temperature and Humidity note: LTIUSB (USB Interface Cradle) required for operration Temp Humidity Certification for LTHAX08 USB Interface Cradle Wall Mount Bracket Resolution 0.1%RH & 0.1 C/ F Capacity 8000 pairs of humidity & temperature readings (32Kbytes memory) Sampling frequency adjustable, 30 sec to several hours Logging start options Push button start or specific date & time. Recording indication Flashing OK indicator flashing Alert indicator. Typically with full memory (8000 pairs of readings) in less than 10 Download Time seconds depending on computer or readout device used. Environmental IP61 (when hung or mounted vertically) Power source 3V Lithium battery 2 ~ 3 years of normal use (based on 15 minute logging, download data Battery life monthly) Size 86mm(H) x 54.5mm(W) x 8.6mm(T) Weight 35g Case Material Polycarbonate 12

USB Temperature/Humidity Data Logger with Display HICSSN-22 Data Logger is the perfect tool for stand alone or coldchain monitoring and documentation of temperature and relative humidity conditions that are critical in laboratories, pharmaceutical, medical, storage, freezers, coolers, shipping containers, warehouses, environmental monitoring and food storage applications. The HICSSN-22 can measures and record up to 16K temperature readings over -35 to +80 C (-31 to +176 F) and 16K relative humidity measurement from 0 to 100%RH. The integral USB connector easily plugs into a computer for quick data analysis using the included DGraph software. Real time monitoring of temperature and humidity values are displayed in the integrated LCD screen. The data logger is supplied complete with a long-life lithium battery, which can allow logging for over 2 years, and configuration software, compatible with Windows XP / Vista / 7&8. CATALOG No. HICSSN-22 NIST22 USB Temp/Humidity Data-Logger w/display NIST Certification for HICSSN-22 1 Temperature / 2 Humidity Relative Humidity Temperature Measurement range: 0~100%RH -35~80 C (-31~176 F) Accuracy: ±3%RH ±0.3 C (±0.5 F) Resolution: 0.1%RH typically 0.1 C (0.2 F) Long Term Drift: <0.5%RH per year Negligible Number of Channels: Memory Capacity: Sample Rate: Operating Range: Alarm: 2 Channels...humidity and temperature 64KBytes (total 32,000 readings for all channels) Can be selected from 10 seconds to 12 hours 0 to 100%RH, -35 to 80 C (-31 to 176 F) User programmable high or low alarm limit for each channel LEDs: PC Software: Power: Battery Life: Case Material: Weight: Size: Red & Green LED: Logger Status indication.. Delay to Start, Logging, Alarm, Finished Yellow LED: Low battery indication DGraph software and USB driver Included on CD Compatible with Windows XP, Vista, 7&8 (32 bit & 64 bit) User replaceable 1/2AA 3.6V Lithium Battery Note: USB can supply power directly if necessary Approx. 2 years @ 1 Minute Sample Rate Approx. 4 years @ 10 Minute Sample Rate Approx. 8 years without any sample task ABS 60g / 2.3oz 12.5 * 4.3 * 2.7cm / 4.9 * 1.7 * 1.1in 13

MICRO-THERM Temperature USB Data Logger Temperature & RH USB Data Logger ACCD00408 Back of ACCD00408RH MICRO-THERM USB Data Loggers are small, rugged, waterproof and dust proof devices with LCD Display and built-in USB 2.0 connector for monitoring and recording temperature and/or RH. Manufactured to stringent standards, the MICRO-THERM loggers are only 4.3 long and 1 thick. The data loggers features a three digit LCD display, direct USB connection, wide temperature range, high accuracy and large 8K or 32K sampling memory. Features include analysis functionality such as Statistics Maximum, Minimum and Average, enabling a quick glance summary of the environment and historical analysis. Data can be displayed on the small numeric LCD screen or downloaded to PC via the USB 2.0 connector. To further ensure easy global usage, the battery is easily replaceable since it is a standard model used worldwide. Typical applications for this product include food, pharmaceutical, medical, storage and transportation industries. NIST Compliant w/certificate Range -40 to 80ºC, (-40 to 176ºF) High Resolution 16-Bit Logger High Accuracy 0.3 C High Sampling Rate of 1 per Second High functionality low cost multi-trip logger for an unbroken cold chain USB 2.0 interface for fast track communication and firmware updates Unique Boomerang feature that automatically creates and emails PDF data report when logger is connected to PC Rapid data download to Graph, Table view and Excel spreadsheet Built-in LCD with decimal point readings and LED alarm indicator High accuracy sensors with 16-bit resolution 2-year battery life, using Nano Watt Technology Up to 8,000 & 32,000 sample memory accommodating long-haul transports Reed switch using magnet key to mark time stamps, activate and stop logging Built-in real-time clock and calendar Dust and water proof Cradle wall mounting for fixed monitoring Includes Mirco-Therm Lite Software and Manual Range: Accuracy: Resolution (16-bit): CATALOG No. ACCD00408 ACCD00408RH -40 to 80 C Temp 0.3 C Temp 0.1 C (Display) 0.06 C (Software) -40 to 80 C Temp 5 to 95 % RH 0.3 C Temp 2% RH 0.04 C (Display) 0.06 C (Software) RH: 0.5% Data Capacity: 8,000 Samples 32,000 Samples Sampling Rate: 1 per second to 1 every 2 Hours 1 per second to 1 every 18 Hours Boomerang Feature: No Yes Alarms: None LED Indicator Battery Life: ~ 1.5 Years ~ 2.0 Years Dimensions with Cap: 11cm x 3.9cm x 2.6cm (4.3 x 1.5 x 1.0 ) 11cm x 3.9cm x 3.0cm (4.3 x 1.5 x 1.2 ) Compliance: IP68, EN12830, CE IP54, EN12830, CE Wall Mount: No Yes Outputs: Weight: Display: Indicator: Battery: Software: USB 2.0 interface 45.5 grams (1.6oz) 3-digit 7-segment LCD with decimal point Low battery Warning Replaceable 3V Lithium Battery - CR2032 Micro-Therm Lite for Windows (Included) LCD Display: When exposed to temperatures below 5 F (-15 C) Liquid Crystal Displays (LCD) lose contrast and their refresh rate slows. This may result in illegible readings shown on the display. The decline of the LCD function does not affect the sensor recording temperature and the correct values are captured. 14

Low Cost USB Cold Chain Data-Logger Portable, Low Cost, Disposable Low cost, one-trip, disposable logger for an unbroken cold chain Internal, high accuracy temperature sensor Unique Boomerang feature that automatically creates and emails PDF data report when logger is connected to PC Direct USB interface for PC communication 16,000 sample memory accommodating long-distance transports Software-enabled activation button to start logging and mark time stamps Built-in bi-color LED for logging and immediate alarm indication Supported by the complimentary DataSuite software for data analysis and alarm notification Up to 6-month battery life depending on operating conditions Water and dust resistant IP67 Effective cold chain processes require control over the quality of perishable goods and compliancy with the highest industry standards. The compact and easy-to-use disposable PicoLite USB data logger provides a simple solution for temperature monitoring, throughout mass transportation cold chain processes. Featuring a built-in temperature sensor, activation button, bi-color LED and direct USB connectivity, the PicoLite offers a plug and record solution for every application. The PicoLite is configured by using the intuitive DataSuite software, offering comprehensive data analysis features and alarm notifications. By reducing overhead related to more complex multi-trip loggers, the PicoLite meets the challenge of combining low cost with reliability for one-trip, value-for-money data logging. CATALOG No. ACCDPICOLITE SPECIFICATIONS : Temperature Range -40 C to 40 C Accuracy 0.5 C LED Indicator PicoLite Cold Chain Data-Logger Bi-color LED for sampling and alarm indication PC Communication USB 2.0 compliant Sample Memory 16,000 samples Sampling Rate Once minute to once every 18 hours Battery Life / Type Up to 6 months depending on operating conditions / CR2032 Dimensions 74 mm x 30 mm x 13 mm Weight 15 g Compliance CE, EN12830, IP67 DataSuite Software for PicoLite DataSuite is a modular software platform, simultaneously supporting multiple fourtec monitoring solutions: Software GUI based on proven fourtec platforms Multiple data view features Alarm features with 2 alarm levels, sending email and SMS notifications Reporting module for creating and generating reports with selected distribution Analysis features including histogram and statistics with export to Excel and CSV formats Supported Operating Systems: Windows XP SP3 / Vista / 7 (32 and 64 Bit) Minimum Hardware Requirements: Pentium 4.2 GHz Processor or better, 512 MB RAM, 250 MB available disk space 15

Thermco Products Inc. 10 Millpond Drive - Unit #10 Lafayette, NJ 07848 Phone: 973.300.9100 Fax: 973.255.1000 Email: Info@ThermcoProducts.com www.thermcoproducts.com