AIRABLO 1050 rue acadie, Victoriaville, Québec, Canada G6T1R3 Phone Fax:

Similar documents
MODEL INSTALLATION INSTRUCTIONS SEWAGE PUMP

MODEL E

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

SUPPLEMENTARY INSTRUCTIONS

Version /08/2018 USER MANUAL VACUUM FILTER PRESS. All rights reserved Les Équipements d Érablière CDL inc.

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

Model T Professional Series 3/4HP 2 YEAR WARRANTY SEWAGE PUMP

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

OPERATION & MAINTENANCE INSTRUCTIONS

SUBMERSIBLE DIRTY WATER PUMP

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

2 - Hood DESCRIPTION CABLE HOLDER PG16 WITH HOLE PLUG FOR DOOR (BR-BC-FC) SLIDING WASHER TIE ROD FC

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

FCHRT. Wash arm Rinse arm Tank HR. Rinse E-HR-HRT. Rinse aid injector Control box with electronic printed circuit Detergent dispenser

MODEL CMA-130VL PARTS MANUAL Rev 1.00

MODEL INSTALLATION INSTRUCTIONS GRINDER PUMP

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

Lubi Submersible Condensate Removal Pumps

LC Series - Light Commercial Pump Station Installation and Operation Manual

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

Domestic Pump Condensate Transfer Equipment

SELF-CLEANING EXTRACTORS

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

WATER PUMP REQUESTED INFORMATION STANDARD PROCEDURE RAM Pickup 6.7L Eng 2500 STANDARD PROCEDURE - COOLANT AIR EVACUATION

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

ES Series Electric Humidifier

GF Hood / Tank. Wash arm Wash/Rinse column. Thermostat/solenoid valve group Control box Rinse aid injector. Drain pump

Family Curve. Submersible Grinder Pumps 1¼" and 2" Discharge. Effluent/Grinder Pumps.

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

IMAGE V. Parts and Service Manual

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

OWNERS GUIDE TO INSTALLATION AND OPERATION

NEPTUNE 2. Model: NEPTUNE 2-13 NEPTUNE 2-20 NEPTUNE 2-25 NEPTUNE 2-26 NEPTUNE 2-30 NEPTUNE 2-33 NEPTUNE 2-38 NEPTUNE Part List US-English

AIR OPERATED CLUTCH & BRAKE BLEEDING KIT. MODEL NO: CHT637 Part No: OPERATING & MAINTENANCE INSTRUCTIONS GC01/12

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

KLE-235D DOUBLE RACK IN-LINE CONFIGURATION KLE-175GTM SINGLE RACK THREE-DOOR CONFIGURATION KLE SERIES ULTRA WASH DISHMACHINE INSTRUCTION MANUAL

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

MAXUM 5 5 Gallon Box Extractor

TYPE POS Oil Shield Sump Pump

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

TERMINATOR 120V CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

5. CONDENSATE PUMPS/UNITS

APW PSI PRESSURE WASHER

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

Condensate Boiler Feed Water Make-Up

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

CH250 AND CH251 CHILLERS

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

SPECIFICATIONS FEATURES

CHILLER. Operator s & Installation Manual

Models Series Series

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

Electric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

Heat Exchanger Piping Hook-up

Hot Water Circulator Pump LRP

Models Series Series

MODEL 664A MODEL 662A MODEL 663A MODEL 661A AURORA. 660 Series SINGLE STAGE SOLIDS HANDLING VORTEX PUMPS

SINCE Base Mounted Pump. Series 2000/

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ

FLANGE-MOUNT CENTRIFUGAL PUMPS

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

INSTALLATION INSTRUCTIONS

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Models: FM FM WARNING

EXTREME 1 Reverse Osmosis System

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Intructions manual. User friendly Hygienic Reliable

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

Wilo IL Vertical Split-Coupled Inline Pumps

EXTREME 4 Reverse Osmosis System

CHILLER. Model CH3000. Operator s & Installation Manual

5HP CYCLONE DUST COLLECTOR MANUAL

WHIRL-A-WAY OPERATIONS MANUAL

RPI Industries, Inc.

USER MANUAL/Installation Instructions LRV-4

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

Family Curve. Submersible Grinder Pumps 1¼" and 3" Discharge. Effluent/Grinder Pumps.

INSTALLATION INSTRUCTIONS WARRANTY

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

Global-Tek (Singapore) Pte Ltd

ProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11

SECTION STEAM CONDENSATE PUMPS

2 - Hood DESCRIPTION CABLE HOLDER FOR BHC SLIDING WASHER TIE ROD FC SLIDING PLATE F. TIE ROD DOOR CATCH BR-BC-FC DOOR CATCH B-F-R

Transcription:

Anti- particle filter... 2 Clear cover... 17 Curve at 0hg pump 1hp... 7 Curve at 0hg pump 2hp... 13 Dimension pump 1hp... 8 Electrical box part... 16 Electrical drawing... 15 Exploded view pump 2hp... 10 Guarantee... 6 Hook-up requirements... 2 How does it work... 2 Installation... 2 Maintenance... 2 Part list pump 2hp... 12 Releaser clip... 17 Sectional drawing pump 2hp... 11 Technical data pump 1hp... 9 Technical data pump 2hp... 14 Troubleshooting... 3, 4, 5, page 1

Congratulations! Your choice proves of your liking for high technology equipment and well designed machines. Indeed you have purchased one of the most advanced technology equipment, carefully built in accordance with the highest standards of the industry. It will be of service a long time with its various applications. However, we advise you read and follow scrupulously the following instructions. How does it work Once sap level reaches the desired height, the electrode activates the switch to start the pump. After the sap is pumped-out, the electrode at the middle stops the pump Installation -The extractor should be installed where ambient temperature is at least 1 deg C. Otherwise, the reservoir will need to be drained everyday. -Extractor need to be levelled properly Hook-Up Requirements -Vacuum pump to be selected according to number of taps. -Use PVC or ABS pipe. Size depending on vacuum pump (1 ½,2,2 ½,3 ) -Vacuum regulator must be installed between vacuum pump & extractor. -For oil cooled pumps only, a humidity/sap trap must be installed between vacuum pump & extractor for protection against flooding & avoid sugar build-up. Maintenance Pre-season: -Inspect: switch, cracks, mobile parts, hoses, fittings & clamps -Lubricate float rod, covers gaskets, etc... During season: -Remove clear covers and clean entire extractor thoroughly with dish soap and water solution. -Rinse -Drain water pump to avoid freezing -Avoid heating source near-by plastic components Anti-particle filter: Your releaser is equipped with a plate anti-particle filter. A regular verification of the filter is necessary in order to prevent foreign material obstruction., page 2

Troubleshooting -Problem: Sap reservoir stays full --> check for leaks/cracks, fittings,check valve -Problem: Pump will not start --> check vacuum pump switch by activating manually, page 3

Troubleshooting AIRABLO 1050 rue acadie, Victoriaville, Québec, Canada G6T1R3, page 4

Troubleshooting AIRABLO 1050 rue acadie, Victoriaville, Québec, Canada G6T1R3, page 5

GUARANTEE: Your releaser is guaranteed by the manufacturer against any fabrication defects for a 2 year period if used in maple industry. The manufacturer's responsibility regarding this guarantee is restricted in replacing the parts as he pleases or doing the repairs. All the parts that are changed under guarantee become the property of the manufacturer. The manufacturer would not be responsible for any damage resulting from carelessness, abuse or non respect of the operating instructions, or injuries inflicted to an individual., page 6

Curve at 0hg pump 1hp, page 7

Dimension pump 1hp, page 8

Technical data pump 1hp The motor is a 1-phase motor with sand shield, liquid-lubricated bearings and pressure equalizing diaphragm. Liquid: Maximum liquid temperature: 104 F Max liquid t at 0.15 m/sec: 104 F Technical: Speed for pump data: 3450 rpm Rated flow: 26.4 US GPM Shaft seal for motor: LIPSEAL Approvals on nameplate: CE,EAC,CSACOMP,UR Materials: Pump: DIN W.-Nr. 1.4301 Motor: Stainless steel DIN W.-Nr. 1.4301 AISI 304 Installation: Pump outlet: 1 1/2"NPT Motor diameter: 4 inch Capacity: At 20hg At 0psi = 25gpm At 25psi = 24gpm At 50psi = 19gpm At 80psi = 0gpm 25hg At 0psi = 20gpm At 25psi = 18gpm At 50psi = 16gpm At 80psi = 0gpm 27hg At 0psi = 18gpm At 25psi = 16gpm At 50psi = 14gpm At 75psi = 0gpm, page 9

Exploded view pump 2hp, page 10

Sectional drawing pump 2hp, page 11

Part list pump 2hp AIRABLO 1050 rue acadie, Victoriaville, Québec, Canada G6T1R3, page 12

Curve at 0hg pump 2hp, page 13

Technical data pump 2hp Multi-stage submersible pump for sap water The pump is made entirely of Stainless steel DIN W.-Nr. DIN W.-Nr. 1.4301. Liquid: Maximum liquid temperature: 104 F Technical: Speed for pump data: 3450 rpm Curve tolerance: ISO 9906:2012 Grade 3B Materials: Pump: Stainless steel DIN W.-Nr. 1.4301 AISI 304 Impeller: Stainless steel DIN W.-Nr. 1.4301 AISI 304 Installation: Pump outlet: 1 1/2"NPT Motor diameter: 4 inch Electrical data: Power (P2) required by pump: 2.33 HP Capacity: At 20hg At 0psi = 50gpm At 25psi = 45gpm At 50psi = 40gpm At 75psi = 0gpm 25hg At 0psi = 48gpm At 25psi = 45gpm At 50psi = 35gpm At 72psi = 0gpm 27hg At 0psi = 48gpm At 25psi = 45gpm At 50psi = 30gpm At 70psi = 0gpm, page 14

Electrical drawing AIRABLO 1050 rue acadie, Victoriaville, Québec, Canada G6T1R3, page 15

Electrical box part AIRABLO 1050 rue acadie, Victoriaville, Québec, Canada G6T1R3 1 01155461 PUSH BUTTOM SCHNEIDER 2 01155436 SELECTOR 3 POSITIONS SCHNEIDER 3 01155438 CONTACT NO CLAMP SWITCH SCHNEIDER 4 01155437 ADAPTOR BASE SWITCH SCHNEIDER 5 01155404 CONTACTOR LC1D18 240VAC SCHNEIDER 6 01155460 ELECTROD LEVEL CONTROL SCHNEIDER 7 01155254 TERMINAL BLOCK 22-6 AWG CTS10U 8 01155250 TERMINAL BLOCK FUSE 22-10 AWG CSFL4U 8 01155348 ELECTROD LEVEL CONTROL SCHNEIDER 9 01155248 TERMINAL BLOCK 22-12 AWG CTS2.5U-N 10 01155261 TERMINAL BLOCK END STOP CA802 * 01155009 BOX HOFFMAN POLYPRO NEMA 4X 10X8X4 * 01150922 STAINLESS BACK PLATE 8.75" * 6.88", page 16

01250360 BELLEY RELEASER 22" PLEXIGLASS COVER AFTER 2012 01250345 BLUE RELEASER 1HP AND 2HP O-RING 01280056 ZINC CLIP FOR BOOSTER 7721058 ADJUSTABLE ZINC CLIP 3.8" * 4.7" CAP 600 01250340 ADJUSTABLE STAINLESS CLIP 3.8" * 4.7" CAP 600, page 17