Healthcare Title Solutions

Similar documents
Hospitality Title Solutions

Office Title Solutions

Education Title Solutions

Restaurants IECC 2015 Solutions

Restaurants ASHRAE Solutions

Code Review TITLE PRESENTED BY POURIA NIKNAM

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

Here we see the list of auto shutoff controls we will cover in the next few slides

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

24 Volt DC Edition EMerge Alliance Registered Products

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

TITLE 24 ICONOGRAPHY. Iconography System

California Title Design Guide for Smart Lighting Control and Energy Solutions

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

CRESTRON GREEN LIGHT ARCHITECTURAL DIMMING CONTROLS (GLPD)

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Wireless Lighting Control Made Easy

Indoor Controls. SpaceWise SWZG2. Wireless technology

ANSI/ASHRAE/IES

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

WSA120: New Energy Codes and Lighting Controls

ANSI/ASHRAE/IES

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

SECTION LIGHTING CONTROLS

Crestron Zūm. Wireless lighting control made easy

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Lighting Control Strategies. to meet code requirements save energy and improve building performance

LIGHTING CONTROLS

visual environment technologies etcconnect.com

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

ASHRAE October 18, 2013

Applied Lighting Controls

C-Bus Application Note. Function Rooms and Ballrooms. Overview

CHV-TSTAT-FCU Heating and Cooling Fan-Coil Thermostat. Supplemental Guide Crestron Electronics, Inc.

Sensors and Detectors

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

A. This Section includes the following lighting control devices:

Code Compliance Commercial Application Guide

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

IN2 Lighting Control Devices

visual environment technologies etcconnect.com

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

CLS-EXP-DIM. Functional Summary. Specifications

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

Mini Product Guide.

Ever evolving energy code requirements and the large demand for energy

2015 IECC. Design Guide for Smart Lighting Control and Energy Solutions

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

Wireless Indoor Lighting Control System

A Guide for Applicants and Lighting Designers

C-Bus Application Note. Standard Meeting Room. Overview

LIGHTING CONTROL DEVICES

LIGHTING CONTROLS. Smart Enough to Work Right Out of the Box

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014

Application Guide to CA Title 24

0ACDT2000MV Ultasonic/Infared Occ Sensor

Wireless Plug Load Control

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

COMcheck Software Version Interior Lighting Compliance Certificate

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

ENERGY EFFICIENCY EXPERTS

CRESTRON MEDIAMANAGER INTELLICLASS

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Distributed Low-Voltage Power System. design and application guide

A. This Section includes the following lighting control devices:

Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Product Comparison Guide

1. Section [ Lighting Control Panel Boards:] Lighting panels (switching) controlled by ControlKeeper

Versatile wall switch sensors maximize payback and simplify code compliance

SECTION LIGHTING CONTROL DEVICES

Lighting Solutions for Active Workspaces

Reduce lighting energy costs with controls

Product Specifications Dialog Room Controller* (*patent pending)

The Power To Supply... All Your Electrical Products

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

Emery County Senior Center Green River 06/07

From the Originator and Leader in Integrated Motion Sensor Controls

Design and Commissioning of Lighting Control Systems. Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012

The Power To Supply... All Your Electrical Products

Hubbell Controls Application Guide to CA Title 24 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

Lighting Control Solutions for Parking Facilities

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

Supporting the Requirements of EPAct 2005 Tax Deductions

IECC. nlight Applications Guide.

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

ARCHITECTURAL DIMMING PANEL - MAIN/SECONDARY

C-Bus Application Note. Themed Venue. Overview

Transcription:

Healthcare Solutions Design Guide Crestron Electronics, Inc.

Contents About 1 Design Guide Information 1 Code Standards 2 Operating Room 4 GLDALI... 4 GLPAC... 5 Patient Room / Exam Room 6 GLDALI... 6 GLPAC... 7 Lobby 8 Zūm... 8 GLPP... 9 GLPAC + DMX... 10 Private Office 11 Zūm... 11 GLPP... 12 Corridor 13 Zūm... 13 GLPP...14 Public Restroom 15 Zūm...15 GLPP...16 i crestron.com Doc. 8296A

About is a residential and commercial building energy code that is designed to reduce energy consumption. The goal of this code is to reduce energy consumption by providing design and construction requirements for lighting controls. Lighting controls such as occupancy status sensors, multi-level controls, and demand response provisions allow you to synchronize indoor light levels with daylight levels in accordance with. Design Guide Information Crestron offers this Design Guide for Healthcare - solutions to use as a reference for typical layouts. Use it as guidance to make code compliance quick and easy. The Crestron team is also available to support with detailed design, submittal, and installation requirements. For additional information, please contact your Crestron representative at CLCDesign@crestron.com or (888) 330-1502. Doc. 8296A crestron.com 1

Code Standards Summary Code Standards Code Provision Minimum Requirement Code Description ON/OFF CONTROLS LIGHT LEVEL CONTROL 130.1(a) 1 control. Each space and area enclosed by ceiling-height partitions Luminaires must be controlled with accessible manual on/off local must be independently controlled. 130.1(b) Multi-Level 130.1(c) 2 130.1(c)5/6/7 Sensor Lighting of any enclosed area 100 square feet or larger with more than one luminaire and a load >0.5 watts per square foot should provide multi-level lighting control that meets uniformity requirements in accordance with Title24 Table 130.1-A. Lighting control can not override local on/off or any other control requirements. Lighting must be controlled by either 1) an occupant sensing control, 2) automatic time-switch control with 2 hour maximum override and holiday scheduling, or 3) other control capable of automatically shutting off lighting. Indoor shut-off zones must be separated using ceiling high partitions and can be no larger than one floor with a maximum of 5,000 sq. ft. Occupant Sensing s are required to shut off all lighting. Full or partial off to at least 50% via occupant sensing controls is required. 130.1(d) Daylight Zones 3 in all daylit zones as defined by 130.1(d). Lighting controls should have multilevel functionality to at least the number of control steps Automatic daylighting controls should be installed and configured defined in Title 24 Table 130.1-A. 130.1(e) Demand Response Ready 4 Buildings >10,000 square feet with a lighting power density 0.5 watts per square foot are required to receive a standards-based messaging protocol, which automatically reduces lighting power by at least 15% and remains consistent with uniform illumination requirements defined in Title 24 Table 130.1-A. PLUG LOAD CONTROL 130.5(d) led Receptacles 50% of receptacles are required to automatically turn off based on occupancy or after a vacancy of 20 minutes or less. Each uncontrolled receptacle must have at least one controlled receptacle within 6 feet. Primary Solutions Zūm Wireless Light GLPP GLPAC GLDALI 1. General lighting must be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, track, ornamental, and special effects lighting should be separately controlled and placed on circuits that are 20 amps or less. 2. Countdown timer switches should not be used to comply with the automatic shut-off control requirements in Section 130.1(c)1, except in single-stall bathrooms and closets that are <70 square feet where the lights must shut off within ten minutes, or in a server aisle/room where the lights must shut off within 30 minutes. 3. The photosensor should be readily accessible to authorized personnel for calibration adjustments. To prevent unauthorized access, the photosensor may be mounted inside a case that is secured with a locking mechanism. 4. Add a networked Crestron control system for demand response (130.5(d)) control. For networked Zūm applications, add a ZUM-FLOOR-HUB and ZUMNET-GATEWAY for demand response. 2 crestron.com Doc. 8296A

Space Type Small Private Office 250 sq. ft. Public Restroom Corridor Lobby Patient / Exam Room Imaging / Operating Room Doc. 8296A crestron.com 3

Operating Room GLDALI Multi-Level Demand Response Ready Local : DALI Cresnet Daylight zones (130.1(d)) may be required if windows are present. Symbol Qty. Product Description 1 GLDALI DIN-EN-3x18, RMC3, DIN-DALI-2, DIN-BLOCK, DIN-PWS60, CEN-SW-POE-5 2 C2N-CBD-P Cameo Keypad, Standard Mount 4 crestron.com Doc. 8296A

Operating Room GLPAC Multi-Level Demand Response Ready Local : 0-10 V Pwr & Ctrl Cresnet Daylight zones (130.1(d)) may be required if windows are present. Symbol Qty. Product Description 1 GLPAC-DIMFLV8-4E Green Light Integrated Lighting System, 2 Isolated 4-Channel Outputs, UL924 Listed 2 C2N-CBD-P Cameo Keypad, Standard Mount Doc. 8296A crestron.com 5

Patient Room / Exam Room GLDALI Multi-Level Daylight Zones (130.1(d)) Demand Response Ready Local : 18/3 Cresnet DALI Symbol Qty. Product Description 1 GLDALI DIN-EN-3x18, RMC3, DIN-DALI-2, DIN-BLOCK, DIN-PWS60, CEN-SW-POE-5 3 C2N-CBD-P Cameo Keypad, Standard Mount 1 GLS-LOL Crestron Green Light Photosensor, Open-Loop 1 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor, 2000 sq. ft. 6 crestron.com Doc. 8296A

Patient Room / Exam Room GLPAC Multi-Level Daylight Zones (130.1(d)) Demand Response Ready Local : 18/3 Cresnet 0-10 V Pwr & Ctrl Symbol Qty. Product Description 1 GLPAC-DIMFLV8-4E Green Light Integrated Lighting System, 2 Isolated 4-Channel Outputs, UL924 Listed 3 C2N-CBD-P Cameo Keypad, Standard Mount 1 GLS-LOL Crestron Green Light Photosensor, Open-Loop 1 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor, 2000 sq. ft. Doc. 8296A crestron.com 7

Lobby Zūm Multi-Level Daylight Zones (130.1(d)) Demand Response Ready Zūm Net Wireless Zūm Mesh Wireless 18/3 0-10 V Pwr & Ctrl led receptacle (130.5(d)) may be required if receptacles are present. Local : Symbol Qty. Product Description 4 ZUMMESH-JBOX-5A-LV Junction Box Zone ler, 0-10V Dimming, 5A 1 ZUMMESH-JBOX-SIM Zūm Junction Box Sensor Integration Module 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 2 ZUMMESH-KP10CBATT 6-Button Battery-Powered Keypad 2 GLA-IR-QUATTRO-COM1-24 High Definition PIR Presence Detector, Ceiling Mount, Square & Scalable 360 Coverage, 18-24 VAC/VDC 1 GLS-LOL Crestron Green Light Photosensor, Open-Loop 8 crestron.com Doc. 8296A

Lobby GLPP Multi-Level Daylight Zones (130.1(d)) Demand Response Ready 0-10 V Pwr & Ctrl 18/2 18/4 led receptacle (130.5(d)) may be required if receptacles are present. Local : Product Qty. Product Description 1 GLPP-1DIMFLV3-CN-PM 3-Ch 0-10V Dimmer with Cresnet 2 GLPPA-KP In-Wall Keypad for GLPP 1 GLA-IR-QUATTRO-COM1-24 High Definition PIR Presence Detector, Ceiling Mount, Square & Scalable 360 Coverage, 18-24 VAC/VDC 1 GLS-LOL Crestron Green Light Photosensor, Open-Loop Doc. 8296A crestron.com 9

Lobby GLPAC + DMX Multi-Level Daylight Zones (130.1(d)) Demand Response Ready 0-10 V Pwr & Ctrl 18/3 DMX Ethernet led receptacle (130.5(d)) may be required if receptacles are present. Local : Product Qty. Product Description 1 GLPAC-DIMFLV4 Green Light Integrated Lighting System, 4-Channel 1 DIN-EN-3x18 RMC3, DIN-SCAN-DMX, CEN-POE-SW5 1 TSW-760 7 Touch Screen 2 GLA-IR-QUATTRO-COM1-24 High Definition PIR Presence Detector, Ceiling Mount, Square & Scalable 360 Coverage, 18-24 VAC/VDC 1 GLS-LOL Crestron Green Light Photosensor, Open-Loop 10 crestron.com Doc. 8296A

Private Office Zūm Multi-Level Sensor (130.1(c)5/6/7) Demand Response Ready led Receptacle (130.5(d)) Zūm Net Wireless Zūm Mesh Wireless 0-10 V Pwr & Ctrl Daylight zones (130.1(d)) may be required if windows are present. Local : Symbol Qty. Product Description 1 ZUMMESH-5A-LV Zūm Wall-Box Dimmer, 5A 1 ZUMMESH-JBOX-20A-PLUG Zūm J-Box Load ler, Plug Load Switch 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 1 ZUMMESH-PIR-VACANCY-BATT PIR Vacancy Sensor (AUTO-OFF) Doc. 8296A crestron.com 11

Private Office GLPP Multi-Level Sensor (130.1(c)5/6/7) Demand Response Ready led Receptacle (130.5(d)) 18/2 18/4 0-10 V Pwr & Ctrl Daylight zones (130.1(d)) may be required if windows are present. Local : Symbol Qty. Product Description 1 GLPP-DIMFLVCN-PM 1-Ch 0-10V Dimmer with Cresnet 1 GLPP-SWCN Crestron Green Light Power Pack, 1-Channel Switch with Cresnet 1 GLPPA-KP In-Wall Keypad for GLPP 1 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor, 2000 sq. ft. 12 crestron.com Doc. 8296A

Corridor Zūm Multi-Level Sensor (130.1(c)5/6/7) Demand Response Ready Zūm Net Wireless Zūm Mesh Wireless 18/3 0-10 V Pwr & Ctrl UL924 emergency lighting devices are available for life safety. Daylight zones (130.1(d)) may be required if windows are present. Lighting installed in a corridor should meet the following requirements in addition to complying with Section 130.1(c)1: The corridor should be controlled by occupant sensing controls that separately reduce the lighting power by at least 50 percent when the corridor is unoccupied. The occupant sensing controls should be capable of automatically turning the lighting fully on only in the separately controlled corridor, and should be automatically activated from all designed paths of egress. Lighting installed in a common area corridor that provides access to guest rooms and dwelling units should comply with 130.1(c)7: Common area corridors must be controlled with occupant sensing controls that automatically reduce lighting power in unoccupied areas by at least 50 percent. The occupant sensing controls should be capable of automatically turning the lighting fully on only in the separately controlled corridor, and should be automatically activated from all designed paths of egress. When the installed lighting power is 80 percent or less of the value allowed under the Area Category Method, occupant sensing controls should reduce the power by at least 40 percent. Local : Symbol Qty. Product Description 1 ZUMMESH-JBOX-5A-LV Junction Box Zone ler, 0-10V Dimming, 5A 1 ZUMMESH-JBOX-SIM Zūm Junction Box Sensor Integration Module 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 1 ZUMMESH-KP10ABATT Rocker-Button Battery Powered Keypad 1 GLA-US-HALLWAY-COM1-24 40 khz Ultrasonic Presence Detector, Ceiling Mount, Hallway Coverage, 18-24 VAC/VDC Doc. 8296A crestron.com 13

Corridor GLPP Multi-Level Sensor (130.1(c)5/6/7) Demand Response Ready 0-10 V Pwr & Ctrl 18/3 18/2 UL924 emergency lighting devices are available for life safety. Daylight zones (130.1(d)) may be required if windows are present. Lighting installed in a corridor should meet the following requirements in addition to complying with Section 130.1(c)1: The corridor should be controlled by occupant sensing controls that separately reduce the lighting power by at least 50 percent when the corridor is unoccupied. The occupant sensing controls should be capable of automatically turning the lighting fully on only in the separately controlled corridor, and should be automatically activated from all designed paths of egress. Lighting installed in a common area corridor that provides access to guest rooms and dwelling units should comply with 130.1(c)7: Common area corridors must be controlled with occupant sensing controls that automatically reduce lighting power in unoccupied areas by at least 50 percent. The occupant sensing controls should be capable of automatically turning the lighting fully on only in the separately controlled corridor, and should be automatically activated from all designed paths of egress. When the installed lighting power is 80 percent or less of the value allowed under the Area Category Method, occupant sensing controls should reduce the power by at least 40 percent. Local : Product Qty. Product Description 1 GLPP-1DIMFLVCN-PM 1-Ch 0-10V Dimmer with Cresnet 1 GLPPA-KP In-Wall Keypad for GLPP 1 GLA-US-HALLWAY-COM1-24 40 khz Ultrasonic Presence Detector, Ceiling Mount, Hallway Coverage, 18-24 VAC/VDC 14 crestron.com Doc. 8296A

Public Restroom Zūm Multi-Level Demand Response Ready led Receptacle (130.5(d)) Local : Zūm Mesh Wireless Zūm Net Wireless 0-10 V Pwr & Ctrl 18/3 Public restrooms with two or more stalls may use a manual control not accessible to unauthorized personnel. Daylight zones (130.1(d)) may be required if windows are present. Public restrooms should have at least one control step between 30-70 percent of full rated power. Symbol Qty. Product Description 2 ZUMMESH-JBOX-5A-LV Junction Box Zone ler, 0-10V Dimming, 5A 1 ZUMMESH-JBOX-SIM Zūm Junction Box Sensor Integration Module 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 1 ZUMMESH-KP10ABATT Rocker-Switch Battery Powered Keypad 2 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor Doc. 8296A crestron.com 15

Public Restroom GLPP Multi-Level Demand Response Ready led Receptacle (130.5(d)) Local : 0-10 V Pwr & Ctrl 18/4 18/2 Public restrooms with two or more stalls may use a manual control not accessible to unauthorized personnel. Daylight zones (130.1(d)) may be required if windows are present. Public restrooms should have at least one control step between 30-70 percent of full rated power. Product Qty. Product Description 1 GLPP-1DIMFLV2CN-PM 2-Ch 0-10V Dimmer with Cresnet 1 GLPPA-KP In-Wall Keypad for GLPP 2 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor 16 crestron.com Doc. 8296A

Notes Doc. 8296A crestron.com 17

Notes 18 crestron.com Doc. 8296A

Crestron, the Crestron logo, 3-Series, Cresnet, Crestron Green Light, Cameo, Zūm are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. This document was written by the Technical Publications department at Crestron Electronics, Inc. 2018 Crestron Electronics, Inc. Doc. 8296A crestron.com 19

Crestron Electronics, Inc. 15 Volvo Drive, Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Design Guide Doc 8296A (2051452) 10.18 Specifications subject to change without notice