Energy Codes. Connected Lighting simplified by Eaton. design and application guide

Similar documents
Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

WaveLinx Wireless Connected System

Distributed Low-Voltage Power System. design and application guide

ASHRAE October 18, 2013

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Connected Buildings Sales positioning guide

ANSI/ASHRAE/IES

WSA120: New Energy Codes and Lighting Controls

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

ANSI/ASHRAE/IES

TITLE 24 ICONOGRAPHY. Iconography System

A. The wireless lighting control system shall be capable of providing all of the following functions for all lighting:

Connected Buildings Sales positioning guide

Code Review TITLE PRESENTED BY POURIA NIKNAM

IECC. nlight Applications Guide.

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

A Guide for Applicants and Lighting Designers

Mini Product Guide.

visual environment technologies etcconnect.com

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Hospitality Title Solutions

1. Section [ Lighting Control Panel Boards:] Lighting panels (switching) controlled by ControlKeeper

Restaurants IECC 2015 Solutions

visual environment technologies etcconnect.com

design and application guide LumaWatt Pro powered by Enlighted

Codes and Controls Commercial Building Energy Code Requirements for Light Control. Michael Jouaneh, CEM, LEED AP September 20, 2012

Education Title Solutions

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

LumaWatt Pro Wireless Connected Lighting System powered by Enlighted

Healthcare Title Solutions

WaveLinx Outdoor Wireless Connected Lighting System

Lighting Application Guide for K-12 Classrooms

Restaurants ASHRAE Solutions

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

Wireless Lighting Control Made Easy

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

Lighting Controls An Introduction and Review

Office Title Solutions

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Indoor Controls. SpaceWise SWZG2. Wireless technology

Are LED s ready for Prime Time?

2015 IECC. Design Guide for Smart Lighting Control and Energy Solutions

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

California Title Design Guide for Smart Lighting Control and Energy Solutions

Code Compliance Commercial Application Guide

Reduce lighting energy costs with controls

LIGHTING CONTROLS

ilumin Plus design and application guide

Here we see the list of auto shutoff controls we will cover in the next few slides

Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

Power. Eaton is a registered trademark. All other trademarks are property of their respective owners.

Application Guide to CA Title 24

Wireless Indoor Lighting Control System

Applied Lighting Controls

Lighting Control Solutions for Parking Facilities

Decoding 2016 Title 24, Part 6

Retrofitting Billingsley Company office spaces in Dallas, TX

FROM THE WORLD S FIRST GFCI RECEPTACLE TO OUR GAME-CHANGING LINE OF PASS & SEYMOUR PLUGTAIL DEVICES, PASS & SEYMOUR PRODUCTS HAVE A REPUTATION FOR

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

PRESCRIPTIVE APPROACH

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

Wireless Plug Load Control

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

Versatile wall switch sensors maximize payback and simplify code compliance

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

LIVMODERN LIVMODERN RPT. Elegant linear LED fixture PART NUMBER BUILDER 10VDIM 0-10VDIMMABLE 3000K 4000K 24IN 36IN 48IN 1800LM* 3000LM** 3500LM***

Ceiling PIR HS presence detector. Product Guide. Overview. Features

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

ENERGY EFFICIENCY EXPERTS

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

UNIVERSAL LIGHTING OFFERS BREAKTHROUGHS FOR BOTH ANALOG AND DIGITAL DIMMING APPLICATIONS

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

Savings, control, and comfort without complexity

Design and Commissioning of Lighting Control Systems. Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012

VESICA LINEAR SUSPENDED VES L

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

From the Originator and Leader in Integrated Motion Sensor Controls

4SNLEDLD548SLUNV 4snledld548slunvl840cd1u

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

ARCHITECTURAL DIMMING PANEL - MAIN/SECONDARY

2017 Michigan Energy Code Changes Electrical Provisions-Commercial Michigan Energy Code Training and Implementation Program

Supporting the Requirements of EPAct 2005 Tax Deductions

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Advanced Lighting Solutions

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

ESL-IC Smart Room Control

Best practices in lighting design to comply with California s Title 24 energy code

Transcription:

Codes Connected simplified by Eaton design and application guide

We make connections work* Eaton Power Connectivity Apps * Simplif ied connected lighting solutions for Buildings, Communities & omes Eaton s portfolio of connected lighting solutions leverages the realestate of the physical light fixture to increase building, business and community operating efficiency through controls and data. With connected lighting solutions, we go beyond controlling light to solve higher complexity problems enabled by sensing and communication capabilities within the light fixture itself. With innovation you can rely on, and connections you can build on; that s how Eaton makes connections work. www.eaton.com/connected

Table of Contents Codes ASI / ASRAE / IES Standard 90.06 4 International Conservation Code (IECC) 05 4 California Title 4 4 Application code compliant sequence best practices 67 Terminology 89 WaveLinx applications & typical wiring diagrams WaveLinx overview 0 IECC 05 Classroom examples Conference room examples 34 Office corridor example 5 Private office example 6 Lobby example 7 Open office example 8 Restaurant example 9 Retail example 0 ASRAE 90. 06 Classroom examples Conference room examples 34 Office corridor example 5 Private office example 6 Lobby example 7 Open office example 8 Restaurant example 9 Retail example 30 DLVP applications & typical wiring diagrams DLVP overview 4 Classroom, x fixtures with integrated sensors 4 Classroom, x fixtures 43 Classroom, x4 fixtures with integrated sensors 44 Classroom, x4 fixtures 45 Conference room, x fixtures with integrated sensors 46 Conference room, x fixtures 47 Conference room, x fixtures and downlights 48 Corridor/all, x4 fixtures with integrated sensors 49 Corridor/all, x4 fixtures 50 Executive office, x fixtures 5 Open office, x4 fixtures with integrated sensors and emergency 5 Open office, x4 fixtures with integrated sensors 53 Open office, x4 fixtures 54 Open office, x4 fixtures with integrated sensors and emergency 55 Private office, x4 fixtures with integrated sensors 56 Private office, x4 fixtures 57 Private offices, x4 fixtures with integrated sensors 58 TITLE 4 06 Classroom examples 33 Conference room examples 3334 Office corridor example 35 Private office example 36 Lobby example 37 Open office example 38 Restaurant example 39 Retail example 40

Codes application notes ASI / ASRAE / IES Standard 90.06 Standard for Buildings Except LowRise Residential Buildings (Standard 90.06) adopted as of September 06. This code significantly finetunes the design requirements for codecompliant lighting controls systems, mechanical systems, and the building envelope. This application note summarizes the new mandatory lighting control requirements and highlights where they can be used in various spaces. Please note: this document is intended to provide a general reference and design professionals should consult Standard 90.03 and the authority having jurisdiction for projectspecific requirements and interpretation. Below summarizes changes from 90.03 to 90.06: Reduced occupancysensor time delay from 30 to 0 minutes Requires partialoff to 50% in spaces where lights should remain O, such as corridors and stairwells Requires daylight controls in primary, secondary and top light zones Requires functional testing requirements ASRAE 90. was recognized by the U.S. Department of (DOE) as the national energy reference standard. International Conservation Code (IECC) 05 IECC 05 establishes minimum energy efficiency requirements for new and renovated buildings. This latest iteration contains dramatic changes to the prescriptive and performancebased criteria that previously defined IECCcompliant lighting and lighting control systems. ASRAE 90. is recognized by the DOE as the national reference standard, however IECC is adopted by many states. Please note: this document is intended to provide a general reference and design professionals should consult IECC 05 and the authority having jurisdiction for projectspecific requirements and interpretation. Below summarizes changes from 0 to 05: s Revamped and Redefined Continuous Dimming ow Required in Certain Daylit Spaces Reduce Exterior Lights at ight Use a Digital System to Satisfy Additional Efficiency Options ew Commissioning Documents Deadline California Title 4 California's Building Efficiency Standards are updated on an approximately threeyear cycle. The 06 Standards will continue to improve upon the 03 Standards for new construction of, and additions and alterations to, residential and nonresidential buildings. The effective date of the 06 Standards is January, 07. Below summarizes changes from 03 to 06: Mandatory controls eliminates power adjustment factors Simplify multilevel lighting controls Clarify partialo and partial requirements Clarified alterations controls requirements 4 EATO Connected Codes

saving lighting control strategies STRATEGY DESCRIPTIO ESTIMATED SAVIGS dimming control is one of five methods that satisfy the multilevel lighting control requirements. 00% /vacancy control turns lights Off (or partially Off) when a room is unoccupied. Lights can be turned On automatically or manually, when a person enters a room. 060% control automatically adjusts lighting levels in response to the amount of daylight available in the space. 045% O/ Auto O/ or Vacancy Mode is designed to ensure that lighting does not turn O automatically. 40%60% ighend tuning lowers the maximum light level, creating energy savings. 030% reduces light levels in response to a signal from an OpenADR device or BMS closure. 040% ly Switched O/ ly switched O/ method allows users to manually control the lighting within the space and complies with local control requirements. 00% Plug load control turns controlled receptacles On, when the space is occupied, and Off, when the space is vacant. 550% led loads UL94 ( Backup Circuit) The ability to control emergency lighting along with normal lighting while ensuring they go to full bright during normal power loss. 530% EATO Connected Codes 5

Application code compliant sequence best practices ASRAE 90. 06 IECC 05 T4 06 Atrium Banking Classroom / Training / Lecture Conference / Meeting room Local 9.4.(a)..3 (a), O 9.4...3 (a), O 9.4.(c).. Bilevel 9.4. Side lighting 9.4.(e).3. Top lighting 9.4.(f).3. 9.4.(g).. (c).6 Full 9.4.(h).. (c).5 Shutoff 9.4.(i).. (c) 8.4..4 30.5 8.4.3. 30.5 Parking Garage 9.4..5 (a), 9.4.3 C408..3 (a), (a), Enhanced Digital s C406.4 Required Choose one Choose one Choose one 6 EATO Connected Codes

Copy / Print room Corridor Courtroom Dining area Food preparation Library Office Restroom Sales area Stairwell Required Choose one Choose one Choose one EATO Connected Codes 7

Terminology IGLEVEL TERMIOLOGY Local control If the controlled space is 0,000 ft, a control device shall not control more than 500 ft If the controlled space is larger than 0,000 ft, no device shall control more than 0,000 ft The installed device shall be readily accessible and the load being controlled shall be visible when operating the control RECOMMEDED PRODUCTS* WaveLinx DLVP Room ler System Fifth Light Wallbox dimmers/sensors GDS when connected to LiteKeeper, Keeper Restricted to O Vacancy modes must be used such that lights will not turn on automatically WaveLinx DLVP Room ler System Fifth Light VSW, VW, VLW VAC Restricted to O When in occupancy mode, automatic O shall not exceed 50% of the lighting power WaveLinx DLVP Room ler System Fifth Light LiteKeeper/, Keeper Bilevel The general lighting in a space must have the following functionality: Full O, Full, and Dimming Dimming may be continuous or through step dimming If step dimming, at least one intermediate step shall be between 30% and 50% of full lighting power WaveLinx DLVP Room ler System Fifth Light LiteKeeper, Keeper OAC, OAWC with Low Voltage Switches Responsive s for Sidelighting Primary sidelighted areas with combined input power at 50W or greater shall be controlled by photocontrols Secondary sidelighted areas with combined input power at 300W or greater, the area shall be controlled by photocontrols s must also: be readily accessible for calibration, control primary and secondary sidelighted areas independently, and shall incorporate daylight dimming WaveLinx DLVP Room ler System Fifth Light Analog Photosensors with Keeper daylight responsive controls for toplighting Space within any daylight area that has combined input power for all general lighting at 50W or greater shall be controlled by photocontrols. must: Be readily accessible for calibration adjustments ave daylight response through continuous dimming or Step dimming with a point between 50% and 70%, a point between 0% and 40% (or lowest dimming level that the technology permits), and a third point at full off General lighting with overlapping toplighted and sidelighted areas shall be controlled together WaveLinx DLVP Room ler System Fifth Light Analog Photosensors with Keeper partial (full complies) Within 0 minutes of occupants leaving a space, lighting power shall automatically decrease at least 50% WaveLinx DLVP Room ler System Fifth Light Keeper * Additional product combinations may be code compliant. Please contact your Eaton s Systems representative for more information. Exceptions: more detailed information may apply, please reference your local code for more detailed information. 8 EATO Connected Codes

Terminology IGLEVEL TERMIOLOGY RECOMMEDED PRODUCTS* full Within 0 minutes of occupants leaving a space,lighting shall be automatically shut Each control shall not control more than 5000 ft WaveLinx DLVP Room ler System Fifth Light LiteKeeper, Keeper Wallbox and Ceiling s Shutoff When a space is scheduled to be vacant, lighting shall be automatically shut. Any override control shall revert back to the schedule within hours of the last action WaveLinx DLVP Room ler System Fifth Light LiteKeeper, Keeper ally turn off plug loads when the space is unoccupied by sensor or time schedule WaveLinx DLVP Room ler System Fifth Light LiteKeeper, Keeper Provide energy measurement data on the system collected at a minimum of every 5 minute and reported at least hourly WaveLinx (included with system) Fifth Light (included with system) PowerXpert (external measurement for all other systems) EATO Connected Codes 9

WaveLinx Wireless Connected System Wireless, codecompliant, and costeffective, WaveLinx Wireless Connected System offers the most outofthebox functionality on the market. It s also one of the easiest connected lighting systems to install and manage. code compliance? Yes, it s true code commissioning meets or exceeds code requirements Wireless integrated sensors ensure maximum efficiency and flexibility A simple mobile app allows building managers to easily adjust settings, even after the project has finished, with no need to go back into the wall Connected fixtures provide a platform for future scalability Wireless, codecompliant, and costeffective for today 0 EATO Connected Codes

IECC 05 IECC 05: Classroom example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads dimming zones of no more than eight luminaires Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy Wireless Area ler Qty Catalog # Description Wireless Area ler WSPMV00 WaveLinx Relay Switchpack with 00V dimming CWPD500 WaveLinx ceiling sensor W4SRLW WaveLinx 4ELD34UVL835CDSWPDU Encounter x4 not required for indoor spaces without windows ot required in spaces without windows or that are less than 50W s Programmable scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler 50 feet 00 feet to st WaveLinx device Distance between WaveLinx devices 75 feet 50 feet umber of hops from 4 hops 5 hops Wireless Area ler umber of areas per 6 6 Wireless Area ler umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless 00V CWPD500 Wireless Ceiling occupancy sensor x4 recessed light fixture with 00V dimming WSPMV00 0A Relay w/ 00V Dimming Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 EATO WaveLinx design and application guide

IECC 05 IECC 05: Classroom example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx on to 50% Optional vacancy mode Optional plug load turns on/off with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces ot required in spaces without windows that are less than 50W s Programmable scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup Complies with Enhanced Digital section C406 PoE etwork Switch provided by others Wireless Area ler WLRLW Wireless large button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 EATO WaveLinx design and application guide

IECC 05 IECC 05: Conference room example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows or that are less than 50W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx TMSWPD WaveLinx Tilemount 3 LD4 OR LD6 Portfolio Commercial Recessed LED 4 ELD34UVL835CDSWPDU Encounter x with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup Complies with Enhanced Digital section C406 PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V ELD34UVL835CDSWPDU Encounter x with WaveLinx LD4/LD6 Portfolio Commercial Recessed LED Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 EATO WaveLinx design and application guide 3

IECC 05: Conference room example IECC 05 ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Individually addressable luminaires Out of the box 75% high end trim auto on to 50% Optional vacancy mode Optional plug load turns on/off with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor space without windows ot required in spaces without windows or that are less than 50W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx TMSWPD WaveLinx Tilemount 3 LD4 OR LD6 Portfolio Commercial Recessed LED DSIWS3L35DUVAC48T8STDSWW Divide Suspended with WaveLinx s Programmable Scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup Complies with Enhanced Digital section C406 PoE etwork Switch provided by others Wireless Area ler DSIWS3L35DUVAC48T8STDSWW Divide Suspended 8ft with WaveLinx Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler 50 feet 00 feet to st WaveLinx device Distance between WaveLinx devices 75 feet 50 feet umber of hops from 4 hops 5 hops Wireless Area ler umber of areas per 6 6 Wireless Area ler umber of zones per area 3 6 W4SRLW Wireless 4 small button scene wallstation TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V LD4/LD6 Portfolio Commercial Recessed LED umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 4 EATO WaveLinx design and application guide

IECC 05: Office corridor example IECC 05 ly Switched O/ Lumen Maintenance O/ Auto Wireless Area ler 00V lighting loads Individually addressable luminaires Out of the box 75% high end trim auto on to 50% Optional vacancy mode Optional plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces without windows ot required in spaces without windows or that are less than 50W Qty Catalog # Description Wireless Area ler WLRLW WaveLinx 6 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Programmable Scenes Dominant button is 50% light level on/off Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler WLRLW Wireless large button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 EATO WaveLinx design and application guide 5

IECC 05 IECC 05: Private office example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows or that are less than 50W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx ELD34UVL835CDSWPDU Encounter x with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup Complies with Enhanced Digital section C406 PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation ELD34UVL835CDSWPDU Encounter x with WaveLinx Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 6 EATO WaveLinx design and application guide

IECC 05: Lobby example IECC 05 ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor space without windows ot required in spaces without windows or that are less than 50W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx TMSWPD WaveLinx Tilemount 6 LD4 OR LD6 Portfolio Commercial Recessed LED ELD34UVL835CDSWPDU Encounter x with WaveLinx s Dominant button half lights (sets lights to 50% or less) Programmable scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup Complies with Enhanced Digital section C406 PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V ELD34UVL835CDSWPDU Encounter x with WaveLinx LD4/LD6 Portfolio Commercial Recessed LED Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 EATO WaveLinx design and application guide 7

IECC 05 IECC 05: Open office example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Optional plug load turns on/off with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor space without windows ot required in spaces without windows or that are less than 50W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SLRLW WaveLinx 4 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup Complies with Enhanced Digital section C406 PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 8 EATO WaveLinx design and application guide

IECC 05 IECC 05: Restaurant example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Individually addressable luminaires Out of the box 75% high end trim on to 50% Optional vacancy mode Optional plug load turns on/off with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor space without windows ot required in spaces without windows or that are less than 50W Wireless Area ler Qty Catalog # Description Wireless Area ler 5 W4SLRLW WaveLinx 4 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup Complies with Enhanced Digital section C406 PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 EATO WaveLinx design and application guide 9

IECC 05 IECC 05: Retail example ly Switched O/ Lumen Maintenance O/ Auto Linear Dimming Module WaveLinx Relay 00V 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Optional plug load turns on/off with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor space without windows ot required in spaces without windows or that are less than 50W Wireless Area ler Qty Catalog # Description Wireless Area ler 6 W4SLRLW WaveLinx 4 WSPMV00 WaveLinx Relay Switchpack with 00V dimming 4 LDCMPL07700VGR Linear Dimming Modules 3 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup Complies with Enhanced Digital section C406 PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls W4SRLW Wireless 4 small button scene wallstation 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 WSPMV00 0A Relay w/ 00V Dimming LDCMPL0 7700VGR Linear Dimming Module Local O O Bilevel Side Top Parking Garage Enhanced Digital IECC 05..3..3...3..3........4.5.3 C406. 4 0 EATO WaveLinx design and application guide

ASRAE 90. 06 ASRAE 90. 06: Classroom example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy not required for indoor spaces without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx WSPMV00 WaveLinx Relay Switchpack with 00V dimming CWPD500 WaveLinx ceiling occupancy sensor 4ELD34UVL835CDSWPDU Encounter x4 s Programmable scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler 50 feet 00 feet to st WaveLinx device Distance between WaveLinx devices 75 feet 50 feet umber of hops from 4 hops 5 hops Wireless Area ler umber of areas per 6 6 Wireless Area ler umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless 00V CWPD500 Wireless Ceiling occupancy sensor x4 recessed light fixture with 00V dimming WSPMV00 0A Relay w/ 00V Dimming Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 EATO WaveLinx design and application guide

ASRAE 90. 06 ASRAE 90. 06: Classroom example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor space without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx 4ELD34UVL835CDSWPDU Encounter x4 with Istinct s Programmable scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet WR5 Wireless umber of hops from Wireless Area ler 4 hops 5 hops umber of areas per Wireless Area ler 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 EATO WaveLinx design and application guide

ASRAE 90. 06 ASRAE 90. 06: Conference room example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx TMSWPD WaveLinx Tilemount 3 LD4 OR LD6 Portfolio Commercial Recessed LED 4 ELD34UVL835CDSWPDU Encounter x with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless ELD34UVL835CDSWPDU Encounter x with WaveLinx TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V LD4/LD6 Portfolio Commercial Recessed LED Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 EATO WaveLinx design and application guide 3

ASRAE 90. 06 ASRAE 90. 06: Conference room example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Up to 3 dimming zones Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor space without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx TMSWPD WaveLinx Tilemount 6 LD4 OR LD6 Portfolio Commercial Recessed LED DSIWS3L35DUVAC48T8STDSWW Divide Suspended with WaveLinx s Programmable Scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler DSIWS3L35DUVAC48T8STDSWW Divide Suspended 8ft with WaveLinx Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS WR5 Wireless umber of interior walls walls 3 walls Distance from Wireless Area ler 50 feet 00 feet to st WaveLinx device Distance between WaveLinx devices 75 feet 50 feet umber of hops from 4 hops 5 hops Wireless Area ler umber of areas per 6 6 Wireless Area ler umber of zones per area 3 6 W4SRLW Wireless 4 small button scene wallstation TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V LD4/LD6 Portfolio Commercial Recessed LED umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 4 EATO WaveLinx design and application guide

ASRAE 90. 06: Office corridor example ASRAE 90. 06 ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim Wireless Area ler auto on to 50% Optional vacancy mode Optional plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows or that are less than 0W Qty Catalog # Description Wireless Area ler W4SLRLW WaveLinx 6 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Programmable Scenes Dominant button is 50% light level on/off Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 EATO WaveLinx design and application guide 5

ASRAE 90. 06 ASRAE 90. 06: Private office example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx ELD34UVL835CDSWPDU Encounter x with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless ELD34UVL835CDSWPDU Encounter x with WaveLinx Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 6 EATO WaveLinx design and application guide

ASRAE 90. 06: Lobby example ASRAE 90. 06 ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor space without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx TMSWPD WaveLinx Tilemount 6 LD4 OR LD6 Portfolio Commercial Recessed LED ELD34UVL835CDSWPDU Encounter x with WaveLinx s Dominant button half lights (sets lights to 50% or less) Programmable scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler 50 feet 00 feet to st WaveLinx device Distance between WaveLinx devices 75 feet 50 feet umber of hops from 4 hops 5 hops Wireless Area ler umber of areas per 6 6 Wireless Area ler umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless ELD34UVL835CDSWPDU Encounter x with WaveLinx TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V LD4/LD6 Portfolio Commercial Recessed LED Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 EATO WaveLinx design and application guide 7

ASRAE 90. 06: Open office example ASRAE 90. 06 ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SLRLW WaveLinx wallstation WR5 WaveLinx 4 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet WR5 Wireless umber of hops from Wireless Area ler 4 hops 5 hops umber of areas per Wireless Area ler 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 8 EATO WaveLinx design and application guide

ASRAE 90. 06 ASRAE 90. 06: Restaurant example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces without windows ot required in spaces without windows that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler 5 W4SLRLW WaveLinx WR5 WaveLinx 4 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet WR5 Wireless umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 EATO WaveLinx design and application guide 9

ASRAE 90. 06 ASRAE 90. 06: Retail example ly Switched O/ Lumen Maintenance O/ Auto Linear Dimming Module WaveLinx Relay 00V 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces without windows ot required in spaces without windows that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler 6 W4SLRLW WaveLinx 4 WSPMV00 WaveLinx Relay Switchpack with 00V dimming WR5 WaveLinx 4 LDCMPL07700VGR Linear Dimming Modules 3 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls W4SRLW Wireless 4 small button scene wallstation 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 WR5 Wireless WSPMV00 0A Relay w/ 00V Dimming LDCMPL0 7700VGR Linear Dimming Module umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage ASRAE 90.06 9.4. (a) (c) (e) (f) (g) (h) (i) 8.4. 8.4.3. 9.4.. 9.4.3 30 EATO WaveLinx design and application guide

TITLE 4 06 TITLE 4 06: Classroom example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy not required for indoor spaces without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx WSPMV00 WaveLinx Relay Switchpack with 00V dimming CWPD500 WaveLinx ceiling occupancy sensor 4ELD34UVL835CDSWPDU Encounter x4 s Programmable scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler 50 feet 00 feet to st WaveLinx device Distance between WaveLinx devices 75 feet 50 feet umber of hops from 4 hops 5 hops Wireless Area ler umber of areas per 6 6 Wireless Area ler umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless 00V CWPD500 Wireless Ceiling occupancy sensor x4 recessed light fixture with 00V dimming WSPMV00 0A Relay w/ 00V Dimming Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) EATO WaveLinx design and application guide 3

TITLE 4 06 TITLE 4 06: Classroom example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Programmable scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet WR5 Wireless umber of hops from Wireless Area ler 4 hops 5 hops umber of areas per Wireless Area ler 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) 3 EATO WaveLinx design and application guide

TITLE 4 06 TITLE 4 06: Conference room example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx TMSWPD WaveLinx Tilemount 3 LD4 OR LD6 Portfolio Commercial Recessed LED 4 ELD34UVL835CDSWPDU Encounter x with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless ELD34UVL835CDSWPDU Encounter x with WaveLinx TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V LD4/LD6 Portfolio Commercial Recessed LED Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) EATO WaveLinx design and application guide 33

TITLE 4 06 TITLE 4 06: Conference room example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Up to 3 dimming zones Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx TMSWPD WaveLinx Tilemount 6 LD4 OR LD6 Portfolio Commercial Recessed LED DSIWS3L35DUVAC48T8STDSWW Divide Suspended with WaveLinx s Programmable Scenes Dominant button is 50% light level Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler DSIWS3L35DUVAC48T8STDSWW Divide Suspended 8ft with WaveLinx Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS WR5 Wireless umber of interior walls walls 3 walls Distance from Wireless Area ler 50 feet 00 feet to st WaveLinx device Distance between WaveLinx devices 75 feet 50 feet umber of hops from 4 hops 5 hops Wireless Area ler umber of areas per 6 6 Wireless Area ler umber of zones per area 3 6 W4SRLW Wireless 4 small button scene wallstation TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V LD4/LD6 Portfolio Commercial Recessed LED umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) 34 EATO WaveLinx design and application guide

TITLE 4 06: Office corridor example TITLE 4 06 ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim Wireless Area ler auto on to 50% Optional vacancy mode Optional plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces without windows ot required in spaces without windows or that are less than 0W Qty Catalog # Description Wireless Area ler WLRLW WaveLinx 6 4ELD34UVL835CDSWPDU Encounter x with WaveLinx s Programmable Scenes Dominant button is 50% light level on/off Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler WLRLW Wireless large button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) EATO WaveLinx design and application guide 35

TITLE 4 06 TITLE 4 06: Private office example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx ELD34UVL835CDSWPDU Encounter x with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless ELD34UVL835CDSWPDU Encounter x with WaveLinx Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) 36 EATO WaveLinx design and application guide

TITLE 4 06: Lobby example TITLE 4 06 ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim auto on to 50% Optional vacancy mode Plug load turns on with occupancy / Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces without windows ot required in spaces without windows or that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SRLW WaveLinx WR5 WaveLinx TMSWPD WaveLinx Tilemount 6 LD4 OR LD6 Portfolio Commercial Recessed LED ELD34UVL835CDSWPDU Encounter x with WaveLinx s Dominant button half lights (sets lights to 50% or less) Programmable scenes Scene raise Scene lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls Distance from Wireless Area ler 50 feet 00 feet to st WaveLinx device Distance between WaveLinx devices 75 feet 50 feet umber of hops from 4 hops 5 hops Wireless Area ler umber of areas per 6 6 Wireless Area ler umber of zones per area 3 6 umber of scenes per area 6 0 W4SRLW Wireless 4 small button scene wallstation WR5 Wireless ELD34UVL835CDSWPDU Encounter x with WaveLinx TMSWPD WaveLinx Tilemount occupancy / daylighting 3A Relay with 00V LD4/LD6 Portfolio Commercial Recessed LED Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) EATO WaveLinx design and application guide 37

TITLE 4 06: Open office example TITLE 4 06 ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor offices without windows ot required in spaces without windows that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler W4SLRLW WaveLinx WR5 WaveLinx 4 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming umber of interior walls walls 3 walls Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet WR5 Wireless umber of hops from Wireless Area ler 4 hops 5 hops umber of areas per Wireless Area ler 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) 38 EATO WaveLinx design and application guide

TITLE 4 06 TITLE 4 06: Restaurant example ly Switched O/ Lumen Maintenance O/ Auto 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces without windows ot required in spaces without windows that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler 5 W4SLRLW WaveLinx WR5 WaveLinx 4 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler W4SRLW Wireless 4 small button scene wallstation Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet WR5 Wireless umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) EATO WaveLinx design and application guide 39

TITLE 4 06 TITLE 4 06: Retail example ly Switched O/ Lumen Maintenance O/ Auto Linear Dimming Module WaveLinx Relay 00V 00V lighting loads Out of the box 75% high end trim on to 50% Optional vacancy mode Plug load turns on with occupancy Individual luminaire daylight dimming to approximately 500 lux not required for indoor spaces without windows ot required in spaces without windows that are less than 0W Wireless Area ler Qty Catalog # Description Wireless Area ler 6 W4SLRLW WaveLinx 4 WSPMV00 WaveLinx Relay Switchpack with 00V dimming WR5 WaveLinx 4 LDCMPL07700VGR Linear Dimming Modules 3 4ELD34UVL835CDSWPDU Encounter x4 with WaveLinx s Top or dominant button half lights (sets lights to 50% or less) Remaining buttons trigger scenes Raise Lower Power measurement reporting through mobile application demand response available from wireless area controller Scheduling of partial off light levels and times from wireless area controller UL94 emergency control capabilities available via luminaire battery backup PoE etwork Switch provided by others Wireless Area ler Design Consideration Best Practice Maximum Gateway/Wireless Area ler range 50 feet to 50 feet LOS 300 feet LOS umber of interior walls walls 3 walls W4SRLW Wireless 4 small button scene wallstation 4ELD34UVL835CDSWPDU Encounter x4 recessed light fixture with 00V dimming Distance from Wireless Area ler to st WaveLinx device 50 feet 00 feet Distance between WaveLinx devices 75 feet 50 feet umber of hops from Wireless Area ler umber of areas per Wireless Area ler 4 hops 5 hops 6 6 WR5 Wireless WSPMV00 0A Relay w/ 00V Dimming LDCMPL0 7700VGR Linear Dimming Module umber of zones per area 3 6 umber of scenes per area 6 0 Local O O Bilevel Side Top Parking Garage Enhanced Digital T4 06 (a) (a) (c).6 (c).5 (c) 30.5 30.5 30.4 (e) (e) 40 EATO WaveLinx design and application guide

Distributed LowVoltage Power System The lowvoltage system that s practically plug and play. o more struggling to find qualified electrical labor for your job site. o more waiting weeks for commissioning teams. o more compliance woes. Eliminate costly project delays with our groundbreaking Distributed LowVoltage Power System, and save up to 0% on the total installed cost of your LED lighting and controls system. Designed to meet the code requirements of your project The DLVP system was designed entirely with compliance in mind, to rid you of unnecessary project snarls. Combined with Eaton s highly efficient lowvoltage LED fixtures, integrated or external sensors drive energy efficiency throughout the building. Features like scene control, receptacle control, and automatic turnoff help you customize your system to meet your area s requirements, and can achieve energy savings of up to 65%. Code compliance, outofthebox Meets or exceeds the requirements of ASRAE/ASI/IES, IECC and Title 4 energy codes. Linevoltage in. Lowvoltage out. EATO Connected Codes 4