FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

Similar documents
FIRELOCK NXT AUTOMATIC VALVE SYSTEMS NOT JUST VALVES SIMPLICITY.

VicFlex TM Stainless Steel Sprinkler Fittings

Deluge & Preac tion Systems

FireLock NXT TM Automatic Valve Systems

Worldwide Contacts.

TotalPac X Firecycle III Preaction Double interlock system

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E)

TotalPac X Single interlock SUREFIRE system

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

TOTALPAC2 Integrated Fire Protection System

I-745. Series 745 FireLock Fire-Pac for FireLock NXT Valves WARNING INSTALLATION, MAINTENANCE, TESTING, AND WIRING MANUAL WARNING

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

Discontinued Product

Series 759 FireLock Alarm Check Valve

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TotalPac 3 Firecyle III Deluge Remote controlled system

Model DDX Deluge Valve

Instructions for Installation, Operation, Care and Maintenance

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

Electric Release Panel Wiring Tips

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

30.45 Electric Release PDRP-2001

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

TECHNICAL DATA OBSOLETE

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

Florida Building Code 2010

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

Copyright 2016 AIA MasterSpec Full Length 09/16 PRODUCT MASTERSPEC LICENSED BY AVITRU, LLC TO VICTAULIC COMPANY.

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

TECHNICAL DATA. 319a. January 27, 2012

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

40.65 V36, K8.0. Dry Type Standard Spray. Horizontal Sidewall. Recessed Horizontal Sidewall

Specification/ Data Sheet

All electrical systems and components require CSA approval stamped on the nameplate of the heater.

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

FLUSH HORIZONTAL SIDEWALL

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

TotalPac 3 Wet pipe system c/w retard chamber

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

Tyco Fire Valves Pure Performance

40.60 V36, K5.6. Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

40.61 V36, K8.0 SLEEVE AND SKIRT PLAIN BARREL

40.60 V36, K5.6 SLEEVE AND SKIRT PLAIN BARREL

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

Fire Sprinkler Monitoring Products. Solutions and Service for Sprinkler System Integrity

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

40.19 V34, K115 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS

BERMAD Fire Protection

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

TotalPac 3 Deluge, Electric release Self-contained system

Commercial and Light Industrial Fire Alarm Control Panel

FF 120T FF 220T EXTRON EXCLUSIVE PATENT PENDING FLAT FIELD SPEAKER WITH TRANSFORMER SPEAKERS. See How it Works WHITE PAPER

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

Sprinkler Solutions for Storage Applications

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

CONSTRUCTION REQUIREMENTS

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

AGF Manufacturing Inc.

A. This section includes design and performance information for fire protection and suppression systems.

Report of Inspection/Test

Fire protection for buildings

DISCONTINUED PRODUCT

Simple On The Outside...

SECTION DRY-PIPE SPRINKLER SYSTEMS

Functional Performance Test

False Sense of Security???

Transcription:

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS

DRY DELUGE PREACTION COMPACT, SIMPLIFIED SOLUTIONS PB-403 REV C

FireLock Series 745 Fire-Pac Systems 1½ 8" 40 200 mm Included in the FireLock Fire-Pac are a water supply shutoff valve, the sprinkler system fire protection valve, alarm line pressure switches, air supervisory pressure switches, and valve position supervisory switch, with pressure gauges and FACP that are easily viewed through a window in the cabinet door. Pre-assembled valve, trim and all components in secure enclosure. The Series 745 Fire-Pac is FM Approved and culus Listed. All electrical enclosures and connections are UL Listed, and all materials and wiring conform to NFPA requirements. Minimize installation footprint. Greater usable floor space eliminate mechanical closets. The Series 745 Fire-Pac is the ideal option for installation of Victaulic FireLock NXT dry, deluge or preaction systems especially when systems are: Located in high traffic areas Installed in series and share common supply and drain lines Designed in zoned control areas Common installation environments Airports Data centers High-security spaces Industrial or mining facilities Parking garages High rise buildings Stainless steel cabinet available for corrosive applications victaulicfire.com 1 PB-403 REV C

FireLock Series 745 Fire-Pac Systems 2 PB-403 REV C

FireLock Series 745 Fire-Pac Systems Easily accessible Side and rear panels can be removed for easy access to internal components for inspection and maintenance. Internal lighting for service convenience. and perfectly compact New maximum height of 6'5" 1.9 m allows for increased portability and maximized space, providing a clean aesthetic installation in tight spaces. Customized solutions With more options available than ever before each Fire-Pac System is completely unique. Weatherproofing to NEMA 4 standards Pipe feed and drain can be located on the left, right or bottom panels Insulation and heating components available down to a minimum ambient temperature of 20ºF -6ºC Compressor and nitrogen fill kit options Panel design options now including an addressable panel capable of networking with other intelligent devices Special cabinet color option Clear, straight-forward wiring panel Easy to access and connect electrical panel is selfcontained within the Fire-Pac enclosure, reducing cabinet height and maximizing ease of delivery and installation. Optional included FACP is the RP-2001, containing power supply, stand-by batteries, battery charger, as well as connections for detectors, waterflow and tamper switches and the solenoid valve. Fast piping connections Water supply and drain can be connected from either side or bottom panels. All pipe connections feature Victaulic grooved couplings and fitting. Manual pull station is accessible through a supervised door. victaulicfire.com 3 PB-403 REV C

FIRE-PAC SERIES 745 FIRELOCK SYSTEMS Continued Quality Smaller Design. THE SAN FRANCISCO INTERNATIONAL AIRPORT IN CALIFORNIA INCLUDES THE WORLD S FIRST FULLY ACCREDITED MUSEUM IN AN AIRPORT. IN 2004 THE FACILITY REQUIRED A TRUSTWORTHY SYSTEM TO PROTECT ITS IRREPLACEABLE ARTIFACTS. THE SERIES 745 FIRELOCK FIRE-PAC CABINET MODELS, EACH CONTAINING 4" 114.3 mm SERIES 758 PREACTION VALVES, WERE CHOSEN TO PROVIDE STATE OF THE ART RELIABILITY AND EASE OF MAINTENANCE. THE FIRELOCK SERIES 745 FIRE-PAC CONTINUES IT S LEGACY OF QUALITY NOW WITH INNOVATIVE NEW FEATURES. 4 PB-403 REV C

victaulicfire.com 5 PB-403 REV C

U.S./World Headquarters 4901 Kesslersville Road Easton, PA 18040 USA victauliclocations.com EMEAI Prijkelstraat 36 9810 Nazareth, Belgium Asia Pacific Unit 808, Building B Hongwell International Plaza No.1602 West Zhongshan Road Shanghai, China 200235 PB-403 6489 REV C 02/2018 Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. All other trademarks listed herein are the property of their respective holders, in the U.S. and/or other countries. The terms Patented or Patent Pending refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. 2018 VICTAULIC COMPANY. ALL RIGHTS RESERVED.