A programme to measure radon gas in English schools

Similar documents
The UK National Radon Action Plan From Directive to Publication

Radon Survey Final Report

Relevant Radon properties

Radon Survey Summary Report

Management Standard: Fire Safety

Foreword. Síle de Valera, TD, Minister for Arts, Heritage, Gaeltacht and the Islands

Fire Protection Systems For Railway Vehicles WE ARE ENSURING FIRE SAFETY

Electrical Safety Policy

Fire risk management plan. MH/05/Revised/06/17

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years.

NHS Tayside. Fire Safety Policy

Fire Safety Policy SH HS 06. Version: 4. Summary:

Fire Safety Policy. Contents. This policy was approved by the Trustees on 6 September 2018 and will be reviewed not later than every 5 years.

TRANSPORT & INFRASTRUCTURE

Appendix H. BGS BR211 Radon Report

St Edward s Oxford FIRE SAFETY POLICY

Environmental Impact Assessment

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

European Commission approach with regard to radon

Periodic Electrical Testing Policy

Interim Advice Note 76 / 06 ASSESSMENT PART 1 AIMS AND OBJECTIVES OF ENVIRONMENTAL ASSESSMENT. Contents

Fire Safety Strategy

Fire Safety and Arson Prevention

Fire Risk Management Policy. UK September 2017

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

Equipment Projector Screen Flipchart and Pens Cable Covers. Duration 1 hour

CORRECTIONS WITHIN DESIGN MANUAL FOR ROADS AND BRIDGES AUGUST 2009

Note: Please send the original Policy with both signatures on it to the Norfolk CPU for the audit trail.

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

To seek Cabinet approval of the Council s Fire Safety Policy. It is proposed that Cabinet approves the Fire Safety Policy.

Location: The Wildlife Trust for Bedfordshire, Cambridgeshire and Northamptonshire, Lings House, Billing Lings, Northampton NN3 8BE

Guide to Membership Assessments

FIRE SAFETY POLICY June 2014

SHORELINE, FLOOD AND COASTAL DEFENCE MANAGEMENT PLANS

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

CCTV Policy. Core values in daily life at St John Rigby College are expressed as:

It s Your Fire & Rescue Service... What we delivered for You in 2012/13

BEST VALUE PERFORMANCE INDICATORS CONSULTATION: INSURERS VIEWS ON ITS IMPLICATIONS A RESPONSE BY THE ASSOCIATION OF BRITISH INSURERS

LIFE SEC ADAPT PROJECT

Fire Risk Assessment

Kempston Community Fire Station Action Plan

CHC's One Big Housing Conference Health and Safety Update: Gas Safety

Published in March 2005 by the. Ministry for the Environment. PO Box , Wellington, New Zealand ISBN: X.

West Yorkshire Fire & Rescue Authority. Fire Protection Policy

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett

1. Good Practice Example: Quarter Regeneration Programme (Budapest, Hungary)

Fire Safety Protocol

International Requirements for the Control of Radon

Fire Safety Management

Support for staff involved in the use of steam cleaning machines. C21/HCQAI Criterion 2 Outcome 8 & 10

Study of the Economic Value of Northern

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

KVP Policy QA2.6 Quality Area 2 Issue date: July 2017

Guided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)

NOTTINGHAM CITY HOMES

Conventional Electric Space Heating Systems

PERIODIC ELECTRICAL TESTING POLICY

BRUNILDA DACI INSTITUTE OF APPLIED NUCLEAR PHYSICS TIRANA-ALBANIA. KOZETA BODE Responsible person for Radon Measurement in Albania

Fire Safety Policy 2018/19

DOMESTIC SMOKE. working for a cleaner, quieter, healthier world

FIRE SAFETY POLICY. Executive Management Team. Health, Safety and Fire Steering Group.

Ebbsfleet Development Corporation

Electrical Safety Policy and Management System

Ultimate Security Provider

Health & Safety Policy

7. DOES THE PLAN OR PROJECT NEED AN APPROPRIATE ASSESSMENT?

This document is a preview generated by EVS

Qualification Specification. Fire Marshall I N G A W A R D S I N T R A S A F E T Y S R D S A F E T Y T A W A. Version

FIRE SAFETY POLICY. This policy document replaces any previously published documents and comes into effect September 2018.

Green Infrastructure planning must be evidence led, thus the importance of this stage in collating your information and responses.

Totally Integrated Solution For Electrical Instrumentation, Mechanical and Trading

FIRE RISK ASSESSMENT COMPETENCY COUNCIL

Radon Testing and Reporting Plan. Tillamook School District #9 Tillamook, Oregon

GREENER GREENWAYS CASE STUDY A LARGE UK-WIDE INITIATIVE BY SUSTRANS, PROMOTING BIODIVERSITY

Strategic Environmental Assessment Screening Report. Dublin Port Masterplan Review 2017

Fire Safety Policy. Document Author: Director of Estates, Fleet & Facilities Management

AGT 1 Confined Space. Authorised Gas Tester 1. Scienco Limited. Authorised Gas Tester 1 1

National Radon Action Plan and Radon Database

ROCHFORD LOCAL DEVELOPMENT FRAMEWORK: Sustainability Appraisal/ Strategic Environmental Assessment. Rochford Core Strategy Preferred Options Document

Regulatory Reform (Fire Safety) Order A short guide to making your premises safe from fire

Lifting of evacuation orders and subsequent efforts in Japan

EC - RADON Latest strategies and draft regulations

Explanatory notes added for IEMA Quality mark submission.

INTERNATIONAL STANDARD

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

Evacuation Policy for People with Special Needs

The Royal Wolverhampton NHS Trust

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

Cotswolds AONB Landscape Strategy and Guidelines. June 2016

HHIC consumer guide to gas boiler servicing

INITIATIVES AND POLICY DIRECTIONS IN MAKING CITIES RESILIENT

Longmore House Salisbury Place Edinburgh EH9 1SH. 18 January 2008

Writtle University College Policy & Principles for Sustainable Development

Fire Policy. Fire Safety Order (2005) Dangerous Substances and Explosive Atmospheres Regulations (2002)

Local Authority Borough: Pembrokeshire Coast National Park

Custom & Self Build: Extending Housing Choice

IGEM/G/5 Edition 2 Communication 1762 Gas in multi-occupancy buildings

Welcome. /The Design Companion 4. /Planning London 7. /Getting Homes Built 8. /Transport & Streets 10. /Tech & The City 12

Transcription:

A programme to measure radon gas in English schools Progress review and lessons learnt Tracy Gooding 17 May 2012 Centre for Radiation, Chemical and Environmental Hazards

Why measure radon in schools? Largest source of radiation exposure to members of the public; focus on children Major revision of radon map - new dataset of Affected Areas HPA has considerable experience of monitoring schools in high radon areas and providing advice Radon mitigation techniques are well-established and durable Legislation requires employers to take action in radonprone areas Aim: To improve health protection by giving duty holders in schools the means to ensure that no individual is exposed to excessive levels of radon gas

Radon indicative map of England and Wales Radon Affected Areas show where at least 1% homes exceed 200 Bq m -3 Action Level Affected Areas are based on radon measurements in existing homes, combined with geological units

Radon in English schools programme (2008 - ) A multi-year, cross-government programme to: raise radon awareness in schools (age range 5-16) identify which schools are in radon Affected Areas target councils and school managers, and provide relevant radon information and advice encourage radon measurements help duty holders to understand the results and act upon them appropriately emphasise the need to protect children from excessive radon exposure

Regulations and recommendations The Management of Health and Safety at Work Regulations 1999 3 (1) Every employer shall make a suitable and sufficient assessment of - (a) the risks to the health and safety of his employees to which they are exposed whilst they are at work... The Ionising Radiations Regulations 1999 3 (1) these Regulations shall apply to - (b) any work carried out in an atmosphere containing radon 222 gas at a concentration in air, averaged over any 24 hour period, exceeding 400 Bq m -3 Limitation of Human Exposure to Radon RCE-15 2010 The HPA recommends that the domestic Action and Target Levels should be applied to all schools.

Radon testing in a school 20 m Calculate total area (35.4 x 16) - (2.3 x 17) = 527 20 x 25.7 = 514 5.7 x 5.7 = 33 16 x 21.8 = 349 11.4 x 7.4 = 84 Total area = 1507 m 2 Number of monitors = total area/100 15 or 16

Progress to date % > 400 Region Councils Schools Committed/ Not committed/ Monitored > 400 monitored no information Bq m -3 Bq m -3 North West 15 4 261 24 9.2 West 7 6 190 11 5.8 Midlands East 5 3 437 64 14.6 Midlands North East 3 5 111 10 9.0 Yorkshire & 6 6 63 16 27.1 Humberside Total 36 24 1061 125 11.8 Phase 1 - North West, West Midlands Phase 2 - East Midlands, North East, Yorkshire & Humberside

Events, complications and initiatives Changes within councils - new Directors and staff losses Change of government - pressure on finances Collaborative groups of councils within region - mutual support, but local precedents Councils undertaking measurement outside the Radon in Schools programme schedule - embellishments and editing Timescales extended from original three-year schedule Challenge of responding to local needs when high radon levels found - difficulties finding local mitigation services and remonitoring Coping with new advice on schools from HPA

Lessons learnt Use existing contacts and resources Know your audience - use existing terms and be aware of local issues Tailor the literature and other resources for the programme Explain clearly which schools have been chosen and why Ensure that responsibilities are allocated appropriately Establish clear communications with contacts of sufficient authority Promote consistency of approach across councils and regions Follow up and support, especially when high radon levels are found

The programme aim To improve health protection by giving duty holders in schools the means to ensure that no individual is exposed to excessive levels of radon gas www.ukradon.org