GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

Similar documents
GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

GL-CO-RFG Channel Gas Leak Alarm System

A series of technical features make this gas detector extremely versatile, reliable, accurate, and safe.

Electronic control unit for gas leak detection with 4 detection zones

TECHNICAL CATALOGUE GAS LEAK DETECTOR AND SOLENOID SAFETY VALVES

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

CHCO Double Gas Detector

Danfoss gas detection units

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Ammonia Leak Detector Manual

Warranty Registration

Gas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44

GAS MONITOR Model Model

KAE Gas Alarm Operation Manual

(CH 4 ) METHANE GAS DETECTOR AE09/GM, AE09/GM-12, AE09/GM-24

N L L1 C NC 230V MULTI-ZONE WIRELESS CLIMATE CONTROL SYSTEM CH175

Macurco HD-11 Hydrogen Gas Detector

GS100M Gas Detection Controller

GS100M Gas Detector. Technical Specification

169MHz Telecare Devices Gas & Carbon Monoxide Detector

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

Macurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference

The guarantee on this appliance is valid for 12 months from the first day of installation.

Instructions for Use and Warranty Details. RH17-900mm Island Canopy Rangehood

Safety Siren. Owner's Manual. Family Safety Products Inc. Carbon Monoxide, Propane & Methane. Model Number HS80004 HS80104 HS80204 HS80504 DETECTOR

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Installation & User Manual DURAUTO. Domestic Gas Detector

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

MO n : 12JMC rév A

Zareba Metro Gas Detector

Introduction Carbon monoxide (CO) is a colorless, odorless and tasteless gas which is toxic and can quickly become a mortal danger. Amongst others, ca

TEMON 4-C. Doc. N MO-0368-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 4-C OPERATION MANUAL. Microener- Copyright 2010 FW 2.1 Date Rev.

Danfoss gas detection units

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

QD6310. Fixed Gas Detector Operation Manual

NG-9B NATURAL GAS ALARM

KAB Gas Alarm Operation Manual

EXPLOSION-COUNTERACTING SYSTEM «UDAR-KB» Installation Guide

Cooking c o l l e c t i o n

LS1. Operator Manual. Kane International Ltd

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

BX444-M Gas Detector. Features. Application. Operation

WIRELESS GAS DETECTION & SHUT OFF SYSTEM INSTRUCTION MANUAL. Wireless Gas Detection & Shut Off System - User Manual & Instructions

Multi Channel Gas Detection System AGDS MC. The Home of Control & Automation in Ireland

BX444-Mc Gas Detector

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

Control Unit BX280 CONFORMITY EN EN EMC EN Isntallation and user Guide. Firmware Version 9.0

EUROFLAT SERIES TYPES C... S... M...

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

User Manual 120/240/300 Outdoor Motion Detector

Refrigerant Leak Detector Manual

Cooker Hood LA-72-CAN.

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

TECHNICAL AND OPERATION DOCUMENTATION

GAS-Mate. Combustible Gas Leak Detector

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

Remote alarm unit Art. Nr.:

Smoke Alarm User s Manual

CTT8 TEMPERATURE MONITOR DEVICE

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

Four Channel Gas Detection System AGDS 4. The Home of Control & Automation in Ireland

NGD8800 USER S MANUAL

169MHz Telecare Devices Carbon Monoxide Detector

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

CARBON MONOXIDE DETECTOR, i4h-co-m330

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

PR5. INSTRUCTION MANUAL IM846-U v0.4

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

INSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

COMBY 4000 & 9000 STEAM CLEANER OPERATOR MANUAL

Operating instructions

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Renew the air, prevent mold and save energy! ASPIRVELO AIR ECOCOMFORT

CH193 WiFi PROGRAMMABLE THERMOSTAT WHENEVER WHEREVER CONNECTED. Intelliclima+

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

USERS MANUAL FOR GAS BOILERS

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

TC100N. Fixed Gas Detector Operation Manual

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR (AMBIENT-TYPE) OWNER S MANUAL

USER MANUAL 03-0_MOD-KH1203US_H5_H5.indb _MOD-KH1203US_H5_H5.indb /11/08 21:28: /11/08 21:28:13

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Register your product and get support at. AC4076. User manual

Eclipse Self-Check UV Scanner

Operation and Maintenance Manual

testo 316-EX gas leak detector Instruction manual

Pioneer-R16 Gas Monitor Operator s Manual

Flame Safeguards LFE10. Building Technologies HVAC Products

EUROBOX SERIES TYPES CM... SM... MM...

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

The device is not suitable for continuous operation, but only for short-time operation (note lifetime of battery).

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

GS100M Gas Detector. Features. Application. Operation

Macurco CM-E1 Carbon Monoxide Detector

Transcription:

GAS LEAK DETECTORS FOR METHANE AND LPG P11 - P12 1

Sicurgas P11 and P12 it is a device, that through a sensitive sensor, detects methane gas concentration (P11) and LPG concentration (P12) in domestic environments. Sicurgas P11 and P12 are operating when the gas concentration in the air is much below of the lower explosion limit (L.E.L.). In case of alarm, interferes as well an acoustic and light alarm that is going to prevent the danger. Simultaneously Sicurgas is making the relay to interfere to control the gas interception valve. EXISTS THE POSIBILITY THAT YOU FEEL THE GAS SMEL BEFORE THE DEVICE GIVES AN ALARM SIGNAL. S i c u r g a s I N S T A L L A T I O N ATTENTION gas detector installation is not released from compliance with all rules regarding features, installation and use of the gas appliances, ventilation of the rooms and the discharge of the combustion products prescribed by the EN norms, implementation of the Art. 3 of the law 1083/71 and of the national legislation in force. Before installing the device, it is recommended to read carefully this instruction manual. GREEN LED power supplied device Gas detectors Sicurgas P11 and P12, when are connected to a normally closed (NC) valve with manual reset are giving positive safety. This means that the gas interception valve is closing to interrupt the inflow, as well in case of line voltage absence. For having the maximum security can be used more gas detectors Sicurgas, connected to the same gas interception valve. For e.g. can be mounted a P11 (P12) in the place where is installed the boiler and another one in the kitchen to control the stoves. 1 WALL MOUNTING Sicurgas is supplied with a base suitable for mounting in built-in boxes with 3 modules or in round boxes. Remove the base/cover retaining screw and ease off the cover. Fix the base on the wall (see paragraph 3) or in a built-in box using rear entry for the entries of the connection cables. ATTENTION! Do not open the device, because this may cause electrical shocks or malfunction. B 60 mm A 83,5 mm YELLOW LED defective detector RED LED ALARM - gas concentration is higher than the alarm threshold for built-in boxes 503 A with modules for round built-in B boxes pre-fractured area to increase the space required for wiring fixing srew base-cover After executing the mounting and the connections (see paragraph 4) replace the cover on the base ensuring the two cover pegs are correctly located on the two latching tabs. Screw again the fixing screw and apply in the corresponding place the provided adhesive label indicating the replacement date. 2 e n g l i s h

G A S L E A K D E T E C T O R S F O R M E T H A N E A N D L P G 2 SICURGAS PLACEMENT Sicurgas P11 must be fixed on the wall, about 30 cm from the ceiling and at a distance from gas user device, between a minimum of 1 meter and a maximum of 4 meters, in such position as to allow natural air circulation. max. 30 cm S i c u r g a s P11-P12 min. 1 mt max. 4 mt 3 4 Sicurgas P12 must be installed approximately 2 meters (minimum 1m maximum 4m) from the gas user device and about 30 cm from the floor. ELECTRICAL CONNECTIONS Sicurgas P11 is already equipped with two internal alarms: one visible and one acoustic. Just connect the line 230V c.a. 50Hz to the terminals 4 and 5 to ensure the gas presence signaling in the environment. It is recommended to use a valve with manual reset to stop the gas supply when there is an alarm situation. The internal relay can control all kind of power supplied valves with manual reset: normally closed (NC), always power supplied, which require a commutating stable relay; normally opened (NO), which require an impulse relay. Relay operating mode can be chose in the installation moment, by moving a switch (JP6) on the printed circuit, normally supplied for functioning with stable relay for NC valves (down switch). min. 1 mt max. 4 mt max. 30 cm ATTENTION! DO NOT place the device behind or under cabinets or shelves that are not allowing the natural air circulation in environment. DO NOT place it near aerators (minimum distance 2 meters). DO NOT place it on the vertical bakery surfaces, steam sources, in places where can be achieved by splashing water, near sinks, etc. Do not place where environmental conditions are different from the prescribed operation conditions. switch JP6 in down position (B) EXAMPLES OF CONNECTION predisposed in the factory stable relay for normally closed NC valves with EXAMPLE OF CONNECTION with stable relay, manual reset always power supplied, to control a normally closed valve with manual reset (down switch). GPL switch JP6 in up position (A) impulse relay for normally opened NO valves with manual reset The system guarantees maximum safety, the gas inflow will be stopped in case of: gas concentration threshold exceeding; power supply lack of the valve only or of the detector; connection breakdown between the detector and the valve. L N NC possible external alarm For device power supply, connect the terminals 4-5 to the circuit 230V-50Hz. e n g l i s h 3

S i c u r g a s O P E R A T I O N IMPULSE RELAY, with current activation, to control a normally opened valve with manual reset (switch in up position) The connection will ensure the interruption of the gas inflow in case of gas concentration threshold exceeding. L N NA USING MORE sicurgas UNITS TO CONTROL SEVERAL ROOMS WITH ONE GAS VALVE Example of connection for several Sicurgas detectors with stable relay that controls the same normally closed valve NC and an external alarm. The contacts must be connected in series. Example of connection for several Sicurgas detectors with impulse relay which controls the same normally opened valve NA. The contacts must be connected in parallel. L N L N NA OPERATION 5 6 PLUG IN THE POWER SUPPLY (230Vc.a. 50Hz). At the first detector switch-on and after any power supply failure, Sicurgas enters into pre-heating and a sensor stabilization phase that continues maximum 3 minutes. During this period will flash alternately the red and green led indicating that the device is not ready yet for gas detection. After this period just the green led will remain switched on. DEVICE CONTROL AND SILENCING alarm test/ silencing key (cord for P11) Sicurgas is provided with a TEST/SILENCING key, that allows to check the installation or to inhibit the alarm. This key is activated through a cord for P11 methane gas (installed about 30 cm from the ceiling) or through a button located on the body of P12 LPG (installed about 30cm from the floor). To test the installation press the TEST/SILENCING key for 10 sec. In this way will be activated a control procedure of about 30 sec., during which will be checked installation components. Alarm inhibition is used instead to avoid an involuntary intervention of the detector, in fact Sicurgas sensor, as all available on the market sensors, while being very selective can also participate for other substances, for example: alcohol vapors, wine etc. For example, during the use of wine while preparing food is possible, that the detector will enter in alarm situation. To avoid this inconvenience press the TEST/SILENCING key for approx. 3 sec. After having pressed the silencing key, for 10 minutes we will have a non-alarm situation: the buzzer does not emits acoustic signaling, the relay returns in non-alarm position and the red and green led, are flashing alternately to indicate the silence period; acting again on the switch during 10 minutes of the silence period, the detector will immediately resume the normal operation. 4 e n g l i s h

O P E R A T I O N H O U R S Intellitherm O P E R A T I O N After 10 minutes, the detector resumes automatically the normal operation. Here is possible, knowing that can be used substances which can cause a false alarm, to reduce in advance detector s sound to prevent the signalizations and gas shut off of the stoves (due to gas valve intervention). Some of the most common substances that can cause false alarm are the following: wine - liquors - alcohol - deodorants - stain-removers - varnish thinners - hair spray - excessive steam. Sicurgas also allows to set the type of the acoustic alarm, see picture on the side. intermittent SOUND switch JP3 in up position (A) continuous sound switch JP3 in down position (B) 7 maintenance AND CLEANING Pay attention to temperature values or to the extreme humidity. To give the maximum security the detector must be constantly powered. For routine maintenance and for the temporary closing-down of the device, it is recommended to contact an authorized technician. Regularly check the correct operation using the appropriate button or a gas test. Other test methods may damage the equipment. To clean the unit, use a soft cloth without using chemical cleaners or solvents. ATTENTION! in case of alarm: 1. turn off all opened flames in the room. 2. close the tap of the gas meter or of the L.P.G. gas cylinder. 3. do not switch on or off lights, do not operate electrical equipments or other electrically operated devices. 4. open the windows and the doors to raise the ventilation inside the room. 5. do not use telephones in the room where you suspect gas presence. If the alarm stops it is necessary to identify the matter that caused it and act accordingly. If the alarm continues and the gas leak cannot be identified or cannot be eliminated leave the room and from outside call the emergency services. T E C H N I C A L F E A T U R E S Device of A type. Shockproof insulating material casing. Protection degree: IP42. Operating ambient temperature / humidity: from 10 to 40 C, max. 90 UR%. Power supply: 230Vc.a. 50Hz. Consumption: 4 VA. Sealed relay to avoid sparks during switching. Maximum power of the controlled valve: 450VA at 230Vc.a. 50Hz. e n g l i s h Contacts rating: 6(2)A / 250Vc.a. Switch for choosing functioning relay mode, stable or impulse. Semiconductor sensor for gas detection. Internal visual and acoustic alarms. Intervention threshold volumetric value: (% L.I.E.) 9% for methane. (% L.I.E.) 10% for LPG. In compliance with the standard EN 50194. 5

S i c u r g a s n o t e S 6

S i c u r g a s P11-P12 7

5679455_GB TO BE COMPLETED BY THE INSTALLER Installation date Installation place Identification code/manufacturing date (the code is indicated inside the cover) Sensor replacement date (sensor replacement date is indicated on the front cover label) N.B. THE DETECTOR HAS TO BE REPLACED AFTER A PERIOD OF FIVE YEARS FROM THE INSTALLATION DATE STAMP AND SIGNATURE OF THE INSTALLER FANTINI COSMI S.p.A. Via dell Osio, 6 20090 Caleppio di Settala, Milano Tel. +39 02 956821 Fax +39 02 95307006 info@fantinicosmi.it supportotecnico@fantinicosmi.it w w w. f a n t i n i c o s m i. i t

Sicurgas P13 CO carbon monoxide detector with electrochemical cells for domestic use Sicurgas P13 should be ideally installed in bedrooms or in premises with more frequent occupancy. For a correct operation it must be installed close to the occupants breathing at a height ranging between 0,8 and 1,2 meters from the floor away from any object or walls limiting the air circulation. 138 30 Dimensions (mm) 86 Gas type Power supply Contacts rating Test button Operating temperature Protection degree P13 CO carbon monoxide 230Vca - 50Hz 6(2)A - 250Vca yes -10 40 C IP42 ELECTRICAL CHARACTERISTICS Power supply: 230Vca 50Hz. Consumption: 4 VA. Output through electromagnetic relay. Contacts rating: 6(2)A - 250Vca. STANDARDS AND APPROVALS In conformity with EN 50291. INSTALLATION Mounting in built-in 3-module boxes, on the wall or in round boxes. Mounting hole suitable for built-in 3-module boxes. 83,5 mm 60 mm 42

The detector should be fixed on the wall at a height of approximately 1,20 mt from the floor. For a correct functioning of Sicurgas P13, avoid installing the device: behind or under cabinets or shelves that can prevent the natural air circulation in the room; near air conditioning systems (minimum distance 2 meters); on the vertical line of cooking units or steam sources (bathtubs, etc.); in places, that could be reached by spraying water, near sinks, showers, etc. 0,8 1,2 mt OPERATION Sicurgas P13 detects CO carbon monoxide through its electrochemical cells probe in domestic environments. CO carbon monoxide is a dangerous gas due to the fact that it s inodorous and colourless. In case of very high concentration it could lead to death. Sicurgas P13 helps detecting CO leaks, however it cannot prevent chronic effects caused by prolonged exposition to CO. Sicurgas P13 operates depending on the CO concentration in the environment according to the norm EN 50291, as follows: 50 ppm: alarm ON with 60 to 90 minutes exposure 100 ppm: alarm ON with 10 to 40 minutes exposure 300 ppm: alarm ON with 3 minutes exposure In case of alarm an acoustic and luminous signal turns ON to warn about the danger. At the same time Sicurgas P13 activates a relay that operates a valve or a ventilation system. TEST BUTTON Sicurgas P13 is equipped with a TEST button to verify that the system operates properly. The test button can be enabled by pressing in the low part of the product as shown in the drawing. To run the TEST properly press the button until a buzzer is activated (yellow and red LED flash alternately, green LED is on). The device goes back to normal functioning after 30 seconds. P Some substances could create a blind alarm, such as alcohol, deodorants, stain removers, paint thinners, hair sprays, trichloroethylene. Sicurgas P13 is equipped with a luminous and an acoustic alarm. Electrical wiring as shown in the drawing to install properly the device and connect it to a NC valve or a ventilation system. TECHNICAL FEATURES Spare catalytic sensor to detect CO carbon monoxide. Shock proof body. Internal luminous and acoustic alarms. 3 warning LED: Green LED: the device works properly Yellow LED: malfunction Red LED: ALARM, CO carbon monoxide is being detected Sensor life: 5 years from the production date (see replacement date on the device). The relay of the device is a sealed type and filled with inert gas that guarantees the absence of sparks when commuting. ACCESSORIES S80 Acoustic and light signalling device. 43