ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

Similar documents
Cold chain monitoring technologies. Facility monitoring

Central Monitoring System with ECOLOG-NET LAN Dataloggers DataloggingCompany

ECOLOG Data logger series we prove it.

ECOLOG Data Sheets Status Octobre 2000

ECOLOG Data Sheets Status May 2015

ECOLOG Datalogger Series

Measuring Recording Online Monitoring Regulation Alarming

ECOLOG-NET LH2. Operation Manual. EL6008Ed ECOLOG-NET LH2

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

Call stations and extensions

Two-Channel Gas Controller

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring


OPUS20 LAN-Datalogger Future Inside

Flair 500 Series Annunciators

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Dew point set DS 400

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Smart Wireless Sensor

HRX3000. Technical Manual

portable gas analyser

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

Lift Station Level Controller

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

EasyLog Data Logger Series

AS950 REFRIGERATED SAMPLERS

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Complete packages with Software and Controller

Oxygen (O2) Single-Point Gas Detection System

Analog Room Pressure Monitor RPC Series

YOUR PARTNER IN FIRE & GAS DETECTION

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

AS950 PORTABLE SAMPLERS

SENSORS TRANSMITTERS. Process monitoring

EasyLog Data Logger Series

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

EL-OEM-3 OEM Packaged Voltage Data Logger

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Smart Wireless Sensor

Process & TeMPerATUre UniversAl input DigiTAl MeTers

HRX Technical Manual. Version 1.2

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Sensors Transmitters. Pressure / Temperature / Humidity / Air velocity / Airflow / Air quality / Solar / Light. European Manufacturer

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

GL100 series (vol 1, rev 1.0)

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Sintrol Snifter A2 EX. Manual. Version 1.2.3

Model KBF 240 Constant climate chambers with large temperature / humidity range

Specifications Minimum Typical Maximum Unit

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Fire control panels FC726 FC726-XA

FCCP 200: Fume-cupboard indicator and monitor

PR / MP I Laboratory / Medicine

Affordable wireless monitoring without compromise

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Medical Refrigerators

Chromatographic Air circulated Refrigerator, two-door TC 603

Fire control panels FC360

HAMSTER-A and HOTDOG

ICH110. Climate Chamber. Product specification

ICP450. Compressor-cooled incubator. Product specification

ICH260C. Climate Chamber. Product specification

FDA241, FDA221 Siemens ASD

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Constant climate chambers

ICH750L. Climate Chamber. Product specification

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Constant climate chambers

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

Ness acomms Install & User Manual

Mimic display driver, LED ribbon cable

Security Alarm Systems

portable gas analyser

FDA241, FDA221 Siemens ASD

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Affordable wireless monitoring without compromise

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

MLTXD16 Temperature Datalogger with Internal and External Sensor. Accuracy & Resolution ±0.3 C avg res. 0.5 C Storage Temperature -40/85 C

Constant climate chambers

TABLE OF CONTENTS. Page 2

DATA SHEET CS8100 CS8100_IT_EN_DS049REV02_IS

EL-OEM-3 OEM Packaged Voltage Data Logger

Monitoring system. testo 160 Monitoring system for the monitoring of temperature, humidity, light intensity, UV radiation and CO 2. concentration.

GPS or DCF 77. DTS Masterclock

Panel Mounted Fault Annunciator Series

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

IC60 Sintony 60 Intrusion Control Panel

Constant climate chambers

HOST SERVER CRITICAL INFRASTRUCTURE & ENVIRONMENTAL MONITORING SYSTEM DATA CENTER PLANT BASE STATION. Generator Fuel Level. Battery Monitoring

Transcription:

What is new? ELPRO has added an additional product to the successful ECOLOG-NET datalogger series to expand the possibilities of the central monitoring network based on LAN / WLAN. For the Central Monitoring System: ELOLOG-NET LA8 and WA8 (wireless) 8-Channel Datalogger for 4..20mA Signals LAN Part No. : 2720; WLAN Part No. : 2722 Capable of monitoring virtually any given sensor, as long as it has a 4-20 ma standard signal. Program the sensor to the user units and see data in the online monitor and in the evaluation Software Monitor any physical unit as - Humidity / temperature - Differential pressure - Pressure, atmospheric pressure - CO2, O2, other gases - Light - etc. Long cables to the sensors (up to some hundred meters) Power supply of all sensors through the datalogger NORDEALER S.A.S. Via Sassi, 14 27027 GROPELLO CAIROLI -PV- TEL. 0382814454 FAX. 0382826644 e-mail nord@nordelaer.com

Specifications: 64,000 data points, freely programmable Display of measured value, date, time, alarm, battery, status information Keypad for scroll of display and test functions 8 Channel input for 4-20mA; programmable axis to user units 2 digital input for external start, alarm delay, alarm reset, marking Multifunction alarm output: LAN, LCD, buzzer, local connection Operating temperature range -35 C to +55 C (datalogger only) Dimensions (L x H x D, without external sensors) 160x110x50 mm Weight (dependent on type and sensors) approx. 0.6 kg Voltage supply: 1 lithium battery 3.6 VDC for autonomous datalogging External power supply 10VDC to 30V DC (e.g. 24V sensor supply) Power supply to sensors, 2-wire or 3-wire system Long sensor cables, up to some 100 meters (depending to sensor used) LAN / W-LAN Network port Ethernet TCP/IP or USB Software and network compatibility: Fully integrated in the elprolog network software package: - Digiconnect to program IP address to device and search - elprolog Config to set up a network system - elprolog Monitor to show online data and trigger Alarm - elprolog Evaluation for detailed data evaluation, available for GLP / GMP LAN and WLAN (wireless) Ethernet compatibility Fits into the central monitoring system

Monitoring over the LAN / WLAN Network WLAN datalogger ECOLOG-NET WP4 4xPT100 for temperature measurement Alarmconfiguration Alarm Interface Dialing unit central alarm unit email, SMS sonic Printer cable length up to 100 m/sensor WLAN Access Point Fax, Voice Monitoring Station with elprolog MONITOR LAN Internet Local alarm cable length up to 100m/sensor Data and alarm analysis LAN datalogger ECOLOG-NET LP4 4xPT100 for temperature measurement LAN datalogger ECOLOG-NET LH2 1 or 2x combined temperature - and humidity measurement. LAN datalogger ECOLOG-NET LA8 (8x4..20mA) for acquisition of standard transducer signals (e.g. differential pressure) 3

Accessories for the Ecolog-Net LA8 rh/t Sensors for warehouse and incubator monitoring Humidity and temperature -40..+60 and 0%..100%rH M12 socket / connector 4 pins For warehouse and room monitoring Part No: 3310-T02 Humidity and temperature -40..+60 and 0%..100%rH M12 socket / connector 4 pins For chamber and Incubator monitoring Part No: 3315-T02 Optional shield for outside monitoring of temperature and humidity

Converters for Temperature and Pressure Sensors: Differential pressure sensor Precision: +/- 2.5% FS 4-20mA; -50 +50Pa Part No: 3260-L Converter for all ML PT100 sensors; PT100 to 4-20mA using the M12 / 4-pin connector, programmable range Part No: 3350-A Differential pressure sensor Precision: +/- 1.5 Pa Various types available Part No: 3260-T Precision differential pressure sensor +/- 20Pa or +/- 100Pa Example: Part No: 3259-B (+/- 20Pa) Precision: <4 Pa: 0.05 Pa >4 Pa: 1.5%

Converters for CO2 Gas, Flow, Pressure, Water level: Monitoring in incubators: 0%..20% CO 2 Air or water flow monitoring Speed 0.3..20m/s. (4-20 ma); Part No: 3264-B Air quality CO 2 transmitter 0..2000ppm, 0..10V / 4..20mA Part No: 3271-F Light measuring Lux meter external use 0..100 klux, Part No: 3296-B Pressure, any range and size -1..9 bar Size G 1/4, 4..20mA; Part No: 3280-A Water level monitoring Level sensor D= 0..10 meters, 4..20mA; Part No: 3263-C

Applications for the LA8 Datalogger CLEAN ROOMS Grey Rooms Technical Area Monitoring of: Temperature; Humidity Differential Pressure Particles Gases Laminar Flow Cabinets

Applications for the LA8 Datalogger Shopping Malls Warehouses Storage Rooms Production Rooms Monitoring of: Temperature; Humidity Differential Pressure Light Gases