HYDROCIAT LW R407C. Water cooled chillers USE RANGE

Similar documents
CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Compact and silent Scroll compressors All-season operation

DYNACIAT POWER. High energy efficiency Compact and quiet

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Water chillers water/water type SIGMA Technical information manual

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

Aquaciat Free cooling

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

AQUACIAT. Inverter Heat pump USE RANGE GRAND INVERTER

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

High temperature air-to-water heat pumps

HT V2 HT Split

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Roof top SPACE RPC 450Z R407C M011

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

kw COOLING kw HEATING

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Roof top SPACE RPC 315Z R407C MA00

TCHVZ TCEVZ

WZH Ground source heat pumps

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Conditioning your ambient, maximising your comfort.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

LZA High efficiency air to water heat pumps with HP compressor

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Precision air handling cabinets Ciatronic MICRO/EXPAIR

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Blue Box Epsilon Echos +

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Aquaflair TRAC-TRAF-TRAH

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Advance Split

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

Precision air-handling cabinets. CIATRONIC System Ultimate precision air-conditioning NA C

ARV.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

V3000 KNX. KNX PID control system on water GENERAL DESCRIPTION

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

30HXC Nominal cooling capacity kw

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Air-to-water scroll chillers

CLIMACIAT AIR COMPACT

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning

Transcription:

Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity : 270 to 1140 kw Heating capacity : 350 to 1420 kw USE HYDROCIAT LW The HYDROCIAT LW screw compressor water cooled chillers are designed for indoor installation and offer an optimal solution for any refrigeration application in the air conditioning or industrial process. Units conform to regulations EN 60.204 EN 378-2 and to directives : - Machine (98 / 37 CEE) modified - CEM (89 / 336 CEE) modified 92/31 CEE - 93/68 CEE - Low voltage (73/23 CEE) modified 92/31 CEE - 93/68 CEE - DESP 97 / 23 CEE LW - LWP group 3 sizes 1200BZ (HPS) to 2800BZ (HPS) group 4 sizes 3200BZ HPS to 4200BZ HPS LWN outside PED (split unit) RANGE HYDROCIAT LW-LWP 2 compressors - 2 refrigerant circuits 12 models : LW - LWP 1200BZ - 1200BZ HPS - 1500BZ - 1500BZ HPS -1800BZ - 1800BZ HPS - 2150BZ - 2150BZ HPS - 2500BZ - 2500BZ HPS - 2800BZ - 2800BZ HPS. 3 compressors - 3 refrigerant circuits 4 models : LW - LWP 3200BZ HPS - 3400BZ HPS - 3750BZ HPS - 4200BZ HPS. HYDROCIAT LWN The HYDROCIAT LWN chilled water production units without condenser are designed to be connected to air or water cooled condensers. They can be connected to several models of our range of air cooled condensers EUROPA 2C. 12 models : LWN 1200BZ - 1200BZ HPS - 1500BZ - 1500BZ HPS -1800BZ - 1800BZ HPS - 2150BZ - 2150BZ HPS - 2500BZ - 2500BZ HPS - 2800BZ - 2800BZ HPS. HYDROCIAT LWP The design of the HYDROCIAT LWP water/water heat pump range is identical to HYDROCIAT LW. These machines provide solutions for a wide range of heating problems. They can also be used in cooling operation by reversing the cycle on the hydraulic circuits. 1

DESCRIPTION HYDROCIAT LW - LWP Water cooled chillers Compressors Accessible hermetic twin screw type Optimized profile of rotors ensuring high efficiency Electrical motor incorporated with part winding start Integral electronic protection fo motor Control of the phases balance and rotation direction Integrated overpressure valve Discharge temperature control Lubrication under controlled pressure 3-stage integrated oil separator Crankcase heater Thin filter at intake Discharge valve Slide for modulating continued output capacity control Assembly on antivibration mounts Integrated oil separator Installed at the compressor discharge The large amount of oil injected during the compression cycle necessitates the use of an oil separator. Oil, after separation from the refrigerant, is filtered before being injected into the compressor. Note : The refrigerant oil has several important roles to ensure the smooth running of the compressor. It : Lubricates bearings and moving parts and eradicates any direct contact between parts. Ensures a secure tightness between the different mechanical parts, thereby guaranteeing good volumetric output. Cools the compressor by direct oil injection into the gas volume being compressed. If required, the cooling of oil allows gas discharge temperature to be limited. Evaporator High performance copper tubes bundle Steel tubular plates Steel shell Corrosion-resistant baffles Thermal insulation with polyurethane foam Water cooled condenser High performance copper tubes bundle Carbon steel shell Carbon steel tubular plates Removable cast iron headers Safety valves on the refrigerant circuits HPS (High Power System) on LW/LWP/LWN...HPS models The HPS system allows a significant increase in the cooling capacity, improving the performance coefficients (EER) of your installation, particulary in part load, and therefore ensuring an optimal operation of the unit all year round. Refrigerant accessories Filter dryers with rechargeable cartridges Liquid sight glasses Solenoid valves on liquid refrigerant lines Thermostatic expansion valves Discharge check valves (LWN) Electrical panel IP 21 Electrical supply 400 V - 3 ph. - 50 Hz + earth (-5% / +4%) Main fused isolator with outside handle Transformer for control circuit Compressor motors contactors Compressor motors protection by fused isolators. General earth connection Phase controller (reversal, loss, over and under voltage) Electronic module with XTRA CONNECT microprocessor with the following main functions : - 2 remote switchable set points - chilled water temperature control - Possibility of water temperature variation according to the outside temperature (water law) - Low temperature ice storage control - Compressors discharge temperature control - Compressors anti-short cycle control - Control and optimisation of operating parameters - Counting and balancing of compressors operating time - Automaticity control LCD display panel, 2 lines of 20 characters allowing : - parametering of the unit - direct reading of all information: settings, water inlet/outlet temperatures, outside temperature, HP/LP pressures, unit operating status... - Faults control with memorization of the last 9 faults and operating reading of when those faults occured - Weekly management of the unit - Unit general fault display on terminals - Automaticity control on terminals - RS 485 output for bus connection with centralized Building Management System 2

Safety and regulation controls HP/LP pressure sensors Low and high pressure safety valves Chilled water control sensor (inlet or outlet) External temperature sensor Evaporator antifreeze sensor Compressors discharge sensor Evaporator water flow switch Capacity control Modulating capacity control : - fom 25 to 100 % (Sizes 1200BZ (HPS) to 2800BZ (HPS)). - from 17 to 100 % (Sizes 3200BZ HPS to 4200BZ HPS). HYDROCIAT LWN The HYDROCIAT LWN range of water chillers without condenser is derived from the HYDROCIAT LW. These units can be connected either to water or air cooled condensers.they can be combined with several models of our EUROPA 2C air cooled condensers range (see technical brochure). HYDROCIAT LWN are supplied with a nitrogen safety refrigerant charge. Accessories Identical to those of the HYDROCIAT LW HYDROCIAT LWP The HYDROCIAT LWP water-water heat pump range has the same design as the HYDROCIAT LW. The calories are taken from the natural water network (ground water,...) or from a water loop and are sent to the heating network through the thermodynamic circuit, instead of being discharged by a cooling tower as is the case with the water chiller. These water-water heat pumps can be used for cooling by reversing the cycle on the water circuits (modification of the hydraulic circuits to be made on site). Accessories Identical to those of the HYDROCIAT LW OPTIONS HYDROCIAT LW - LWP - LWN LOW NOISE version : acoustically lined housing compressors Antivibration equipment : - antivibration mounts - evaporator flexible sleeves - condenser flexible sleeves (LW - LWP) - refrigerant flexible sleeves (LWN) Compressor isolating suction valves Condenser water headers Heating recovery with brazed plates desuperheaters (1 for each refrigerant circuit - LW - LWP only) Low temperature glycol water Electronic expansion valve Progressive soft start Reduced height version Remote control unit Voltage-free contact relay board Management of several units - MULTICONNECT (LW - LWP only) LonWorks gateway Shackles Discharge pressure control valves (LWN split - system unit): necessary if the unit has to run for external air temperature below 12 C or if the unit has to start for water temperature below 20 C on condenser side (one valve on each refrigerant circuit). These valves are fitted on the unit for sizes 1200BZ (HPS) to 1800BZ (HPS) and delivered separately (to be fitted on site by customer) for sizes 2150BZ (HPS) to 2800BZ (HPS). 3

TECHNICAL CHARACTERISTICS HYDROCIAT LW - LWN - LWP 1200BZ 1200BZ 1500BZ 1800BZ 2150BZ 1500BZ 1800BZ 2150BZ HPS HPS HPS HPS Cooling capacity (1) kw 266 285 346 368 428 460 521 555 LW - LWP version Absorbed power (3) kw 79 82 98 101 119 123 137 142 EER/ESEER 3.36/4.28 3.48/4.34 3.53/4.54 3.65/4.64 3.57/4.5 3.72/4.66 3.78/4.44 3.91/4.56 LWN version Cooling capacity (2) kw 270 291 348 374 432 466 512 551 Absorbed power (3) kw 80 82 101 104 122 126 145 150 Type Hermetic twin screw Number 2 Rotation speed rpm 2900 circ.1 20 23 34 34 34 40 61 61 R407C refrigerant charge (4) kg Compressor circ.2 20 23 26 28 35 40 42 42 Capacity control Modulating from 25 to 100% (50 to 100% on each compressor) Type of oil for R407C BITZER BSE 170 Oil charge for compressor liters 2 x 9 15 + 9 2 x 15 22 + 15 Type Shell and tubes with dry expansion Number 1 Evaporator Water capacity liters 68 85 140 Hydraulic connections VICTAULIC type Maximum pressure on water side bar 10 Mini / maxi water flow m 3 /h 30 / 100 40 / 110 Type Shell and tubes Number 2 Water cooled Water capacity liters 2 x 25 2 x 36 49 + 36 condenser Hydraulic connections VICTAULIC type Maximum pressure on water side bar 10 Maximum water flow m 3 /h 192 200 LWN liquid receiver Capacity liters 2 x 90 130 + 90 2 x 130 170 + 130 Standard version Lw / Lp (5) db(a) 96 / 64 98 / 66 100 / 68 Low Noise version Lw / Lp (5) db(a) 88 / 56 90 / 58 91 / 59 HYDROCIAT LW - LWN - LWP 2500BZ 2500BZ 2800BZ 3200BZ 3400BZ 3750BZ 4200BZ 2800BZ HPS HPS HPS HPS HPS HPS Cooling capacity (1) kw 624 670 705 755 834 887 983 1113 LW - LWP version Absorbed power (3) kw 162 168 179 186 212 226 250 283 EER/ESEER 3.89/4.42 3.99/4.61 3.92/4.62 4.04/4.8 3.93/4.78 3.91/4.61 3.92/4.65 3.93/4.92 LWN version Cooling capacity (2) kw 619 664 690 744 - - - - Absorbed power (3) kw 169 175 190 198 - - - - Type Hermetic twin screw Number 2 3 Rotation speed rpm 2900 circ.1 56 63 55 62 42 70 66 66 Compressor R407C refrigerant charge (4) kg circ.2 56 64 55 63 60 50 66 66 circ.3 - - - - 46 70 66 73 Capacity control Modulating from 25 to 100% Modulating from 17 to 100% (50 to 100% on each compressor) (50 to 100% on each compressor) Type of oil for R407C BITZER BSE 170 Oil charge for compressor liters 2 x 22 22 + 2 x 15 2 x 22 + 15 3 x 22 Type Shell and tubes Number 1 Evaporator Water capacity liters 188 267 353 Hydraulic connections VICTAULIC type Maximum pressure on water side bar 10 Mini / maxi water flow m 3 /h 50 / 150 60 / 180 70 / 211 Type Shell and tubes with dry expansion Number 2 3 Water cooled Water capacity liters 2 x 49 2 x 56 56 + 2 x 36 2 x 49 + 36 3 x 49 3 x 56 condenser Hydraulic connections VICTAULIC type Maximum pressure on water side bar 10 Maximum water flow m 3 /h 240 300 316 310 333 420 LWN liquid receiver Capacity liters 2 x 170 - - - - Standard version Lw / Lp (5) db(a) 102 / 70 105 / 73 102 / 70 103 / 71 105 / 73 Low Noise version Lw / Lp (5) db(a) 93 / 61 96 / 64 94 / 62 96 / 64 98 / 66 (1) Cooling capacity for 12 / 7 C evaporator chilled water and 30 / 35 C condenser hot water (2) Cooling capacity for 12 / 7 C evaporator chilled water and 45 C condensing temperature (3) Compressors absorbed power (4) LWN units without condensor are delivered with safety charge of nitrogen (5) Lw : Global sound power level - Lp : Global sound pressure level at 10 meters, in free field, following ISO 3744 regulation 5

ELECTRICAL CHARACTERISTICS HYDROCIAT LW - LWN - LWP 1200BZ 1200BZ HPS 1500BZ 1500BZ HPS 1800BZ 1800BZ HPS 2150BZ 2150BZ HPS COMPRESSORS (1) Maximum nominal current A 216 270 324 378 (2 x 108) (162 + 108) (2 x 162) (216 + 162) Part winding starting current (3) A 377 531 585 774 Starting current with Soft start option(3) A 283 337 437 560 REMOTE-CONTROLLED AUXILIARY CIRCUIT (2) Maximum nominal current A 4 Transformer power VA 630 1000 HYDROCIAT LW - LWN - LWP 2500BZ 2500BZ HPS 2800BZ 2800BZ HPS 3200BZ HPS 3400BZ HPS 3750BZ HPS 4200BZ HPS COMPRESSORS (1) Maximum nominal current A 432 492 570 594 648 738 (2 x 216) (2 x 246) (246 + 2 x 162) (2 x 216 + 162) (3 x 216) (3 x 246) Part winding starting current (3) A 828 911 989 990 1044 1157 Starting current with Soft start option(3) A 614 647 776 830 924 REMOTE-CONTROLLED AUXILIARY CIRCUIT (2) Maximum nominal current A 4 Transformer power VA 1000 (1) Current for 400V / 3Ph / 50Hz voltage (2) Current for 230V / 1Ph / 50Hz voltage (3) Starting current of the biggest compressor + maximum current of others compressors in full load Nominal current for cables selection = add the maximum nominal currents indicated in the above tables Electrical panel for LW 1200BZ (HPS) to 2800BZ (HPS) 6

DIMENSIONS Water cooled chillers HYDROCIAT LW - LWP 2 compressors, 2 refrigerant circuits with option without option DN 200 DN 16 (1) P P without option with option a : cooling water inlet b : cooling water outlet c : chilled water inlet d : chilled water outlet Option 1 : compressor suction valve Option 2 : acoustically lined housing Option 3 : condensers headers (flexible hydraulic sleeves and flange/ adapter included) Option 4 : hydraulic flexible connections (flange/ adapter included) Option 5 : 8 antivibration mounts 300 x 50 x 25 NOTE : the electrical wiring is on the right of the panel through the bottom Dimensions in mm (1) 1850 (models 1200BZ and 1500 BZ), 1860 (model 1800BZ) for reduced height version. Compressor suction valve mounted as standard and acoustically lined housing not available for this version. LW - LWP A - B c - d D E F G H J K M N P R S Weight in kg empty in operation 1200BZ (HPS) PN 16 DN 150 PN 16 DN 125 135 3285 3260 2130 578 2200 2945 850 1950 400 170 670 1510 1620 1500BZ (HPS) PN 16 DN 150 PN 16 DN 125 135 4285 3595 2730 783 3200 3945 1050 1950 400 170 670 2120 2270 1800BZ (HPS) PN 16 DN 150 PN 16 DN 125 70 4285 3730 2720 783 3200 3945 815 2402 632 180 660 2880 3120 24

DIMENSIONS HYDROCIAT LW - LWP 2 compressors, 2 refrigerant circuits 4345 with option without option (1) 3200 without option 4005 with option a : cooling water inlet b : cooling water outlet c : chilled water inlet d : chilled water outlet Option 1 : compressor suction valve Option 2 : acoustically lined housing Option 3 : condensers headers (flexible hydraulic sleeves and flange/ adapter included) Option 4 : hydraulic flexible connections (flange/ adapter included) Option 5 : 8 antivibration mounts 400 x 70 x 25 NOTE : the electrical wiring is on the right of the panel through the bottom Dimensions in mm (1) 1970 for reduced height version. Compressor suction valve mounted as standard and acoustically lined housing not available for this version. LW - LWP A B c - d E F empty Weight in kg 2150BZ (HPS) PN 16 DN 150 PN 16 DN 125 2720 200 3420 3660 2500BZ (HPS) PN 16 DN 150 PN 16 DN 150 2680 179 3850 4140 2800BZ (HPS) PN 16 DN 150 PN 16 DN 150 2680 179 3920 4220 in operation 25

DIMENSIONS Water cooled chillers HYDROCIAT LW - LWP 3 compressors, 3 refrigerant circuits 4508 (1) 3200 4065 a : cooling water inlet b : cooling water outlet c : chilled water inlet d : chilled water outlet Option 1 : compressor suction valve Option 2 : acoustically lined housing Option 3 : condensers headers (flexible hydraulic sleeves and flange/ adapter included) Option 4 : hydraulic flexible connections (flange/ adapter included) Option 5 : 8 antivibration mounts 400 x 70 x 25 NOTE : the electrical wiring is on the right of the panel through the bottom Dimensions in mm (1) 2050 for reduced height version. Compressor isolating suction valve mounted as standard and acoustically lined housing no available for this version. LW - LWP A - B - C c - d Weight in kg D empty in operation 3200BZ HPS PN 16 DN 150 PN 16 DN 200 160 5320 5740 3400BZ HPS PN 16 DN 150 PN 16 DN 200 160 5670 6130 3750BZ HPS PN 16 DN 150 PN 16 DN 200 160 6020 6480 4200BZ HPS PN 16 DN 150 PN 16 DN 200 127 6280 6750 26

DIMENSIONS HYDROCIAT LWN 2 compressors, 2 refrigerant circuits (1) A Dimensions in mm (1) 1850 (models 1200BZ and 1500 BZ), 1860 (model 1800BZ) for reduced height version. Compressor suction valve mounted as standard and acoustically lined housing not available for this version. LWN a b c d e - f C D G H J K L M N P R Weight in kg empty in operation 1200BZ (HPS) 1 5/8 1 5/8 1 5/8 1 5/8 PN 16 DN 125 2130 135 450 450 450 751 3160 1954 400 455 560 1910 2020 1500BZ (HPS) 1 5/8 2 1/8 1 5/8 1 5/8 PN 16 DN 125 2730 135 410 350 500 1058 3730 2162 400 510 600 2530 2680 1800BZ (HPS) 2 1/8 2 1/8 2 1/8 2 1/8 PN 16 DN 125 2720 70 410 350 500 728 3730 2402 632 600 600 2820 3060 27

DIMENSIONS Water cooled chillers HYDROCIAT LWN 2 compressors, 2 refrigerant circuits (1) Dimensions in mm (1) 1970 for reduced height version. Compressor suction valve mounted as standard and acoustically lined housing not available for this version. LWN a b c d e - f B C D G H Weight in kg empty in operation 2150BZ (HPS) 2 1/8 2 5/8 2 1/8 2 5/8 PN 16 DN 125 600 2720 200 2720 460 3330 3550 2500BZ (HPS) 2 5/8 2 5/8 2 5/8 2 5/8 PN 16 DN 150 510 2680 179 2680 380 3860 4150 2800BZ (HPS) 2 5/8 2 5/8 2 5/8 2 5/8 PN 16 DN 150 510 2680 179 2680 380 3880 4180 28

RECOMMENDATIONS FOR ASSEMBLY HYDROCIAT LW - LWP Installation HYDROCIAT LW - LWP are designed for indoor installation and must be protected from adverse weather and frost. A free space of 1 meter must be left all around the unit for access to the electrical panel and other components. A free space on one side is also necessary (equal to the length of the unit) in case one of heat exchangers needs to be removed. Sound level problems should be studied in detail. Before installing the unit, study and if necessary treat (with the assistance of a sound technicien) the various possible noise transmissions in relation to the premises and its structure. If necessary the machine should be equipped with anti-vibration mounts and flexible connections (recommended and proposed as an option). Electrical connections All the indications necessary for the electrical connections are mentioned on the electrical diagram enclosed with the unit (to be respected). These connections must be made in accordance with accepted engineering practice and conform to the regulations in force. Leave the control circuit switched on to allow operation of the crankcase heater. The electrical mains supply must be fitted with a fuse or circuit breaker protection (to be supplied by the fitter). Hydraulic connections Water connections must be made in accordance with good engineering practice. Provide the accessories necessary for hydraulic circuits : - Expansion vessel, - Drain cocks at low points, - Isolating valves, - Air vents at high points, etc..., - Check that the water content in the installation is sufficient, - Provide, if required, a buffer tank. Commissioning In accordance with our installation and maintenance brochure. Maintenance See our operating and maintenance guide. Subscribe a maintenance contract. HYDROCIAT LWN Installation HYDROCIAT LWN re designed for indoor installation and must be protected from adverse weather and frost. A free space of 1 meter must be left all around the unit for access to the electrical panel and other components.. A free space on one side is also necessary (equal to the length of the unit) in case one of heat exchangers needs to be removed. Sound level problems should be studied in detail. Before installing the unit, study and if necessary treat (with the assistance of a sound technicien) the various possible noise transmissions in relation to the premises and its structure. If necessary the machine should be equipped with anti-vibration mounts and flexible connections (recommended and proposed as an option). Electrical connections All the indications necessary for the electrical connections are mentioned on the electrical diagram enclosed with the unit (to be respected). These connections must be made in accordance with accepted engineering practice and conform to the regulations in force. Leave the control circuit under voltage to allow operation of the crankcase heater. The electrical mains supply must be fitted with fuse or circuit breaker protection (to be supplied by the fitter). Hydraulic connections Water connections must be made in accordance with good engineering practice. Provide the accessories necessary for hydraulic circuits : - Expansion vessel, - Drain cocks at low points, - Isolating valves, - Air vents at high points, etc..., - Check that the water content in the installation is sufficient, - Provide, if required, a buffer tank. Refrigerant connections Work is to be carried out respecting the strictest accepted engineering practice and generally include : Installation of refrigerant piping between the internal part and the condenser - discharge and liquid pipes. Study with care the design (slope, diameter and trap to facilitate the return of oil to the compressor, particularly in part load). Fit refrigerant flexibles sleeves if the unit is mounted on antivibration mounts The length of connections between the 2 units will always be as short as possible (max. developped length : 15m, 6m of change in level; if indoubt, consult our technical departments). Vacuum cleaning of the circuit, refrigerant charge, commissioning. Maintenance Refer to the maintenance brochure delivered with each unit. Subscribe a maintenance contract 29

XTRACONNECT CONTROL ERGONOMIC INTERFACE PANEL - LDC multilingual screen (2 lines of 20 characters) - Pressures and temperatures reading - Pump control - Communication Available free contacts inputs / outputs Inputs : - External ON/OFF contact - Chilled water pump external ON/OFF contact - Setpoint 1/2 selection - General fault - Emergency stop - Compressors load shedding - 0-20 ma remote control Output :- General fault of the unit - General fault per dircuit - Pump control RS 485 OUTPUT IN STANDARD MODBUS-JBUS open Protocol (standard) LONWORKS Protocol (option) FREE CONTACTS RELAY CARD (OPTION) Available outputs : - Water flow fault - Antifreeze fault - Pump fault - Fans fault - Emergency stop fault - Low and high pressure fault - Compressors safety fault - Compressors superheating fault - Compressors lubrication fault - Discharge temperature fault - Compressors running REMOTE CONTROL BOX (OPTION) Operation and design same as display console MULTICONNECT MULTI-UNIT MANAGEMENT (OPTION) Main functions available: - Management of up to 8 units on a single water loop - Management in cooling mode (water chiller) or heating mode (heat pump) - Management of chilled-water or hot-water pumps - Centralised management of a backup unit - Unit load shedding - System time programming - Energy storage mode management - Fault management on each unit - Unit running time balancing - Integrated Modbus BMS link for obtaining information on unit operation and faults Non contractual document. With the thought of material improvement always in mind, CIAT reserves the right,without notice, to proceed with any technical modification. Head office & Factories Avenue Jean Falconnier - B.P. 14 01350 - Culoz - France Tel.: +33 (0)4 79 42 42 42 - Fax: +33 (0)4 79 42 42 10 e-mail: info@ciat.fr - www.ciat.com CIAT Service Tel.: +33 (0)4 79 42 42 90 - Fax: +33 (0)4 79 42 42 13 Compagnie Industrielle d Applications Thermiques - S.A. with a registered capital of 26 000 000 - R.C.S. Belley B 545 620 114 30