Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

Similar documents
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

ProAir CR43 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

M52 3-Phase INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

ProAir CR29 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

ProAir CR23 INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-Series Air Conditioner T15 Model

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

INSTRUCTION MANUAL. T-SERIES Air Conditioner. T29 Model Pentair Equipment Protection P/N McLean Parts 5736 N. Michigan Rd.

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

T-Series Air Conditioner T20 Model

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

T-Series Air Conditioner T53 Model

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL. Rev. D 2015 Pentair Equipment Protection P/N

GENESIS Air Conditioner. M52 3-Phase Model INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Equipment Protection P/N

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL. Rev. F 2015 Pentair Equipment Protection P/N

T-SERIES Air Conditioner. T62 Model INSTRUCTION MANUAL nvent Rev. F P/N

GENESIS AIR CONDITIONERS

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL. Rev. B 2016 Pentair Equipment Protection P/N

PROAIR Air Conditioner

T-Series Air Conditioner

T-SERIES Air Conditioner. T53 Model INSTRUCTION MANUAL nvent Rev. G P/N

T-Series Air Conditioner

PROAIR Air Conditioner

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

SPECTRACOOL Air Conditioner. N17 Model INSTRUCTION MANUAL. Rev. G 2015 Pentair Equipment Protection P/N

SPECTRACOOL Air Conditioner. N16 Model INSTRUCTION MANUAL. Rev. A 2016 Pentair Equipment Protection P/N

GENESIS Top-Mount Air Conditioner. HB16 Model INSTRUCTION MANUAL. Rev. J 2013 Pentair Equipment Protection P/N

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

SPECTRACOOL Air Conditioner

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. I 2017 Pentair Equipment Protection P/N

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

ClimaGuard Outdoor Heat Exchanger All Models

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

ADVANTAGE SERIES KXRP33 AIR-TO-AIR HEAT EXCHANGER

AIR CONDITIONER OPERATOR'S MANUAL

ADVANTAGE SERIES KXRP47 AIR-TO-AIR HEAT EXCHANGER

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner TRADITIONAL SERIES P47 P52 P59

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner TRIMLINE WNP28 SERIES

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner ADVANTAGE RP55 SERIES

RPI Industries, Inc.

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner GUARDIAN SERIES K2NA6C14DP50L

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner

RPI Industries, Inc.

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner NPT SERIES K_A6C_NPT47L

Blade Series Heat Exchanger Operation and Installation

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner WATER-COOLED RACK MOUNTED

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner INTEGRITY SERIES K_NA4C4P32L KNA6C4P32L

Intelligent Electronic Enclosure Thermal Management Systems

Manual For Panel Air Conditioner. Table of Contents

RPI Industries, Inc.

Panel Mounted Heat Exchangers by Dantherm, Inc.

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner DP SERIES K2A3C14DP50L

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner K2A3C8P36LFHN-1

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

SPECTRACOOL Air Conditioner. N28 Model INSTRUCTION MANUAL nvent Rev. D P/N

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

AIR CONDITIONER OPERATOR'S MANUAL. Keep This Manual With Air Conditioner DP SERIES K_A4C5DP33L

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

SPECTRACOOL Air Conditioner. G57 Model INSTRUCTION MANUAL. Rev. E 2014 Pentair Equipment Protection P/N

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

NEWGATE TECHNOLOGIES, INC.

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

The Da-Lite Difference.

M Series Fan Filter Units

User s Information and Installation Instructions

XT Series Thermostats

USER S OPERATING AND INSTRUCTION MANUAL

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

SPECTRACOOL Air Conditioner

SPECTRACOOL Air Conditioner. N36 Model INSTRUCTION MANUAL. Rev. N 2014 Pentair Equipment Protection P/N

Wax Base Heater & Dispenser

Rev. F 2014 Pentair Equipment Protection P/N Distributed by: McLean Parts. fax

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

Surna 25-Ton Chiller Operating & Maintenance Manual

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

User Manual. Commercial Chest Freezer User s Manual 360CF5, 360CF8, 360CF14, 360CF18

XC Portable Air Conditioning

SPECTRACOOL Air Conditioner

GENERAL PURPOSE REFRIGERATORS ABT-9R, ABT-14R, ABT-17R, ABT-20R, ABT-30R

Transcription:

PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167

TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION INSTRUCTIONS...4 TECHNICAL INFORMATION...4 Design Data... 4 DIMENSIONAL DRAWINGS... 5 Components List... 6 STANDARD WIRING DIAGRAM, 115 / 230 VOLT... 7 TIME DELAY RELAY OPTION WIRE DIAGRAM, 115 / 230 VOLT... 7 TEMPERATURE CONTROL... 8 PRINCIPLES OF OPERATION... 8 WATER USAGE... 8 Condenser... 8 Manual Reset High Pressure Limit Switch... 8 Water Valve... 8 Water... 9 MAINTENANCE...9 Compressor... 9 Evaporator Blower... 9 Refrigerant Loss... 9 Freezing and Draining the System... 9 WARRANTY...10 HOLD HARMLESS...11 NOTE: Some of the information in this manual may not apply if a special unit was ordered. If additional drawings for a special unit are necessary, they have been inserted. Contact Pentair Equipment Protection if further information is required. - 2-2013 Pentair Technical Products

RECEIVING THE AIR CONDITIONER Inspect the thermoelectric cooler. Check for concealed damage that may have occurred during shipment. Look for dents, scratches, loose assemblies, etc. Damage evident upon receipt should be noted on the freight bill. Damage should be brought to the attention of the delivering carrier -- NOT to Pentair Equipment Protection -- within 15 days of delivery. Save the carton and packing material and request an inspection. Then file a claim with the delivering carrier. Pentair Equipment Protection cannot accept responsibility for freight damages; however, we will assist you in any way possible. HANDLING & TESTING THE AIR CONDITIONER If it is necessary to place the air conditioner in a horizontal position after unpacking, be certain it is placed in an upright, vertical or mounting position for a minimum of five (5) minutes before operating. Never attempt to operate the air conditioner while it is horizontal or on its side, back or front. The refrigeration compressor is filled with lubricating oil. Running the compressor without oil in the lower part of the housing will cause permanent damage to the air conditioner. This also voids the warranty. TEST FOR FUNCTIONALITY BEFORE MOUNTING THE AIR CONDITIONER TO THE ENCLOSURE. Refer to the nameplate for proper electrical current requirements, then connect power cord to a properly grounded power supply. Minimum circuit ampacity should be at least 125% of the amperage shown in the design data section for the appropriate model. No other equipment should be connected to this circuit to prevent overloading. Connect to clean, pressurized water supply and provide drain. Operate the air conditioner for five (5) to ten (10) minutes. No excessive noise or vibration should be evident during this run period. The evaporator blower (enclosure air), and the compressor should be running. The compressor is provided with automatic reset thermal overload protection. This thermo-switch is located and mounted inside the plastic enclosure clipped to the compressor. The only time this switch should operate is when the compressor overheats due to ambient air temperatures exceeding nameplate rating or if enclosure dissipated heat loads exceed the rated capacity of the air conditioner. The thermal overload switch will actuate and stop compressor operation. The blower will continue to operate and water will continue to flow for a short period. The compressor will restart after it has cooled to within the thermal overload cut-in temperature setting. The unit will also shut down if water supply is interrupted. See WATER USAGE section. 2013 Pentair Technical Products - 3 -

INSTALLATION INSTRUCTIONS 1. Inspect air conditioner. Verify functionality before mounting the air conditioner, see HANDLING & TESTING THE AIR CONDITIONER on page 3 2. Using the cutout dimensions shown in this manual or the cutout template printed on the units shipping carton, prepare the air IN and air OUT openings, and mounting bolt hole pattern for the enclosure. 3. Using the gasket kit provided, install gaskets to air conditioner. See gasket kit illustration in this manual for proper location. 4. Mount air conditioner on enclosure using mounting bolts and screws provided. EZ-mount tabs can be used to hold unit on enclosure while mounting in place. Connect water inlet and outlet fittings to a clean pressurized water supply. Allow unit to remain upright for a minimum of five (5) minutes before starting. Caution! Air conditioner must be in upright position during operation. 5. Refer to top of nameplate for electrical requirements. Connect the power cord to a properly grounded power supply. Use of an extension cord is not recommended. Electrical circuit should be fused with slow blow or HACR circuit breaker. TECHNICAL INFORMATION DESIGN DATA Model Voltage Hertz Full Load Amps Phase BTU/Hr. @ 131 F Enclosure Temperature Maximum F Water Temperature Maximum Water Usage (GPM) Shipping Weight lb./kg CR43-0816-GWXXX 115 50/60 13.0 / 13/0 1 8500 90 1.5 137 / 62 CR43-0826-GWXXX 230 50/60 6.6 / 6.5 1 8500 90 1.5 137 / 62 -XXX will be replaced with a three-digit number designating all desired options. Consult the factory for specific model numbers. - 4-2013 Pentair Technical Products

DIMENSIONAL DRAWINGS 2013 Pentair Technical Products - 5 -

MOUNTING GASKET KIT MOUNTING CUTOUT DIMENSIONS Rear view of mounting gasket kit part number 43-2000-02 COMPONENTS LIST Part Description Part Number 115 Volt 230 Volt Blower, Evaporator 38-2019-04 38-2020-04 Capacitor, Compressor 10-1032-15 10-1032-18 Coil, Condenser Water 47-6121-00 47-6121-00 Coil, Evaporator 43-2002-01 43-2002-01 Compressor 10-1016-68 10-1026-80 Contactor (optional) 10-1005-41 10-1005-42 Filter/Dryer 52-6028-00 52-6028-00 Relay, Compressor Start 10-1028-14 10-1028-15 Relay, Time Delay, (optional) 10-1005-71 10-1005-71 Service Cord 52-6035-01 52-6035-74 Switch, Manual Reset Pressure 52-6104-48 52-6104-48 Thermal Overload, Compressor 10-1007-50 10-1007-49 Thermostat, SPST, 55-100F 10-1061-02 10-1061-02-6 - 2013 Pentair Technical Products

STANDARD WIRING DIAGRAM, 115 / 230 VOLT TIME DELAY RELAY OPTION WIRE DIAGRAM, 115 / 230 VOLT 2013 Pentair Technical Products - 7 -

TEMPERATURE CONTROL The electromechanical thermostat is factory preset to 75 F / 23 C. To change the temperature setting, remove the front cover. Use a standard screwdriver to adjust thermostat. For cooler temperatures turn clockwise, for warmer temperatures turn counterclockwise. PRINCIPLES OF OPERATION If electrical power to the air conditioner is interrupted and reapplied immediately, (within 3 to 5 seconds), the compressor may not restart due to the high back pressure of the compressor. It takes a minimum of one (1) minute after shut-down for the compressor suction and discharge pressures to equalize in order for the air conditioner to restart. Operating the air conditioner below the minimum ambient temperature or above the maximum ambient temperatures indicated on the nameplate voids all warranties. It is recommended that the warranty section of this manual be read in order to familiarize yourself with parameters of restricted operation. The moisture that the enclosure air can contain is limited. If moisture flows from the drain tube continuously this can only mean that ambient air is entering the enclosure. Be aware that frequent opening of the enclosure s door admits humid air which the air conditioner must then dehumidify. WATER USAGE CONDENSER The water cooled air conditioner uses water as the cooling medium for the condensing side of the hermetic refrigeration system. This water is passed through a heat exchanger that uses the cool water to lower the temperature of the hot gaseous refrigerant, causing it to condense. The water is warmed by this exchange of heat, and is passed out of the air conditioner at an elevated temperature. The inlet and outlet water fittings are located on the bottom of the air conditioner. A sealant is recommended when connecting the inlet and outlet water lines to prevent leakage. It is extremely important for the air conditioner to have an uninterrupted supply of clean cooling water. Interference with the water supply will cause the unit to automatically shut down and require manual reset. MANUAL RESET HIGH PRESSURE LIMIT SWITCH The manual reset high pressure limit switch is located behind the front cover. This limit switch interrupts compressor operation when condenser refrigerant exceeds 310 PSIG, which most frequently occurs as a result of the condenser water supply being reduced or shut down. After identifying and correcting the problem with the water supply to the unit, compressor operation can be restored by pushing the manual reset button located on the switch. WATER VALVE The valve that controls the flow of condensing water is also located behind the front cover. This valve modulates the flow of water to the condensing coil. Water flow varies according to a variety of loading conditions, including electrical load, inlet water temperature, ambient air temperature, cabinet construction, etc. The maximum flow rate in the DESIGN DATA is given for the conditions of maximum rated load, maximum water temperature, and maximum ambient temperature, and reflects the highest flow rate anticipated for the unit. NOTE: This valve has been preset at the factory for the correct operation of the unit. The setting of the valve should not be altered. - 8-2013 Pentair Technical Products

WATER The air conditioner water supply does not require special treatment, but care should be taken to avoid any gross contamination. Corrosives may cause leakage within the coil and water lines. Mineral rich water will cause scaling of the coil, degrading performance. Particulates may cause rapid erosion of the coil, and could result in clogging of the control valve. NOTE: A filter to clean the air conditioner water supply is recommended. If the temperature of the inlet water is higher than that shown in the DESIGN DATA, it will result in a higher flow rate, and may cause shut-down of the unit. High inlet water temperatures should be avoided. When the air conditioner is shut-down, either because of a thermostatic cut-out or a loss of power, the water flow should gradually diminish to zero. If water flow persists, it may indicate a malfunction of the control valve. Information on the specific valve employed is supplied with the air conditioner. MAINTENANCE COMPRESSOR The compressor requires no maintenance. It is hermetically sealed, properly lubricated at the factory and should provide years of satisfactory operating service. Should the refrigerant charge be lost, recharging ports (access fittings) on the suction and discharge sides of the compressor are provided for recharging and/or checking suction and discharge pressures. Under no circumstances should the access fitting covers be loosened, removed or tampered with. Breaking of seals on compressor access fittings during warranty period will void warranty on hermetic system. Recharging ports are provided for the ease and convenience of reputable refrigeration repair service personnel for recharging the air conditioner. EVAPORATOR BLOWER Blower motors require no maintenance. All bearings, shafts, etc. are lubricated during manufacturing for the life of the motor. REFRIGERANT LOSS Each air conditioner is thoroughly tested prior to leaving the factory to insure against refrigeration leaks. Shipping damage or microscopic leaks not found with sensitive electronic refrigerant leak detection equipment during manufacture may require repair or recharging of the system. This work should only be performed by qualified professionals, generally available through a local, reputable air conditioning repair or service company. Refer to the data on the nameplate which specifies the type of refrigerant and the charge size in ounces. Before recharging, make sure there are no leaks and that the system has been properly evacuated into a deep vacuum. FREEZING AND DRAINING THE SYSTEM WARNING The air conditioner can be severely damaged by freezing if not properly drained. Damage due to freezing is not covered by the warranty. If the unit is to be shipped to, or stored in an area that experiences climatic extremes, care must be taken to fully drain the unit to avoid freezing. The location of the drain is shown in the OUTLINE DRAWING. To completely drain the unit, it is recommended that 100 psi maximum compressed air be applied to the water inlet, while lifting the spring of the valve with a screwdriver to allow free passage of water. An alternate means would be to start the air conditioner and allow the refrigeration system pressure to open the valve while air pressure is applied to inlet. 2013 Pentair Technical Products - 9 -

WARRANTY Please note: Warranty effective at time of shipment. Pentair Equipment Protection warrants that all material and workmanship are free of defects in quality which impair the usefulness of the thermoelectric cooler or heat exchanger for a period of five (5) years for nonoperating parts, except for the filter; and for one (1) year for everything else when installed and operated under the following conditions: A. Maximum voltage variation no greater than plus or minus 10% of nameplate nominal rating. B. Maximum frequency variation no greater than plus or minus 3 Hz. of nameplate nominal rating. C. Must not exceed minimum and maximum stated temperatures on the nameplate. D. Not to exceed (BTU/Hr.) rating, including any heat sink, as indicated on the nameplate. E. The unit must not be restarted for a period of one (1) minute after intentional or accidental shut-off. (This does not apply to heat exchanger or filter fan.) Pentair Equipment Protection warrants that all material and workmanship are free of defects in quality which impair the usefulness of the filter fan package and all custom thermoelectric coolers and heat exchangers for a period of one (1) year, except for the filter, when installed and operated under conditions A, B, C and D as listed above. Not covered in this warranty is damage to the thermoelectric cooler or heat exchanger due to the introduction of other than the nameplate-designated refrigerant. Operation of any Pentair Equipment Protection product that has not been designed with proper protective coatings and/or options and is in an abnormal or corrosive environment voids the warranty. Prolonged operation with dirty filters also voids the warranty. Should any part prove defective within the above warranty period, the customer may choose to return the defective product that is under warranty to Pentair Equipment Protection for repair at no charge or the customer has the option to repair the defective products at his own expense and Pentair Equipment Protection will supply repair parts at no charge providing the defective part is returned and found to have failed under warranty. Parts supplied as warranty replacement parts will assume the balance of the warranty on the part returned for warranty consideration. Please be advised: According to the Federal Register, no person maintaining, servicing, repairing, or disposing of appliances may knowingly vent or otherwise release into the environment any class I or class II substance used as refrigerant. Pentair Equipment Protection assumes no liability beyond the repair or replacement of its own product. Customer modification of any Pentair Equipment Protection product voids this warranty. The purchaser assumes the responsibility of grounding the unit and installing it in accordance with local electrical and safety codes, as well as the National Electric Code (NEC) and OSHA. This express warranty constitutes the entire warranty with respect to the PRODUCT and IS IN LIEU OF ALL OTHERS, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OR MERCHANTABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO EVENT IS Pentair Equipment Protection RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER. - 10-2013 Pentair Technical Products

HOLD HARMLESS In consideration of purchase of equipment from Pentair Equipment Protection by a customer, Pentair Equipment Protection agrees to indemnify and hold harmless such customer and users with a defense, as to any claim, demand, statutory court cost, fees for attorney s services provided for below, and/ or judgment, for actual of alleged patent infringement in any country, arising out of the use, sale or advertisement of any equipment manufactured or sold by Pentair Equipment Protection to Pentair Equipment Protection s own specifications, provided that the customer or user shall promptly notify Pentair Equipment Protection in writing of any such claim or demand, provided further that Pentair Equipment Protection shall have the right and option to undertake and control the entire defense of such claim, or demand instituted against the customer or user, but limited to the products made or sold by Pentair Equipment Protection, through counsel selected by Pentair Equipment Protection, and to settle and pay any claim award arising out of such claim or demand, and provided further that the customer or user will provide such information and assistance as Pentair Equipment Protection may request subject to reimbursement by Pentair Equipment Protection for any out-of pocket expense incurred in providing such requested assistance. Liability of Pentair Equipment Protection for any infringement or claim thereof shall be limited to the above undertaking. 2013 Pentair Technical Products - 11 -

Pentair Equipment Protection 2100 Hoffman Way Minneapolis, MN 55303 USA +1.763.422.2211 +1.763.576.3200 PentairEquipmentProtection.com Rev. E 2013 Pentair Technical Products P/N 10-1008-167