For demanding applications in life sciences and labs, and as supplier to analysers, autoclaves, glassware washers.

Similar documents
NuPure LAB. Ultrapure and RO with PE Tank USER MANUAL

Large Direct-Pure EDI Water System. User Manual. RephiLe Bioscience, Ltd.

VWR Puranity PU 20 INSTRUCTION MANUAL

Direct-Pure Water System. User Manual

DISTILLATION. The Best Distillation Times Two! 4 FI-STREEM Tap/Pretreated 30 Liter Storage Reservoir WP54 50 Liter Storage Reservoir

Operating Instructions Thermo Scientific Barnstead MicroPure with storage tank Water Purification System

Aries - Operation & Maintenance Manual Lab Water Purification System

Storage Tanks and Accessories

User Manual. Milli-Q Integral 3/5/10/15 Systems

Direct-Q 3, 5, 8 system Direct-Q 3 UV, 5 UV, 8 UV system User manual

Operating instructions Thermo Scientific Barnstead MicroPure Water Purification System

WATER WITH QUALITY. Hygienic Water Treatment for Humidification Systems. Humidification and evaporative cooling

Operating Manual. Reverse Osmosis Water Purifier. MELAdem 55

Hygiene within nursing homes, geriatric wards, rehabilitation centres automatic washer disinfectors

Water Purification 85

HYGIENE AND SERVICE. The Pur water treatment system

Water Purification. Quality distilled... the most reliable method of purifying water 81

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

Let s talk about wa. Filtering, water softening, semi demineralisation or full demineralisation are the options open.

PASSION THAT DRIVES PERFORMANCES. WASHINGSOLUTIONS

MILLI-Q ADVANTAGE A10 SYSTEM USER MANUAL

A SYSTEM FOR HIGH-PERFORMANCE HUMIDIFICATION

MELA dem Everything you need for water treatment

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

RIOS 3 USER MANUAL MILLIPORE

Your Health, our Technology AWD655. Instrument Washer Disinfector

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

User Manual. Milli-Q Direct 8/16 System

PRODUCT SELECTION GUIDE

Condumax CLS16 and CLS16D

The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models.

Constant climate chambers

PURELAB Classic - US. Operator Manual

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

PURELAB UHQ PS Operator Manual

BARNSTEAD THERMOLYNE CORPORATION. NANOpure Infinity UF OPERATING MANUAL AND PARTS LIST. Series 898 D D LT898X1 5/11/98

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

STERIDENT, STERIMAT, STERIMAT PLUS

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

WASHER DISINFECTORS ISO ISO ISO 9001

Gemini - Operation & Maintenance Manual Lab Water Purification System

PG 8535 Perfect Reprocessing

WATER TREATMENT HYDROLINE

CENTRAL STERILE SUPPLY DEPARTMENT

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

TEMPLATE ASSISTED CRYSTALLIZATION. Presented By Ryan Lessing 11/13/2014

Cassia Siamia ADVANCED MODELS AQDD-XL-RSH SERIES. MINI QUARTZ DISTILLER Standard Panel Series

Dental instrument Washer Disinfectors

ice 3000 Series Atomic Absorption Spectrometers

Washer disinfectors Small - Medium range

MADE IN ITALY SERVICE INNOVATION QUALITY RELIABILITY

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

Glassware Washers. WM Series. Efficient washing results for laboratory glassware

Water Stills. The result of decades of experience and technical innovation: four individually applicable product ranges with 14 different models.

QUICK SET-UP GUIDE LX-5085-QS. Xe-2 Xenon Test Chamber

CEHA Fall Chloride Workshop. Chloride Treatment Options Presented by Paul Hurlbut Professional Water Systems, Inc.

ENVAIR lab CO2 Incubator

STERILAB Steam sterilizer with gravitation de-aeration (without vacuum pump) for laboratory purposes.

VS LD series vertical steam sterilizers

GROWMAX WATER Perfect Water for Plants and Gardens

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Condensate Recovery and Return System SDR A

IC Professional Detector

The power of innovation. For better media preparation. Media preparators Systec MediaPrep.

WM-450-PT WM-900-PT Commercial Wall Mounted Reverse Osmosis

PART 1 - GENERAL 1.1 WORK INCLUDED

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

Atomic Absorption Spectrophotometer AAS 2320D EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Your Health, our Technology AWD655. Instruments Washer Disinfector

UNICLEAN sl. Washer Disinfector for Labs. protecting human health

WASHER DISINFECTORS ISO ISO ISO 9001

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS

Checklist for EASYZON Chlorine dioxide system

Custom modular design to fit any application

AZTECA A LITRE STERILISER

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

requirements can be equipped with an additional product temperature control probe, and with a printer.

Ultrasonic From delicate microsurgery instruments to heavy duty sets

PURITY GRADES OF LAB REAGENTS

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Rotavapor R-220 Pro Technical data sheet

Rotavapor R-220 Pro Technical data sheet

2 OZONFILT And Bono Zon Ozone Plants

New Generation KBF 240 series

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Application of a Reagentless Direct Conductivity Online TOC Analyzer for Clean-in-Place Verification

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

Precision Temperature Control. Pulse Free Pump. Column Oven. Superb Performance Ion Chromatography. Leak Detector. Modular Flexibility

LAUDA WK class. Reliable, large selection of models, compact construction

Washer disinfectors Small - Medium range

Thermo Scientific Critical Environment Products. Where clean is critical every container - every time

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

HPLC Column Ovens and Temperature Controllers

High-Pressure Atomizing System


Matachana Low Temperature Steam and Formaldehyde 130 LF Sterilizer

TECHNICAL SPECIFICATION 44 and 55 Compact Sterilizer Series

2 OZONFILT And Bono Zon Ozone Plants

Transcription:

Omnia pure and ultrapure water systems Convenient. Compact. Adaptable. For demanding applications in life sciences and labs, and as supplier to analysers, autoclaves, glassware washers.

H 2 O pure. Pure and ultrapure water For QC, R & D and analytical labs in science, pharmaceutics and industries. Whether for demanding applications in life sciences and chemical analysis or for supplying analysers, autoclaves and laboratory glassware washers with seven systems, the new stakpure Omnia series provides the ideal solution for any task and satisfies international water standards such as ASTM, ISO 3696 and CLRW (CLSI). The systems are characterized by their economy and flexibility in many applications. OmniaTap OmniaPure OmniaLab ED + OmniaTap OmniaLab ED + OmniaLab ED OmniaLab UP OmniaLab DS OmniaLabRO Water quality Type I ultrapure water Type II pure water Type III water from reverse osmosis daily water quantity < 50 liter 20 100 liter > 50 liter < 50 liter > 50 liter > 50 liter feedwater tap water pretreated water pretreated water tap water pretreated water pretreated water applications AAS (Atomic Absorption Spectroscopy) Reagent Preparation + Feeding of IC (Ion Chromatography) Sample Dilution ultrapure water ICP (Inductively Coupled Plasma) Buffer and media preparation systems: ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Photometry + Spectrophotometry - laboratory HPLC (High-performance liquid chromatography) RIA (Radioimmunoassay) washers HPLC + (Ultratrace Element Analysis) ELISA (Enzyme-linked - autoclaves Electrochemistry and Electrophoresis immunosorbent assay) - sterilizers TOC-Analysis Pathology + Histology - steam Molecular- and Microbiology General chemistry generator cell culture mediums Feeding of ultrapure water systems: - climatic - laboratory washers (OmniaLab) chamber - autoclaves + sterilizers 2

Water quality standards For various fields of use and requirements. International Organization for Standardization (ISO) ISO 3696:1987 distinguishes between three degrees of purity for water for analytical purposes in laboratories. Parameter Grade 1 Grade 2 Grade 3 ph value at 25 ºC 5.0 7.0 (μs/cm at 25 ºC) 0.1 1.0 5.0 Oxidizable matter, oxygen content (mg/l, max.) 0.08 0.4 Absorption at 254 nm and a lenght of 1 cm 0.001 0.01 (absorption units, max.) Residue after evaporation by heating to 110 ºC (mg/kg, max.) 1 2 Silicon content (mg/l, max.) 0.01 0.02 Clinical Laboratory Standards Institute (CLSI) This institute defined the quality requirements of water for clinical laboratories. The regulations that were valid up to 2006 (NCCL types 1, 2 and 3) but were then invalidated by the requirement that water must be suitable for the intended usage. Only the degree of purity of so-called Clinical laboratory reagent water (CLRW) is described. Parameter Resistance TOC Bacteria Particle content CLRW 10 MΩ x cm < 500 ppb < 10 CFU/ml Inline 0.2 μm-filter American Society for Testing and Materials (ASTM) The ASTM D1193-06 (2011) deals with the requirements for chemical analyses and physical tests. Type Grade Resistance ph TOC Sodium Chloride Silicon Bacteria Endotoxins (μs/cm), max. (MΩ x cm), min. (μg/l), max. (μg/l), max. (μg/l), max. (μg/l), max. (CFU/ml), max. (EU/ml), max. Pure water Pure water Pure water Ultrapure Water I* 0.056 18.0 50 1 1 3 I* A 0.056 18.0 50 1 1 3 10/1000 0.03 I* B 0.056 18.0 50 1 1 3 10/100 0.25 I* C 0.056 18.0 50 1 1 3 100/10 II 1.0 1.0 50 5 5 3 II A 1.0 1.0 50 5 5 3 10/1000 0.03 II B 1.0 1.0 50 5 5 3 10/100 0.25 II C 1.0 1.0 50 5 5 3 100/10 III 0.25 4.0 200 10 10 500 III A 0.25 4.0 200 10 10 500 10/1000 0.03 III B 0.25 4.0 200 10 10 500 10/100 0.25 III C 0.25 4.0 200 10 10 500 100/10 IV 5.0 0.2 5.0 8.0 50 50 IV A 5.0 0.2 5.0 8.0 50 50 10/1000 0.03 IV B 5.0 0.2 5.0 8.0 50 50 10/100 0.25 IV C 5.0 0.2 5.0 8.0 50 50 100/10 * Using an appropriate 0,2 μm membrane filter. 3

Omnia Pure and ultrapure water systems Convenient. Compact. Adaptable. OptiFill Dispenser is standard Can be swivelled and height adjusted Real time display of all operating and performance parameters USP conform OneHandOperation-Dispenser Clear control with graphic display Removable & ergonomic shaped Safe password access acc. to GLP Press button withdrawal Language switch German / English GLP conform data acquisition via an RS-232 interface Setting possibilities for conductivity in MΩ x cm or µs/cm Leakage sensor is standard Automatic voltage adjustment 4

The Omnia series is extremely convenient to use. All devices are fitted with the Optifill one-hand dispenser with integrated control- and monitoring unit. One-handed operation, removable, can be swivelled and height-adjusted, and with a flexible connection for easy water dispensing into any type of container. Separate from the production unit. The external dispenser can be space sparingly wall-fitted or flexibly placed on the lab bench. Place the production unit under the bench to save valuable space in your lab. Match the positioning to your lab environment with the external OptiFill stand/wall dispenser and monitoring unit. Either practical on a bench or space-saving on a wall. The ergonomic shaped dispenser is easily operable. The easily accessible control and service cover ensures that consumables can be replaced in seconds. 5

OmniaPure The specialist. For H 2 O pure type I. When your need is for highest quality pure water that fulfils the demands of analytical and life science laboratory requirements, then one of these OmniaPure systems type will be right for you. You can configurate it. The incorporated pre-treatment constantly ensures the reliability of your experimental results and reduces running costs. Features OptiFill dispenser is standard Spent filters are simply and quickly changed Leakage sensor is standard + Real time TOC monitoring Integrated pressure reducer is standard Precise volume control Ready-to-use, including filter cartridges Dispenser on the bench Dispenser on the wall One hand operation Easy water dispensing Fits neatly on the wall Flexible on a work surface 6

Specifications OmniaPure OmniaPure UV UV-TOC OmniaPure UV/UF UV-TOC/UF Type I µs/cm 0.055 0.055 0.055 Resistance MΩ x cm 18.2 18.2 18.2 TOC-value* ppb 5 10 1 5 1 5 TOC monitor - / yes / yes Dispensing performance l/min. up to 2 up to 2 up to 1.6 Endotoxins* EU/ml - - < 0.001 RNase* ng/ml - - < 0.01 DNase* pg/µl - - < 4 Particles**/ml < 1 < 1 < 1 Bacteria** CFU/ml < 0.1 < 0.1 < 0.1 Feedwater requirements Water prepared by ion exchange, reverse osmosis, electrodionisation or distillation Feedwater temperature C + 2 up to 35 + 2 up to 35 + 2 up to 35 Input conductivity µs/cm < 30 < 30 < 30 TOC-value ppb < 50 < 50 < 50 Technical data Operating pressure bar 0.5 6 0.5 6 0.5 6 Supply voltage Volt/Hz 90 240/50 60 90 240/50 60 90 240/50 60 Connected load kw 0.1 0.1 0.1 Connector size 3/4" 3/4" 3/4" Ambient temperature C + 2 up to + 35 + 2 up to + 35 + 2 up to + 35 Dimensions*** W x H x D mm 390 x 720 x 525 390 x 720 x 525 390 x 720 x 525 Dimensions production unit W x H x D mm 390 x 480 x 380 390 x 480 x 380 390 x 480 x 380 Dimensions OptiFill Wall dispenser 100 x 520 x 460 100 x 520 x 460 100 x 520 x 460 Dimensions OptiFill Bench dispenser 140 x 580 x 520 140 x 580 x 520 140 x 580 x 520 Weight kg 19 20 20 * in dependence on the feedwater quality ** with sterilizing filter 0.2 µm *** with OptiFill Dispenser Article no. System type* Standard Article no. System type Production unit + Wall dispenser*/** Article no. System type Production unit + Bench dispenser*/** Typical applications 18200001 OmniaPure 18200011 OmniaPure-W 18200021 OmniaPure-T AAS, IC, ICP, buffers and media preparation 18200002 OmniaPure UV 18200012 OmniaPure-W UV 18200022 OmniaPure-T UV Ultra-trace analysis, ICP-MS, HPLC, TOC-analysis 18200003 OmniaPure UV/UF 18200013 OmniaPure-W UV/UF 18200023 OmniaPure-T UV/UF Life science and microbiology, cell culture media 18200004 OmniaPure UV-TOC 18200014 OmniaPure-W UV-TOC 18200024 OmniaPure-T UV-TOC Ultra-trace analysis, ICP-MS, HPLC, TOC-analysis 18200005 OmniaPure UV-TOC/UF 18200015 OmniaPure-W UV-TOC/UF 18200025 OmniaPure-T UV-TOC/UF Life science and microbiology, cell culture media * filter cartridges and sterile filter capsule 0.2 µm included ** The Omnia production unit can either be installed on a bench, on a wall or under the bench. Flow chart OmniaPure UV-TOC/UF meaurement Pre-treatment meaurement after UV disinfection UV-Unit measurement ultrapure water Accessories 19200300 Wall mount Omnia 19200056 Disinfection kit Omnia 19200057 Disinfectant Omnia 3 Pc./Pkg. Feedwater Pump Ultrafiltrations module Rinse water Sterile filter / Bio filter capsule Dispensing Typ I Pre-treatment cartridge Ultrapure water cartridge 7

OmniaTap The Allrounder. For H 2 O pure types I + II. OmniaTap is the ideal system when both pure water and ultrapure water are required, but in relatively small amounts. The ability to provide both types from a single system results from the combination of ultramodern purification technologies. These also make it possible to connect the system directly to tap water. A press on the dispenser button activates dispensing of ultrapure water type I via the digital dispenser control. The recirculation of the pure water held in the installed 10 litre tank keeps it permanently at type II quality. The pure water tank has a second outlet for feeding downstream end users. Features OptiFill dispenser is standard Pretreatment set for direct connection to tap water 10-litres pure water tank Tank volume display in percent Simple and economical filter replacement Leakage sensor is standard Ready-to-use, including filter cartridges One hand operation Easy water dispensing Flexible on a work surface 8

Specifications OmniaTap OmniaTap UV OmniaTap UV/UF Type II Pure water performance l/h at 15 C 6 or 12 6 or 12 6 or 12 µs/cm 0.067 0.1 0.067 0.1 0.067 0.1 Resistance MΩ x cm 15 10 15 10 15 10 Pure water tank pressurized outlet optional optional optional Type I µs/cm 0.055 0.055 0.055 Resistance MΩ x cm 18.2 18.2 18.2 TOC-value* ppb 5 10 1 5 1 5 Dispensing performance l/min. up to 2 up to 2 up to 1.6 Endotoxins* EU/ml - - < 0.001 Particles**/ml < 1 < 1 < 1 Bacteria** CFU/ml < 0.1 < 0.1 < 0.1 Feedwater requirements Tap water according to DIN 2000 Feedwater temperature C + 2 up to 35 + 2 up to 35 + 2 up to 35 Manganese and iron content mg/l < 0.05 < 0.05 < 0.05 Free chlorine content mg/l < 0.1 < 0.1 < 0.1 Silt density index (SDI) max. 3 max. 3 max. 3 Technical data Operating pressure bar 2 6 2 6 2 6 Supply voltage Volt/Hz 90 240/50 60 90 240/50 60 90 240/50 60 Connected load kw 0.1 0.1 0.1 Connector size 3/4" 3/4" 3/4" Ambient temperature C + 2 up to + 35 + 2 up to + 35 + 2 up to + 35 Dimensions*** W x H x D mm 390 x 720 x 615 390 x 720 x 615 390 x 720 x 615 Weight kg 20 21 21 * in dependence on the feedwater quality ** with sterilizing filter 0.2 µm *** with OptiFill Dispenser Article no. System type* Typical applications 18200051 OmniaTap 6 AAS, IC, ICP, buffers and media preparation 18200101 OmniaTap 12 AAS, IC, ICP, buffers and media preparation 18200052 OmniaTap 6 UV Ultra-trace analysis, ICP-MS, HPLC, TOC 18200102 OmniaTap 12 UV Ultra-trace analysis, ICP-MS, HPLC, TOC 18200053 OmniaTap 6 UV/UF Life science and microbiology, cell culture media 18200103 OmniaTap 12 UV/UF Life science and microbiology, cell culture media Accessories 19200300 Wall mount Omnia 19200056 Disinfection kit Omnia 19200057 Disinfectant Omnia 3 pcs./pack 19200021 Pre-treatment unit OmniaTap 10 * RO cartridge, ultrapure water cartridge, sterile filter capsule 0.2 μm, sterile overflow and sterile vent filter included measurement RO Tap water Outlet measurement Ultrapure water Circulation Booster Rinse water RO cartridge Flow chart OmniaTap UV/UF UV-Unit Ultrapure water cartridge Ultrafiltration module Dispensing Type I Sterile filter / Bio filter capsule Tank Dispensing Type II 9

OmniaLab ED+ The big one. For H 2 O pure types I + II. OmniaLab ED+ is the system of choice when both pure water and ultrapure water are needed for the entire laboratory. The system complies with international water standards such as ASTM, ISO 3696 and CLSI. The economy of it is maximized by the inclusion of a continuously self-regenerating electrodeionizer, without having to give any demanding analytical applications a pass. Further to this, the OmniLab ED+ - system holds 100 liters of pure water Type II ready for withdrawal in a storage tank with quality recirculation. It is so predestined for supplying autoclaves or lab washing machines and the dispensing of Type 1 tultra pure water for analytical and bioscience applications. Features OptiFill dispenser is standard Continuous residual salts removal by electro-deionization 100 litre storage tank with recirculation and pressure outlet Tank volume display in percent Tank volume can be modularly increased Simple, cost-effective filter replacement Leakage sensor is standard One hand operation Easy water dispensing Flexible on a work surface Tank fits spacesavingly under the bench-top 10

Specifications OmniaLab ED+ 20 OmniaLab ED+ 40 OmniaLab ED+ 70 Type II Pure water performance l/h at 15 C 20 40 70 μs/cm 0.067 1 0.067 1 0.067 1 Resistance M Ω x cm 15 1 15 1 15 1 Silicate removal* % 99.9 99.9 99.9 Pure water tank pressurized outlet yes yes yes Type I μs/cm 0.055 0.055 0.055 Resistance M Ω x cm 18.2 18.2 18.2 TOC-value* ppb (with UV-unit) 1 5 1 5 1 5 Dispensing performance dispenser l/min. up to 2 up to 2 up to 2 Particles**/ml < 1 < 1 < 1 Bacteria** CFU/ml < 0.1 < 0.1 < 0.1 Feedwater requirements Softened water according to DIN 2000 Feedwater temperature C + 2 up to 35 + 2 up to 35 + 2 up to 35 Manganese and iron content mg/l < 0.05 < 0.05 < 0.05 Free chlorine content mg/l < 0.1 < 0.1 < 0.1 Silt density index (SDI) max. 3 max. 3 max. 3 Technical data Operating pressure bar 2 6 2 6 2 6 Supply voltage Volt/Hz 90-240/50-60 90-240/50-60 90-240/50-60 Connected load kw 0.25 0.25 0.25 Connector size 3/4" 3/4" 3/4" Ambient temperature C + 2 up to + 35 + 2 up to + 35 + 2 up to + 35 Dimensions Tower*** W x H x D mm 511 x 1520 x 575 511 x 1520 x 575 511 x 1520 x 575 Dimensions Base cabinet tank mm 511 x 800 x 575 511 x 800 x 575 511 x 800 x 575 Weight kg 43 43 45 * in dependence on the feedwater quality ** with sterilizing filter 0.2 μm *** with OptiFill Dispenser Article no. System type* Typical applications 18700020 OmniaLab ED+ 20 Feedwater for autoclaves and laboratory washers 18700040 OmniaLab ED+ 40 Feedwater for autoclaves and laboratory washers 18700070 OmniaLab ED+ 70 Feedwater for autoclaves and laboratory washers * RO cartridge, ultrapure water cartridge, sterile filter capsule 0.2 μm, sterile overflow and sterile vent filter + CO 2 absorber included Accessories 16125000 Single water softener WEA 32 MixMulti 19200021 Pre-treatment unit OmniaLab 10 19200050 UV Flow through disinfection 254 nm 19200052 UV Unit for TOC reduction 254 nm 16561201 External pressure booster SC 3000 Flow chart OmniaLab ED+ 40 with UV-unit + tank disinfection Feedwater measurement RO Outlet measurement ultrapure water Sterile filter Dispensing Pressure outlet Ultrapure water cartridge Circulation UV-Unit ED-Module CEM Feed Feed Feed AEM CEM Cl - Cl - Na+ AEM Booster measurement ED UV tank disinfection Cl - Cl - Tank RO- Cartridge Outlet Electrodeionization module Product Cation Exchange Resin Reject Product Anion Exchange Rein 11

OmniaLab ED The efficient one. For H 2 O pure type II. OmniaLab ED is the efficient solution when high quality pure water Type II is required for the complete lab supply. It is compliant with international water standards, such as ASTM, ISO 3696, CLRW (CLSI), and the combination with continual self-regenerating electro-deionization brings maximized economy. Further to this, the OmniaLab ED system holds 100 liters of pure water in a storage tank with quality recirculation, ready to supply lab equipment. OmniaLab ED is the efficient one for supplying autoclaves, lab machines and ultra-pure water systems. Features OptiFill dispenser is standard Continuous residual salts removal by electro-deionization 100 litre storage tank with recirculation and pressure outlet Tank volume display in percent Tank volume can be modularly increased Simple, cost-effective filter replacement Leakage sensor is standard One hand operation Easy water dispensing Flexible on a work surface Tank fits spacesavingly under the bench-top 12

Specifications OmniaLab ED 20 OmniaLab ED 40 OmniaLab ED 70 Type II Pure water performance l/h at 15 C 20 40 70 * µs/cm 0.1 1 0.1 1 0.1 1 Resistance* MΩ x cm 10 1 10 1 10 1 TOC-value* ppb < 30 < 30 < 30 Silicate removal* % > 99 > 99 > 99 Dispensing performance dispenser l/min. up to 2 up to 2 up to 2 Particles**/ml < 1 < 1 < 1 Bacteria** CFU/ml < 0.1 < 0.1 < 0.1 Pure water tank pressurized outlet yes yes yes Feedwater requirements Softened water according to DIN 2000 Feedwater temperature C + 2 up to 35 + 2 up to 35 + 2 up to 35 Manganese and iron content mg/l < 0.05 < 0.05 < 0.05 Free chlorine content mg/l < 0.1 < 0.1 < 0.1 Silt density index (SDI) max. 3 max. 3 max. 3 Technical data Operating pressure bar 2 6 2 6 2 6 Supply voltage Volt/Hz 90-240/50-60 90-240/50-60 90-240/50-60 Connected load kw 0.25 0.25 0.25 Connector size 3/4" 3/4" 3/4" Ambient temperature C + 2 up to + 35 + 2 up to + 35 + 2 up to + 35 Dimensions Tower*** W x H x D mm 511 x 1520 x 575 511 x 1520 x 575 511 x 1520 x 575 Dimensions Base cabinet tank mm 511 x 800 x 575 511 x 800 x 575 511 x 800 x 575 Weight kg 41 41 43 * in dependence on the feedwater quality ** with sterilizing filter 0.2 μm *** with OptiFill Dispenser Article no. System type* Typical applications 18700021 OmniaLab ED 20 Feedwater for autoclaves, laboratory washers and ultrapure water systems 18700041 OmniaLab ED 40 Feedwater for autoclaves, laboratory washers and ultrapure water systems 18700071 OmniaLab ED 70 Feedwater for autoclaves, laboratory washers and ultrapure water systems * RO cartridge, sterile filter capsule 0.2 μm, sterile overflow and sterile vent filter + CO 2 absorber included Accessories 16125000 Single water softener WEA 32 MixMulti 19200020 Pre-treatment unit OmniaLab 10" 19200050 UV Tank disinfecting unit 254 nm 19200051 UV Flow through disinfection 254 nm 16561201 External pressure booster SC 3000 Flow chart OmniaLab ED 40 with UV Flow through + tank disinfection Feedwater measurement RO Outlet Sterile filter Dispensing Circulation UV Disinfection Pressure outlet ED-Module CEM Feed Feed Feed AEM CEM Cl - Cl - Na+ AEM Booster measurement ED UV tank disinfection Tank Cl - Cl - RO- Cartridge Outlet Electrodeionization module Product Cation Exchange Resin Reject Product Anion Exchange Rein 13

OmniaLab UP The constant one. For H 2 O pure type II. OmniaLab UP is the system of choice when you need a constant supply of high-quality water in laboratories. For this, OmniaLab UP holds 100 litres of type II pure water in reserve in a storage tank with quality recirculation. It is an optimal supplier to autoclaves, lab rinsing machines and ultrapure water systems. The water produced conforms to international medical technology water standards such as ASTM, ISO 3696 and CLRW (CLSI). Features OptiFill Dispenser is standard 100 l tank with quality recirculation and pressure outlet Tank volume display in percent Tank volume can be modularly increased Simple, cost-effective filter replacement Leakage sensor is standard One hand operation Easy water dispensing Flexible on a work surface Tank fits spacesavingly under the bench top 14

Specifications OmniaLab UP 20 OmniaLab UP 40 Type II Pure water performance l/h at 15 C 20 40 μs/cm 0.067 0.1 0.067 0.1 Resistance M Ω x cm 15 10 15 10 Dispensing performance dispenser l/min. up to 2 up to 2 Pure water tank pressurized outlet yes yes Particles*/ml < 1 < 1 Bacteria* CFU/ml < 0.1 < 0.1 Feedwater requirements Softened or hardness-stabilized water according to DIN 2000 Feedwater temperature C + 2 up to 35 + 2 up to 35 Manganese and iron content mg/l < 0.05 < 0.05 Free chlorine content mg/l < 0.1 < 0.1 Silt density index (SDI) max. 3 max. 3 Technical data Operating pressure bar 2 6 2 6 Supply voltage Volt/Hz 90-240/50-60 90-240/50-60 Connected load kw 0.1 0.1 Connector size 3/4" 3/4" Ambient temperature C + 2 up to + 35 C + 2 up to + 35 C Dimensions Tower** W x H x D mm 511 x 1520 x 575 511 x 1520 x 575 Dimensions Base cabinet tank mm 511 x 800 x 575 511 x 800 x 575 Weight kg 40 40 * with sterilizing filter 0.2 μm ** with OptiFill Dispenser Article no. System type* Typical applications 18600020 OmniaLab UP 20 Feedwater for autoclaves and laboratory washers 18600040 OmniaLab UP 40 Feedwater for autoclaves and laboratory washers * RO cartridge, pure water cartridge, sterile filter capsule 0.2 μm, sterile overflow and sterile vent filter + CO 2 absorber included. Accessories 19200020 Pre-treatment unit OmniaLab 10 19200050 UV tank disinfection unit 254 nm 19200051 UV Flow through disinfection 254 nm 16561201 External pressure booster SC 3000 Flow chart OmniaLab UP 40 with UV Flow through + tank disinfection Feedwater Outlet measurement RO Pressure outlet Circulation measurement Ultrapure water UV tank disinfection Booster Sterile filter Dispensing Tank RO- Cartridge UV Disinfection Pure water cartridge Tank outlet 15

OmniaLab DS The reliable one. For H 2 O pure type II + CLRW (CLSI). When safety is first priority and the quality of the purification decides the quality of results, then the OmniaLab DS system is the perfect solution. Even for large pure water quantities of up to 80 l/h, OmniaLab DS guarantees international water standards compliance. The combination of regenerative polishing cartridge and an optional emergency supply makes this system extremely reliable for supplying clinical analytical systems, as well as for feeding water to steam sterilizers and washer-disinfectors. Features OptiFill Dispenser is standard 100 l tank with quality recirculation and pressure outlet Tank volume display in percent Tank volume can be modularly increased Simple, cost-effective filter replacement Leakage sensor is standard Emergency supply (optional) Degassing unit (optional) One hand operation Easy water dispensing Flexible on a work surface Tank fits spacesavingly under the bench top 16

Specifications OmniaLab DS 20 OmniaLab DS 40 OmniaLab DS 60 OmniaLab DS 80 Type II + CLRW (CLSI) DIN EN 285 + ISO EN 15883 Pure water performance l/h at 15 C 20 40 60 80 μs/cm 0.1 1.0 0.1 1.0 0.1 1.0 0.1 1.0 Resistance M Ω x cm 10 1 10 1 10 1 10 1 Dispensing performance dispenser l/min. up to 2 up to 2 up to 2 up to 2 Pure water tank pressurized outlet yes yes yes yes Particles*/ml < 1 < 1 < 1 < 1 Bacteria* CFU/ml < 0.1 < 0.1 < 0.1 < 0.1 Feedwater requirements Softened or hardness-stabilized water according to DIN 2000 Feedwater temperature C + 2 up to 35 + 2 up to 35 + 2 up to 35 + 2 up to 35 Manganese and iron content mg/l < 0.05 < 0.05 < 0.05 < 0.05 Free chlorine content mg/l < 0.1 < 0.1 < 0.1 < 0.1 Silt density index (SDI) max. 3 max. 3 max. 3 max. 3 Technical data Operating pressure bar 2 6 2 6 2 6 2 6 Supply voltage Volt/Hz 90-240/50-60 90-240/50-60 90-240/50-60 90-240/50-60 Connected load kw 0.1 0.1 0.1 0.1 Connector size 3/4" 3/4" 3/4" 3/4" Ambient temperature C + 2 up to + 35 + 2 up to + 35 + 2 up to + 35 + 2 up to + 35 Dimensions Tower** W x H x D mm 511 x 1520 x 575 511 x 1520 x 575 511 x 1520 x 575 511 x 1520 x 575 Dimensions Base cabinet tank mm 511 x 800 x 575 511 x 800 x 575 511 x 800 x 575 511 x 800 x 575 Weight kg (without polishing cartridge) 39 39 40 40 * with sterilizing filter 0.2 μm ** with OptiFill Dispenser Article no. System type Typical applications 18800020 OmniaLab DS 20 Feedwater for analyzers, autoclaves and laboratory washers 18800040 OmniaLab DS 40 Feedwater for analyzers, autoclaves and laboratory washers 18800060 OmniaLab DS 60 Feedwater for analyzers, autoclaves and laboratory washers 18800080 OmniaLab DS 80 Feedwater for analyzers, autoclaves and laboratory washers * RO cartridge, stainless steel polishing cartridge, sterile filter capsule 0.2 μm, sterile overflow and sterile vent filter + CO 2 absorber included Accessories 19200020 Pre-treatment unit OmniaLab 10 19200050 UV tank disinfection unit 254 nm 19200051 UV Flow through disinfection 254 nm 12280050 Replacement/second polishing cartridge type DS 2800 RV 19200040 Emergency supply 19200041 Degassing unit 16561201 External pressure booster SC 3000 Flow chart OmniaLab DS 80 with UV Flow through + tank disinfection + degassing unit + emergency supply Feedwater Booster measurement RO Outlet UV tank disinfection Tank Circulation measurement Ultrapure water Degassing unit Polishing cartridge Pressure outlet Dispensing RO- Cartridge RO- Cartridge Tank outlet UV disinfection Emergency supply (optional) 17

OmniaLab RO The big one. For H 2 O pure type III. OmniaLab RO fulfils your requirement when you have a needof a constant large volume of reverse osmosis water. For this, OmniaLab RO holds 100 litres in reserve in a storage tank. It is an optimal supplier to autoclaves, lab rinsing machines, air humidifiers and ultrapure water systems. Features OptiFill Dispenser is standard With 100 l pure water tank Tank volume display in percent Tank volume can be modularly increased Leakage sensor is standard One hand operation Easy water dispensing Flexible on a work surface Tank fits spacesavingly under the bench top 18

Specifications OmniaLab RO 20 OmniaLab RO 40 OmniaLab RO 60 OmniaLab RO 80 Type III Pure water performance l/h at 15 C 20 40 60 80 RO membrane retention rate in % (ions. germs and bacteria) > 98 > 98 > 98 > 98 Feedwater requirements Softened or hardness-stabilized water according to DIN 2000 Feedwater temperature C + 2 up to 35 + 2 up to 35 + 2 up to 35 + 2 up to 35 Manganese and iron content mg/l < 0.05 < 0.05 < 0.05 < 0.05 Free chlorine content mg/l < 0.1 < 0.1 < 0.1 < 0.1 Silt density index (SDI) max. 3 max. 3 max. 3 max. 3 Technical data Operating pressure bar 2 6 2 6 2 6 2 6 Supply voltage Volt/Hz 90-240/50-60 90-240/50-60 90-240/50-60 90-240/50-60 Connected load kw 0.1 0.1 0.1 0.1 Connector size 3/4" 3/4" 3/4" 3/4" Ambient temperature C + 2 up to + 35 + 2 up to + 35 + 2 up to + 35 + 2 up to + 35 Dimensions Tower* W x H x D mm 511 x 1520 x 575 511 x 1520 x 575 511 x 1520 x 575 511 x 1520 x 575 Dimensions Base cabinet tank mm 511 x 800 x 575 511 x 800 x 575 511 x 800 x 575 511 x 800 x 575 Weight kg 38 38 40 40 * with OptiFill Dispenser Article no. System type Typical applications 18500020 OmniaLab RO 20 Feedwater for autoclaves and laboratory washers, ultrapure water systems and air humidifiers 18500040 OmniaLab RO 40 Feedwater for autoclaves and laboratory washers, ultrapure water systems and air humidifiers 18500060 OmniaLab RO 60 Feedwater for autoclaves and laboratory washers, ultrapure water systems and air humidifiers 18500080 OmniaLab RO 80 Feedwater for autoclaves and laboratory washers, ultrapure water systems and air humidifiers Accessories 19200020 Pre-treatment unit OmniaLab 10 19200050 UV tank disinfection unit 254 nm 16561201 External pressure booster SC 3000 Flow chart OmniaLab RO 80 with tank disinfection Feedwater Outlet measurement RO UV tank disinfection Booster Dispensing Tank Pressure outlet Tank outlet Dispensing RO- Cartridge RO- Cartridge 19

stakpure GmbH Auf dem Kesseling 11 D 56414 Niederahr Phone: +49 (0) 2602 10673-0 Fax: +49 (0) 2602 10673-200 info@stakpure.de www.stakpure.de Leo Trumm Danny Schmidt Julius Albrecht Ansgar Knur Is reliable and economic preparation of pure and/or ultrapure water a topic for you? Just call us! We are certified according to ISO 9001: 2015 info@stakpure.de www.stakpure.de Retailer panel Subject to changes and printing errors. Effective 10.2017 www.filusch-fiore.de