SPEAKMAN SPEAKMAN SPECIFICATIONS

Similar documents
Installation, Operation and Maintenance Instructions

SSBF2150 Recessed Safety Station with Drain Pan, Exposed Shower Head

A. This Section includes the following emergency plumbing fixtures:

Product Bulletin Recessed Laboratory Units

Model 8356WCC Pull-Down Shower Eye/Face Wash

SPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Model Combination Shower Eye/Face Wash

Model 8356WCSM Pull-Down Shower Eye/Face Wash

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

EMERGENCY DRENCH SHOWER

Table of Contents ICON KEY. Quick ship icon indicates product is available for shipment within 48 hours for quantities of 4 pieces or less.

Installation S

CORALAIS BODYSPA BATH AND SHOWER FAUCET

PART # FOR PARTS SEE PAGE 4-2, 4-3

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Installation S

7000BT Eye/Face Washes

C. EWFs shall deliver the quality and quantity of water that is satisfactory for emergency washing purposes.

Model /8300CRP-8309CRP Shower & Eye/Face Wash

Installation S

Installation S

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

EMERGENCY EYEWASH AND SHOWER TECHNOLOGY

Installation S

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Model 7656WCC Eye/face Wash

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

TIMES SQUARE TWO-HANDLE THERMOSTAT

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Series 20 Dual Check Backflow Preventers

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

! WARNING. Before using product, read and understand instructions.

A B A B4

8200 Combination Units

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Model /8320CRP Shower and Eye/Face Wash

! WARNING. Before using product, read and understand instructions.

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Instructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle

General System Layout Sketch

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

INSTALLATION INSTRUCTIONS

TA-300, TA-300-LF, TA-350, TA-350-LF

Hoffman Specialty Watchman Series WC & WCS Condensate Units Replacement Parts PART LISTS DN0436C

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTALLATION INSTRUCTIONS

Product Specification

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Eyewash with. stainless steel bowl. (ts-sseyewash) Water. collection. bund. (ts-bund)

ROUGH IN VALVES. Installation Manual MB439 - SV9INC.219 EU MB440 - SV9INC.220 EU MB441 - SV9INC.221 EU MB442 - SV9INC.222 EU MB443 - SV9INC.

MOUNTING INSTRUCTIONS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Installation Instructions

MINIATURE THERMOSTATIC VALVE

Installation Instructions

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

INSTALLATION INSTRUCTIONS

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

Single-Control Lavatory Faucet

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

Installation S IMPORTANT! Bradley Thermostatic Mixing Valve for Individual Showers. Table of Contents

TABLE 1 Electrical Specifications

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

MARTIN Insertable Dust Collector

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

INSTALLATION INSTRUCTIONS

Installation Instructions

! WARNING. Before using product, read and understand instructions.

HR Powder Feed Hopper

A HEATER KIT With Diesel Engine Connection Fittings

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

TABLE 1 Electrical Specifications. Phase

INSTANT-FLOW C-MICRO WATER HEATER

Lavatory Faucet INSTALLATION INSTRUCTIONS P24490-CR, P24490-LV, P24491-CR, P24491-LV, P24492-CR, P24492-LV, P24700, P24705, P24706, P24736, P24800

INSTALLATION GUIDE. Yellow Jacket Misting System. For help, call BIG-FANS or visit

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Owner's Manual. (200 Gallon Lawn Service Skid Sprayer) Technical Specifications. Operation. General Information. Warranty/Parts/Service

INSTALLATION INSTRUCTIONS

568X, 587X, 588X Series

SENJU SPRINKLER CO., LTD.

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

Installation Manual PS-225 & PS-275

HL45, HL80 Thermostatic High-Low Valves

INSTALLATION INSTRUCTIONS

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

NEW PRODUCTS! 59911_Sayco.indd 1 6/15/11 1:13 PM

Installation, commissioning and servicing instructions

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

INSTANT-FLOW C-MICRO WATER HEATER

Fixtures Installation

Transcription:

SE-575-DP-237 & SE-575-DP-238 Installation, Operation, and Maintenance Instructions EYESAVER EYE/FACE WASH & SAFE-T-ZONE EMERGENCY SURFACE MOUNTED WALL SHOWER DESCRIPTION Barrier-Free wall mounted emergency eye/face wash with drain pan for draining water. Unit supplied with plastic spray heads, with individual flow restrictors. Unit activated by pulling handle down to open position, and is supplied with a cabinet flush with wall to keep corridors free from obstruction. Unit also supplied with wall mounted emergency shower as described below. SE-575-DP-237: Emergency deluge shower unit with wall activator. Shower is supplied with a 1" NPTF stay-open full flow ball valve that is activated by pull handle that is mounted on wall. Shower head designed to mount flush with ceiling. SE-575-DP-238: Emergency deluge shower unit with wall activator. Shower is supplied with a 1" NPTF stay-open full flow ball valve that is activated by pull handle that is mounted on wall. Shower head designed to drop down through ceiling. SPECIFICATIONS EYE/FACE WASH: SPRAY HEADS: (2) ABS PLASTIC NON-AERATED. VALVE: BRASS, CHROME-PLATED. ACTIVATOR HANDLE: BLACK, NYLON PLASTIC. INLET: ½" NPT FEMALE. DRAIN: 1-1/4" BRASS TUBE. CABINET & DRAIN PAN: 20 GAUGE (.036 THK.) 300 SERIES STAINLESS STEEL WITH SATIN FINISH. EMERGENCY SHOWER: SHOWER HEAD: 8" DIAMETER STAINLESS STEEL (SE-575-DP-238). 10" DIAMETER STAINLESS STEEL FLANGED (SE-575-DP-237). COVER PANEL: 20 GAUGE (.036 THK.) 300 SERIES STAINLESS STEEL. VALVE: 1" NPT FEMALE BRASS, CHROME-PLATED. FULL FLOW STAY-OPEN BALL VALVE. ACTIVATOR: STAINLESS STEEL LEVER WITH BLACK PLASTIC ROTATING HANDLE. PIPING: 1" IPS STEEL PIPE NIPPLE & UNIONS. INLET: 1" NPTF. FLOW CONTROL: 20 GPM. SHIPPING WEIGHT: 27 LB. (SE-575-DP-238). 28 LB. (SE-575-DP-237). EMERGENCY SIGN: 7-7/8" X 12" PLASTIC WALL SIGN.

InstAllAtion Review and understand configuration of the unit as shown in the diagrams following in this instruction before roughing in or installing unit. 1. Once desired location & spray head height is determined cut openings in the wall for the eye/face wash & emergency shower per the minimum dimensions shown in Fig. 1, making sure there are suitable structures (stud, etc.) on each side of the eye/face wash opening for securing the eye/face wash cabinet to the wall. 2. Making sure unit is level, use appropriate fasteners (4) to secure unit to wall as shown in Fig. 2A & Fig. 2B.

3. Plumb the eye/face wash & emergency shower ball valve (supplied) as shown in Fig. 2A & Fig. 2B, and the required water supply piping (supplied by others). For smooth activation, make sure that when final union connection is made that the stainless steel activation lever handle is as close to perpendicular to the finished wall as possible. Use thread sealant on all pipe thread connections (not union connections). The eye/face wash is supplied with a ½" NPT inlet, and requires a minimum 30 PSI flowing water pressure, and the emergency shower is supplied with a 1" NPT inlet. Shown in Fig. 1 as dotted lines is the recommended piping configuration for a single water supply inlet. NOTE: Water supply to the unit to be an uninterrupted source of potable water. Failure to use potable water can result in emergency units producing impure or contaminated water causing possible further injury. 4. Connect drain tailpiece or waste an adequate drain in compliance with local and/or national plumbing codes. 5. Assemble shower head to supply piping accordingly. Drop down design for the SE-575-DP-238, and ceiling mount for the SE-575-DP-237. Make note that ANSI specifies that showerhead must be 82"-96" from the surface on which the user stands. Use thread sealant on all pipe thread connections. See shower head differences in Fig. 3. 6. Once piping is complete, and all supply and drain connections are made. Assemble lever handle to valve making sure it is oriented correctly. Place the stainless steel wall panel into position and make sure the lever handle rotates from the on & off positions freely without dragging on wall panel. If valve operates correctly, secure the wall panel to the wall using proper fasteners. If dragging occurs, loosen 1" union and adjust 1" ball valve so the lever handle is centered in the wall panel slot, and any interference is eliminated.

7. Assemble the black nylon rotating handle, and 3/8-16" hex nut to the activation lever handle. 8. Turn water supply on and test the eye/face wash & shower. OPERATION The eye/face wash is activated by pulling the handle on the eye/face wash drain pan down to the open position. Once the eye/face wash is activated water will discharge from the spray heads until the unit is manually shut off. To shut off, lift back onto the upright off position. The shower is activated by pulling/pushing the handle in the downward direction to the full open position. Once the valve is activated the head will continue to discharge water until the valve is manually closed. The unit is shut off by pulling/pushing the handle in the upward direction to the complete off position. TESTING PROGRAM The American National Standards Institute (ANSI) states that all safety emergency equipment shall be activated on a weekly basis to flush the line and verify proper operation. Speakman Company furnishes a testing record tag (91-0635) with each unit. On this tag the date of inspection and the inspector s initials should be noted. MAINTENANCE Should you need to repair components behind the wall (valve, lever handle, etc.); the cover panel is removed by following these instructions. 1. Shut off water supply before doing any repair to this unit. 2. Position lever handle in the half-open (horizontal) position, and remove black plastic rotating handle from lever handle. 3. Remove the (4) fasteners that attach the cover panel to the wall, and slide the cover panel off. This will give you full access to valve and lever handle inside the wall. 4. Once repair is made follow above instructions in reverse to reassemble handle and panel cover. Be sure to turn water supply back on once repairs are final. WARNING: Use only genuine Speakman parts when repairing or replacing components. To order parts call 1-800-537-2107.

Rough-In MEASUREMENTS REPAIR/REPLACEMENT PARTS ITEM NUMBER PART NUMBER DESCRIPTION 1 RPG20-1985 1" Emergency Shower Ball Valve 2A 2B SE-830 SE-820 10" Stainless Steel Shower Head for SE-575-DP-237 (shown in Fig. 3) 8" Stainless Steel Shower Head for SE-575-DP-238 (shown in Fig. 3) 3 RPG20-2010-RCP Swing Down Eye/Face Wash Valve Assembly 4 RPG38-0417 Non-Aerated Spray Head Assembly NOT SHOWN RPG05-0673 Internal O-rings, Screws for Eye/Face Wash Valve

FLOW DATA EYE/FACE WASH: FLOW PRESSURE PSI (BAR) 30 (2.07) FLOW RATE GPM (LPM) 3.9 (15) SHOWER: FLOW PRESSURE PSI (BAR) 20 (1.38) 60 (4.14) FLOW RATE GPM (LPM) 20 (75) 25 (94) NOTE: This unit should be connected to an uninterrupted source of potable water, with a minimum flowing pressure of 30 PSI and a maximum static pressure of 80 PSI. Note: All units meet existing ANSI Z358.1 Standards and OSHA Rules. Product improvements may cause specification and dimensional changes without notice.