Feature Summary. I. System

Similar documents
Digital Precise Air Control - DPAC

VCB-X Modular Service Tool Technical Guide. VCB-X Controller Code: SS1051 Version 2.0 Requires Service Tool Code: SS1041 Version 2.

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Your Home. Jacco & Assoc.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

VCM-X Controller Technical Guide

Control Systems. Introduction & Overview. A New Way to Look at Building Controls Rev. B (0602)

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

VCM-X / RNE Operator Interfaces Technical Guide

VCCX2 Controller Operator Interface SD Technical Guide

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

SEQUENCE OF OPERATIONS

HVAC Controls Upgrades: Requirement Details ( )

York 25-Ton VAV Rooftop Unit

Your Home. Jacco & Assoc. Fan on with call for heating or cooling Heating on with call from space thermostat Stage as

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

Corrigo E. Second generation which contains all applications and languages

HVAC Controls Upgrades: Requirement Details ( )

L CONNECTION NETWORK Commercial Controls

Reference Guide for Microprocessor Controller

VCCX2 Controller Operator Interface SD Technical Guide

Reference Guide for Microprocessor Controller

1.0 Digital Controller

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

ACT2-CS Convenience Store Controller

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

Reference Guide for Microprocessor Controller

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

AIR HANDLING SYSTEM RETRO-COMMISSIONING TRENDING ANALYSIS

Product Data. Features/Benefits. 33CS Carrier Comfort System Variable Volume and Temperature (VVT )

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

VCM-X Modular E-BUS Controller Technical Guide

VCM-X / RNE Controller Operator Interface SD Technical Guide

1.0 Digital Controller

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

DX-9100 Applications from Engineering Services

RE: Phase 2 Improvements DATE: July 1, 2016 New Administration Building Wernle Youth & Family Treatment Center 2000 Wernle Road Richmond, Indiana

Cultivator & Hybrid Cultivator

Water Source Heat Pump Module Technical Guide

CAREL heatersteam Electric Element Steam Humidifiers

Job Name Control Systems Description Date

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

intelligent fire alarm ID60series panels

Heat Link. Technical Guide

SECTION SEQUENCE OF OPERATIONS FOR BUILDING CONTROLS

Tri-Stack Smart System

AirTrak. Digital Control System. User Manual. Touchscreen Systems

MicroTech Self-Contained Air Conditioning System

Zoning Solutions. Thermostats & Wiring Centers Designed to Maximize Indoor Comfort. A Watts Water Technologies Company

LG ELECTRONICS Air Conditioning Technologies LG Guide Specifications Controls

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

MicroTech Rooftop/RMC

CONTROLS MANUAL For all Innovent and Valent air handling products

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Intelligent Single Loop Fire Alarm Control Panel

OPTIMUM APPLIED SYSTEMS,

Siemens Thermostats. RDY2000BN Thermostat

I/O ZONE 560/583 USERS GUIDE

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Safety & Installation Instructions

AdaptAire. Digital Control System. User Manual

Document # R01

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

HEAT TROL ELITE SERIES HWE-Single Stage, HWE-MOV, HWE-Mulit Stage Hot Water Reset Control for Light Commercial and Residential Applications Provides q

Application Data Part Numbers: 33ZCVVTZC-01, 33ZCBC-01, 33ZCVAVTRM, 33ZCFANTRM

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Installation, Operation, and Troubleshooting Instructions

AireLogic. Digital Control System. User Manual

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

New Versa IC Platform

GB Art. Nr

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

CONTENTS. Installation Guide. VT7200 Series

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Bryant 2007 Family of Controls

Installation, Service, and Troubleshooting Instructions

An HVAC Audit of the Canberra Institute of Technology

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Controls Lite. Controls Instruction, Operation, and Maintenance. IOM-C Part Number

Specification for On-Line UPS Battery Monitoring and Data Management System

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Flexible & Innovative. Cooling Solutions

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

AdaptAire. Digital Control System. User Manual. Expert Systems

Verasys System Operation Overview Technical Bulletin

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

INSTRUCTION MANUAL P Heating and 1 Cooling

HVAC Mandatory Provisions Part II, Page 1

INTEGRATED AUTOMATION FACILITY CONTROLS

Building Automation Systems Standards

Transcription:

I. System A. Supports up to 60 VAV HVAC Units 1. Each HVAC Unit Can Support up to 59 VAV Boxes 2. Constant Volume Units Can Be Integrated With VAV Units 3. System Can Support Over 3000 Controllers B. Fill-in the Blank Programming C. Program and Monitor VAV Unit and Box Controllers Without a Personal Computer D. Remote Communications Options 1. Modem 2. Intranet 3. Internet E. Free PRISM Personal Computer Software! F. Intelligent Integration Between HVAC Unit and Boxes G. VAV Box Packages Available From WattMaster or Factory Mounting Available From Other VAV Box Suppliers H. Automatic Controller Search and Find I. Password Access Security J. Onsite and Remote Alarm Notification Capability K. Operator Interfaces 1. System Manager a) Features: (1) User Friendly Interface (2) Menu Driven Programming (3) Function Keys Simplifies Data Entry (4) Program and Monitor all Controllers Without a Personal Computer 2. Handheld Service Tool a) Features: (1) User Friendly Interface (2) Menu Driven Programming (3) Function Keys Simplify Data Entry (4) Program and Monitor all Controllers Without a Personal Computer (5) Special Override Features for Service Technicians L. All Devices 24VAC - Low Voltage M. Non-battery Memory Back-up WattMaster Controls Inc. Copyright 2004 Page 1 of 7

II. VAV/CAV Unit Controller A. Stand Alone Controller B. One Controller Supports Variable Air Volume and Constant Air Volume Applications C. Works With Heat Pumps D. Up to 16 Relay Outputs Configurable for: 1. Heating Stages 2. Cooling Stages 3. Exhaust Fans 4. Preheat for Low Ambient Protection 5. Gas Reheat for De-humidification on CAV Units 6. Warm-up Command for Non-WattMaster Boxes 7. Reversing Valve for Air to Air Heat Pumps 8. Alarm Indication E. Heating/Cooling 1. Staged Control a) Up to 8 Stages Cooling b) Up to 8 Stages Heating 2. Modulating Control With Expansion Module (Optional Feature Contact Factory) a) Chilled Water Valve b) Hot Water Valve or SCR F. Field Selectable Controlling Sensor: 1. Supply Air Temperature 2. Return Air Temperature 3. Space Temperature 4. Outdoor Air Temperature 5. Signal From Remote Source G. Supply Air Reset Sources: 1. Outside Air Temperature 2. Space Temperature 3. Fan VFD Percentage 4. Return Air Temperature 5. External Voltage Signal 6. Local Analog Value H. VFD Control 1. Supply Fan Static Pressure 2. Relief Fan WattMaster Controls Inc. Copyright 2004 Page 2 of 7

I. Economizer Control 1. Drybulb 2. Wetbulb 3. IAQ/CO2 Reset 4. Free Night Cooling J. Relief Fan 1. Controlled From Building Pressure Sensor 2. Variable Relief Control With VFD 3. On/Off Relief/Exhaust Fan Control K. Plug-in Expansion Boards for Added Capability L. Scheduling Functions 1. Time of Day Scheduling a) Occupied/Unoccupied - Night Set Back/Up b) 2 Events per Day 2. Holidays a) 365 Day Programming b) 14 Events per Year (1) Event = 1 Day or Group of Days 3. Automatic Daylight Savings Adjustment M. Fan Proof of Flow N. De-humidification Control With Hot Gas Reheat for Constant Volume Applications O. Morning Warm-up P. Outside Air Temperature Lockouts Q. Optimal Start R. Equipment Safeties 1. Fan Delay 2. Staging Delays 3. Minimum Off Time 4. Minimum Run Time S. Remote Overrides 1. Occupied/Unoccupied 2. Forced Cooling Mode 3. Forced Heating Mode WattMaster Controls Inc. Copyright 2004 Page 3 of 7

T. Alarms 1. Mechanical Failure a) Heating b) Cooling 2. Space Sensor Failure 3. Fan Failure 4. Dirty Filter 5. Controlling Temperature Alarm U. Controller Board Features 1. Status LEDs a) Power b) Relay Status c) Communications d) Diagnostics 2. Quick Disconnect Terminal Blocks 3. Plug-in Service Port 4. Plug-in Port for Expansion Boards 5. Field Replaceable Communication Driver Chip V. Trend Logging Values: 1. Date and Time 2. Space Temperature 3. Return Temperature 4. Active Heating and Cooling Setpoint 5. Supply Air Temperature 6. Outside Air Temperature 7. Outside Air RH (if installed) 8. Static Pressure 9. Economizer Percentage 10. Supply Fan VFD Percentage 11. Relief Fan VFD Percentage 12. Onboard Relay Status 13. Expansion Board Relay Status 14. Supply Setpoint Reset Value 15. Relief Pressure Reading 16. Adjustable Log Interval WattMaster Controls Inc. Copyright 2004 Page 4 of 7

III. VAV Box Controller A. Box Types 1.Cooling Only 2.With Reheat a) Electric (1) Staged (2) Modulating SCR b) Hot Water (1) Modulating (2) On/Off c) Reheat Interlock With Supply Fan 3. Fan Powered a) Series b) Parallel B. Direct or Reverse Actuator Control C. Airflow Control 1. Pressure Dependent or Independent 2. Min Position Settings for All Modes 3. Damper Force Modes D. Precision Proportional/Integral Damper Control Algorithm E. Alarms: 1. Hi and Low Space Temperature 2. Space Sensor Failure 3. Damper Actuator Failure 4. Airflow Sensor Failure 5. Damper Feedback Failure F. Trend Logging Values: 1. Date and Time 2. Space Temperature 3. Active Heating and Cooling Setpoint 4. Supply Air Temperature 5. Air Flow on Pressure Independent Boxes 6. Damper Position 7. Adjustable Log Interval WattMaster Controls Inc. Copyright 2004 Page 5 of 7

G. Controller Board Features: 1. Status LED's a) Power b) Relay Status c) Communications d) Diagnostics 2. Quick Disconnect Terminal Blocks 3. Plug-in Service Port 4. Plug-in Connectors for: a) Actuator b) Flow Sensor c) Expansion Board 5. Field Replaceable Communications Driver Chip IV. PRISM Software A. Windows Based 1. Compatible With 95, 98, ME, XP, 2000 B. User Friendly 1. Auto Installation 2. Fill-in the Blank/Point and Click Programming 3. Pre-designed Status Screens C. Communication with Controllers From a Personal Computer 1. Onsite 2. Remote a) Modem b) TCP/IP Internet D. Data Logging 1. Trend Logging a) Automatic Trend Log Retrieval via a Personal Computer 2. Alarms Logging 3. Tenant Override Logging 4. User Log In History WattMaster Controls Inc. Copyright 2004 Page 6 of 7

E. Alarm Reporting 1. Direct to Personal Computer 2. Via Modem to Remote Personal Computer 3. Via Modem to a Pager 4. Via E-mail With TCP/IP Connection F. User Defined Descriptors for All Controllers G. User Defined Custom Graphics H. Auto Device Search and Find Feature I. Multiple Password Levels J. Broadcast Programming Allows Multiple Controllers to be Programmed With Just a Click! K. Status Reporting Documentation V. Add-On Devices A. Lighting Controller 1. Indoor or Outdoor Lighting 2. Point and Click Programming 3. Personal Computer Required for Set-up B. General Purpose Controllers 1. Configurable Controller for Special Control Functions 2. Covers Broad Range of Possible Applications: a) Boilers b) Pumps c) Unit Heaters d) Exhaust Fans e) Time Clock Control f) Monitoring g) Logic Statement Programming Provides Flexibility for Special Requirements. C. Scheduler 1. For Expansion of Scheduling Capability 2. Expands Holiday Capacity WattMaster Controls Inc. Copyright 2004 Page 7 of 7