C1050ES Tankless Water Heater

Similar documents
C1210ES Tankless Water Heater

940ES Tankless Water Heater

940ES Tankless Water Heater

C1210ESC Tankless Water Heater

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

940ESO Tankless Water Heater

Commercial Tankless Rack System

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Commercial Tankless Rack System

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Residential/Commercial Gas Condensing Tankless Models

Tankless Condensing High Efficiency Water Heaters

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Commercial Tankless Rack System

Residential Gas Tankless Water Heater

Commercial Tankless Rack System

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Concentric Vent / Air Intake Kit Stainless Steel

Bosch Buderus SSB255/399/512 Stainless Steel Condensing Boiler

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

GB Condensing Gas Boiler

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

The WCGH High Efficiency Commercial Water Heater with Storage Tank

GB Condensing Gas Boiler

iq1001, Gen II Submittal Data

iq251, Gen II Submittal Data

10 : 1 Turndown Ratio

Crossover. Hybrid Water Heater HIGH EFFICIENCY. Advanced Heating & Hot Water Systems. w w w.htproducts.com

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

GB Condensing Gas Boiler

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

C 950 / 1050 ES C 950 / 1050 ES - Natural Gas / C 950 / 1050 ES - Liquefied Petroleum (LP) Gas

Suggested Specifications Prestige Excellence 110

Bosch Greentherm Series

C 1050 ES - Natural Gas C 1050 ES - Liquefied Petroleum (LP) Gas

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

C 1210 ES/ESC - Natural Gas C 1210 ES/ESC - Liquefied Petroleum (LP) Gas

Tankless Water Heaters

Date: Project #: Engineer: Prepared By: Bid Date:

RTG 199 HE INDOOR MODEL. RTG 199 HEN - Natural Gas RTG 199 HEX - Propane (LP Gas) Installation and Operation instructions

TL-Pro 175C/199C INDOOR MODEL. TL-Pro 175/199 C - Natural Gas TL-Pro 175/199 C- Propane (LP Gas) Installation and Operation instructions

Installation and Operation Instructions Manual

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Automatic Circulating Water Heaters

DIVISION FINNED WATER-TUBE BOILERS

Greentherm 9800 SE 160/199 SEC 199

DIVISION FINNED WATER-TUBE BOILERS

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

FINNED WATER-TUBE POOL HEATERS

Installation and Operation Instructions Manual

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

WATER-TUBE POOL HEATERS

On-Demand Water Heater Installation Manual and Owner s Guide

Commercial Gas Water Heaters

Commercial Gas Water Heaters

MECHANICAL VENTING VERSATILITY

FINNED WATER-TUBE POOL HEATERS

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Installation Manual CONDENSING TANKLESS GAS WATER HEATER DANGER WARNING CAUTION CAUTION

Residential & Commercial

advanced : technology

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

MODEL GWH 2400 ES NG and GWH 2400 ES LP - INDOOR MODEL

Commercial Applications

i200, Gen II i250, Gen II Submittal Data

C 1210 ES/ESC C 1210 ES/ESC - Natural Gas / C 1210 ES/ESC - Liquefied Petroleum (LP) Gas

HIGH OUTPUT. Skin design RANGE

TABLE OF CONTENTS BRADFORD WHITE BOILERS

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

MODEL GWH 2700 ES NG and GWH 2700 ES LP - INDOOR MODEL

Date: Bid Date: Model: i200 i200p. Project Name: Project #: Location: Fuel Type: Natural Gas Propane. Engineer: Contractor: Key Features.

DI/RO GAS TANKLESS WATER HEATER

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

iq751/iq1001/iq1501 Specifications (Floor-standing units)

Project Name: Location: Engineer: Contractor: I. GENERAL

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

CAUTION. Requests to Installers In order to use the water heater safely, read this installation manual carefully, and follow the installation

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Sun Bandit Hybrid Gas Water Heater Installation, Operation and Maintenance Manual

G515/7 Cast Iron Boiler

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Utica Boilers MAC Submittal

Transcription:

Engineering Submittal Sheet Dimensions and Connections B C D C Combustion air inlet Exhaust outlet Optional combustion air inlet Top view Top view A E F Hot water outlet Cold water inlet Inlet water filter H J C G Front view Side view I K Bottom view Gas supply connection Bottom view Condensate drain Dimensions Unit A B C D E F G H I J K Value Inches 30½ 17⅞ 5¼ 11¼ 2¾ 6⁵ ₁₆ 2⁵ ₁₆ 6½ 2¹ ₁₆ 4¹ ₁₆ 6¹⁰/₁₆ Engineering Specifications The system shall consist of Model Greentherm C 1050 ES NG/LP tankless water heaters as manufactured by Bosch Thermotechnology. Water Heater shall be CSA/ANSI Z21.10.3 listed. Water Heater shall have an input of 199,000 BTU/Hr with a gross output of 184,500 BTU/Hr when fired with natural gas. Water Heater shall operate with a minimum of 94% ANSI Z21.10.3 efficiency. Water Heater shall have a recovery of 285 gallons per hour at a 77 F temperature rise. Water Heater shall have Low NOx emissions and is 2012 SCAQMD NOx certified to rule 1146.2. CONSTRUCTION Water Heater shall be of gas fired, condensing tankless design with a modulating power burner and negative pressure gas valve. Burner shall be capable of 10:1 turndown of firing, without loss of combustion efficiency. Primary heat exchanger/ combustion chamber shall incorporate a multi pass copper tube and fin design with internal turbulators. Secondary condensing heat exchanger shall incorporate a multi-pass aluminum heat 1 of 6 reserves the right to make changes without notice due exchanger of fin tube design with copper water path to prevent galvanic corrosion. Heat exchangers shall be rated for working pressure not less than 150 psig. The Water Heater shall be equipped with a computer controlled active bypass valve that significantly improves water temperature stability. On the cold water inlet connection the Water Heater shall be equipped with an externally accessible in-line water filter. The Water Heater control panel shall be a single printed circuit board in water-resistant plastic enclosure. The entire Water Heater control panel shall be Underwriters Laboratories approved. The control panel shall contain: embedded control board incorporating LCD display to read temperature, and tactile buttons for output power, temperature, and programming control; CPU board houses all control functions; power

Engineering Specifications transformer; ignition spark module; and unique connections for each sensor or component. The control board shall be field replaceable. The combustion safeguard/flame monitoring system shall utilize spark ignition and a rectification type flame sensor. The control panel hardware shall support wireless remote communications if the wireless module is installed. The controls shall include extensive self-diagnostic capabilities that incorporate a minimum of 20 separate fault codes and 8 programmable system categories. The Water Heater shall come equipped with power cord and shall operate on 120V/1/60Hz electrical service. INSTALLATION All aspects of installation of Water Heater system shall be in strict accordance with manufacturer s instructions. Materials shall conform to all manufacturer s recommendations including a manufacturer listed vent system. Venting options shall include PP twin pipe venting, schedule 40 PVC and CPVC, a PP concentric up and out vent system, and a PP common venting system for up to 4 Water Heaters in either side by side or back to back arrangement. Water Heater system piping shall be field constructed of materials as specified. Water Heater shall be installed with individually isolating shutoff valves for service and maintenance, and a hot water hose connection for field testing. Water Heater shall have an ASME approved temperature/pressure relief valve with a setting of 150 psig. Water Heater shall require a minimum gas pressure of 3.5 W.C. (Natural Gas) at 1,000 scfh (full load rated capacity). MODE OF OPERATION Water Heater shall include integral factory wired operating controls to control all operation and energy input. Control of discharge water temperature shall be set through an internal setpoint with a field adjustment of 100 F to 140 F. A high temperature accessory shall be available that when installed allows the Water Heater to produce up to 184 F. Water Heater shall be capable of maintaining the outlet temperature within an accuracy of ±3 F. This shall be accomplished by modulation of firing rate from 100% to 10% of rated input. Water Heater shall operate with an Inverse Efficiency Curve, with maximum efficiency achieved at minimum firing input. MULTI UNIT CASCADES Up to 24 Water Heaters plumbed in parallel shall operate in a cascade configuration using the Cascading Kit. This accessory shall stage Water Heaters based on demand activating or deactivating other Water Heaters as needed. WARRANTY The heat exchangers shall carry a 15-year warranty against leakage due to defects in materials or workmanship or corrosion in a residential, non-direct recirculation system, subject to the manufacturer s warranty terms and conditions and water quality requirements. All other parts and components provided by Bosch shall carry a 5 year warranty against defects in materials or workmanship subject to the terms and conditions of the manufacturer s warranty. OR The heat exchangers shall carry a 5-year warranty against leakage due to defects in materials or workmanship or corrosion in a commercial installation, subject to the manufacturer s warranty terms and conditions and water quality requirements. All other parts and components provided by Bosch shall carry a 5 year warranty against defects in materials or workmanship subject to the terms and conditions of the manufacturer s warranty. Performance Data Unit Value Maximum gas input BTU 199,000 Minimum input BTU 19,900 Maximum output BTU 184,500 Minimum output BTU 18,300 Thermal efficiency % 94 Energy factor 0.94 2 of 6 reserves the right to make changes without notice due

Operational Data Unit Value C 1050 ES NG / Natural Gas - part number 7736501515 C 1050 ES LP / Liquid Propane - part number 7736501517 Weight lbs 74 Electrical voltage mains VAC / Hz 120 / 60 Power consumption max load A 2.5 Power consumption idle ma 40 Min. Inlet gas pressure NG / LP Inch W.C. 3.5 / 8 Max. Inlet gas pressure NG / LP Inch W.C. 10.5 / 13 Maximum Output Temperature F 140 Max. Working pressure psi 150 Min. Working pressure psi 30 Min. Activation rate GPM 0.5 Relief valve pressure rating psi 150 Venting category IV Approved vent or combustion air pipe material - United States Approved vent or combustion air pipe material - Canada PP concentric up and out venting, PVC sched. 40, PVC- DWV, CPVC sched. 40, ABS-DWV sched. 40, PP concentric common venting system for up to 4 units CSA or ULC certified only (ULCS636) Clearances W1 W5 W3 W1 W1 W2 W4 Top View Front View Description Unit Recommended Minimum clearance Side clearance W1 Inch 1 * 24 inches recommended for servicing. Front clearance W2* Inch 1 Top clearance W3 Inch 12 Floor clearance W4 Inch 12 Rear clearance W5 Inch 0 3 of 6 reserves the right to make changes without notice due

Required direct vent terminal clearances (twin pipe / concentric penetration) Clearance Data Item Description Value Canadian installations ¹ ) U.S. installations ² ) A Clearance above grade, veranda, porch, deck or balcony Inch 12 12 B Clearance to window or door that may be opened Inch 36 12 C Clearance to permanently closed window Inch * * D Vertical clearance to ventilated soffit located above the vent terminator within a horizontal distance of 2 feet (61cm) from the center line of the terminator Inch * * E Clearance to unventilated soffit Inch * * F Clearance to outside corner Inch * * G Clearance to inside corner Inch * * H Clearance to each side of center line extended above meter/ regulator assembly 36 in. within a height 15 feet above meter/ regulator assembly I Clearance to service regulator vent outlet Inch 36 * J Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other application Inch 36 * * K Clearance to mechanical air supply inlet Inch 72 36 in. above if within 10 feet horizontally L Clearance above paved sidewalk or paved driveway located on public property Inch 84 ³ ) * M Clearance under veranda, porch deck or balcony Inch 12 ⁴ ) * 1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code 3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. 4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. * For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2.20, or; b) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. 4 of 6 reserves the right to make changes without notice due

Required other than direct vent terminal clearances (single pipe penetration) 6720608836-23.1Av Clearance Data Item Description Value Canadian installations ¹ ) U.S. installations ² ) A Clearance above grade, veranda, porch, deck or balcony Inch 12 12 B Clearance to window or door that may be opened Inch 36 4 feet below or to side of opening; 1 foot above opening C Clearance to permanently closed window Inch * * D Vertical clearance to ventilated soffit located above the vent terminator within a horizontal distance of 2 feet (61cm) from the center line of the terminator Inch * * E Clearance to unventilated soffit Inch * * F Clearance to outside corner Inch * * G Clearance to inside corner Inch * * H Clearance to each side of center line extended above meter/ regulator assembly 36 in. within a height 15 feet above meter/ regulator assembly I Clearance to service regulator vent outlet Inch 36 * J Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other application Inch 36 * 4 feet below or to side of opening; 1 foot above opening K Clearance to mechanical air supply inlet Inch 72 36 in. above if within 10 feet horizontally L Clearance above paved sidewalk or paved driveway located on public property Inch 84 ³ ) 84 M Clearance under veranda, porch deck or balcony Inch 12 ⁴ ) * 1) In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code 2) In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code 3) A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. 4) Permitted only if veranda, porch, deck or balcony is fully open on a minimum of two sides beneath the floor. * For clearances not specified in ANSI Z223.1 / NFPA 54 or CSA-B149.1, one of the following shall be indicated: a) A minimum clearance value determined by testing in accordance with section 2.20, or; b) A reference to the following footnote: Clearance in accordance with local installation codes and the requirements of the gas supplier. 5 of 6 reserves the right to make changes without notice due

Water Heating Capacity Curve 13 12 11 10 Flow Rate (GPM) 9 8 7 6 5 4 3 2 1 0 10 20 30 40 50 60 70 80 90 Temperature rise ( F) 100 110 120 130 140 * 35 F capacity is based on installation with a mixing valve to overcome typical pressure loss through the water heater and system. Water Heating Capacity Data Temperature Rise F Flow Rate GPM 35 10.7 45 8.3 55 6.8 65 5.8 75 5.0 90 4.2 100 3.7 120 3.1 140 2.7 Tankless Components Components Legend 1 Exhaust temperature sensor 2 Condensing heat exchanger 3 Heat exchanger 4 Ionization sensor 5 Primary fan (Mixer) 6 Bypass valve 7 Hot water temperature sensor 8 LCD display 9 On/Off button 10 Reset button 11 Program button 12 Flue gas limiter 13 Heat exchanger overheat sensor (ECO) 14 Ignition electrodes 15 Observation window 16 Backflow temperature sensor 17 Secondary air fan 18 Gas valve 19 Condensate trap 20 Water valve with flow & cold water temperature sensors 21 Inlet water filter 22 Control unit 23 24 25 Up button Down button LED 6 of 6 reserves the right to make changes without notice due