Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment

Similar documents
Cooling Fans Contributing to Effective Use of Power

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

VIBRA-series: VIBRA, VIBRA +

Highly Efficient,Powerful Heating and Cooling.

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

"SAN ACE MC" for Pentium *

Project Number: P15441

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

A Novel Approach for the Thermal Management. of PC Power Supply

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

Your competent partner for measuring and services.

HUMIDITY IN INCUBATION

CASSETTE UNIT. Comfort Circle

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

LG VRF Systems. Air Conditioning Technologies

Bench Top Cooling Tower H893

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

MPU Cooler for Pentium 4, SAN ACE MC Michinori Watanabe Toshiki Ogawara Haruhisa Maruyama Masayuki Iijima

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

A660 Air Conditioning Laboratory Unit

portable gas analyser

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

What is the correct type of fan: Axial, radial, diagonal?

Ambient (ºF) Temperature Rise Above

Performance evaluation of an innovative fan-coil unit: Low-temperature differential variable air volume FCU

ASHRAE JOURNAL ON REHEAT

Air & Water Heat Pump R832

An Assessment of Radiator Performance

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

HPLC Column Ovens and Temperature Controllers

A novel test method for predicting crushing elasticity in medium fluting with higher relevance than for instance currently used methods like CMT

Comparative analysis of power supply single speed air mover and an entire electronics enclosure system fan

Automatic Isokinetic Sampler ST5

Secuflow laboratory fume cupboards

Tube-in-tube heat exchanger Type HE

ENSC 388: Engineering Thermodynamics and Heat Transfer

Secuflow laboratory fume cupboards

Compression of Fins pipe and simple Heat pipe Using CFD

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

Enclosure Temperature Control

EasyDry. Grain Drying Systems

Introduction to Fans. The Basics of Fan Principles and Terminology

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

"SAN ACE MC" for Pentium & Pentium 4

Compact Ultra Low Temperature Chamber

Energy-efficient heat source provides comfort in large rooms

INDUSTRIAL AIR CURTAIN. IndAC 2

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Primo Hotel. General. Indoor climate units for hotel rooms

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Electric Coils. Blower Coils. Product Information

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

High Performance Liquid Cooling System SAN ACE MC Liquid Tomoaki Ikeda Toshiki Ogawara Masashi Miyazawa Kouji Ueno

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

FROM COMPONENTS TO SYSTEM APPROACH OPTIMIZATION OF AIR-WATER HEAT PUMPS

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

ENVIRONMENT FRIENDLY CLIMATIC CHAMBER

DGC-500 DIGITAL GENSET CONTROLLER

AMCA Publication

Fans: Features and Analysis

Test Report No.: Page 2 of 14

NATIONAL INSTITUTES of HEALTH FUME HOOD TESTING PROTOCOL. For CONSTANT VOLUME FUME HOODS

Compact design for personal use Ready to network with your computer.

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Accurate. Reliable. Every Time. Air Measuring Instrumentation

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

Series SHR-5620 Digital Display Volumetric Meter Operation Instruction

Corn drying experiments by pilot dryer

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

DGC-1000 DIGITAL GENSET CONTROLLER

Unit 3 Machine Composition

Steam Injection Humidifiers for use with steam boilers PRODUCT CATALOG

Hot Food Holding Cabinets Test for FWE HLC

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Air flow management tutorial session. ACC Users Group 8 th Annual Conference Dallas, 4 October 2016 Sander Venema Howden Netherlands

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

CLIMATE SEPARATION SOLUTION. SensAir

I/A Series 716C 1/16 DIN Temperature Controller

Steam Injection. Humidification system

Transcription:

New Products Introduction Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment Katsumichi Ishihara Yo Muramatsu Takahisa Toda Masahiro Koike Hikaru Urushimoto 1. Introduction In recent years, devices have improved functionality and increased speed. Meanwhile, from an environmental perspective, there is great emphasis placed on low sound pressure level (SPL) and low power consumption. Under such circumstances, the thermal design of equipment is becoming increasingly important. An important element of thermal design is selecting the optimal fan. Generally, fans are selected through a process of estimation and simulation based on past results, then an evaluation on an actual machine. If the system impedance and operating airflow of a device could be more easily identified, the operating point of the fan specific to that device could then too be identified, so that the search for the optimal fan could be refined even further. In other words, it would be possible to select a fan which is optimal not only in terms of cooling performance, but also in terms of power consumption and SPL. Although ways to measure system impedance and airflow do already exist, it was difficult to use these to help with fan selection due to issues such as the measuring device being too large or the measuring accuracy being poor. For this reason, SANYO DENKI developed the San Ace Airflow Tester (hereinafter new product ) to easily and accurately measure the system impedance and operating airflow of a device. This paper will first introduce the features of this new product. Then, an example will be provided of how this new product can aid fan selection. 2. Outline of the New Product 2.1 External view and dimensional overview Figure 1 shows an external view of the new product, while Figure 2 provides an overview of its dimensions. Table 1 shows the specifications for the new product. (With connection duct attached) Fig. 1: External View of the San Ace Airflow Tester SANYO DENKI Technical Report No.42 November 216 18

Airflow direction 17 6 14 22 186 17 14 186 25 Fig. 2: Dimensions of the San Ace Airflow Tester Table 1: Specifications of the new product Item Measurement functions Airflow Measurement range Static pressure Airflow Measurement accuracy Static pressure Display/output data Main unit display Data output Interface Operating/storage Ambient temperature environment Humidity Input voltage Power supply Power consumption Dimensions Connection duct opening Mass Specifications System impedance, operating airflow, P-Q performance.2 to 8 m 3 /min (7 to 282 CFM) to 1, Pa ( to 4.1 inchh2o) 7% of the maximum airflow measured with each nozzle 1 Pa in relation to a measurement value of less than 2 Pa 5 Pa in relation to a measurement value of 2 Pa or more Airflow, static pressure (standard atmospheric pressure conversion: 2 C, 113 hpa) Airflow, static pressure (standard atmospheric pressure conversion: 2 C, 113 hpa), atmospheric pressure, ambient temperature, humidity RS-232C-USB serial converter to 4 C 2 to 85% RH (non-condensing) 1 to 24 VAC, 5/6 Hz 26 VA Max. 6 (W) x 25 (H) x 25 (D) mm 5 x 25 mm Main unit: Approx. 6 kg, connection duct: Approx. 1.5 kg 3. Product Features 3.1 Compact and lightweight The new product is compact and portable, measuring 6 mm (width) by 25 mm (height), by 25 mm (depth) and weighing 6 kg. Its lightweight structure is due to it being made primarily from injection molded plastic components. Moreover, the compact size is attributed to its integrated design, whereby the power source and control components are arranged on the top face of the main unit, while the sensors, etc. are on the side of the main unit. In addition, to increase further portability, it comes with a handle which can be stored away when the device is not being carried around. So for large equipment, it is possible to take measurements easily without moving from the location where the equipment is installed. 3.2 Measurement accuracy 3.2.1 Double chamber method The Airflow Tester uses the double chamber measurement 19 SANYO DENKI Technical Report No.42 November 216

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment method which is based on JIS and AMCA standards. When measuring highly turbulent air such as airflow from a fan, the double chamber method provides higher measurement accuracy than measurement using a pitot tube or calculating from wind velocity. As such, virtually all fan performance testers use the double chamber method. Figure 3 shows a model diagram for the San Ace Airflow Tester. Measured object Rectifying grid Ps Static pressure Chamber 1 Pn Nozzle Differential pressure Chamber 2 Auxiliary fan Rectifying grid Fig. 3: Model diagram of the Airflow Tester Chamber 1 and chamber 2 are separated by a nozzle, through which air passes. At this time, a pressure difference occurs between chamber 1 and chamber 2 (= differential pressure). Airflow can be calculated by measuring this differential pressure. Moreover, since the pressure difference (= static pressure) between the inside of the chamber and the atmospheric pressure can be measured at the same time, system impedance and operating airflow can be measured. An auxiliary fan is used to forcefully blow air into the object being measured, thus creating differential pressure and static pressure, and enabling system impedance to be measured. For operating airflow, the auxiliary fan controls the static pressure of chamber 1 so it becomes zero and airflow is calculated from the differential pressure at this time. Nozzle no. Fig. 4: External view of the nozzles Table 2: Nozzle specifications Internal diameter ø [mm] Airflow measuring range [m 3 /min] No. 1 18.2 to.42 No. 2 28.42 to.9 No. 3 42.9 to 1.9 No. 4 6 1.9 to 3.9 No. 5 82 3.9 to 8. Any of these five types of nozzles can be attached to the Airflow Tester to suit the airflow being measured. The new product features a guidance system to guide the user if he or she chooses a nozzle for an airflow outside of its measurement range, providing advice on which nozzle type to use to enable highly accurate measurement within the appropriate range. 3.3 Data Viewer Software The measured data can be confirmed on the operating panel on the top face of the main unit or as a graph on a computer when an RS-232C - USB serial convertor is used. Figure 5 shows a screenshot from the Data Viewer Software, specialized software used to convert measurement data into graph format. 3.2.2 Nozzle Using the double chamber method, airflow is calculated from the differential pressure generated by the nozzle. However, if airflow is low and the nozzle opening diameter is large, the differential pressure between chambers 1 and 2 will be too small, causing a greater airflow deviation. As such, SANYO DENKI designed five types of nozzles that can be used within the airflow measuring range of the Airflow Tester. The right nozzle to suit the airflow can be used to enable highly accurate measurement throughout the entire measuring range. Figure 4 shows external views of the nozzles while Table 2 gives their respective specifications. Fig. 5: Screenshot from the Data Viewer Software SANYO DENKI Technical Report No.42 November 216 2

Data on system impedance, operating airflow, and the fan s P-Q performance are shown in a layered format, and the airflow and static pressure values are displayed when the user selects an arbitrary point on the graph (for example where the graph intersects). For this reason, the operating point of the fan when it is installed in a device can be easily found. Moreover, a quadratic curve passing through the selected point can be drawn and its inclination (pressure loss coefficient) also automatically calculated. The information displayed on the graph can be saved in CSV format and also utilized with spreadsheet calculation software, etc. Moreover, if the saved CSV data is loaded, the same display as when the measurement was taken can be reproduced and displayed together with data measured afterwards. 4. Example of Fan Selection Using the Airflow Tester An approximation of system impedance can be obtained from the quadratic curve and expressed in the following formula from static pressure (Ps) and airflow (Q). Ps=C Q 2 Here, C is referred to as the pressure loss coefficient and it is a coefficient determined by load from the equipment, etc. If the pressure loss coefficient is large, so too is the system impedance, making it difficult for air to flow. On the other hand, air will flow easily if the pressure loss coefficient is small. Here, we will provide an example of selecting the optimal fan for a device by utilizing data measured on the Airflow Tester and this relational expression. 4.1 Fan selection by measuring the system impedance of a device This section will explain how to measure system impedance, then select the optimal fan from the measured values and airflow required to cool the device. First, measure the system impedance of the device and, as shown in Figure 6, draw an approximation of the quadratic curve. Next, identify the required operating point from the intersection with the formula-derived minimum airflow necessary to cool the device. Select fans which have P-Q curves that pass close to the top right of this operating point. Of the possible candidates, select the fan with the lowest SPL and power consumption at the operating point. In the case of Figure 6, since Fan A and Fan B meet the required operating point, they would create no problems insofar as cooling performance. However, of the two fans, Fan B has lower SPL (4 db(a)) and lower power consumption (4.2 W) at the operating point, so it can be said that Fan B is the best choice. In this way, the optimal fan for the device can be selected accurately and easily. 4.2 Fan selection by measuring the operating airflow of a device This section will explain how to select an even better fan by measuring operating airflow when a device is already equipped with a fan. First, use the Airflow Tester to measure the operating airflow of the device. Next, as Figure 7 shows, plot the P-Q performance curve of the mounted fan, then find the intersection of the measured operating airflow. This is the operating point of the current fan. Next, draw a quadratic curve (Ps=C Q 2 ) passing through this operating point to obtain the system impedance curve. Find the minimum airflow needed to cool the device through calculation or lowering the speed of the current fan. The point where the quadratic curve, Ps=C Q 2, and the necessary airflow intersects is the operating point. Select fans which pass closely to the top right of this operating point. Of the possible candidates, select the fan with the lowest SPL and power consumption. As Figure 7 shows, the currently installed Fan A actually has higher airflow than necessary to cool the device. By changing to Fan B, the cooling performance requirement can still be satisfied, but with an SPL reduced by 5 db(a) and power consumption reduced by 5.4 W; therefore, Fan B is the optimal fan for this device. In this way, the Airflow Tester significantly contributes to the optimal design of a equipment. 21 SANYO DENKI Technical Report No.42 November 216

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment 6 <Finding an operating point> 5 <Finding an operating point> 5 System impedance measured with the new product 4 Fan A (Performance at operating point = SPL: 58 db (A), Power consumption: 1.8 W) 4 3 2 1 Airflow necessary for cooling Required operating point 3 2 1 Required operating point Ps=C Q 2 Airflow necessary for cooling Operating airflow measured with the new product.2.4.6.8 1.2.4.6.8 1 6 <Fan selection> * SPL: Sound pressure level 5 <Fan selection> * SPL: Sound pressure level 5 Fan B (Performance at operating point = SPL: 54 db (A), Power consumption: 5.88 W) 4 Fan B (Performance at operating point = SPL: 53 db (A), Power consumption: 4.68 W) 4 3 2 Fan A (Performance at operating point = SPL: 58 db (A), Power consumption: 1.8 W) 3 2 1 1.2.4.6.8 1.2.4.6.8 1 Fig. 6: Optimal fan selection from the system impedance of a device Fig. 7: Fan selection from the operating airflow of a device SANYO DENKI Technical Report No.42 November 216 22

Development of the San Ace Airflow Tester - A Measuring Device for System Impedance and Operating Airflow of Equipment 5. Conclusion This paper introduced the features of the San Ace Airflow Tester developed by SANYO DENKI. This product enables the measurement of system impedance and operating airflow in order to select the optimal fan. The new product is the first in the industry* that is compact and portable, and enables easy measurement of system impedance and operating airflow. With the San Ace Airflow Tester, for the first time ever it is possible for our customers to clearly see the system impedance and operating airflow of a device during its development, greatly contributing to the optimum selection of fans and shortening development cycle times. We wish to continue engaging in product development from the viewpoint of our customers and offer products which match our customers needs. * Current as of Sept. 14, 216 in accordance with SANYO DENKI s investigation Katsumichi Ishihara Joined SANYO DENKI in 21. Yo Muramatsu Joined SANYO DENKI in 22. Takahisa Toda Joined SANYO DENKI in 1997. Masahiro Koike Joined SANYO DENKI in 26. Hikaru Urushimoto Joined SANYO DENKI in 214. 23 SANYO DENKI Technical Report No.42 November 216