Boltek EFM-INV-M / EFM-INV2 / EFM-INV3 Inverting Mounting Kit. Installation Instructions

Similar documents
SINGLE BURNER OUTDOOR PATIO STOVE/RANGE

How to Install a Mishimoto Radiator for a Mustang 5.0L

52 BERKSHIRE CEILING FAN

Fillmore Small Pendant Assembly and Installation Instructions

52 CEILING FAN. Owner s Manual Models #50336, 50337

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

BMW E36 Thermostat Removal And Coolant Flush

Ceiling Fan Installation Instructions

Ceiling Fan Installation Instructions

60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Owner s Manual FS-10/FreshSpa

STONE TROUGH CONSOLE SINK

OWNERS INSTRUCTION MANUAL

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Hanson LED C e i l i n g F a n

User s Manual and Operating Instructions

INSTALLATION MANUAL FOR MODELS: SOVANNA, BREZZA, TERRACINA, VENADO

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

Installation Instructions

Important Instructions

A B A B4

Installation Instructions

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Sunburst. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

kk21 installation Kk21-WF21 Things you might need for the installation: vessel sink,

CoolTouch TM control system

5CO52XX Series Fan UL Model No. : 5CO52. Owner s Guide and Installation Manual. Attach sales receipt to this card and retain as your proof of purchase

Owner s Guide and Installation Manual

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

CEILING FAN OWNER S MANUAL

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

52 DorsetTM. Instruction Manual. Basic Function Wall Control System Included. A Kichler Decor ceiling fan

Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Ceiling Fan Installation Instructions

Tripod Ceiling Fans. Installation Instructions Models: CT52, D52, FR52, ME52 & OL52 (800) BETTER BY DESIGN MEJOR DISEÑO BETTER BY DESIGN

Owner s Guide and Installation Manual

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Instructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.

INSTALLATION AND OPERATION MANUAL

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Installation Instructions

Installation Instructions

CEILING FAN OWNER S MANUAL

Parts & Material Included

Instructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Installation Instructions

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

SuperKlean Washdown Products

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

Engine Block Heater Service Kits (Tank Type) ROZJ 6076T and 6076A (John Deere Powered Standby Generator Sets)

WIDESPREAD KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE

TARVER SINGLE HOLE FAUCET INSTALLATION

2016 Ideal Vacuum (505) V 1.1

DATE OF PURCHASE: RETAILER NAME: MODEL NUMBER: RETAILER ADDRESS:

ASSEMBLY and INSTALLATION INSTRUCTIONS. Pipe wrench Ratchet 3/8 socket 9/16 socket 11/16 socket 3/16 Allen key 3/32 Allen key 9/64 Allen key

CELEBRITY DELUXE 52" indoor fans

Standard Installation Manual

The Arden Oscillating Floor Fan

Installation Instructions

Owner s Guide and Installation Manual

EDISON DUAL HANDLE VESSEL SINK FAUCET

A HEATER KIT With Diesel Engine Connection Fittings

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

CEILING FAN OWNER S MANUAL

Dimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

Align holes in retainer plate with the bolt holes on the legs. Start the threading the bolts only partially. You may need to pick up

PATTERSON FAN MANUAL. Operating, Installation & Parts Manual (OIPM) Patterson Fan Company, Inc Blythewood, SC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

Claw Feet & Pedestal Assembly

GRANITE COMPOSITE SINK

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

Ceiling Fan Installation Instructions

Instructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

5WF42XX Series Fan UL Model No. : AC-542OD. Owner s Guide and Installation Manual

Installation Instructions

Installation Instructions

Model No: 56DFH-L HS-1289-C. Cover for non-light option

Owner s Guide and Installation Manual

TOOLS REQUIRED: Crimping tool A/C Recovery Unit Wrench set up to 1 ¼ 4 Hole saw

52 SAN LUCAS CEILING FAN

5DI52XXD/5DI52XXD-L Series Fan UL Model No. : 5DI52. Owner s Guide and Installation Manual

INSTALLATION AND SERVICE MANUAL FOR THE TAC1000-P FAN SERIES (PNEUMATIC CONTROL) TAC1000-H FAN SERIES (HYDRAULIC CONTROL)

L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

Transcription:

Boltek EFM-INV-M / EFM-INV2 / EFM-INV3 Inverting Mounting Kit Installation Instructions Introduction The EFM-INV-M, EFM-INV2, and EFM-INV3 Inverted Mounting Kits will allow you to mount your EFM-100 or EFM- 200 Electric Field Mill in the inverted downward-facing configuration. Inverting your field mill will provide you with reduced precipitation noise. ELECTROCUTION WARNING: INSTALLATION THIS PRODUCT NEAR POWERLINES IS DANGEROUS. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. SEE ADDITIONAL WARNINGS ON REVERSE

ELECTROCUTION WARNING: INSTALLATION OF THIS PRODUCT NEAR POWERLINES IS DANGEROUS. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. FALL WARNING: DO NOT ATTEMPT INSTALLATION AT HEIGHTS UNLESS YOU ARE EXPERIENCED IN THE SAFE USE OF LADDERS AND FALL ARRESTING EQUIPMENT. IF UNSURE REFER INSTALLATION TO AN EXPERIENCED ANTENNA OR SATELLITE INSTALLER. LIGHTNING ACTIVITY WARNING: DO NOT WORK ON THE SYSTEM OR CONNECT OR DISCONNECT CABLES DURING PERIODS OF LIGHTNING ACTIVITY. Installation and Grounding Warning Warning Do not locate the sensor near overhead power lines or other electric light or power circuits, or where it can come into contact with such circuits. When installing the sensor, take extreme care not to come into contact with such circuits, as they may cause serious injury or death. For proper installation and grounding of the sensor, please refer to national and local codes (e.g. U.S.:NFPA 70, National Electrical Code, Article 810, in Canada: Canadian Electrical Code, Section 54). Document Revision History 1.0 2009 Original document 1.1 07/31/2011 Added instructions to apply silicone grease to threads and washer

Contents of the Kit Your EFM-INV-M (Pole mount bracket), EFM-INV2 (2 foot tripod) or EFM-INV3 (3 foot tripod) kit should include the following items: Inverting Mast Inverted Cover Shroud Junction Box Junction Box Cover Silicone Grease Pole mount bracket (EFM-INV-M) or 2' Tripod (EFM-INV2) or 3' Tripod (EFM-INV3) with clamps & bolts

Choosing a Mounting Location Choosing a suitable mounting location is the single most important aspect of a successful installation. KEEP CLEAR AREA Persons or animals entering the Keep Clear Area may be detected by the field mill as a High Electric Field or Lightning. If the field mill is mounted at ground level a fence or other barrier should be erected around the field mill. Keep the area directly under the field mill clear of long grass or weeds. Patio slabs or a poured concrete pad is recommended for ground installations. FIELD OF VIEW The electric field mill requires a view of the sky to detect the static charge on overhead clouds. Obstructions within the field mills field of view may reduce the sensitivity of the field mill Secure the tripod to the roof or patio slabs/concrete pad on the ground. For a no-holes tripod installation on a flat roof the tripod may be secured to patio slabs placed on the roof. Run cables away from the field mill sensor, not directly underneath.

Assembling the pole mount bracket (Skip this page if using INV2 or INV3 kit) Remove nuts and washers from the two U-Bolts and place around inverted mast. Secure bolts to bracket as shown below Open hose clamps, and hold bracket against pole. Place hose clamps through bracket and tighten around pole. Recommended pole size is between 2.5" and 4" outer diameter. If a larger pole is used, bigger hose clamps can be purchased at a local hardware store.

Assembling the hardware EXPLODED VIEW OF ASSEMBLY COAT THREADS AND RUBBER WASHER WITH SILICONE GREASE. RUBBER WASHER MUST BE LOCATED BETWEEN NUT AND SHROUD. FAILURE TO PROPERLY INSTALL WASHER WILL RESULT IN WATER DAMAGE TO FIELD MILL NOT COVERED BY WARRANTY

PIPE WRENCH TIGHTENING BULKHEAD ONTO MAST (HAND TIGHT +4 TURNS WITH WRENCH) COAT PIPE THREADS WITH SILICONE GREASE. FAILURE TO PROPERLY TIGHTEN BULKHEAD ONTO MAST WILL RESULT IN WATER DAMAGE TO FIELD MILL NOT COVERED BY WARRANTY READY FOR THE FIELD MILL TO BE CONNECTED REFER TO THE EFM-100/200 DOCUMENTATION FOR DETAILS ON CONNECTING AND GROUNDING YOUR FIELD MILL

EFM-INV2 USE 0.75X EFM-INV3 USE 0.5X INSTALL THE APPROPRIATE SENSITIVITY PLUG BEFORE CONNECTING FIELD MILL

COAT BOTH SIDES OF THE RUBBER WASHER WITH SILICONE GREASE Connect Power, Ground and Fiber Optic connectors, then screw the Field Mill to its cover. Lower the Shroud over the Field Mill. Lower the greased rubber washer onto Bulkhead Connector, and then the Bulkhead Nut. Tighten the Bulkhead Nut until the Rubber Washer is visibly compressed. PIPE WRENCH TIGHTENING NUT ONTO RUBBER WASHER (NOTE: LEFT-HANDED COUNTER-CLOCKWISE THREAD ON NUT )

DO NOT ALLOW FIELD MILL TO ROTATE OR WIRES CONNECTING FIELD MILL WILL TWIST COAT BOTH SIDES OF RUBBER WASHER WITH SILICONE GREASE. FAILURE TO PROPERLY TIGHTEN NUT ONTO RUBBER WASHER AND SHROUD WILL RESULT IN WATER DAMAGE TO FIELD MILL NOT COVERED BY WARRANTY COMPLETED ASSEMBLY (with 2' tripod) COMPLETED ASSEMBLY (with pole mount bracket)