Dräger REGARD -1 Control System

Similar documents
Dräger REGARD -1 Control System

Dräger REGARD -1 Control System

Dräger REGARD 3900 Series Control System

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger QuadGard Control System

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Flame 5000 Flame Detection

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger Polytron 5720 IR Toxic Gas Detection

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger PIR 7000 Flammable Gas Detection

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Flame 2100 (UV) Flame Detection

Dräger X-am 2500 Multi-Gas Detector

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Flame 2100 Flame Detection

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Flame 5000 Flame Detection

Dräger X-am 5000 Multi-Gas Detector

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger Flame 2500 Flame Detection

The SharpEye 40/40I (IR3) Flame Detection

Dräger Pac 3500 Single-Gas Detection Device

Dräger PEX 3000 Flammable Gas Detection

Dräger Polytron 7000 Fixed gas detector

Dräger X-zone 5500 Area Monitoring

Dräger Polytron 8000 Stationary gas detector (EC)

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger X-am 5000 Multi-Gas Detection

Dräger Pulsar 7000 Series Detection of flammable gases and vapours

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

GS01 (wireless) Detection of flammable gases and vapours

Dräger Pac 6000 Single-Gas Detector

The SharpEye 40/40I (IR3) Flame Detection

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Pac 3500 Single-Gas Detection Device

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Pac 8500 Single-Gas Detector

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Containerized Live Fire Training System (CLFTS)

Dräger Pac 5500 Single-Gas Detection Device

Dräger X-am 2500 Multi-Gas Detection

The SharpEye 40/40M (Multi IR) Flame Detection

Dräger X-zone 5500 Area Monitoring

Dräger X-am 5000 Multi-Gas Detection

Dräger VVP 1000 System Components

Dräger Pac 6000 Single-Gas Detection Device

Dräger UCF 7000 Thermal Imaging Camera

Dräger Pac 8500 Single-Gas Detection Device

Dräger Pac 8000 Single-Gas Detection Device

Dräger Pac 7000 Single-Gas Detection Device

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

Dräger X-am 7000 Multi-Gas Detection

Dräger X-zone 5500 Multi-Gas Detection Device

On-site & Shutdown Safety Service CSE Monitoring

The SharpEye 40/40R (IR) Flame Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Bump Test Station Calibration and Bump Testing

Dräger Bodyguard 1000 Warning Device

Oxylog VE300 Emergency & Transport Ventilation

Dräger AFS 3000 Aircraft Fire Simulator

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Dräger X-pid 9000 / 9500 Multi-Gas Detection

ST More than the sum of their components GAS DETECTION SYSTEMS

Dräger Configuration and Evaluation Software

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Exterior Live Fire Training System (ELFTS-C), the CAR

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Training Authorised Gas Tester Level 1. Basic Information

Dräger X-am 7000 Multi-Gas Detection

Two-Channel Gas Controller

Exterior Live Fire Training System (ELFTS) the QUAD

Dräger FRT 1000 / ETR 1000 Location Devices

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Multi-Gas-Controller MGC2

Transcription:

Dräger REGARD -1 Control System The Dräger REGARD -1 is a standalone, self contained single channel control system for the detection of Toxic, Oxygen and Ex hazards. The control system is fully configurable for a single input from either a 4 to 20 ma transmitter or a Dräger Polytron SE Ex measuring head.

02 Dräger REGARD -1 Benefits High flexibility The Regard-1 can either be connected to a 4-20-mA transmitter or to Polytron-SE-Ex mv sensing heads. There are three fully configurable alarm relays: rising or falling, latching or non-latching. The alarm status is displayed via three LEDs. They will flash with a new alarm, light up continuously to display an acknowledged alarm situation or extinguish if there is no alarm. The gas concentration is displayed continually on a large LC display. If the alarm thresholds are exceeded or if a fault occurs, the integrated audible alarm will sound. To indicate a transmitter or system fault, a fault relay is provided, a separate fault led is provided on the panel which will flash under new fault condition, light continuously under acknowledged fault condition or will be extinguished under normal or healthy conditions. During maintenance, the maintenance or inhibit relay can be used to report this special status via a remote display. Useful additions The Regard-1 can be equipped with an optional TWA control module. This module enables the output of a TWA alarm as well as the repeat of a 4 to 20mA signal and the alarm states via a digital interface. To ensure the operation of the Regard-1 during a power failure, two batteries of 1.2 Ah each can be inserted into the integrated battery compartment. Depending on the transmitter used, they will enable an operating time from 30 minutes up to two hours. The batteries are re-charged by the Regard-1. Robust enclosure The robust IP65 enclosure enables the installation of the control system at virtually any location within safe areas. Certifications In accordance with the ATEX directive, the system is certified to EN 61779-1/4/5 and EN 50104 for explosion monitoring and oxygen measuring and, therefore, also suitable for applications which require the measuring function for explosion protection (primary measure in accordance with EN 1127-1, paragraph 6). In addition, the system was also tested independently to EN 45544 for the monitoring of toxic gases.

Dräger REGARD -1 03 System Components Dräger PIR 7000 ST-11659-2007 The Dräger PIR 7000 is an explosion proof point infrared gas detector for continuous monitoring of flammable gases and vapours. With its stainless steel SS 316L enclosure and drift-free optics this detector is built for the harshest industrial environments, e.g. offshore installations. Dräger PEX 3000 D-11158-2011 The transmitter Dräger PEX 3000 detects flammable gases and vapours in concentrations below their lower explosive limit. Its DD-sensor provides a long-term stable measuring signal and responds to gas within a few seconds. Dräger Flame 5000 D-49077-2012 The Dräger Flame 5000 is an imaging based explosion proof flame detector. This visual flame detection system uses digital image processing and advanced algorithms to process and interpret flame characteristics. This principle offers an extended field of view and fewer false alarms. Each detector is equipped with a colour CCTV camera. Dräger Polytron Pulsar 2 D-85830-2013 The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard Dräger Pulsar, Pulsar 2 is fitted with an ABS moulded cover and is supplied with either a junction box or certified connector to provide complete flexibility during installation.

04 Dräger REGARD -1 System Components Dräger Polytron 7000 ST-3812-2003 The Dräger Polytron 7000 is a gas detector that can satisfy many toxic and oxygen gas measurement applications on a single platform. It meets the requirements of the compliance market as well as the high specification requirements of customised solutions. Dräger Polytron 3000 ST-3811-2003 The Dräger Polytron 3000 is an intrinsically safe gas detector for the continuous monitoring of more than 60 toxic gases and oxygen in ambient air. It is the part of a new generation of gas detectors developed on a modular platform. Communication to the central control system is done via a 4 to 20 ma signal. Related Products Dräger REGARD 7000 D-6806-2016 The Dräger REGARD 7000 is a modular and therefore highly expandable analysis system for monitoring various gases and vapours. Suitable for gas warning systems with various levels of complexity and numbers of transmitters, the Dräger REGARD 7000 also features exceptional reliability and efficiency. An additional benefit is the backward compatibility with the REGARD.

Dräger REGARD -1 05 Related Products Dräger REGARD 3900 D-27777-2009 The Dräger REGARD 3900 is a standalone, self contained control system for the detection of Toxic, Oxygen and Ex hazards. The control system is fully configurable between 1 and 16 channels, depending upon the type and quantity of input/output boards installed.

06 Dräger REGARD -1 Technical Data Single channel controller, housed in a rugged ABS enclosure for in- and outdoor applications Power supply 110/240 VAC, 50/60 Hz Input 2/3-wire 4 to 20 ma transmitter or Dräger Polytron SE Ex measuring head Output 3 gas alarm relays, fault relay, inhibit relay Remote acknowledgement 4 to 20 ma (optional), RS 232 (optional) Operation One-button operation Large LC-display, status LED s Built-in buzzer Battery buffer 2 x 12 VDC, 1.2 Ah (optional) Ingress protection IP 65, NEMA 4 Dimensions 270 x 270 x 90 mm; 10.7" x 10.7" x 3.6" (H x W x D) Weight 2.5 kg; 5.5 lbs. Wiring 0.5 to 2.5 mm2; AWG 20 to 14 Ambient conditions Temperature 0 to 55 C; 32 to 130 F Pressure 700 to 1300 hpa; 20.7 to 38.4 inch Hg Humidity 0 to 100 % RH, non-condensing CE Electromagnetic compatibility (directive 89/336/EEC) Approvals Low voltage directive (directive 73/23/ EEC) ATEX II (2) G Dräger REGARD-1 4 to 20 ma 42 08 585 Dräger REGARD-1 SE Ex 42 08 600 Ordering Information Rechargeable battery kit Options board Display board with datalogger 42 08 586 (4 to 20 ma repeater, RS 232, TWA alarm relays) 42 08 583 42 08 636

Dräger REGARD -1 07 Notes

Notes Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Locate your Regional Sales Representative at: www.draeger.com/contact 90 44 703 15-04-2 Marketing Communications PP LE Printed in Germany Chlorine-free environmentally compatible Subject to modifications 2015 Drägerwerk AG & Co. KGaA 08 Dräger REGARD -1