"Pegaso" wireless alarm system

Similar documents
"Pegaso" wireless alarm system D.I.Y. wireless kit


Hardwire & Wireless Control Panels With Incorporated Automatic Telephone Diallers

PROGRAMMING PROCEDURES (Table 3)

Wireless Keypads LKP(E)S8M Series

Wireless Keypad GKP-S8M

Condominium Security Management System

Total Connect Box. User manual

Premium 8 Zone Wireless Alarm Kit

Sentry 4 Zone Alarm Panel User Manual

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Contents. Glossary

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

EVO192 v3.0 Fire and Burglary What s New

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

IDS816 User Manual H Issued January 2009

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

CONTENTS. (User s Manual)

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

User s Information Guide R2A

Watchguard WGAP864 User Manual

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Solution 844 Operators Manual ISSUE 1.10

L900 series USER MANUAL

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Destiny Destiny Owners Manual

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

CE818. User Manual. Made in Italy M1.5.1-H2.0-F1.41-S1.41-ENG

HILLS Series LED Code Pad User Manual

Protégé Eclipse LED Keypad User Manual PRT-KLES

Solution Ultima 862 Operators Manual ISSUE 1.10

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

LS800S Intruder Alarm System. Engineering Manual

Supervised Security System Owner's Guide

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Model 17A00 Expansion Enclosure

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

DESTINY OWNER S MANUAL

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Ref.1067/032 Ref.1067/042

E400 Wirefree. Alarm System. Installation & Operating Manual

DOMUS 5000 INSTALLATION MANUAL

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

User Manual. Alarm system: PhoneWatch TC

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Total Protection Alarm System

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

Digiplex LED Keypads User s Manual

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

3 User s settings. 3.3 Internal clock setting

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

For silent arm / disarm use BUTTON 2.

Control/Communicator Installation Manual

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

All-In-One Wireless Security System V1.0. Model #: MG-6060

5000 SERIES 8 ZONE INSTRUCTION MANUAL

Intruder alarm panel Terxon MX Operating instructions

NetworX NX-8V2. LED Keypad User Manual

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

NetworX Series NX-1500E LED Keypad

All-In-One Wireless Security System V1.0. Model #: MG Reference and Installation Manual

JA-63 Profi User manual

Auto Dialer. Manual E-921APQ E-921GPQ

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Movement Detector GJD 300

BURGLAR ALARM PANEL BS-468

Alarm Bell/Control Panel DOGE CT3

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

GSM LCD Touch Keypad Wireless Intelligent Alarm System. User s manual

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

AXI LED USER MANUAL (REV. 1.0)

ITI Caretaker Basic Commands

NESS 5000 SERIES DIALLER

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

status AW1 Plus WiFi Alarm System User Manual

CONFIGURATION OF THE OPTICALS

MOBILE CALL GSM Alarm System User s Manual

KwêBeams Effective wire free outdoor early warning system

MotorCycle Alarm by. Testing during the initial immunity phase Reversed flashing 1 BEEP

MetaSystem Homealarm. C300 System

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM WS-500X CONTENTS REV: 0.2 ERP P/N: ERP 机型 :SS21W2R-AU-EDP09940A-V1

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Transcription:

"Pegaso" wireless alarm system Summary Page 1.0. Description... 2 2.0. Installation... 3 3.0. Connections to mains power... 4 4.0. Low battery signalling... 4 5.0. Service key... 5 6.0. Selection of functions... 6 7.0. Programming... 7 7.1. Programming incorporated pyroelectric, NC line, wireless sensors and transmitters... 10 7.2. Cancellation of incorporated pyroelectric and NC line... 11 7.3. Cancellation of sensors and transmitters... 7.4. Cancellation of a group of sensor with the same configuration or of all keychain transmitters... 13 7.5. Cancellation total memory... 13 7.6. Programming of TLM-18VRP wireless siren... 14 7.7. Programming of TLM-21VRP wireless siren... 15 8.0. Zone description... 16 9.0. Arming of system... 17 9.1. Full arming (DAY mode)... 17 9.2. Partial arming (NIGHT mode)... 17 9.3. Disarming... 17 10.0. Test for NC line and wireless sensors... 18 11.0. Functioning... 19.0. Alarm cycle counter... 20 13.0. Hold-up alarm... 20 13.1. Hold-up alarm reset... 20 14.0. Alarm memory... 21 14.1. Alarm memory reset... 21 15.0. Connections... 22 16.0. Technical characteristics... 23 Notes... 24 Pag. 1

Congratulations on your purchase of the Telelink VP-7N, an advanced wireless alarm system. The Telelink VP-7N has been designed for fast and simple installation. The unit has been built using the most advanced microprocessor technology and production methods. Being tested by means of special computerized test jig, the Telelink VP-7N offers security and durability in time. 1.0. DESCRIPTI The Telelink VP-7N is a compact, self protected wireless security system, ideal for protection of homes, shops, offices, boats, campers etc. against; burglaries, fires, gas leaks, hold-up and medical distress. Characteristics: The Telelink VP-7N is a wireless self-learning system called PEGASO, capable of learning up to 4 billion different codes. Each wireless sensor is factory programmed and has its own code and will be linked with the desired VP-7N by means of the PEGASO self-learning system Total or partial arming (DAY or NIGHT) Infrared sensor and siren incorporated Optical signals for all functions. Other characteristics: Microprocessor controlled 40 wireless zones for sensor and sirens. Each zone can be programmed as burglary, fire or gas, immediate, delayed, Day or Night 1 zone for incorporated infrared sensor 1 zone for NC line Self learning of a maximum codes between keychain transmitters PEG-3 and keypads DIGIT-7VRP Alarm memory Two tone siren output for fire alarm Silent or audible hold-up alarm or medical distress alarm (selectable) Acoustic or silent arming/disarming signal (selectable) Alarm time programmable (2 or 4 minutes) Alarm cycle counter (excludable) Optical RF Test Output for arm and disarm signalling Auxiliary power output for hardwire sensors Free alarm relay contacts The Telelink VP-7N is a stand alone alarm system. It can be expanded at any time by installing the vast range of wireless devices listed below: AVAILABLE WIRELESS PERIPHERAL DEVICES IR-32VRP - Passive infrared sensor DTR-28VRP - Double technology sensor MG-1P / 6P - Magnetic contacts MG-3P - Transmitter for wireless operation of any type of detector with NC contacts SM-2P - Smoke detector GA-/15VRP - Gas detector WD-03 - Water detector TC-01 / 01B - Digital temperature sensor TLM-18VRP - Indoor siren with battery back-up TLM-21VRP - Outdoor siren with battery back-up Accessories: RX-2C DIGIT-7VRP - Remote Two channel digital receiver keypad with self-learning of 20 "Pegaso" codes RPS-1 PEG-3 - Repeater Three coded to increase channel the keychain range transmitter of wireless sirens RPS-20 RX-2C - Repeater Two channel to increase receiver the with range self-learning of wireless sensors of 20 "Pegaso" and keychain codes transmitters STC-01 RPS-1 - Peripheral Repeater to device increase to visualize the range the of system wireless status sirens RPS-20 - Repeater to increase the range of wireless sensors and keychain transmitters STC-01 - Peripheral device to visualize the system status Pag. 2

2.0. INSTALLATI To obtain the maximum performance from the Telelink VP-7N, the following procedure must be followed: Mount the Telelink VP-7N control panel centrally located between the various sensors (see Fig. 1). If the security system is to protect premises on various floors, install the control panel at one third of the height of the building (for example in a building of three floors, the panel must be installed on the first floor). Position the Telelink VP-7N at a height of 2 / 2.2 meters and oriented so transit crosses the sensor and is not oncoming (see Fig. 2). In the case that the Telelink VP-7N is positioned above 2.2 mt. from the floor, to guarantee the same coverage, tilt the unit as shown in the figure on the right. In order to avoid false alarm, do not install the Telelink VP-7N in the positions indicated in Fig. 3. Do not install cables within a 1.5 meter radius of the Telelink VP-7N. The power supply cable must be directed downwards from the unit. Avoid to install the control panel in the proximity of inductive loads (electric motors or similar), on metal surfaces, adjacent to elevators. C D C D D D F E E A D D D E C D D A Telelink VP-7N B TLM-21VRP (wireless siren) C IR-32VRP (wireless PIR detector) D MG-1P (wireless magnetic contact) E SM-2P (wireless smoke detector) F GA-/15VRP (wireless gas detector) All installation screws and wall plugs are included in the kit. D D B D C Fig. 1 To mount the Telelink VP-7N: Using the paper template provided, fix the two screws on to the wall. Adjust the distance between the head of the screw and the wall using the spacer tool provided (see Fig. 4). Align the screws with the holes on the rear of the Telelink VP-7N and insert the unit. Press the unit downwards until the Telelink VP-7N snaps into position. 2.2 mt NO Spacer 2 mt mt NO NO NO NO NO Wall Screw VP-7N 10 mt Fig. 2 Fig. 3 Fig. 4 Pag. 3

3.0. CNECTI TO MAINS POWER Power to recharge and maintain the units internal battery is secured by the AC power adaptor. During installation, insert the plug on the right hand side of the unit (as indicated in Fig. 5), then plug the power adaptor into the nearest mains outlet. Once the unit is powered up, the green power LED will light indicating mains presence (see Fig. 5). The red LEDs marked DAY ZE and NIGHT ZE are not active with the main power supply cut. They can however be made active upon request. Fig. 5 POWER ATTENTI Before plugging the AC adaptor into the mains outlet, make sure that the voltage rating marked on the power adaptor is the same as that of the outlet. Electrical building installation must be equipped with a bipolar automatic switch with current of 1A. The sectioning device of the power line is the plug: in case of ordinary maintenance, first unplug the device from the outlet. If the power adaptor is removed from the mains outlet for a period longer than 3 days, it is necessary that the Telelink VP-7N be powered down (key in OFF position - see paragraph 5.0.). Draining the units internal battery completely may cause permanent damage to the battery. 4.0. LOW BATTERY SIGNALLING In the absence of mains power the unit s internal battery will power the Telelik VP-7N for approximately 5 days (LEDs OFF). The normal battery operating voltage is V - 700 mah. Should the battery voltage fall below 10.5 V, then this condition will be signalled by the lighting of the LOW BATTERY LED (see diagram on the right). If this condition occurs the battery must be charged for at least 24 hours. LOW BATTERY If after having charged the battery, the LOW BATTERY LED remains lit, then the power adaptor or the battery are faulty and must be replaced. ATTENTI In respect of the environment, batteries should not be discharged of with the normal waste, but must be discharged of in the appropriate bins used for such gatherings, otherwise should be brought to specialized centers. Pag. 4

5.0. SERVICE KEY The key switch on the left hand side of the Telelink VP-7N (see figure on the right) is used as an / OFF device for the apparatus and must be used only as a service or emergency device. T h e servi ce key d o es no t arm o r d i sarm the un it. Turning the key clockwise ( position), all the functions are activated. Turning the key counter clockwise (OFF position), all functions are deactivated, but the recharge of the incorporated battery is guaranteed. OFF ATTENTI Every time the Telelink VP-7N is turned, the system automatically switches itself directly into OFF status (disarmed), whichever be the status it was in (armed/disarmed) when last turned OFF. This is signaled with the emission of 2 beeps. The service key should be kept in a safe place and used only in case of necessity (programming mode, maintenance etc.). Pag. 5

6.0. SELECTI OF FUNCTIS The functions listed on the below table, can be selected by using dips 1, 2, 3, 4 and 5. These can be found by removing the sliding cover situated above the service key (see the design on the right) Sliding cover If selection was made after installation, you must turn the key to the OFF position and remove the Telelink VP-7N from the wall. ATTENTI The selection must be made with the key in the OFF position. Dip Function Dip Position 1 Hold-up alarm 2 Alarm time 3 Arming/disarming beep 4 Alarm cycle counter 5 Alarm memory = Audible hold-up alarm OFF = Silent hold-up alarm = 4 minutes OFF = 2 minutes = Beep activated OFF = Beep deactivated = Counter activated OFF = Counter deactivated = Audible (beeps) and visible (flashing of "DAY ZE" and "NIGHT ZE" LEDs) alarm memory. OFF = Only visible alarm memory (flashing of "DAY ZE" and "NIGHT ZE" LEDs). Beeps will not be emitted. Pag. 6

7.0. PROGRAMMING While programming, the following operations can be made: Programming of the incorporated pyroelectric sensor and NC line Programming of the sensors (burglary, fire/gas) and sirens up to a maximum of 40 Programming of the keychain transmitters up to a maximum of Cancellation of the incorporated pyroelectric sensor, of the NC line, of one or more of the sensors or keychain transmitters Cancellation of a group of sensor (with the same configuration) or of all keychain transmitters Total cancellation of memory Note: Programming must be done with the wall tamper button open. The tamper button can be found on the back side of the unit. To program after installation, the service key must be turned to the OFF position. Back view Tamper button Programming is done by using dip switches 6, 7, 8, 9, 10, 11 e which can be found by removing the sliding cover situated above the service key (see diagram on the right). Sliding cover The following table illustrates the functions regarding all dip switches. Dip SUMMARY DIP-SWITCH TABLE Function 1 Selection of silent or audible hold-up function (see table on Page 6) 2 Alarm time selection (see table on Page 6) 3 Selection of change of state beep (see table on Page 6) 4 Selection of alarm cycle counter (see table on Page 6) 5 Alarm memory (see table on Page 6) 6-7-8-9 Programming of incorporated pyroelectric sensor, NC line, wireless sensors (immediate, delayed, Day, Night) and keychain transmitters (see Tables 1 and 2 on Page 8) 10-11 Selection of operations (see table 1 on Page 8) Access / Exit of programming mode Pag. 7

TABLE 1 Type of operations to be done Dip 10 Dip 11 Programming of the incorporated pyroelectric sensor, of the NC line, of the wireless sensors (burglary, fire/gas), of the keychain transmitters and of sirens tamper (see paragraphs 7.1. / 7.6. / 7.7.) Cancellation of the incorporated pyroelectric sensor, of the NC line, of the wireless sensors (burglary, fire/gas) and of the keychain transmitters (see paragraph 7.2 / 7.3) Cancellation of a group of sensor (burglary, fire/gas) with the same configuration or of all keychain transmitters (see paragraph 7.4.) Cancellation total of all the sensors, sirens, NC lines, incorporated pyroelectric sensor and keychain transmitters ( total cancellation of the memory) (see paragraph 7.5.) OFF OFF OFF OFF TABLE 2 Category Protection Immediate Delayed Day-Night Dip 6 Dip 7 Dip 8 Dip 9 Incorporated pyroelectric sensor Burglary Immediate Day OFF OFF OFF Delayed Day OFF OFF Immediate Night OFF OFF Delayed Night OFF NC Line Burglary Immediate Day OFF OFF OFF Delayed Day OFF OFF Immediate Night OFF OFF Delayed Night OFF Wireless sensor Burglary Immediate Day OFF OFF OFF OFF Delayed Day OFF OFF OFF Immediate Night OFF OFF OFF Delayed Night OFF OFF Wireless sensor Fire/gas Immediate Day and Night OFF Keychain transmitter OFF Pag. 8

Position Alarm memory TABLE 3 Sensors and keychain transmitters Burglary Fire gas Configuration Progr. 1 Pyrpelectric Immediate Delayed Day Night 2 NC Line Immediate Delayed Day Night 3 Tamper 4 Wireless sensor 1 Immediate Delayed Day Night 5 Wireless sensor 2 Immediate Delayed Day Night 6 Wireless sensor 3 Immediate Delayed Day Night 7 Wireless sensor 4 Immediate Delayed Day Night 8 Wireless sensor 5 Immediate Delayed Day Night 9 Wireless sensor 6 Immediate Delayed Day Night 10 Wireless sensor 7 Immediate Delayed Day Night 11 Wireless sensor 8 Immediate Delayed Day Night Wireless sensor 9 Immediate Delayed Day Night 13 Wireless sensor 10 Immediate Delayed Day Night 14 Wireless sensor 11 Immediate Delayed Day Night 15 Wireless sensor Immediate Delayed Day Night 16 Wireless sensor 13 Immediate Delayed Day Night 17 Wireless sensor 14 Immediate Delayed Day Night 18 Wireless sensor 15 Immediate Delayed Day Night 19 Wireless sensor 16 Immediate Delayed Day Night 20 Wireless sensor 17 Immediate Delayed Day Night 21 Wireless sensor 18 Immediate Delayed Day Night 22 Wireless sensor 19 Immediate Delayed Day Night 23 Wireless sensor 20 Immediate Delayed Day Night 24 Wireless sensor 21 Immediate Delayed Day Night 25 Wireless sensor 22 Immediate Delayed Day Night 26 Wireless sensor 23 Immediate Delayed Day Night 27 Wireless sensor 24 Immediate Delayed Day Night 28 Wireless sensor 25 Immediate Delayed Day Night 29 Wireless sensor 26 Immediate Delayed Day Night 30 Wireless sensor 27 Immediate Delayed Day Night 31 Wireless sensor 28 Immediate Delayed Day Night 32 Wireless sensor 29 Immediate Delayed Day Night 33 Wireless sensor 30 Immediate Delayed Day Night 34 Wireless sensor 31 Immediate Delayed Day Night 35 Wireless sensor 32 Immediate Delayed Day Night 36 Wireless sensor 33 Immediate Delayed Day Night 37 Wireless sensor 34 Immediate Delayed Day Night 38 Wireless sensor 35 Immediate Delayed Day Night 39 Wireless sensor 36 Immediate Delayed Day Night 40 Wireless sensor 37 Immediate Delayed Day Night 41 Wireless sensor 38 Immediate Delayed Day Night 42 Wireless sensor 39 Immediate Delayed Day Night 43 Wireless sensor 40 Immediate Delayed Day Night 44 Keychain transmitter 1 45 Keychain transmitter 2 46 Keychain transmitter 3 47 Keychain transmitter 4 48 Keychain transmitter 5 49 Keychain transmitter 6 50 Keychain transmitter 7 51 Keychain transmitter 8 52 Keychain transmitter 9 53 Keychain transmitter 10 54 Keychain transmitter 11 55 Keychain transmitter Pag. 9

7.1. PROGRAMMING of: incorporated pyroelectric, NC line, wireless sensors and keychain transmitters 1) Rotate the service key to OFF position. 2) Verify that the tamper button is open (Telelink VP-7N must not be fixed to wall). 3) Verify that dip is in the OFF position. 4) Rotate the service key to position. THE DAY ZE and NIGHT ZE LED will go. 5) Position dip 10 OFF and 11 (see Table 1 on page 8). 6) Position dip 6, 7, 8 and 9 as illustrated in Table 2 on page 8. 7) Position dip. 3 beeps will be emitted. In case of programming of the incorporated pyroelectric and the NC line, after that the 3 beeps are emitted another beep will be emitted to confirm that programming has taken place. 8) As far as the incorporated pyroelectric and NC line are concerned the programming ends here. Therefore omit points (9), (10) and (11) and proceed with () onwards. For the wireless sensors (burglary, fire/gas) and keychain transmitters proceed as follows: 9) Transmit an alarm signal with the sensor to be programmed (see instructions included with sensor), or press "Button 1" on the keychain transmitter to be programmed. a) The Telelink VP-7N emits 1 beep to confirm that the code transmitted by the sensor or keychain transmitter has been memorized. b) If 2 beeps are emitted, this means that the code transmitted has already been memorized. c) If on the other hand 3 beeps are emitted, this means that the transmitted code cannot be memorised because the memory is full, that is all the codes allowed have been memorized: 40 for the sensors and for the keychain transmitters. 10) To program a second sensor with the same configuration of the previous, or another keychain transmitter, repeat operation (9). 11) If you want to program a second sensor with a different configuration of the previous, repeat operations (3), (6), (7) e (9). ) After having programmed the unit, we recommend filling in Table 3 on page 9. It is also advisable to number each sensor and keychain transmitter so that they can be easily identified. 13) If one or more sensors are cancelled, any successive sensors programmed will take the place of those cancelled starting from the lowest position (see Table 3 on page 9). The same thing applies for the remote key-chain transmitters. Example: If 20 sensors have been programmed and then 2 are cancelled, to be precise, the ones that occupy positions number 3 and, the first sensor subsequently programmed will occupy position number 3 and the following one, position number. 14) After having finished the programming, position dip switch on OFF. A long beep will be emitted. 15) Reposition the sliding cover. The VP-7N is not yet functional. To make it operative it is necessary to close the tamper switch (this is simply done fixing the unit to the wall). The DAY ZE and NIGHT ZE" LEDs go OFF and 2 beeps are emitted to signal that the VP-7N is operative in the disarmed mode. OFF 10 Pag. 10

7.2. CANCELLATI of the incorporated pyroelectric and the NC line 1) Rotate the service key to OFF position. 2) Remove the Telelink VP-7N from the wall and verify that the tamper button is open. 3) Verify that dip is in the OFF position. 4) Rotate the service key to position. THE DAY ZE and NIGHT ZE LEDs will go. OFF 5) Position dip 10 to and 11 to OFF (see Table 1 on page 8). 6) Consult Table 3 (filled in during the programming phase) to see the configuration of the device that must be cancelled (incorporated pyroelectric or NC line). Therefore, position the dips 6, 7, 8 and 9 according to Table 2 on page 8. Example: To cancel the incorporated pyroelectric sensor programmed as Immediate Day, position the dips 6, 7 and 8 to OFF and 9 to (see Table 2 on page 8). 10 7) Position dip to. 3 beeps will be emitted, followed after a few seconds by another 4 beeps to confirm that the cancellation of the selected device has taken place. 8) At the end of this operation reposition dip to OFF. A long beep will be emitted. 9) To also cancel the NC line repeat operations (3), (6), (7) and (8). 10) Reposition the sliding cover. The VP-7N is not yet functional. To make it operative it is necessary to close the tamper switch (this is simply done fixing the unit to the wall). The DAY ZE and NIGHT ZE" LEDs go OFF and 2 beeps are emitted to signal that the VP-7N is operative in the disarmed mode. Pag. 11

7.3. CANCELLATI of one or more wireless sensors (burglary, fire/gas) or keychain transmitters 1) Rotate the service key to OFF position. OFF 2) Remove the Telelink VP-7N from the wall and verify that the tamper button is open. 3) Verify that dip is in the OFF position. 4) Rotate the service key to position. THE DAY ZE and NIGHT ZE LED will go. 5) Position dip 10 to and 11 to OFF (see Table 1 on page 8). 10 6) Sensors Consult Table 3 on Page 9 (filled in during the programming phase) to see the configuration of the sensor that must be cancelled. Therefore, position the dips 6, 7, 8 and 9 according to Table 2 on page 8. Transmitters Position the dips 6, 7, 8 e 9 according to the indications on the last line of Table 2 on page 8. Example: If 5 sensors have all been programmed as Immediate Day and you only wish to cancel 2, position the dips 6, 7, 8 and 9 all to OFF (see Table 2 on page 8). 7) Position dip to. 3 beeps will be emitted. 8) Transmit with the device to be cancelled.. As far as the keychain transmitters are concerned it is sufficient to press "Button 1". 4 beeps will be emitted to confirm cancellation. 9) To cancel other sensors or transmitters with the same configuration of the previous, repeat for each one operation (8) above. 10) At the end of the operation reposition the dip to OFF. A long beep will be emitted. 11) To cancel a sensor with a different configuration of the previous, repeat operations (6), (7), (8), (9) e (10). ) Reposition the sliding cover. The VP-7N is not yet functional. To make it operative it is necessary to close the tamper switch (this is simply done fixing the unit to the wall). The DAY ZE and NIGHT ZE" LEDs go OFF and 2 beeps are emitted to signal that the VP-7N is operative in the disarmed mode. Pag.

7.4. CANCELLATI of a group of sensor with the same configuration or of all keychain transmitters 1) Rotate the service key to OFF position. 2) Remove the Telelink VP-7N from the wall and verify that the tamper button is open. 3) Verify that dip is in the OFF position. 4) Rotate the service key to position. THE DAY ZE and NIGHT ZE LED will go. 5) Position dip 10 and 11 to OFF (see Table 1 on page 8). 6) Sensors Consult Table 3 on page 9 (filled in during the programming phase) to see the configuration of the group of sensor that must be cancelled. Therefore, position the dips 6, 7, 8 and 9 according to Table 2 on page 8. Transmitters Position the dips 6, 7, 8 e 9 according to the indications on the last line of Table 2 on page 8. Example: If 5 sensors have all been programmed as Immediate Day and you wish to cancel them all, position the dips 6, 7, 8 and 9 all to OFF (see Table 2 on page 8). 7) Position dip to. 3 beeps will be emitted followed after a few seconds by another 2 beeps to confirm the cancellation of the selected devices. 8) At the end of the operation reposition the dip to OFF. A long beep will be emitted. 9) Reposition the sliding cover. The VP-7N is not yet functional. To make it operative it is necessary to close the tamper switch (this is simply done fixing the unit to the wall). The DAY ZE and NIGHT ZE" LEDs go OFF and 2 beeps are emitted to signal that the VP-7N is operative in the disarmed mode. 7.5. CANCELLATI total memory 1) Rotate the service key to OFF position. 2) Remove the Telelink VP-7N from the wall and verify that the tamper button is open. 3) Verify that dip is in the OFF position. 4) Rotate the service key to position. THE DAY ZE and NIGHT ZE LED will have a fixed light. 5) Position dips 10 and 11 to (see Table 1 on page 8). 6) Position the dip to. 3 beeps will be emitted followed shortly by another 2 beeps to confirm cancellation of all the memory. All that had been programmed is now cancelled. 7) At the end of the operation reposition the dip to OFF. A long beep will be emitted. 8) Reposition the sliding cover. The VP-7N is not yet functional. To make it operative it is necessary to close the tamper switch (this is simply done fixing the unit to the wall). The DAY ZE and NIGHT ZE" LEDs go OFF and 2 beeps are emitted to signal that the VP-7N is operative in the disarmed mode. OFF OFF 10 10 11 Pag. 13

7.6. PROGRAMMING OF TLM-18VRP WIRELESS SIREN 1) Remove the cover and the internal panel of the siren and position the sirens dip 3 to and dips 4, 5 to OFF. 2) Power up the siren leaving the tamper button opened. A beep will be emitted approximately every 7 seconds. 3) Arm the control panel using one of the programmed keychain transmitters. This operation must be carried out with the tamper button of the control panel closed. 4) The TLM-18VRP will emit 3 beeps to confirm that self-learning of the siren has taken place. 5) Position dip 3 to OFF. 6) Remove the sirens power supply (battery and mains power adaptor). 7) Rotate the service key of the control panel to OFF position. 8) Verify that the tamper button of the control panel is opened. 9) Verify that dip on the control panel is positioned to OFF. 10) Rotate the service key to position. DAY ZE and NIGHT ZE LEDs will go. 11) Select on the control panel programming of the wireless sensors configured as Immediate Day position the dips as follows: Dip 10 to OFF Dip 11 to Dip 6, 7, 8 e 9 all to OFF ) Position on control panel dip to. 3 beeps are emitted. 13) Power up the siren leaving the tamper button open. 14) Close the tamper button. The siren emits 3 beeps and triggers a tamper alarm. This code is learned by the control panel. 15) Reposition on the control panel dip to OFF. A long beep is emitted. 16) Proceed with the installation of the TLM-18VRP following the siren instruction manual. The tampering of the siren will also trigger the alarm of the VP-7N. Pag. 14

7.7. PROGRAMMING OF TLM-21VRP WIRELESS SIREN 1) Remove the cover and the internal panel of the siren and position the sirens dip 5 to and dips 6, 7 and 8 to OFF. 2) Power up the siren leaving the tamper button opened. A beep and a flash will be emitted approximately every 10 seconds. 3) Arm the control panel using one of the programmed keychain transmitters. This operation must be carried out with the tamper button of the control panel closed. 4) The siren will emit 3 beeps and 3 flashes to confirm the self-learning of the code. 5) Position dip 5 to OFF. 6) Remove the sirens power supply (battery and mains power adaptor). 7) Rotate the service key of the control panel to OFF position. 8) Verify that the tamper button of the control panel is opened. 9) Verify that dip on the control panel is positioned to OFF. 10) Rotate the service key to position. DAY ZE and NIGHT ZE LEDs will go. 11) Select on the control panel programming of the wireless sensors configured as Immediate Day position the dips as follows: Dip 10 to OFF Dip 11 to Dip 6, 7, 8 e 9 all to OFF ) Position on the control panel dip to. 3 beeps are emitted. 13) Power up the siren leaving the tamper button open. 14) Close the tamper button. The siren emits 3 beeps and 3 flashes and triggers a tamper alarm. This code is learned by the control panel. 15) Reposition on the control panel dip to OFF. A long beep is emitted. 16) Proceed with the installation of the TLM-21VRP following the instructions supplied with the siren. The tampering of the siren will also trigger the alarm of the VP-7N. Pag. 15

8.0. ZE DESCRIPTI The Telelink VP-7N has 42 zones subdivided as follows: 1 zone for incorporated sensor 1 zone for NC line 40 zones for wireless sensors and sirens Each zone can be programmed as burglary, fire/gas, immediate, delayed, Day or Night. The Delayed zone (both Day or Night) have a fixed entrance time of 10 seconds. The intrusion of a delayed zone provokes the emission of an acoustic signal as a pre -alarm for the entire time of entrance (a beep approximately every second). At the end of the 10 seconds, if the system has not been disarmed, an alarm cycle will be activated. The exit time is of 25 seconds from the moment that the Telelink VP-7N is armed. During the exit time no acoustic signal is emitted, but the DAY ZE or "NIGHT ZE LED flashes depending on if the VP-7N is armed in Day or Night mode. The Day zones are only activated when the system is armed in Day mode. The Night zones are activated with the system armed in both Night and Day. The Fire or Gas, Panic and Tamper zones are always active whether the system is armed in Day, Night mode or totally disarmed. The above is summarized in the following table: VP-7N armed "DAY" VP-7N armed "NIGHT" VP-7N "DISARMED" Incorporated sensor N.C. Line Active (configured Day and Night) Active (configured Day and Night) Active (if configured Night) Not active (if configured Day) Active (if configured Night) Not active (if configured Day) Not active Not active DAY Zone Active Not active Not active NIGHT Zone Active Active Not active Fire or gas zone Active Active Active Panic Active Active Active Anti-tamper Active Active Active Pag. 16

9.0. ARMING OF SYSTEM 9.1. FULL ARMING (DAY mode) Press Button 1 on the three channel keychain transmitter. The emission of a beep and a flash of the red LED DAY ZE indicate that the system has been fully armed ( DAY mode). The LED flashes for the entire exit time of 25 seconds during which the Telelink VP-7N any alarm signal will be disregarded. Button 1 At the end of the exit time, the LED will go. From this moment the Telelink VP-7N is armed. Any alarm signal from the sensors configured DAY or NIGHT triggers an alarm cycle for the programmed time. After each alarm cycle, the Telelink VP-7N will reset and be ready for another alarm. If the alarm cycle counter is activated (see paragraph.0.), the Telelink VP-7N will carry out a maximum of 4 alarm cycles for each type of alarm detected. To signal the "DAY" arming mode, the TLM-18VRP wireless sirens will emit a beep (excludible), while the TLM-21VRP wireless sirens will emit a flash and a beep (excludible). 9.2. PARTIAL ARMING (Night mode) Press Button 2 on the three channel keychain transmitter. The emission of a long beep and a flash of the red LED NIGHT ZE indicates that the system has been partially armed ( NIGHT mode). The LED flashes for the entire exit time of 25 seconds during which the Telelink VP-7N will disregard alarm signals. At the end of the exit time, the LED will go. Button 2 From this moment the Telelink VP-7N is armed. Any alarm signal from the sensors configured NIGHT trigger an alarm cycle for the programmed time. All sensors configured DAY are excluded. After each alarm cycle, the Telelink VP-7N will reset and be ready for another alarm. If the alarm cycle counter is activated (see paragraph.0.), the Telelink VP-7N will carry out a maximum of 4 alarm cycles for each type of alarm detected. The partial arming will not be signalled by the wireless sirens installed. 9.3. DISARMING Press Button 1 on the three channel keychain transmitter. The emission of 2 beeps and the turning OFF of the DAY ZE or NIGHT ZE LED (depending on how the system is armed Day or Night), indicate that the system has been disarmed (OFF). If while the system was armed in Day or Night mode, an alarm event have been detected, then the alarm memory function will Button 1 initiate when the Telelink VP-7N is disarmed and remains active until the control panel is once again armed (see paragraph 14.0.). To signal the disarming mode, the TLM-18VRP wireless sirens will emit 2 beeps (excludible), while the TLM-21VRP wireless sirens will emit 2 flashes and 2 beeps (excludible). ATTENTI With the system disarmed, Fire, Gas and Tamper alarms, Panic and Medical Distress functions always remain active. Pag. 17

10.0. TEST FOR NC LINE AND WIRELESS SENSORS Once Telelink VP-7N and all peripherals have been installed, it is possible to verify the functioning of the NC line and the range of the wireless sensors without provoking an alarm. 1) Disarm the VP-7N with the supplied keychain transmitter. 2) The opening of the NC line, the intrusion of the zone protected by the incorporated sensor and the intrusion of the zones protected by the peripherals (IR-32VRP, MG-1P, MG-3P etc.) provoke the lighting of the DAY ZE or NIGHT ZE LED depending on how the NC line and sensors have been programmed (Day or Night). 3) The DAY ZE or NIGHT ZE LED lights every time that there is an intrusion in the zone. Pag. 18

11.0. FUNCTIING In case of burglary, fire or gas, panic and tamper alarm, the Telelink VP-7N activates the following devices: 1) Incorporated siren The siren sounds for the entire time set (2 or 4 minutes). N.B. In case of panic alarm, the siren sounds only if an audible panic alarm is chosen. 2) Wireless siren (TLM-18VRP (indoor) and TLM-21VRP (outdoor)) - If the alarm time selected is 2 minutes, the sirens sound for 2 minutes. - If the alarm time selected is 4 minutes, the indoor siren sounds for 4 minutes, while the outdoor siren sounds for 3 minutes which is the maximum alarm time of the siren. N.B. In case of panic alarm, the siren sounds only if an audible panic alarm is chosen. 3) Alarm relay The relay remains attracted for the entire alarm time selected (2 or 4 minutes). The relay may be used, for example, to activate other hardwire sirens with back-up power or telephone diallers. A) After an alarm cycle the Telelink VP-7N resets itself and is ready for another alarm. B) An alarm can be interrupted by pressing "Button 1" of the keychain transmitter. VP-7N armed The interruption of a burglary, fire/gas, hold-up and tamper alarm will cause: - The interruption of incorporated siren and remote indoor and outdoor sirens. - The deactivation of the alarm relay. - Disarming of the VP-7N (2 beeps will be emitted). - The alarm memory activation. - The wired telephone dialler activated by the relay will not interrupt the alarm calling cycle. VP-7N disarmed Permanent interruption of a fire/gas, hold-up and tamper alarms. C) Tamper violation of the TLM-18VRP and TLM-21VRP wireless sirens will trigger an alarm of the Telelink VP-7N which consequently will activate all other wireless devices installed (sirens, etc.). Pag. 19

.0. ALARM CYCLE COUNTER Counter activated (dip 4 ) In case of alarm (burglary, hold-up, fire and tamper), the Telelink VP-7N carries out, for the same alarm cause, a maximum of 4 alarm cycles of the duration of the time set with dip 2. After which, the Telelink VP-7N will no longer trigger by the same alarm cause. It will however be triggered if the cause of alarm is different. Example: - If the NC line is triggered for 4 consecutive times, the Telelink VP-7N carries out each time an alarm cycle. If the NC line is triggered a fifth time, the Telelink VP-7N will no longer trigger by the same alarm cause. It will however be triggered if the cause of alarm is different. - If a wireless sensor or the magnetic contact triggers an alarm for 4 consecutive time, the Telelink VP-7N carries out an alarm cycle each time. If the same sensor or magnetic contact is triggered a fifth time, the Telelink VP-7N will not alarm. Deactivated counter (dip 4 OFF) In case of alarm (burglary, hold-up, fire and tamper), the Telelink VP-7N carries out an alarm cycle of the duration of the time set with dip 2. The alarms will continue based on the alarms triggered. Example - If the NC line opens and then closes for an indefinite number of times, Telelink VP-7N effect an alarm cycle for each event. - If the NC line opens and stays open, Telelink VP-7N effects only one alarm cycle. A new alarm cycle will be effected if the NC line is closed and then opened again. - In the case of the PIR sensors or wireless magnetic contacts, an alarm cycle is triggered every time the sensor transmits the signal. 13.0. HOLD-UP ALARM To call for help in the case of danger or medical distress, press Button 3 on the keychain transmitter as shown on the design on the right. The button can be easily found by sliding the protection cover towards. The hold-up function can be activated at any time regardless at the status of the alarm system (armed or not armed). The hold-up alarm provoked the immediate activation of the devices listed in points 1), 2) and 3) on paragraph 11.0. Button 3 Slide 13.1. HOLD UP ALARM RESET A hold up alarm can be blocked by pressing Button 1 of the keychain transmitter. Button 1 Pag. 20

14.0. ALARM MEMORY VP-7N armed If during arming in "Day" or "Night" mode one or more alarm events occur, when the Telelink VP-7N is disarmed, the "Alarm memory" will be activated. Only the first alarm event triggered will be indicated by the short flashing of the "NIGHT ZE" LED and long flashing of the "DAY ZE" LED and by the emission of short and long beeps (the beeps can be excluded by positioning dip-switch 5 to OFF - see Table on page 6). To limit the number of flashes and beeps emitted the following system has been used: The "NIGHT ZE" LED short flashing and short beep indicates each unit. The "DAY ZE" LED long flashing and long beep indicates ten units. Looking at the Table 3 on Page 9, the first column indicates the number of flashes and beeps emitted, while the second column shows the devices (incorporated pyroelectric sensor, NC line, tamper, wireless sensors and keychain transmitters) associated to the position occupied in the first column. Therefore, from the number of flashes and beeps emitted, it is possible to see which of the devices has gone into alarm. Examples: 1) One short flash of the "NIGHT ZE" LED and one short beep, indicate an alarm triggered by the incorporated pyroelectric sensor. 2) 9 short flashes of the "NIGHT ZE" LED and 9 short beeps indicate an alarm on sensor number 6. 3) One long flash of the "DAY ZE" LED and one long beep, plus 3 short flashes of the "NIGHT ZE" LED and 3 short beeps, indicate an alarm on sensor number 10. 4) 2 long flashes of the "DAY ZE" LED and 2 long beeps, plus 5 short flashes of the "NIGHT ZE" LED and 5 short beeps indicate an alarm on sensor number 22. 5) 4 long flashes of the "DAY ZE" LED and 4 long beeps, plus 5 short flashes of the "NIGHT ZE" LED and 5 short beeps indicate the hold-up alarm activated by the second programmed keychain transmitter. VP-7N disarmed If during disarming mode one or more alarm events occur, when the Telelink VP-7N is newly armed, the system will not arm, but 2 beep will be emitted and the "Alarm memory" will be activated to indicate, whit the above described mode, the first alarm event triggered. At this point, to arm the Telelink VP-7N press "Button 1" on the keychain transmitter to reset the alarm memory, then press newly "Button 1" (to arm in "Day" mode) or "Button 2" (to arm in "NIGHT" mode). 14.1. ALARM MEMORY RESET The alarm memory can be cancelled by pressing "Button 1" of the keychain transmitter. The emission of a short beep will confirm alarm memory. Pag. 21

15.0. CNECTIS The Telelink VP-7N is equipped with a 7 poles terminal block which can be accessed by removing the rear cover. Tamper switch Rear view 1 2 3 4 5 6 7 N.C. line NO NC C +14 Vdc Auxiliary power output Negative Battery Terminal block Alarm relay Negative output which signals the system status (DAY and NIGHT mode) 1, 6 - Normally closed line (N.C.). The line closes toward (-) negative. The line must remain closed even if it is not utilized. 2,3,4 - NO, NC, C - Free contacts alarm relay - (I max 1A). The relay is activated each time that the Telelink VP-7N detects an alarm and remains attracted for the entire alarm time selected with the dip 2 (2 or 4 minutes). The relay can be used to activate hardwire sirens and/or telephone dialler. 5 - Negative output which signals in DAY and NIGHT mode that the panel is armed (I max 20 ma). 6 - Negative 7 - + 14 Vdc - Auxiliary positive power output - (I max 50 ma). The output is active only with the service key in position. Upon request this output is active also with the key in OFF position. Pag. 22

16.0. TECHNICAL CHARACTERISTICS Power: adaptor 230 Vac +/- 10% (50 Hz) 14 Vdc Current drain (LED off): 2.5 ma Current drain (DAY mode): 8 ma Current drain (NIGHT mode): 5 ma Acoustic output power: 100 db at three metres Minimum guaranteed range: 20 metres Working frequency: 433.92 MHz Alarm time: 2 or 4 minutes (programmable) Exit time: 25 seconds Entrance time: 10 seconds Free relay contacts: Imax = 1 A Operating temperature range: -10 C to +50 C Battery housing: V - 700 mah SMD technology Dimensions: 105x170x45 mm Weight (with battery): 530 g Infrared section Dual element piroelectric sensor Volumetric Fresnel lens Protection facets: on three levels Horizontal aperture: 110 degrees Maximum coverage range: 10/ metres The Telelink VP-7N is supplied with: 2 three coded channel keychain transmitters PEG-3 Adaptor 230 Vac +/- 10% 14 Vdc V - 700 mah incorporated battery Mounting accessories User s manual Do not litter. Separate and discard the packaging materials in the containers (depending on the rules in force at the place of residence). Do not litter. Turn the device and the batteries over to a designated disposal at the end of lifetime. Latest revision 05-23-2011 Software 25-11-04 Rev. 1.1 Pag. 23

Notes Pag. 24