3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Area Coverage Field of View Load Type Sensor Type Time Delay Voltage Rating Material, Color, and Finish Finish Dimensions and Weight Size Descriptions Additional Information WHT Pir Ceiling Mount Occupancy Sensor Pass & Seymour/Legrand Commodity Description Description Long Description Product Type Pass & Seymour/Legrand Passive Infrared Sensor, Sensor; Passive Infrared Sensor; 1200 SQ FT Area Coverage; Ceiling Mounting; Application Commercial, Open Office, Conference and Computer Room, Kitchenette and Any Open Space Without Partition 0.4000 (lbs/each) Lighting Occupancy Sensors 1200 SQ FT 110 Deg Vertical, 360 Deg Horizontal INCANDESCENT/FLUORESCENT PASSIVE INFRARED 15 SEC TO 30 MIN 24 VDC WHITE 3.3 INCH DIA X 2.2 INCH D Manufacturer Information Brand Pass and Seymour GTIN 00785007703849 Manufacturers Part Number UPC 785007703849 Applicable Standard NEMA WD-1/WD-6; Enclosure Material Thermoplastic/UV Resistant Plastic; Indicator Type Light Red LED; Lens Type Multi-Zone Fresnel; Includes 11 Milliampere Power Pack; Mounting Options Ceiling Tile or 3 Inch Round Mud Ring MOTION SENSING DEVICES WHT PIR CEILING MOUNT OCCUPANCY SENSOR PASSIVE INFRARED SENSOR, SENSOR; PASSIVE INFRARED SENSOR; 1200 SQ FT AREA COVERAGE; CEILING MOUNTING; APPLICATION COMMERCIAL, OPEN OFFICE, CONFERENCE AND COMPUTER ROOM, KITCHENETTE AND ANY OPEN SPACE WITHOUT PARTITION Occupancy Sensor
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Taxonomies, Classifications, and Categories Category Description COMMERCIAL GRADE SWITCHES Type SENSOR Availability Status Packaging Carton 20 Package 1 Weight Per each 0.4 Uses, Certifications, and Standards Application Approval Mounting Inactive COMMERCIAL, OPEN OFFICE, CONFERENCE AND COMPUTER ROOM, KITCHENETTE AND ANY OPEN SPACE WITHOUT PARTITION UL (CANADA AND US) CEILING
Technology Passive Infrared Sensors (PIR) Using a patented fresnel lens which minimizes optical aberrations, each Legrand/Pass & Seymour PIR sensor breaks its coverage area into zones. Upon detecting an infrared energy change within a zone, one of the elements in the dual-element pyroelectric sensing device of an occupancy sensor generates a positive pulse. Within milliseconds, the other element produces a negative pulse and the lights are turned on. Vacancy sensors turn lights off when the room is vacant for a period of time, or when there is no infrared energy detected within a zone. Passive infrared sensors are unable to detect occupancy around barriers, and are more effective when sensing movement across their field of sight rather than towards or away from it. All Legrand/Pass & Seymour PIR occupancy sensors feature: n Patented fresnel lenses with multi-segment design n Dual-element pyroelectric sensors n Low-profile design n Daylight filter systems n Adjustable settings for time and sensitivity n Custom Detection Signature Analysis for high immunity to RFI and EMI, and reliability n Self-adaptive technology is available on some models Ultrasonic Sensors Ultrasonic sensors use a multi-directional transmitter/receiver system to broadcast ultrasonic sound waves generated by a quartz crystal oscillator, and then measure the amount of time it takes the waves to return. Movement within the area results in the sound waves returning to the sensor at a slower or faster rate, and thus occupancy is detected. Ultrasonic sensors broadcast in three dimensions, and are therefore able to detect smaller movements than PIR sensors. Proper placement of the sensors is essential as sound waves can escape through open doorways, resulting in false triggering. While Legrand/Pass & Seymour ultrasonic sensors use special circuitry to filter out air-flow movement caused by HVAC equipment or fans, sensors should be kept away from breezy areas. Also, heavy carpeting and other sound-absorbing materials used in the construction of a room will reduce coverage. Legrand/Pass & Seymour ultrasonic occupancy sensor features: n Temperature- and humidity-resistant tuned receivers n Signal Processing Circuitry n Solid-state, crystal-controlled transmitter n Adjustable controls for time and sensitivity Dual Technology Dual Technology sensors combine PIR and Ultrasonic sensing in one device. This minimizes false ONs and nuisance OFFs. Sensitivity adjustments and user selectable operational characteristics make dual technology sensors the most versatile, even in the most difficult installations. Technology L-2 Use dual technology sensors for the most demanding sensor applications. Odd shaped rooms, lots of partitions, and changing floor plans can be handled best by dual technology sensors.
Catalog P&S Model Page # Best Suited For: Residential Occupancy Sensors Applications RW500U L-5 Storage rooms, walk-in closets, pantries, garage where no neutral is available RWU600U L-5 Storage rooms, walk-in closets, pantries, garage where a neutral is available Residential Vacancy Sensors (T24 Compliant) RW500B L-4 Bedrooms, basements bathrooms, laundry rooms, where no neutral is available RWU600B L-4 Bedrooms, basements bathrooms, laundry rooms, where a neutral is available RW600BTC L-4 Bedrooms, basements bathrooms, laundry rooms, where no neutral is available 3-Way Residential Occupancy/Vacancy Sensor RW3U600 L-6 Any room/hall with multiple entrances allows manual ON/OFF control from both locations. Can be switched between occupancy and vacancy. RW3U603 L-6 T24 Compliant. Any room/hall with multiple entrances allows manual ON/OFF control from both locations. Can be switched between occupancy and vacancy. Residential Occupancy/Vacancy Sensor with Dimmer RWDU500 L-7 Any room where adjustable light level is desired Commercial Passive Infrared (PIR) Wall Box Sensors PTWSP250 L-8 Small offices, closets, utility rooms with no partitions or obstructions WSP250 L-8 Small offices, closets, utility rooms with no partitions or obstructions OS300S L10 Small offices, closets, small conference rooms with no partitions or obstructions OSR300S L-11 Small rooms with two individually-controlled loads or bi-level lighting with no partitions or obstructions Commercial Passive Infrared (PIR) and Ultrasonic Wall Sensors WDT100 L-9 WDT200 L-9 Commercial Passive Infrared (PIR) Ceiling Sensors Small offices, executive suites, conference rooms, break rooms. CS500 L-13 Open offices, lunch, utility, storage, and computer rooms with no partitions or obstructions L-13 Larger rooms, up to 1200 sq. ft., with open floor plans, no partitions or obstructions Commercial Passive Infrared (PIR) Wall or Ceiling Mount Sensors HS1001 L-12 Hallways, or aisles WA1001 L-12 Entrances, vestibules, classrooms, for wide-angle applications Commercial Ultrasonic Ceiling Mount Sensors CSU600 L-14 Offices, computer, meeting, copy, and restrooms CSU1100 L-14 Offices, lunch, break and classrooms, restrooms, and conference rooms CSU2200 L-14 Offices, lunch, break and classrooms, restrooms, conference rooms, halls, storage areas Commercial Dual Technology Sensors CSD1000 L-15 Meeting, conference and classrooms, restrooms, dressing rooms, libraries, interview rooms, testing areas, lunch and break rooms Timers RT1 L-18 Closets, bathroom fans, exhaust fans, heat lamps, bedrooms RT12 L-19 Garages, basements, laundry rooms, fans, motors, landscape lights RT24 L-19 Exterior lights, landscape lighting, security lighting, holiday lighting 97015, 30, 60 L-20 Bathroom fans, heat lamps, guest rooms 97115, 30, 60 L-20 Bathroom fans, heat lamps, guest rooms where a hold function is desired 97352 L-20 Dual control for bathroom light and fan L-3 Applications
Features Commercial Occupancy Sensors Ceiling Mount Passive Infrared (PIR) n ASIC technology reduces components and enhances reliability. n Pulse count processing eliminates false offs without reducing sensitivity. n Detection signature analysis eliminates false triggers and proves immunity to RFI and EMI. n Low-profile design ensures a clean and uncluttered ceiling appearance. n User-adjustable time delay from 15 seconds to 30 minutes by two minute increments. n Sensitivity is programmed through a DIP switch and has four settings from minimum to maximum. n Dual-element, temperature compensated pyroelectric sensor. n Mounting options: ceiling tile or 3.0 inch round mudring. n Units per power pack: up to 13. n culus listed. n 5-year warranty. Override and Catalog Output Number Description Rating Coverage Disable Color Low-Profile Ceiling Mount Sensors CS500 PIR Occupancy Sensor 24VDC Input, requires 360, 500 sq. ft. No White PIR Occupancy Sensor Power Pack 11mA 360, 1200 sq. ft. No White Reference Page L-16 for Power Packs. CS500/ Wiring DIP Switch Settings 2.2" CS500 3.3" Mounting Coverage Extended Range Lens (Standard) Technical Specifications on Page S-143. High Density Lens CS500 L-13 Commercial Occupancy Sensors
Technical Specifications Technical Specifications Occupancy Sensors General Specifications 1. Occupancy sensors shall control lighting and/or HVAC in the sensed area only. 2. Controlled lighting and/or HVAC zones shall not be larger than 2500 sq. ft. 3. The contractor shall be responsible for a complete, operable system, and installation should be warranted for a period of one year after acceptance. 4. The product shall be warranted for a period of (5) five years for wall switch sensors, ceiling sensors, and power packs. 5. Occupancy sensors shall be installed as per manufacturer s recommendations. 6. Specific low-voltage wire surface routing shall be approved by the facilities engineer. 7. Sensor and control unit manufacturer must have experience in the lighting and/or HVAC controls industry equal to a minimum of (5) five years with a minimum of (5) five similar projects. 8. Contractor shall be responsible for contacting the manufacturer for proper placement and adjustment of sensor. Wall Box Switches WSP250, WDT100*, WDT200*, OS300S, OSR300S Features & Benefits Zero Crossing This feature ensures the closing of the contacts as close to 0 as possible, extending the life of the relay contacts, and limiting the effect of inrush current from some electronic ballasts. ASIC Chip Application Specific Integrated Component chip is a custom-designed microprocessor that improves reliability and boosts immunity to RFI and EMI. 30 sec. - 30 min. Time Delay Such a large range allows users to adjust time delay to fit the application and ensure maximum savings without compromising convenience. 180 Coverage Provides detection even along the wall it is mounted on. Maximum Rating Allows for the combining of potential savings with room size. Wall switches that offer too much wattage handling capacity are used in larger rooms where ceiling sensors should be used, compromising the reliability of the installation. Self-Adaptive On the OS units only: Units automatically adjust the delay time by monitoring room usage patterns. No user adjustment required, automatically sets delay time for most efficient use of energy. 2 relays for bi-level switching The OSR300S is designed for areas with two lighting zones or bi-level lighting applications. Adjustable Sensitivity Enables the installer or user to adjust the sensitivity level to suit the application. Voltage Drop Protection Protects the electronics to ensure long-term performance. Five-Year Warranty Allows installer or user to receive a replacement or refund if a sensor is found to be defective within 5 years of purchase. *Dual Technology Wall- and Ceiling-Mount Sensors Feature WA1001 HS1001 CS500/ CSU600/1100/2200 CSD1000 Technology Passive Infrared Passive Infrared Passive Infrared Ultrasonic* Dual Technology Coverage Pattern Wide Angle Long Range 360 360 360 Mounting Method Wall or Ceiling Wall or Ceiling Ceiling Ceiling Ceiling Adjustable Sensitivity Viewing Range 1200 sq. ft. 90 x 20 ft. 500/1200 sq. ft. 600/1100/2200 sq. ft. 1000 sq. ft. Fresnel Lens** N/A ASIC 5-Year Warranty * Provides occupancy detection around obstacles. ** Dual tech has both Ultrasonic and PIR Fresnel lens. Improves reliability and boosts immunity to RFI and EMI. Occupancy Sensors S-138 Power Packs & Add-A-Relay PWP120277 & AR120/277 Features Load Rating at 120V 20A Ballast 13A Incandescent Load Rating at 277V 20A Ballast Add-A-Relay Rating at 120V 20A Ballast 13A Incandescent Add-A-Relay Rating at 277V 20A Ballast HP Rating 1HP Output Rating* 24VDC; 225mA *PWP unit only. Project Location/Type Mounting Method Sized to Fit into Approved Enclosure for Plenum Applications Teflon-Coated Leads Five Year Warranty 1/2" Knockout
Typical Specifications Motion sensor switches shall be culus Listed, and California Title 24 Compliant as provided by Legrand/Pass & Seymour. Sensors shall be ceiling mount type, capable of detecting infrared emissions from personnel movement and switching incandescent and fluorescent lighting loads on and off. Motion sensor switches shall make use of optics that operate within a 110 field of view. Motion sensors may be mounted in a drop ceiling, solid ceiling, or wall. Motion sensor switch must be used in conjunction with the PWP120 (120VAC supply) or PWP277 (277VAC supply) switching modules, and capable of handling additional loads with the support of an Add-A-Relay AR120/277. Conforms to NEMA WD-1 and WD-6. Catalog Number r CS500 r Performance Technical Specifications PIR Occupancy Ceiling Sensors CS500, Description Ceiling Sensor, 500 sq. ft. Ceiling Sensor, 1200 sq. ft. 2.2" CS500 3.3" Technical Specifications Electrical Supply Voltage Minimum Supply Voltage Maximum Supply Voltage Sensor Output + 24VDC Typical + 20VDC + 30VDC + 24VDC for external relay DC coil drive Maximum Output Current: 100mA DC Sensor Technology Passive Infrared Time Delay 15 sec. to 30 min. Light Level Adjustment No Sensitivity Adjustment Spectral Response 6 to 14 µm Field of View 110 Vertical, 360 Horizontal Coverage Up to 900 sq. ft. Indicator Light Red LED flashes when motion is detected Lens Type Multi-zone fresnel type Environment Temperature Range 0 C to 35 C Non-condensing Relative Humidity 20 to 90% Mechanical Enclosure Material Color Thermoplastic, UV-resistant plastic White Third Party Compliance culus Listed UL508 and C22.2 No. 14 California Title 24 Compliant CS500, Wiring Diagram Project Location/Type Wiring Diagrams on Page L-13. S-143 CS500,