LA AUDIT ASSISTANCE SURVEY: Pre-survey checklist

Similar documents
Statutory Compliance Checklist

FIRE SAFETY LOGBOOK ADDRESS OF PREMISES NOMINATED RESPONSIBLE PERSON

HEALTH AND SAFETY COMPLIANCE AUDIT

LYHA Fire Safety Policy

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire Risk Assessment 2017

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

STATEMENT OF THE HEALTH AND SAFETY STRATEGY FOR THE SYDNEY RUSSELL SCHOOL

Allfire Site No. a division of Allsaved Ltd. Fire Safety Log Book. Premises Address: Responsible Person:

Fire Procedures. April 2016

Fire Safety Protocol

FIRE SAFETY LOG BOOK

HEALTH & SAFETY POLICY. Saint Gabriel s Parish House Glasgow Terrace Churchill Gardens Pimlico Westminster London SW1V 3AA

PREMISES FIRE SAFETY LOGBOOK

FIRE SAFETY FOR PRE-SCHOOLS AND CHILDCARE FACILITIES GENERAL GUIDANCE COUNTY COMMITTEE LIMERICK CHILDCARE

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

H&S Forum. Fire Safety Policy Glascote Academy

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

FIRE PREVENTION, PROCEDURES AND RISK ASSESSMENT POLICY

Fire Safety Policy. Investing in success. Dukes Centre Dukes Avenue Kingston KT2 5QY 1. Policy

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

Fire Safety Management Audit Specification August 2017

Annemount School Fire Safety Policy This Policy is for the whole school including the EYFS

Fire Safety Register

FIRE RISK ASSESSMENT

7.0 SAMPLE PERMITS, FORMS AND CHECKLISTS SELF INSPECTION CHECKLIST

Health & Safety Policy HSP 03 Fire Safety Version Status Date Title of Reviewer Purpose/Outcome

WILTSHIRE POLICE FORCE PROCEDURE. Fire Safety Management

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Leaders in health, safety & environmental consultancy & training

FIRE SAFETY LOGBOOK PREMISES ADDRESS: LOG BOOK TO BE KEPT IN THIS LOCATION: DSFRS Log book Version 1.0 (October 2007)

FIRE SAFETY & EMERGENCY EVACUATION STRATEGY AND POLICY

Millfield Schools Fire Risk Prevention Policy

Fire. This policy applies to all members of our school community, including those within the EYFS setting.

NOTTINGHAM CITY HOMES

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

FIRE RISK ASSESSMENT

New Starter Safety, Health and Environment (SHE) Induction Checklist

THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS

Peponi House Preparatory School Nairobi, Kenya. Peponi House Fire Risk Prevention Policy

Fire Safety Policy. (The Regulatory Reform (Fire Safety) Order 2005) Last Reviewed: January Next Review: January 2019

The Basement Risk Assessment Form

Electrical Safety Policy and Management System

Leaders in health, safety & environmental consultancy & training

Property Health and Safety Compliance at Housing and Education Centres

Management Standard: Fire Safety

Fire Safety Log Book 41 page fire safety log book to record all your fire S afety checks Unique Fire Bordesley Green East Stechford Birmingham B33 8RU

Fire risk management plan. MH/05/Revised/06/17

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

Fire Risk Assessment Safety Checklist

Fire Safety, Procedures and Risk Assessment Policy

Arbour House. Fire Policy and Procedures

Fire and Bomb. Evacuation Policy

Wellsprings Primary School. Fire Emergency Evacuation Plan

FIRE SAFETY POLICY & EMERGENCY EVACUATION POLICY

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

Kings Fire Safety Policy

Community Health Partnerships. Guide to Landlord & Tenant responsibilities

F I R E S A F E T Y R E G I S T E R

Local Rules: Fire Safety

Fire Safety Policy Date: 0

St Edward s Oxford FIRE SAFETY POLICY

FIRE SAFETY POLICY. This policy document replaces any previously published documents and comes into effect September 2018.

Fire Evacuation Policy

FIRE SAFETY POLICY. This policy refers to both Wellington Senior School and Wellington Prep School

Fire Safety Audit: Part B - Questionnaire (Questionnaire Devised By Mr.R.R.Nair) Yes No x

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

GENERAL - Regulatory. Fire Policy, Risk Assessment and Prevention (ISI 12a) Fire Procedures (ISI 12b)

Fire Risk Management Policy. UK September 2017

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

OH&S WORKPLACE ASSESSMENT INSPECTION CHECKLIST

Insight a closer look at Classroom safety

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

FIRE SAFETY POLICY and FIRE SAFETY ARRANGMENTS

OAKTHORPE PRIMARY SCHOOL FIRE RISK ASSESSMENT POLICY NOVEMBER 2016

Health & Safety Policy

Health and Safety Policy for Offices and Staff Approved by the Unipol Board 17th December 2015

FIRE AND EMERGENCY EVACUATION PROCEDURES STARCROSS PRIMARY SCHOOL

FIRE PROCEDURES 1. APPOINTMENTS

GHS 8-4 Fire Policy and Procedures

FIRE AND EMERGENCY EVACUATION POLICY AND PROCEDURES

Fire Safety. A TUC guide for trade union activists

CLYST ST. MARY VILLAGE HALL

Fire Risk Assessment. ABC Car Workshop. Prepared for. Redacted

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

Near Howe Accident Risk Assessment

Fire Risk Assessment Report

FIRE SAFETY POLICY. Approval Approved by: University Court Date: March 28 th 2017

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

If there are more than ten people working other than on the ground floor,

Design Innovation Engineering Personified

Fire Safety Procedures and Associated Training

Fire Safety Management

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE EMERGENCY PLAN

Fire Risk Assessment 2016

EMERGENCY EVACUATION PLAN for FIRE

Walker Children s Club Health and Safety Policy

Transcription:

The items below will be asked about during the Audit Assistance Survey. This document can be used as a checklist to help prepare and to reduce time taken on the day of the survey. For an Excel Version of this sheet please email schools.auditsurveys@ealing.gov.uk Information Requested During Survey: School or Centre Suppliers: The name of the company that the school or centre engage only, not the sub-contractor. The survey will be pre-populated with suppliers from 2016 so you only need to note those which have changed. Support Surveyor: Mechanical: Legionella Testing: Drinking Water Quality Tests: Electrical: Lifts: Fire Alarm: Portable Fire Equipment: Intruder Alarm: CCTV Maintenance: Access Control: Grounds Maintenance: Cleaning: Catering: Playground Equipment: PE Equipment: Insurance: Audit_Survey_Template_17_C.xlsm Page 1 of 7 Pre-Survey

Compliance Section: Below are the questions asked in relation to compliance and best practice. Not all questions will be applicable for every site. Bold question numbers indicate a weighted question i.e. given a higher score than others. A typical example is question 1.02 which will be worth appr. 2% rather than the standard appr. 1%. Document dates will be requested where applicable so please have files/folders ready for the surveyor. Asbestos (for schools built during or after year 2000, only question 1.02 is applicable) 1.01 Does the Sch/Centre have a management (formerly type 2) asbestos survey? Yes, No or n/a Date 1.02 Does the Sch/Centre have an asbestos management plan including asbestos register? review 1.03 Is the management plan reviewed when new surveys or asbestos removals take place? review 1.04 Are the Sch/Centre aware that a 'refurbishment and demolition survey' should be carried out for some types of works? 1.05 Are all staff and contractors made aware of asbestos locations (via management plan)? 1.06 Does the Sch/Centre have a trained, nominated Responsible Person? If yes, who is it? 1.07 Has the Responsible Person received appropriate training and when? If Yes, who provided the training? Legionella Yes, No or n/a Date 2.01 Does the Sch/Centre have an up to date Legionella Risk Assessment? 2 years (review) 2.02 Is there a written scheme for preventing or controlling the risk and is it reviewed regularly? Does the Sch/Centre have a dedicated Water Safety or Legionella Logbook? Including precautions, water testing, temperature checks, any other recommended 2.03 actions and remedial works. 2.035 Have high priority recommendations in the Legionella Risk Assessment been completed or are planned? 2.04 Are records of thermostatic mixing valve (TMV) maintenance held on site? Essential for compliance. Usually removal of valves, cleaning and descaling. Does the Sch/Centre have records of monthly temperature readings for sentinel taps and sentinel TMVs? TMVs must have inlets and outlets temperature checked or 2.05 it is non-compliant. Either a representative number of outlets or all outlets should be measured. Monthly 2.06 Does the Sch/Centre have a trained, nominated Responsible Person? If so who is it? 2.07 Has the Responsible Person received appropriate training and when? If Yes, who provided the training? COSHH Yes, No or n/a Date 3.01 Does the Sch/Centre have a regularly reviewed COSHH risk assessment? review 3.02 Are substances suitably stored and labelled? e.g. Locked store room(s) with COSHH register/data sheets. 3.025 Are any hazardous substances used in lessons included in risk assessment(s)? 3.03 Has the Sch/Centre a nominated a trained, competent person(s) for COSHH? If so who is it? 3.04 Has the competent person(s) received appropriate training and when? If Yes, who provided the training? 5 years Audit_Survey_Template_17_C.xlsm Page 2 of 7 Pre-Survey

Roof Safety and Maintenance Yes, No or n/a Date 4.01 If the Sch/Centre has harness anchor bolts or roof fall arrest systems; are they maintained in accordance with manufacturer recommendations? 4.02 Does the Sch/Centre have records of general roof maintenance including checking of gutters, gullies rooflights etc? No set frequency. No set frequency 4.03 Does the Sch/Centre have a roof access procedure or relevant risk assessments and safe systems for working at height? review General Yes, No or n/a Date 5.01 Has the Sch/Centre recorded regular premises inspections to identify health & safety, security and maintenance issues? 5.02 Has the Sch/Centre recorded inspections of external areas e.g. playgrounds, playing fields, trees etc? Sometimes as part of 5.01 above. Does the Sch/Centre have records of inspection for play and gymnasium equipment? ( inspections by a specialist contractor (for some Ealing insured schools 5.03 the insurance dept can or do arrange). 5.04 Does the Sch/Centre have a system for organising/managing risk assessments including review dates? These are for school, teacher and site management activities. No set frequency 5.05 If the Sch/Centre has a kiln installed, do they have records of regular maintenance? Are records of safety isolation systems inspections/maintenance for science / home economic classroom / workshops held on site? E.G. gas isolation for labs or home 5.06 economics, workshop electric isolation 5.07 Are records of compressed air system inspections/maintenance held on site? e.g. Air tools, inflation tools, compressor inspections 5.08 Does the Sch/Centre regularly check operation of pull cord alarms? e.g. in disabled toilets No set frequency 5.09 Is appropriate hazard/advice signage in place? e.g. Hot water, drinking water, electricity, hazard signs, no entry. No set frequency 5.10 Is the Sch/Centre aware that they should inform Ealing Council if they plan to make alterations to council buildings? For community schools. Not a scoring question Accidents and First Aid Yes, No or n/a Date 6.01 Has a first aid risk assessment or equivalent been carried out and adequate training and provisions supplied? review 6.02 Are records of accidents and near misses kept and are staff aware of the recording procedures? Lifting Equipment Installation(s) Yes, No or n/a Date 7.01 If the Sch/Centre has operational lifts, dumb waiters or hoists are maintenance log card/book(s) on site and used correctly? 6 months 7.02 Are the lifts or hoists maintained in accordance with manufacturer recommendations and records kept? 6 months 7.03 Have any defects identified by the lift engineer, test certificate or thorough inspection report been corrected and documented? 7.04 If the Sch/Centre has any lifts or lifting equipment, is there a procedure and training for emergency situations such as the failure of the lift whilst occupied? Audit_Survey_Template_17_C.xlsm Page 3 of 7 Pre-Survey

Site Attendance/Visitors Yes, No or n/a Date 8.01 Does the Sch/Centre have a site attendance system or book for visitors and contractors? 8.02 Is it used correctly? (Did Surveyor sign in on the survey day?) This question cannot be updated in the update period. Site Specific Critical Incident Plan Yes, No or n/a Date 9.01 Does the Sch/Centre have a critical incident plan? (bomb scares, floods, security incidents etc) review 9.02 Has the plan been brought to the attention of all relevant employees? Fire Procedures Yes, No or n/a Date 10.01 Does the Sch/Centre have an annually reviewed Fire Risk Assessment (FRA)? review 10.02 Have the recommendations of the Fire Risk Assessment been completed and recorded? Does the Sch/Centre have site specific emergency (fire) evacuation plan (including personal emergency evacuation plans for individuals who may require additional 10.03 assistance)? review 10.04 Are evacuation procedures shared with contractors, supply teachers and other temporary staff prior to working on site? 10.05 Is appropriate advisory signage in place including emergency exit signs and assembly points? 10.06 Is there an up to date copy of the 6 monthly specialist contractor fire alarm maintenance records on site? BS5839-1:2013 6 monthly 10.07 Has the fire alarm been regularly tested (weekly) and records kept? BS5839-1:2013 Weekly 10.08 Are records of annual fire extinguisher maintenance held on site? Service sheets should identify which items were checked/faulty/replaced. Does the Sch/Centre have current records of inspections of fire doors (inspection of seals, door leaf condition, closing and release mechanisms, gaps between leaf 10.09 and frame)? BS9999 2008 6 monthly If the Sch/Centre has a sprinkler system installed, is the system maintained correctly and a log of maintenance kept? Also likely to be monthly, quarterly and annual 10.10 maintenance. BS EN 12845:2015 6 monthly If the Sch/Centre has a sprinkler system installed, does a suitably trained person complete and record the weekly checks? This may include water motor alarm test, 10.11 water and air pressure checks, pump starting test and diesel engine restarting test. BS EN 12845:2015 Weekly 10.12 Have fire/emergency evacuation drills taken place? Each term 10.13 Are a sufficient number of staff trained to deal with emergency evacuations and have roles been defined? i.e. Incident controllers, fire marshals. Security Systems Yes, No or n/a Date 11.01 Does the Sch/Centre have records of intruder alarm maintenance? 6 monthly 11.02 Does the Sch/Centre have records of access control system maintenance? ly 11.03 Does the Sch/Centre have records of CCTV systems maintenance?* ly 11.04 If the Sch/Centre has security panic alarms (hand held or push button), do they have records of testing? ly Audit_Survey_Template_17_C.xlsm Page 4 of 7 Pre-Survey

Emergency Lighting Yes, No or n/a Date Does the Sch/Centre have emergency lighting test records on site? (Monthly short duration test usually by the Sch/Centre or contractor, all luminaires.) BS5266-8 BS 12.01 Monthly EN 50172:2004 12.02 Have emergency lighting installations been service/maintained by a specialist contractor? Full duration, all luminaires. BS5266-8 BS EN 50172:2004 12.03 Does the Sch/Centre have an emergency lighting logbook? Including test records, faults, repairs and system information. BS5266-8 BS EN 50172:2004 Not a scoring question Heating, Hot Water Installations and Pressure Systems Yes, No or n/a Date 13.01 Does the Sch/Centre have records on site of main heating gas boiler(s) maintenance / servicing? 13.015 Does the servicing of gas boilers include safety checks of elements such as pipework, ventilation and gas tightness? Must be itemised on service sheets or separate paperwork. 13.02 Does the Sch/Centre have records of any repairs arising from the gas boiler testing and servicing? Including recommendations on any insurance inspection report. 13.03 Does the Sch/Centre have records of hot water cyclinder (calorifier) maintenance? 13.04 Are records of pressure vessel maintenance held on site (itemised on service sheets)? Gas Installations Yes, No or n/a Date Does the Sch/Centre have records of gas appliance inspection and/or maintenance for: 14.01 Standalone/domestic boilers and hot water heaters? 14.02 Design Technology, Science, Food Technology? 14.03 Catering? Gas safety inspection. 14.04 Caretaker's dwelling? gas safety certificate. Air Conditioning/Ventilation Systems Yes, No or n/a Date 15.01 Does the Sch/Centre have a record of regular inspections & maintenance for air conditioning units that comply with F-Gas regulations? 15.02 Have air conditioning systems with an output greater than 12kW been inspected by an energy assessor? 5 years 15.03 Are records of general ventilation maintenance (e.g. extract fans, air handling units) available? 15.04 Are records of kitchen extract maintenance held on site? To TR19 standard. Largely cleaning. CoSHH regs. Electrical Installations Yes, No or n/a Date 16.01 Does the Sch/Centre have an Electrical Installation Condition Report? * Please see the highlighted note below. No set frequency Have the recommendations of the above testing been completed or are they planned for the next available opportunity (in particular C1 and C2 items)? Records of 16.02 work. 16.03 In addition to formal periodic inspections, are routine checks carried out? (IET Guidance Note 3). Not a scoring question No set frequency Audit_Survey_Template_17_C.xlsm Page 5 of 7 Pre-Survey

Other Electrical Testing Yes, No or n/a Date 17.01 Does the Sch/Centre have a valid record of electrical appliance risk assessment and testing (including PAT)? or risk assessed 17.02 Does the Sch/Centre have a current record of annual lightning protection system testing? Insurance and Thorough Inspections Yes, No or n/a Date 18.X Does the Sch/Centre have correct information to access the HSB Haughton (insurance) document portal? 18.01 Does the Sch/Centre have insurance inspection records for boilers? Separate to maintenance inspections. May be required by insurance. Not statutory. Does the Sch/Centre have thorough inspection records for pressure systems? Separate to maintenance inspections. Sometimes arranged by insurance department. 18.02 PSSR regulations. 18.03 Does the Sch/Centre have a valid 'Written Scheme of Examination' for pressure systems? Sometimes arranged by insurance dept. PSSR regulations. If the Sch/Centre has lifts and/or lifting equipment and/or hoists FOR PEOPLE, have they had six monthly thorough inspections by a competent person? LOLER 18.04 regulations. Sometimes arranged by insurance dept but school likely to be responsible. 6 months If the Sch/Centre has lifting equipment for goods or items OTHER THAN people, have they had annual thorough inspections by a competent person? LOLER 18.05 regulations. Sometimes arranged by insurance dept but school likely to be responsible. 18.07 Are records of thorough inspections of fume cupboards on site? Separate to maintenance. CoSHH regulations. LEV inspection. 14 months Display Energy Certificates (not included in indicative compliance calculation) Yes, No or n/a Date 19.01 Is the Sch/Centre aware of their requirements for Display Energy Certificates? Energy Monitoring & Sustainability (not included in indicative compliance calculation) Yes, No or n/a Date 20.01 Does the Sch/Centre monitor energy usage (meter readings on a monthly basis, AMRs etc)? 20.02 Are there any sources of sustainable energy generation (i.e. Solar, Heat Pumps, Wind turbines etc.)? (If yes please enter details below including installation date) 20.03 Are there any energy saving initiatives currently in operation at the Sch/Centre? (If yes please enter details below) Has the Sch/Centre registered with any energy advice organisations e.g. Carbon Trust, Eco-Schools, Carbon Detectives? (if yes, please enter details in observations 20.04 below) Swimming/Hydrotherapy Pools Yes, No or n/a Date 21.01 If the Sch/Centre has a pool, do they have a documented pool risk assessment? 21.02 If the Sch/Centre has a pool, do they have documented pool specific emergency procedures? 21.03 Is there a named nominated competent person for dealing with the pool water treatment? If yes who is it? 21.04 Has the nominated person received appropriate training (and when)? If Yes, who provided the training? If specialist contractor this should be marked as n/a. 3 years 21.05 Is appropriate personal protective equipment (PPE) available for persons dosing the pool water? 21.06 Does the Sch/Centre document and undertake daily and weekly water quality testing? 21.07 Are there appropriately documented COSHH assessments for the chemicals used for treating the pool water? Audit_Survey_Template_17_C.xlsm Page 6 of 7 Pre-Survey

PFI schools and questions highlighted in green: Those items highlighted in green may be the responsibility of the school and should be obtained in advance from the school. Section 16 Note * It is not always possible for the audit surveyor to ascertain compliance in this section due to the risk based guidance available. The current guidance for periodic testing (IET Guidance Note 3) suggests that frequency of formal inspections should be based on available information and history of the installation. It is recommended that schools ask their contractor how their maintenance regime complies with Guidance Note 3; this should be requested in writing. Electrical installations should not be left without any attention for the periods of years that are normally allowed between formal inspections. Therefore, supplementary routine checks should be completed at appropriate frequencies. These checks need not being carried out by an electrically skilled person. School Notes: Audit_Survey_Template_17_C.xlsm Page 7 of 7 Pre-Survey