Operating Instructions

Similar documents
Operating Instructions

Operating Instructions

Operating Instructions

Pioneer-R16 Gas Monitor Operator s Manual

System 57. An advanced world of intelligent gas detection system management

EXTINGUISHING AGENT RELEASE MODULE

System 57. An advanced World of intelligent gas detection system management

Zareba Metro Gas Detector

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Application, Installation, Operation & Maintenance Manual

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Installation, Operating and Maintenance Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Zareba Unipoint controller

4 & 8-POINT ANNUNCIATORS Instruction Manual

CellarSafe. Carbon Dioxide and Oxygen Safety Monitor

MODEL 5100 VOTING LOGIC MODULE

LASER ASPIRATED SMOKE DETECTOR

Excellence in Level Measurement

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

Flostop TS D7E and A8E. Operation Manual

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

User Operation Manual

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

RE-PR3-E-27 3-Phase Panel Mount 27kW

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

LASER ASPIRATED SMOKE DETECTOR

Instruction Manual SCD24. Read this document prior to installation. Contents

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

4100U City and Relay Cards Installation Instructions

Flopurge TS. Operation Manual

Technical Handbook. Sieger Apex

Operating Instructions

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Zareba Sensepoint Pro

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

RMS/RPX Reader. User Manual

RAM3 Remote Alarm Module

Dry Contact Probe DCP (#30008)

SFC-200 SERIES LED FIRE ALARM PANEL

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Water Detection Controllers

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

TOC-20 SERIES. Refrigerant Gas Monitor. Installation and Operation Manual Version 3 IGD OLIVER CH4 NO. Document Ref: T20-V3

ORION Mini-Rep INSTALLATION MANUAL

Operating Instructions

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

FEC400 Series. Installation Manual

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

ESP TECHNOLOGIES LIMITED

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Vocia VACIE. Reference Guide

BX444-Mc Gas Detector

Operating Instructions and Maintenance Manual

ADE Gen4. Speech Dialler Engineering Information. Description. Features

VACIE REFERENCE GUIDE REVISION 1.2.6

MIC-WKT and MIC-WKT-IR Installation Manual

Ax60+ Multi-Gas, Quick Connect Option

SmartTerminal AS7240. Installation and Operation Guide MAN2990-1

Installation and user manual for the BiWire / Conventional Repeater Panel

SECURIT 700L PLUS ENGINEERING MANUAL

ID2000. operating manual

SmartTerminal. Installation Commissioning & Operation. Our aim is to provide Consistently Excellent Service in the eyes of our customers MAN1536-6

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

21-light Remote Annunciator. Owner s Manual

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Door Release Power Supply

Design Manual Installation Operation Maintenance

The Remote alarm Panel, TYPE RAPv2

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

20 Light Remote Annunciator

SYSTEM 5000 USER MANUAL

Interface Modules for SENTRI

MODEL WIND TRACKER

Intelligent Security & Fire Ltd

Dough Retarder Prover. Service Manual

Intelligent Security & Fire Ltd

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

GS100M Gas Detection Controller

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Original operating instructions Safety switch with guard locking AC901S AC902S

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Transcription:

Operating Instructions System 57 Module Kit (05701-A-0309) Alarm Update Panel (05701-A-0339)

Helping to make a safer world Ensure that you read and understand these instructions BEFORE operating the equipment. Please pay particular attention to the Safety Warnings. WARNINGS The items of equipment covered by this manual are: 1. Not designed or certified for use in hazardous areas. 2. Designed for indoor use only. 3. Not to be exposed to rain or moisture. CAUTIONS 1. Use only approved parts and accessories with this control system. 2. To maintain safety standards, regular maintenance, calibration and operation of this control system by qualified personnel is essential. IMPORTANT NOTICES 1. Zellweger Analytics Limited can take no responsibility for installation and/or use of its equipment if this is not done in accordance with the appropriate issue and/or amendment of the manual. 2. The user of this manual should ensure that it is appropriate in all details to the exact equipment to be installed and/or operated. If in doubt, the user should contact Zellweger Analytics Limited for advice. Zellweger Analytics Limited reserve the right to change or revise the information supplied in this document without notice and without obligation to notify any person or organisation of such revision or change. If further details are required which do not appear in this manual, contact Zellweger Analytics Limited or one of their agents. 2

GLOSSARY A1 - First Level Gas Alarm. Lower or pre-warning alarm. A2 - Second Level Gas Alarm. Intermediate warning alarm. A3 - Third Level Gas Alarm. Upper warning alarm. LED - Light Emitting Diode. * LTEL - Long Term Exposure Limit. (8 hours TWA value). RFI - Radio Frequency Interference RH - Relative Humidity. * STEL - Short Term Exposure Limit. (10 minutes TWA value). * TWA - Time Weighted Average. * Refer to the appropriate National Standards Authority for details. In the UK this detail is in the Guidance Note EH 40/89 from the Health and Safety Executive on Occupational Exposure Limits 1989. HELP US TO HELP YOU Every effort has been made to ensure the accuracy in the contents of our documents, however, Zellweger Analytics Limited can assume no responsibility for any errors or omissions in our documents or their consequences. Zellweger Analytics Limited would greatly appreciate being informed of any errors or omissions that may be found in the contents of any of our documents and to this end we include the form opposite for you to photocopy, complete and return to us so that we may take the appropriate action. 3

HELP US TO HELP YOU To: Marketing Communications, Zellweger Analytics Limited, Hatch Pond House, 4 Stinsford Road, Nuffield Estate, POOLE. Dorset. BH17 0RZ. United Kingdom. From: Address: Tel : +44 (0) 1202 676161 Fax : +44 (0) 1202 678011 email : markcom@zellwegeranalytics.co.uk Tel : Fax : email : I suggest the following corrections/changes be made to Chapter... Section... Marked up copies attached (as appropriate): Please inform me of the outcome of this change: Yes / No Yes / No For Marketing Communications, Zellweger Analytics Limited: Actioned By: Response: Date: Date: 4

CONTENTS Section Page GLOSSARY 3 1. INTRODUCTION 7 1.1 Principal Features 7 1.2 Construction 8 2. CONTROLS AND FACILITIES 12 2.1 Introduction 12 2.2 Module Facilities 12 2.2.1 Update Outputs 12 2.2.2 Control Inputs 14 2.3 Panel 14 2.3.1 Switch Inputs 14 2.3.2 Audible and Visual Outputs 16 3. INSTALLATION INSTRUCTIONS 17 3.1 Introduction 17 3.2 Unpacking 20 3.3 Installing the Kit 20 3.4 Installing the Panel 22 3.5 System Connections 23 3.5.1 General 23 3.5.2 Cabling 23 3.5.3 Update 1 - Open Collector Transistor Output 26 3.5.4 Update 2 - Relay Output 26 3.5.5 Update Accept Input 27 3.5.6 Master Alarm Reset Input 28 5

CONTENTS Section Page 4. CONFIGURATING THE UPDATE FUNCTION 30 4.1 General 30 4.2 Update Output Configuration: 30 4.3 Control Input Configuration 30 5. COMMISSIONING AND MAINTENANCE INSTRUCTIONS 31 5.1 Start Up Procedure 31 5.2 Maintenance 32 5.3 Fault Finding 32 6. OPERATING INSTRUCTIONS 34 7. SPECIFICATION 35 7.1 Environmental 35 7.2 EMC/RFI Conformity 35 7.3 Module 35 7.4 Panel 36 FIGURES 1. Module 9 2. Front View of Alarm Update Panel. 10 3. Overview 11 4. Alarm Update Sequence 15 5. System 57- Engineering Card Mark I 18 5. System 57- Engineering Card Mark Il 19 7. Panel Connections 22 8. Front Access Connections for DC Input Card and Option Module 24 9. Rear Access Connections for DC Input Card and Option Module 25 10. Wiring Example - Update 1 Driving a Lamp 26 11. Wiring Example - Update 2 Operating an External a Sounder 27 12. Update Accept Remote Switch Connection 28 13. Master Alarm Reset Remote Switch Connection 29 6

1. INTRODUCTION 1.1 PRINCIPAL FEATURES The System 57 option provides an extra facility for common alarm outputs. This facility provides an indication when a new alarm occurs on any channel within the rack, even if a previous alarm condition already exists. This is useful in systems configured with only a master or group/zone relays where, once an initial alarm has activated the relay outputs, the occurrence of subsequent alarms will not cause further relay outputs. The principal features of the update facility are: Easily fitted to the Engineering Card. Simple field connections via the DC Input Card terminal block for wire up to 2.5mm² (14 AWG). Provides update output based on the Fault, Inhibit, A1, A2, A3, STEL, LTEL and Rate alarms from all cards in the rack. Compatible with the 5701 and 5704 Control Cards. Single pole relay output. Open collector transistor output with thermal protection. Alarm Update Accept input. Master Alarm Reset input. Easily configured using the Engineering Interface Software The facility can be enhanced by adding the optional Panel. The rack mounted 1" wide panel provides one audible and one visual alarm output, and two push-button switches. This provides convenient access to the update facilities without the need for external wiring. 7

1. INTRODUCTION The principal features of the update panel are: Neat 1" wide integrated panel design. Large high intensity led lamp for visual indication. Sounder for audible indication. Push-button for Master Alarm Reset. Push-button for Alarm Update Accept. Existing relay and transistor outputs, and remote inputs can still be used. 1.2 CONSTRUCTION The System 57 facility is available pre-installed in new systems or as a kit for retrofitting into existing systems. The kit consists of a small pcb module and an integrated circuit that are plugged into the expansion sockets provided on the Engineering Card. Connections for the update outputs and remote inputs are made via the six way expansion terminal block that is located on the DC Input Card. An enhanced version of the Engineering Card software must be installed in order to provide the master alarm update functions. The new software is fully compatible with the original Engineering Card software and is provided in the kit in the form of a plug-in integrated circuit. The layout of the Module is shown in Figure 1. The Panel is a 1" wide 3U high panel with a flying lead that plugs through a slot in the Engineering Card onto the Module. The panel occupies a single slot within the rack immediately adjacent to the Engineering Card. The layout of the Panel is shown in Figure 2 8

1. INTRODUCTION Update 2 Mode Control LK2 LK2 1 2 3 Relay Contacts Normally Open or 1 2 3 Relay Contacts Normally Closed Figure 1 Module 9

1. INTRODUCTION Visual Alarm Sounder Figure 2 Front View of Alarm Update Panel. 10

1. INTRODUCTION Front Access 8 or 16-Way Rack optional Alarm Update Panel Engineering Card Mk l or ll* *Mkll required with Update Panel DC Input Card Master Alarm Update Module Rear Access 8 or 16-Way Rack Figure 3 Overview 11

2. CONTROLS AND FACILITIES 2.1 INTRODUCTION The 5701 and 5704 Control Systems provide a complete solution for the operational and engineering requirements of a multi-channel gas detection system. Each control card within the rack system provides sensor drive, signal acquisition, gas concentration display and comprehensive alarm facilities for one or more gas sensors. The facility extends the capability of the control system by monitoring the alarm status of every gas sensor connected to the rack in order to provide additional alarm outputs. The additional outputs are activated whenever a new alarm occurs anywhere within the rack, irrespective of any preexisting alarm conditions. These outputs are ideal for controlling audible and visual indicators to draw the operators attention to new gas alarm conditions and to provide a reminder of the continued presence of old alarms. Two remote type control inputs are provided. One control input allows active alarm update conditions to be acknowledged and the other control input provides a means of performing a simultaneous alarm reset on all channels in the rack. 2.2 MASTER ALARM UPDATE MODULE FACILITIES 2.2.1 Update Outputs The Module provides two update outputs designated Update 1 and Update 2. The alarm events that are monitored by the update facility to control the outputs are Fault, Inhibit, A1, A2, A3, STEL, LTEL and Rate using information gathered from all cards and/or channels in the rack. Each of the update outputs can be individually configured to operate on one, a subset or all of the alarm events. 12

2. CONTROLS AND FACILITIES The operating mode of each output is also configurable for the change in actuation that will result when new alarm events occur, existing alarm events clear or when the update is accepted. The options available in these cases include pulsing, steady, off and no change. Each output has different electrical characteristics, as follows: a. Update 1 This is an open collector transistor type output and is useful for switching low voltage low power devices. eg. Lamps. When the Panel is fitted, this output also controls the update panel lamp. The default configuration for this output is: a. pulsing whenever a new alarm occurs, becoming b. steady when accepted, if the alarm is still present, or b. Update 2: off when accepted, if the alarm has cleared. This is a single throw relay output that is set by a hardware link for normally open or closed operation. This is useful for switching low voltage medium power devices. eg. Sounders. The default configuration for this output is a steady on whenever a new alarm occurs, switching to off when accepted. 13

2. CONTROLS AND FACILITIES 2.2.2 Control Inputs The Module provides two control inputs. Each input can be configured for active high (default) or active low operation. The inputs are as follows: a. Alarm Update Accept: This input is associated with the alarm update facility and provides for a remote switch to acknowledge the active alarms. b. Master Alarm Reset: This is a remote switch input that provides a facility to allow a general reset of all alarm channels in the rack. Operating the remote reset will clear all non-active latched alarms and faults as if all RESET/SELECT push-buttons on all the control card front panels had been pressed simultaneously. A master alarm update if active will also be accepted. 2.3 MASTER ALARM UPDATE PANEL 2.3.1 Switch Inputs The Panel provides two push-button switches, conveniently located on the front panel of the rack, to operate the two control inputs of the Master Alarm Update Module. These switches are: a. Accept Push-button This button is associated with the alarm update facility and when pressed will acknowledge active alarms. 14

2. CONTROLS AND FACILITIES Condition Push-button Sensor Lamp Sounder Normal condition Sensor 1 in alarm Alarm accept Accept Sensor 1 still in alarm Sensor 2 in alarm Alarm accept Accept Both sensors still in alarm Alarm condition cleared Alarm reset Reset Normal condition Key: Push-button: operated. Sensor: No alarm In alarm condition. condition. Lamp: Off Steady on Flashing Sounder: Off Steady on Figure 4 Alarm Update Sequence 15

2. CONTROLS AND FACILITIES b. Reset Push-button This button provides a general reset of all alarm channels in the rack. When pressed the reset will clear all non-active latched alarms and faults as if all RESET/SELECT push-buttons on all the control card front panels had been pressed simultaneously. A master alarm update if active will also be accepted. 2.3.2 Audible and Visual Outputs In order to attract the operators' attention when alarm events occur within the gas monitoring system, the Master Alarm Update Panel provides two conveniently located alarm outputs on the front panel of the rack. These are: a. Audible Indicator The audible indication is provided by a loud high pitched sounder which is controlled by the Update 3 alarm function. It can be configured in exactly the same way as the Update 1 and 2 functions. b. Visual Indicator The visual indication is provided by a large bright led lamp. The lamp is controlled by the Update 1 function which also controls the open collector transistor output. 16

3. INSTALLATION INSTRUCTIONS WARNING The Engineering Card and Upgrade Kit are susceptible to damage by static electricity and therefore the appropriate precautions should be taken. 3.1 INTRODUCTION There are two versions of the Engineering Card, Mark l and Mark ll. With the Engineering Card removed from the rack the differences between the two types of Engineering Card can be identified as follows: a. Mark I hardware can be identified by the presence of only one 28 pin DIL IC socket on the card pcb. See Figure 5. b. Mark II hardware can be identified by the presence of two 28 pin DIL IC sockets and a rectangular cutout near the centre of the card pcb. See Figure 6. Both the Mark l and Mark ll versions of the Engineering Card can be fitted with the Kit, for which the installation procedure is identical. The Panel can however only be fitted to the Mark ll Engineering Card. A summary of the installation procedure is shown below: a. Unpack and check equipment. b. Remove the Engineering Card from the rack. c. Install the Software Expansion EPROM. d. Install the Module. e. Install the Panel (if required). f. Wire the DC Input Card terminal blocks. g. Configure and Commission. 17

3. INSTALLATION INSTRUCTIONS LK1 3 2 1 C10 D6 XL1 IC4 IC5 IC3 IC9 IC10 IC11 1 LK1 3 2 1 XL2 IC7 C15 C17 L1 TR1 C1 FS1 SK2 J3 D5 D2 C6 C2 IC1 16 1 J1 C8 C4 L2 IC2 SK1 IC6 PL1 IC8 D8 D7 J2 1 Insert IC2 EPROM notch downwards When inserting the Master Alarm Update Module, ensure the correct alignment and orientation. Figure 5 System 57- Engineering Card Mark I 18

3. INSTALLATION INSTRUCTIONS LK1 3 2 1 C10 D6 XL1 IC4 IC5 IC3 IC9 IC10 IC11 1 LK1 3 2 1 XL2 D4 C15 SK2 IC7 C17 L1 TR1 C1 FS1 J3 D5 D2 D1 D11 C2 C6 IC1 16 1 J1 IC13 C8 L2 C4 IC2 IC12 SK1 IC6 PL1 IC8 D8 D7 J2 1 Insert IC2 EPROM notch downwards When inserting the Master Alarm Update Module, ensure the correct alignment and orientation. Figure 6 System 57- Engineering Card Mark Il 19

3. INSTALLATION INSTRUCTIONS After installation is complete perform the commissioning procedures outlined in Section 5. The following sections of this section provide a detailed explanation of the installation operations. 3.2 UNPACKING On receipt carefully unpack the equipment observing any instructions printed on or contained in the packaging. Check the contents for transit damage and ensure that the following items are present: For the Kit: a. Module (Part Number 05701-A- 0286). b. Engineering Card Expansion Option EPROM integrated circuit (Part Number 05701-A-0385). c. This User Manual (Part Number 05701-A-5008). For the optional Panel: d. Panel Assembly (Part Number 05701-A-0339). 3.3 INSTALLING THE MASTER ALARM UPDATE KIT The following procedure applies to both the Mark l and ll versions of the Engineering Card. To install the Kit, proceed as follows: (1) Isolate the System 57 Rack from all power sources. (2) Unscrew the two front panel screws that retain the Engineering Card and, using the extraction tool supplied with the system, pull the Engineering Card from the rack. 20

3. INSTALLATION INSTRUCTIONS WARNING The Upgrade EPROM can be permanently damaged by incorrect insertion. (3) Insert the Software Upgrade EPROM integrated circuit (Part Number 05701-A-0385) into socket IC2 on the Engineering Card. Ensure that pin 1 of the IC is aligned correctly with pin 1 of the socket and that all pins are properly inserted into the socket. (4) Using small pliers, or an electrical screwdriver, gently remove the Engineering Card shorting link LK1 from pins 2 and 3 and replace to short pins 1 and 2 (see Figure 5 and 6). (5) By default the Update 2 relay output is set for a normally open contact which closes when an update condition is detected. If the Update 2 relay output is required to operate as a normally closed contact which opens when an update condition is detected, LK2 on the Module must be reset as follows: 1. Using small pliers or an electrical screwdriver, gently remove shorting link LK2 on the Master Alarm Update Module. 2. Replace LK2 to short pins 1 and 2 (see Figure 1). (6) Insert the Module into socket headers J1 and J2 on the Engineering Card, ensuring that pin 1 of the module pin headers is correctly aligned with pin 1 of the Engineering Card socket headers. (7) If it is not required to fit the Panel, re-insert the Engineering Card back into the rack, tighten the two front panel securing screws and go to the Section 3.5. 21

3. INSTALLATION INSTRUCTIONS 3.4 INSTALLING THE MASTER ALARM UPDATE PANEL The Panel can only be fitted to the Mark 2 Engineering Card. The Module Kit should be installed prior to the Panel. The installation procedure is as follows: (1) Isolate the System 57 Rack from all power sources. (2) Unscrew the two front panel screws that retain the Engineering Card and, using the extraction tool supplied with the system, pull the Engineering Card from the rack. (3) Insert the flying header socket, that is attached to the Panel, through the slot located on the back of the Engineering Card and plug the header onto the pins of the Module. Ensure that pin 1 of the flying lead, marked by the coloured stripe on one edge of the ribbon cable, corresponds to pin 1 on the Master Alarm Update Module and there are no twists in the cable. See Figure 7. Master Alarm Update Panel Coloured Strip 1 13 Back of Engineering Card Mark ll Figure 7 Panel Connections 22

3. INSTALLATION INSTRUCTIONS (4) Remove the front panel blanking panel (if fitted) from the slot immediately to the left of the Engineering Card. (4) Re-insert the Engineering Card into the most right hand slot in the rack and insert the Update Panel into the slot immediately to the left of the Engineering Card. (6) Tighten the two front panel screws that retain the Engineering Card and the two screws that retain the Update Panel. 3.5 SYSTEM CONNECTIONS 3.5.1 General The field connections to the Module are made via the auxiliary terminal block (TB2) on the DC Input Card. The terminal block is a two part type to aid the connection of field cables without removing the DC Input Card. The DC Input card terminal connections are shown in Figure 8 and 9. 3.5.2 Cabling The field terminals of the DC Input Card accept single or multi-stranded wire up to 2.5mm² (14 AWG). Cables should be routed carefully to avoid physical and environmental hazards such as mechanical stress and high temperatures. In order to ensure correct operation and to meet European Standards for RFI and EMC it is recommended that all field cables are screened. The cable screen should be connected to either the ground terminal of the DC Input Card, the cabinet using a suitable metal cable gland or other suitable instrument earth point. 23

3. INSTALLATION INSTRUCTIONS TB2 1 Update 1 2 Update 2 (NO or NC**) 3 Update 2 (COM 4 Update Accept 5 Master Alarm Reset 6 Ground TB1 1 Ground 2 Ground 3 0V Out (Fused) 4 +24V Out (Fused) 5 0V In (AUX 2) or 0V Out (AUX 1) 6 +24V In (AUX 2*) or +24V Out (AUX 1) 7 0V In (AUX 1) 8 +24V In (AUX 1) 9 0V In (PSU 2) or 0V Out (PSU 1) 10 +24V In (PSU 2*) or +24V Out (PSU 1) 11 0V In (PSU 1) 12 +24V In (PSU 1) Connections for Master Alarm Update Module * PSU 1 and PSU 2 (and AUX 1 and AUX 2) must be compatible with parallel connection. **Normally open (NO) or normally closed (NC) operation is link selectable. Figure 8 Front Access Connections for DC Input Card and Option Module 24

3. INSTALLATION INSTRUCTIONS TB1 12 +24V In (PSU 1) 11 0V In (PSU 1) 10 +24V In (PSU 2*) or +24V Out (PSU 1) 9 0V In (PSU 2) or 0V Out (PSU 1) 8 +24V In (AUX 1) 7 0V In (AUX 1) 6 +24V In (AUX 2*) or +24V Out (AUX 1) 5 0V In (AUX 2) or 0V Out (AUX 1) 4 +24V Out (Fused) 3 0V Out (Fused) 2 Ground 1 Ground TB2 6 Ground 5 Master Alarm Reset 4 Update Accept 3 Update 2 (COM 2 Update 2 (NO or NC**) 1 Update 1 Connections for Master Alarm Update Module * PSU 1 and PSU 2 (and AUX 1 and AUX 2) must be compatible with parallel connection. **Normally open (NO) or normally closed (NC) operation is link selectable. Figure 9 Rear Access Connections for DC Input Card and Option Module 25

3. INSTALLATION INSTRUCTIONS 3.5.3 Update 1 - Open Collector Transistor Output CAUTION The Update 1 output may be permanently damaged if connected to voltages in excess of 40V. The Update 1 open collector output is suitable for switching low voltage low power devices. eg. Lamps, relays etc. When an update condition is detected the transistor is switched on and current can flow between the Update 1 terminal and the system dc power supply 0V. The transistor outputs is rated at 40V 100mA maximum. Figure 10 shows a wiring example of Update 1 driving a lamp. +24V (From System 57 PSU) TB2-1 Update 1 Lamp Figure 10 Wiring Example - Update 1 Driving a Lamp 3.5.4 Update 2 - Relay Output WARNING For safety reasons the Update 2 relay output must not be connected to voltages in excess of 40V. The Update 2 relay output is suitable for switching low voltage medium power devices. eg. Sounders etc. or devices where electrical isolation (not exceeding 50V) is required. When an update condition is detected the relay is energised. The output is link selectable between the normally open and closed contacts of the relay. The relay contacts are rated a 40V 2A maximum. 26

3. INSTALLATION INSTRUCTIONS Figure 11 shows a wiring example of Update 2 being used, in the normally open configuration, to operate an external sounder. +24V TB2-2 Update 2 (NO) Sounder TB2-3 Update 2 (COM) 0V Figure 11 Wiring Example - Update 2 Operating an External Sounder 3.5.5 Update Accept Input CAUTION Connecting voltages in excess of 40V to the remote input may cause permanent damage to the Master Alarm Update Module. The Accept input can be configured for active high (default) or active low operation. Check the configuration sheet supplied with the system to determine the factory configured operating mode. The operating mode can be reconfigured easily using a computer attached to the Engineering Port. Contact Zellweger Analytics or your local agent for more information. The switching level of the remote input is approximately +2V with respect to the dc supply 0V. The input requires less than 5mA drive current and irrespective of configuration is internally pulled down to 0V. Figure 12 shows the connections to the Accept control. 27

3. INSTALLATION INSTRUCTIONS +24V (From System 57 PSU) TB2-4 Update Accept Switch Figure 12 Update Accept Remote Switch Connection An active high remote input may be left unconnected or connected to +24V via a normally open contact. The remote input will operate whenever the contact closes. An active low remote input may be connected to +24V via a normally closed contact. The remote input will operate whenever the contact opens. Note: 1. Active low operation can not be used if the Update Panel is fitted. 2. Active low inputs must not be left unconnected. 3.5.6 Master Alarm Reset Input CAUTION Connecting voltages in excess of 40V to the remote input may cause permanent damage to the Master Alarm Update Module. The Master Alarm Reset input can be configured for active high (default) or active low operation. Check the configuration sheet supplied with the system to determine the factory configured operating mode. The operating mode can be reconfigured easily using a computer attached to the Engineering Port. Contact Zellweger Analytics or your local agent for more information. 28

3. INSTALLATION INSTRUCTIONS The switching level of the remote input is approximately +2V with respect to the dc supply 0V. The input requires less than 5mA drive current and irrespective of configuration is internally pulled down to 0V. Figure 13 shows the connections to the Master Alarm Update Reset control. +24V (From System 57 PSU) TB2-5 Master Alarm Reset Switch Figure 13 Master Alarm Reset Remote Switch Connection An active high remote input may be left unconnected or can be connected to +24V via a normally open contact. The remote input will operate whenever the contact closes. An active low remote inputs may be connected to +24V via a normally closed contact. The remote input will operate whenever the contact opens. Note: 1. Active low operation can not be used if the Update Panel is fitted. 2. Active low inputs must not be left unconnected. 29

4. CONFIGURING THE UPDATE FUNCTION 4.1 GENERAL The Facility is configured using the Engineering Interface Software (EIS) tool supplied as part of the Engineering Interface Kit. Refer to the user manual supplied with the EIS for detailed instructions on using the software to change the configuration of a rack. The following sections give a brief summary of the configuration options available for the Facility. 4.2 UPDATE OUTPUT CONFIGURATION: The alarm events monitored by the update facility to control the Update 1, Update 2 and Update 3 outputs are Fault, Inhibit, A1, A2, A3, STEL, LTEL and Rate, using information gathered from all cards and/or channels in the rack. Each of the update outputs can be individually configured to operate on one, a subset or all of the alarm events. The operating mode of each output is also configurable for the change in actuation that will result when new alarm events occur, existing alarm events clear or when the update is accepted. The options available in these cases include pulsing, steady, off and no change. The pulse rate is also configurable. 4.3 CONTROL INPUT CONFIGURATION The control inputs Master Alarm Reset and Alarm Update Accept, can be configured for active high (default) or active low operation. 30

5. COMMISSIONING AND MAINTENANCE INSTRUCTIONS IMPORTANT For completely new System 57 installations that have not previously been tested, the commissioning procedure outlined in the Control System User Manual must be performed fully before attempting to commission the Facility. 5.1 START UP PROCEDURE A detailed check of the system wiring should be carried out prior to this start-up procedure. Start-up the system as follows: (1) Ensure that the system power supply is off. (2) Reconnect the power supply to the rack and verify that both Engineering Card front panel LED s flash for a short period after which the green POWER ON indicator illuminates continuously. (3) Check that the outputs are in the non alarm condition. (4) Check that after the pre-defined start up inhibit period, typically 30 seconds, the INHIBIT LED on each control card is extinguished, and that there are no alarms or faults signalled on any channel. (5) Use the alarm test mode of any one of the control cards in the rack to simulate an alarm condition. (Refer to the Engineer s alarm relay test procedure in the Control System User Manual for more details). (6) Check that the outputs are actuated in the appropriate state. eg. Pulsing or steady on. (7) Activate the Alarm Accept Input and check that the outputs change to the required actuation state. eg. Steady or off. 31

5. COMMISSIONING AND MAINTENANCE INSTRUCTIONS (8) Repeat steps 5, 6 and 7 to simulate additional alarms encompassing all levels that are being monitored. (9) Clear the simulated alarm set up in step 5. (10) Activate the Master Reset Input and check that the outputs switch off. 5.2 MAINTENANCE The Facility should be tested at regular intervals as outlined in the maintenance procedure given in the Control System User Manual. 5.3 FAULT FINDING The following table identifies common problems and suggests appropriate actions. Description of Fault General Failure. Suggested Action Check correct orientation and location of update module on Engineering Card. Check the Enhanced Software EPROM is fitted correctly on Engineering Card and that link LK1 is set accordingly. Check update module configuration using Engineering Interface Software. Check update module config- uration using Engineering Interface Software. Check wiring to TB2-1. Update Output(s) operate in wrong mode. Update 1 Output does not operate. 32

5. COMMISSIONING AND MAINTENANCE INSTRUCTIONS Description of Fault Update 2 Output does not operate. Update 2 Output relay contacts operate incorrectly. Suggested Action Check wiring to TB2-2 and TB2-3. Check link LK2 setting on the Module. Control Inputs do not operate. Update Panel does not operate. Update Panel audible output does not operate. Check wiring to TB2-4 and TB2-5. Check input mode configuration using Engineering Interface Software. Check correct orientation and location of update panel header connection to update module. Check update panel configuration using Engineering Interface Software. 33

6. OPERATING INSTRUCTIONS The most common use for the Facility is to draw the operators attention to new gas alarm conditions within a System 57 rack and to provide a reminder of the continued presence of old alarms. Generally the update outputs are be connected to give both audible and visual indications whenever a new alarm condition occurs in the rack. After the update alarm has activated the operator can use the Alarm Update Accept input to switch off the audible sounder, however, the visual indication will remain switched on if a gas alarm is still present. Whenever an update alarm occurs, the operator should examine the alarm status on every card in the rack to assess the severity of the situation and to determine what action if any should be taken. If another alarm occurs a new update condition will be signalled, even if previous alarms have not cleared. The Master Alarm Reset input can be used as a convenient way to reset of all alarm channels in the rack. Operating the Master Alarm Reset will clear, provided the condition is no longer present, all latched alarms, faults, errors and warning messages as if all RESET/SELECT pushbuttons on all card front panels had been pressed simultaneously. A master alarm update, if active, will also be accepted. 34

7. SPECIFICATION 7.1 ENVIRONMENTAL Operating Temperature: Storage Temperature: Humidity: -5 C to +55 C. -25 C to +55 C. 0 to 90% RH. (Non condensing). 7.2 EMC/RFI CONFORMITY EN50081 Part 1 & Part 2 EN50082 Part 1 & Part 2 EMC/RFI (Generic Emission). EMC/RFI (Generic Immunity). Note: Systems with field connections made via unscreened cable comply with EN50082 Part 1 only. 7.3 MASTER ALARM UPDATE MODULE Power Supply: Power Consumption: Powered from Engineering Card. 0.25W (maximum). Weight: 25g. Field Terminals: 2.5mm² (14 AWG) located on DC Input Card. Transistor Output: Update 1. Modes: Pulse On/Off Time: Maximum Input Voltage: Maximum Input Current: Steady or Pulsed (default). Adjustable from 0 to 25.5 seconds in 0.1 second increments. 40V dc. 100mA. Saturation Voltage (V CE ): 3V (maximum). 35

7. SPECIFICATION Protection: Thermal over-current shutdown. Relay Output: Update 2. Modes: Pulse On/Off Time: Contact Type: Relay Contact Rating: Steady (default) or Pulsed. Adjustable from 0 to 25.5 seconds in 0.1 second increments. Single pole link selectable for normally open or closed operation. 2A at 40V dc (non-inductive). Isolation: 50V relative to system 0V. Remote Inputs: Master Alarm Reset and Update Alarm Accept. Input Threshold: 2V. Maximum Input Voltage: Maximum Input Current: 40V dc. 5mA. 7.4 MASTER ALARM UPDATE PANEL Power Supply: Power Consumption: Powered from Engineering Card. 0.2W (maximum). Weight: 35g. Dimensions: Height: Width: Depth: 132mm. 25mm. 30mm. 36

7. SPECIFICATION Switch Inputs: Contact Type: Visible Output: Master Reset and Update Alarm Accept. Push-button momentary action. Update 1 (shared with Update Module). Modes: Same as Update 1. Type: 8mm high intensity red LED lamp. Audible Output: Update 3. Modes: Pulse On/Off Time: Type: Steady (default) or Pulsed. Adjustable from 0 to 25.5 seconds in 0.1 second increments. Piezo electric buzzer. Nominal Frequency: 2khz Sound Level: 85dB at 100mm. 37

USER NOTES 38

USER NOTES 39

Find out more www.honeywellanalytics.com Customer business centre Europe and the rest of the world Honeywell Analytics AG Wilstrasse 11-U11 CH-8610 Uster Switzerland Tel: +41 (0)1 943 4300 Fax: +41 (0)1 943 4398 sales@honeywellanalytics.co.uk Customer business center Americas Honeywell Analytics Inc. 400 Sawgrass Corporate Pkwy Suite 100 Sunrise, FL 33325 USA Tel: +1 954 514 2700 Toll free: +1 800 538 0363 Fax: +1 954 514 2784 sales@honeywellanalytics.com www.honeywell.com Issue 1 12/2005 H_MAN0505.PM6_V1 2005 Honeywell Analytics?????