ecodry K-MT 1-8 Efficient compressed air adsorption dryers Short Description K-MT 1-8 heatless adsorption dryers are designed to dry industrial compressed air reliably and efficiently down to a pressure dew point of -70 C. The units are constructed in a compact manner and designed to be free-standing or wall mounted. They are equipped with built-on pre- and after filtration and are sized for volumetric flows of up to 86 m3/h (suction capacity of the compressor referring to a compression of 7 bar e ). Compressed air first enters the validated GL pre-filter. Continuing on, the air flows into one of two twin-vessels (twin-chamber aluminium profiles); both filled with molecular sieve - a renowned drying-agent, where the air is dried. During the drying process, the second chamber undergoes regeneration: At the start of the drying-cycle, this chamber is open to atmosphere and a small proportion of dried compressed air passes through the adsorption bed, transporting the humidity out. When this procedure is complete, the chamber is re-pressurised in readiness to repeat the drying procedure. Continuous, uninterrupted operation is maintained utilising socalled pressure-swing technology together with individually operated main- and exhaust valves. Dry compressed air finally exits via a validated GL after-filter preventing the migration of particles into the downstream compressed air network. The K-MT 1-8 adsorption dryer series operates a fixed, timed, changeovercycle between the two dryer chambers. Where the application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available as an option: In such an operating mode, the changeover-cycle between chambers only takes place when required, and is dependent on the required dew point being achieved: Only on reaching this adjustable set-point does changeover to the pre-dried vessel occur. This feature enables the drying phase to be lengthened and thus avoids the unnecessary use of purge air for regeneration. Compressed air can be selectively dried to meet a dew point of -25 C up to -70 C. Scope of supply: Adsorption dryer - ready for installation, including GL pre- and after filters; available with dew point dependent switching (DDS) as an option.
ecodry K-MT 1-8 adsorption dryer series Ordering and performance data Model Order No. Volumetric flow 1) in m 3 /h pipe size 2) Pre-filter After-filter pressure in bar e temp. C K-MT 1 K1/16D2-G230M 8 1/4 GL2XL GL2ZLH 16 50 K-MT 2 K2/16D2-G230M 15 1/4 GL2XL GL2ZLH 16 50 K-MT 3 K3/16D2-G230M 25 1/4 GL2XL GL2ZLH 16 50 K-MT 4 K4/16D2-G230M 35 1/4 GL2XL GL2ZLH 16 50 K-MT 6 K6/16D2-G230M 56 1/2 GL5XLD GL5ZLDH 16 50 K-MT 7 K7/16D2-G230M 72 1/2 GL5XLD GL5ZLDH 16 50 K-MT 8 K8/16D2-G230M 86 3/4 GL7XLD GL7ZLDH 16 50 1) m3/h, refering to 1 bar a and 20 C at compressor suction capacity. Subsequently compressed to 7 bar e and 35 C inlet temperature to the dryer at 100 % relative humidity for pressure dew points of -25 C and -40 C. 2) In accordance with DIN ISO 228 (BSP-P); alternatively ANSI B 1.20.1 (NPT-F). Operating range Site selection frost-free indoor installation in a non-hazardous environment Ambient temperature 1.5 to 50 C Compressed air inlet temperature 25 to 50 C Operating pressure 5 to 16 bar e Medium Compressed air and gaseous nitrogen Optional dew point sensor ZHM100 Pressure dew point at 7 bar e -40 C ex-factory setting; adjustable via the menu from -25 to -70 C in 5 deg.c. steps Electrical connections Mains voltage Alternative voltage Protection class 230 V, 50-60 Hz 115 V, 50-60 Hz and 24 V DC IP65 Materials of construction Filters Pressure vessels Valve blocks Seals Filling See product-specification regarding GL filter ref: XL and GL filter ref: ZL Aluminium Aluminium NBR 100 % Molecular sieve Pressure vessel approvals EU USA AUS GUS Approval for fluid group 2 in accordance with the Pressure Equipment Directive 97/23/EC. Product range K-MT1 to 2, in accordance with article 3, paragraph 3; product range K-MT3 to 8 in accordance with category I (module A). Approval to ASME VIII Div. 1 not required Approval to AS1210 not required TR (formerly GOST-R)
ecodry K-MT 1-8 adsorption dryer series Dimensions (mm) and weight (kg) A C Model A B C D E Weight K-MT 1 326 400 216 376 101 11.5 K-MT 2 326 575 216 551 101 15,5 K-MT 3 326 825 216 801 101 20 K-MT 4 326 1075 216 1051 101 25 K-MT 6 496 1203 300 1097 132 48 K-MT 7 496 1428 300 1322 132 56.5 K-MT 8 496 1628 300 1522 132 62.5 B D Quality assurance Development/Manufacture DIN EN ISO 9001, DIN EN ISO 14001 E Correction factors (f) in accordance with the actual minimum operating pressure in bar e For a pressure dew point from -25 C to -40 C Inlet temperature to the dryer in C Minimum operating pressure in bar e 25 30 35 40 45 50 5 0.80 0.79 0.75 0.64 0.61 0.59 6 0.92 0.91 0.89 0.78 0.73 0.67 7 1.03 1.02 1.00 0.91 0.82 0.79 8 1.16 1.15 1.13 1.00 0.94 0.86 9 1.30 1.28 1.26 1.08 1.03 0.99 10 1.39 1.37 1.31 1.16 1.07 1.03 11 1.52 1.49 1.36 1.24 1.10 1.07 12 1.61 1.61 1.49 1.36 1.23 1.18 13 1.75 1.75 1.62 1.47 1.35 1.29 14 1.89 1.89 1.71 1.57 1.46 1.38 15 2.00 2.00 1.79 1.67 1.57 1.46 For a pressure dew point from -70 C (at max. 35 C inlet temperature, 100 % relative humidity, continuous operation & with gas-tight piping) Example: maximum inlet volumetric flow of 32 m3/h, at a minimum pressure of 8.3 bar e and 35 C inlet temperature: 32 m3/h : 1.13 = 28.3 m3/h suitable model K-MT 4 for a pressure dew point of -25 C or -40 C; 28.3 m3/h : 0.53 = 53.4 m3/h suitable model K-MT 6 for a pressure dew point of -70 C 0.53 Air quality classes, in accordance with ISO 8573-1:2010 Particulate Class 2 Humidity (gaseous) Class 2 and Class 1 (depending upon sizing and dew point setting) Total oil contamination Class 2
ecodry K-MT 1-8 adsorption dryer series Product key Series Range* pressure Version Generation Connections* Mains voltage* Controls Options* K 1-8 /16 D 2 G 230 M T K 1-8 /16 D 2 G 24D M K 1-8 /16 D 2 N 115 M Examples K 3 /16 D 2 G 230 M K-MT 3 standard version with G1/4" (BSP-P) connections, 230V/50-60Hz Multitronic -plus control. K 3 /16 D 2 N 115 M T K-MT 3 with NPT1/4" connections, 115V/50-60Hz Multitronic-plus control and dew point sensor ZHM100 * variable information Service-kits: Kits for preventive maintenance Order No. Suitability interval Scope of supply SKK1-K4/D2/12 K-MT 1 - K-MT 4 12/36 month Re-set module, silencer and filter elements SKK1-K4/D2/24 K-MT 1 - K-MT 4 24 month Re-set module, wear part set for in-/outlet valves, silencer and filter elements SKK1-K4/D2/48 K-MT 1 - K-MT 4 48 month Re-set module, wear part set for in-/outlet valves, solenoid-coils, non-return valves, Demister, perforated plate, perforated plate gaskets, silencer and filter elements SKK6-K7/D2/12 K-MT 6 - K-MT 7 12/36 month Re-set module, silencer and filter elements SKK6-K7/D2/24 K-MT 6 - K-MT 7 24 month Re-set module, wear part set for in-/outlet valves, silencer and filter elements SKK6-K7/D2/48 K-MT 6 - K-MT 7 48 month Re-set module, wear part set for in-/outlet valves, solenoid-coils, non-return valves, Demister, perforated plate, perforated plate gaskets, silencer and filter elements SKK8/D2/12 K-MT 8 12/36 month Re-set module, silencer and filter elements SKK8/D2/24 K-MT 8 24 month Re-set module, wear part set for in-/outlet valves, silencer and filter elements SKK8/D2/48 K-MT 8 48 month Re-set module, wear part set for in-/outlet valves, solenoid-coils, non-return valves, Demister, perforated plate, perforated plate gaskets, silencer and filter elements DESPACs: Amount of required desiccant packs for each model - for preventive maintenance after 48 months Order No. K-MT 1 K-MT 2 K-MT 3 K-MT 4 K-MT 6 K-MT 7 K-MT 8 DESPAC1MS 1 1 1 DESPAC4MS 1 1 2 3 4 1 DESPAC15MS 1 Loose accessories Order No. Function Suitability Order No. Function Suitability VASRGR/K1-K8 Regeneration gas return K-MT 1 - K-MT 8 VASVPB/K1-K4/08 Start-up device G1/4i K-MT 1 - K-MT 4 VASPDP/K1-K95 Dew point measurement K-MT 1 - K-MT 8 VASVPB/K6-K7/15 Start-up device G1/2i K-MT 6 - K-MT 7 VASMBS420 Signal duplicator 4-20 ma K-MT 1 - K-MT 8 VASVPB/K8/20 Start-up device G3/4i K-MT 8 VASNOZ/K1-K95 Nozzle kit K-MT 1 - K-MT 8 VASFS3/K1-K4 Fine filter muffler K-MT 1 - K-MT 4 VASFS5/K6-K8 Fine filter muffler K-MT 6 - K-MT 8 2011 Parker Hannifin Corporation. All rights reserved. BULKMT1-8-03-EN EMEA Product Information Centre Free phone: 00 800 27 27 5374 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA) US Product Information Centre Toll-free number: 1-800-27 27 537 www.parker.com Your local authorized Parker distributor
ecodry K-MT 10-95 Efficient Compressed Air Adsorption Dryers Short Description K-MT 10-95 heatless adsorption dryers are designed to dry industrial compressed air reliably and efficiently down to a pressure dew point of -70 C. The units are constructed in a compact manner and designed to be free-standing. They are equipped with built-on pre- and after filtration and are sized for volumetric flows of up to 940 m3/h (suction capacity of the compressor referring to a compression of 7 bar e ) Compressed air first enters the validated GL pre-filter. Continuing on, the air flows into one of two twin-vessels; both filled with molecular sieve - a renowned drying-agent, where the air is dried. During the drying process, the second vessel undergoes regeneration: At the start of the drying-cycle, this vessel is open to atmosphere and a small proportion of dried compressed air passes through the adsorption bed, transporting the humidity out. When this procedure is complete, the vessel is re-pressurised in readiness to repeat the drying procedure. Continuous, uninterrupted operation is maintained utilising socalled pressure-swing technology together with individually operated main- and exhaust valves. Dry compressed air finally exits via a validated GL after-filter preventing the migration of particles into the downstream compressed air network. The K-MT 10-95 Adsorption dryer series operates a fixed, timed, changeover-cycle between the two dryer vessels. Where the application calls for a unit able to cope with variations in operating pressure and load, the installation of a dew point sensor at the outlet of the dryer is available as an option: In such an operating mode, the changeover-cycle between vessels only takes place when required, and is dependent on the required dew-point being achieved: Only on reaching this adjustable set-point does changeover to the pre-dried vessel occur. This feature enables the drying phase to be lengthened and thus avoids the unnecessary use of purge air for regeneration. Compressed air can be selectively dried to meet a dew-point of -25 C up to -70 C. Scope of supply: Adsorption dryer - ready for installation, including GL pre- and after filters; available with Dew-point Dependant Switching (DDS) as an option.
ecodry K-MT 10-95 Adsorption dryer series Ordering and Performance data Model Order No. Volumetric flow 1) in m 3 /h pipe size 2) Pre-filter After-filter Pressure in bar e Temp. C K-MT 10 K10/16D2-G230M 105 1 GL9XLD GL9ZLDH 16 50 K-MT 15 K15/16D2-G230M 145 1 GL9XLD GL9ZLDH 16 50 K-MT 20 K20/16D2-G230M 200 1 GL9XLD GL9ZLDH 16 50 K-MT 25 K25/16D2-G230M 255 1 1/2 GL11XLD GL11ZLDH 16 50 K-MT 35 K35/16D2-G230M 350 1 1/2 GL11XLD GL11ZLDH 16 50 K-MT 45 K45/16D2-G230M 420 1 1/2 GL12XLD GL12ZLDH 16 50 K-MT 60 K60/16D2-G230M 620 2 GL13XLD GL13ZLDH 16 50 K-MT 75 K75/16D2-G230M 750 2 GL13XLD GL13ZLDH 16 50 K-MT 95 K95/16D2-G230M 940 2 1/2 GL14XLD GL14ZLDH 16 50 1) m3/h, refering to 1 bar a and 20 C at compressor suction capacity. Subsequently compressed to 7 bar e and 35 C inlet temperature to the dryer at 100% relative humidity for pressure dewpoints of -25 C and -40 C. 2) In accordance with DIN ISO 228 (BSP-P). Operating Range Site Selection frost-free indoor installation in a non-hazardous environment Ambient Temperature 1,5 to 50 C Compressed air inlet temperature 25 to 50 C Operating pressure 5 to 16 bar e Medium Compressed air and gaseous nitrogen Optional dew point sensor ZHM100 Pressure dewpoint at 7 bar e -40 C ex-factory setting; Adjustable via the menu from -25 to -70 C in 5 deg.c. steps Electrical connections Mains Voltage Protection class 230 V, 50-60 Hz IP65 Materials of construction Filters See product-specification regarding GL filter ref: XL and GL filter ref: ZL Pressure vessels Normal steel, welded Valve blocks Aluminium Piping Steel, zinc-coated Seals NBR Filling 100% Molecular sieve Pressure vessel approvals EU AUS GUS Approval for fluid group 2 in accordance with the Pressure Equipment Directive 97/23/EC, Module B+D: Product range K-MT10 to 35, in accordance with category II; Product range K-MT45 to 95 in accordance with category III. AS1210 TR (formerly GOST-R)
ecodry K-MT 10-95 Adsorption dryer series Dimensions in mm. Weight in kg Model A B C D E Weight K-MT 10 870 1420 490 1070 1070 120 K-MT 15 870 1750 490 1320 1320 142 K-MT 20 670 1530 490 1160 1160 143 K-MT 25 670 1760 530 1320 1320 173 K-MT 35 830 1810 585 1320 1320 210 K-MT 45 860 1820 605 1320 1320 249 K-MT 60 910 1870 635 1320 1320 277 K-MT 75 1020 2000 640 1515 1515 408 K-MT 95 1020 2020 670 1515 1515 510 B E D A C Quality Assurance Development/Manufacture DIN EN ISO 9001, DIN EN ISO 14001 Correction factors (f) in accordance with the actual minimum operating pressure in bar e For a pressure dew point from -25 C to -40 C Inlet temperature to the dryer in C Minimum operating pressure in bar e 25 30 35 40 45 50 5 0.80 0.79 0.75 0.64 0.61 0.59 6 0.92 0.91 0.89 0.78 0.73 0.67 7 1.03 1.02 1.00 0.91 0.82 0.79 8 1.16 1.15 1.13 1.00 0.94 0.86 9 1.30 1.28 1.26 1.08 1.03 0.99 10 1.39 1.37 1.31 1.16 1.07 1.03 11 1.52 1.49 1.36 1.24 1.10 1.07 12 1.61 1.61 1.49 1.36 1.23 1.18 13 1.75 1.75 1.62 1.47 1.35 1.29 14 1.89 1.89 1.71 1.57 1.46 1.38 15 2.00 2.00 1.79 1.67 1.57 1.46 For a pressure dew point from -70 C (at max. 35 C inlet temperature, 100 % relative humidity & with gas-tight piping) Example: maximum inlet volumetric flow of 360 m3/h, at a minimum pressure of 8.3 bar e and 35 C inlet temperature: 360 m3/h : 1.13 = 318.6 m3/h Suitable Model K-MT 35 for a pressure dew point of -25 C or -40 C; 318.6 m3/h : 0.53 = 601.1 m3/h Suitable Model K-MT 60 for a pressure dew point of -70 C. 0.53 Air quality classes, in accordance with ISO 8573-1:2010 Particulate Class 2 Humidity / (gaseous) Class 2 and Class 1 (depending upon sizing and dewpoint setting) Total oil contamination Class 2
ecodry K-MT 10-95 Adsorption dryer series Product key Series Range* pressure Version Generation Connections* Mains voltage* Controls Options* K 10-95 /16 D 2 G 230 M T Examples K 35 /16 D 2 G 230 M K-MT 35 standard version with G1 1/2" (BSP-P) connections, 230V/50-60Hz Multitronic -plus control. K 75 /16 D 2 G 230 M T K-MT 75 with G2" (BSP-P) connections, 230V/50-60Hz Multitronic -plus control and dew point sensor ZHM100. * variable information Service-Kits: Preventative Maintenance Kits Order No. Suitability maintenance interval Scope of supply SKK10-K20/D2/12 K-MT 10 to K-MT 20 12 and 36 month SKK25/D2/12 K-MT 25 12 and 36 month SKK35/D2/12 K-MT 35 12 and 36 month SKK45/D2/12 K-MT 45 12 and 36 month Re-set module, Silencer, Filter elements and Pilot valves SKK60-K75/D2/12 K-MT 60 to K-MT 75 12 and 36 month SKK95/D2/12 K-MT 95 12 and 36 month SKK10-K20/D2/24 K-MT 10 to K-MT 20 24 and 48 month SKK25/D2/24 K-MT 25 24 and 48 month SKK35/D2/24 K-MT 35 24 and 48 month Re-set module, Silencer, Filter elements, Inlet-, SKK45/D2/24 K-MT 45 24 and 48 month Outlet- and Non-return valves, Solenoid-coils SKK60-K75/D2/24 K-MT 60 to K-MT 75 24 and 48 month SKK95/D2/24 K-MT 95 24 and 48 month Despacs: Required dessicant pack for each model - for preventive maintenance after 48 months Order No. Suitability Order No. Suitability K-MT10DESMIX K-MT 10 K-MT35DESMIX K-MT 35 K-MT15DESMIX K-MT 15 K-MT60DESMIX K-MT 45 and K-MT 60 K-MT20DESMIX K-MT 20 K-MT75DESMIX K-MT 75 K-MT25DESMIX K-MT 25 K-MT95DESMIX K-MT 95 Accessories Order No. Function Suitability Order No. Function Suitability VASPDP/K1-K95 Dewpoint measurement K-MT 10 to K-MT 95 VASVPB/K10-K20/25 Start-up device G1i K-MT 10 to K-MT 20 VASMBS420 Signal duplicator 4-20 ma K-MT 10 to K-MT 95 VASVPB/K25-K45/40 Start-up device G1 1/2i K-MT 25 to K-MT 45 VASFS5/K10-K15 Fine filter muffler K-MT 10 to K-MT 15 VASVPB/K60-K75/50 Start-up device G2i K-MT 60 to K-MT 75 VASFS5/K20-K25 Fine filter muffler K-MT 20 to K-MT 25 VASVPB/K95/65 Start-up device G2 1/2i K-MT 95 VASFS5/K35-K60 Fine filter muffler K-MT 35 to K-MT 60 VASRGR/K10-K95 Regeneration gas return K-MT 10 to K-MT 95 VASFS5/K75-K95 Fine filter muffler K-MT 75 to K-MT 95 VASNOZ/K1-K95 Nozzle kit K-MT 10 to K-MT 95 2011 Parker Hannifin Corporation. All rights reserved. BULKMT10-95-02-EN EMEA Product Information Centre Free phone: 00 800 27 27 5374 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA) US Product Information Centre Toll-free number: 1-800-27 27 537 www.parker.com Your local authorized Parker distributor
Company Directory: 149 Glasgow Road Wellheads Road Wishaw Farburn Industrial Estate Lanarkshire Dyce, Aberdeen ML2 7QJ AB21 7HG Tel 01698 355711 Tel 01224 723434 Fax 01698 359299 Fax 01224 723545 Fleming Close 8 Burford Way Segensworth East Boldon Business Park Fareham Boldon Hampshire Tyne & Wear PO15 5SB NE35 9PZ Tel 01489 588398 Tel 0191 519 5500 Fax 01489 588381 Fax 0191 537 1105 E-mail sales@mbairsystems.co.uk www.mbairsystems.co.uk www.airwinch.co.uk engineering solutions compressed air design product finishing offshore lifting service pneumatics & tools