Adsorption Dryers for Compressed Air

Similar documents
Adsorption Air Dryers

Adsorption Air Dryers

Adsorption air dryers ADS 1 215

Adsorption Dryers. AD 7 to 1300

Adsorption Dryers. AD 7 to 1300

Adsorption Dryers. DB 05 to 130

Rust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution

ADSORPTION DRYING: WHY?

CDX Refrigerant dryers

CSM hp. Oil-injected screw Compressors Belt driven. The perfect solution for the small businesses. TECHNOLOGY YOU CAN TRUST

Refrigeration dryers DW 2-504

Dryer Systems Heatless Regenerating Adsorption Dryers

Refrigeration dryers DW 2-504

Spiralair SPR 2-30 TECHNOLOGY YOU CAN TRUST

A-DRY Heatless adsorption compressed air dryers

COMPACT CSL range 3-20 HP

VarioDry SPN

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

Dryer Systems Heatless Regenerating Purification Packages

DESICCANT AIR DRYERS. BD + CD + CD series

DESICCANT AIR DRYERS. BD + CD + CD series

Dryer Systems Heat Regenerating Adsorption Dryers

HEATLESS REGENERATED ADSORPTION DRYER ULTRAPAC SMART

Quality air solutions. Refrigerant Dryers Adsorption Dryers Filters Oil-Water Separators Accessories

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

Compressed air preparation Compressed air storage Moisture management. Catalog #1

PNEUDRI High Efficiency Compressed Air Dryers.

Dryer Systems Heatless Regenerating Adsorption Dryers

White paper Compressed air drying

Dryer Systems Heat Regenerating Adsorption Dryers

Dryer Systems Heatless Regenerating Adsorption Dryers

High Efficiency Compressed Air Dryers. Adsorption Dryers Modular System INTELLIGENT AIR TECHNOLOGY

CLEARPOINT THE WINNING COMBINATION FOR CLEAN COMPRESSED AIR

Modular Adsorption Dryers

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

ADSORPTION DRYERS. For all applications which require perfectly dry compressed air : Advantages of "ALC" dryers :

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

TF Series With SECOPAC LS

PNEUDRI High Efficiency Compressed Air Dryers

Atlas Copco. Condensate management. OSC & OSD Oil/water separator series

Ingersoll Rand. Heatless and Heated Blower Desiccant Air Dryers ,900 m 3 /hr

Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

PET Drying Technology

Refrigeration Dryers SECOTEC Air fl ow rate 0.6 to 14.3 m³/min

Membrane Dryers KMM Series

ROLLAIR AIR COMPRESSORS

COMPRESSED AIR TREATMENT

ingersoll rand desiccant dryers

Modular Adsorption Dryers

OIL FREE WATER INJECTED SCREW COMPRESSOR WIS 40-75

Adsorption dryers PDAD

Reciprocating Compressors AIRBOX / AIRBOX CENTER

GB 01 ROTARY SCREW COMPRESSORS FIXED SPEED REGULATED SPEED (RS) L 23 L29 L23RS L29RS INTELLIGENT AIR TECHNOLOGY

Refrigeration Dryers TG TI Series

Rotary Screw Compressors BSD Series With the world-renowned SIGMA PROFILE Air deliveries 3.6 to 8.15 m 3 /min, Pressure 5.

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

ROTARY SCREW COMPRESSORS

Membrane Dryers KMM Series

Desiccant Dryers DC Series (Heatless regenerated) Air flow rates 0.15 to m³/min.

PNEUDRI MiDAS - Mini Dry Air System

Refrigeration Dryers SECOTEC Flow rate 0.6 to 14.3 m³/min

Largo & Allegro. Air Compressors. Largo & Allegro 31-90

Dryer Systems. Breathing Air Units

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

PNEUDRI MiDAS A totally clean and dry compressed air system (CDA)

MDA-Range of Modular Desiccant Compressed Air System

Fixed Speed Rotary Screw Compressors UP6 Series 4-11 kw (5-15 hp)

DESICCANT AIR DRYERS FOR SUPERIOR PRODUCTIVITY

DGH Series Global Air Treatment

Rollair. Rotary Screw Compressors ROLLAIR AND ROLLAIR V

Desiccant Air Drying Technologies HCS Series HCL Series HCT Series

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

COMPRESSED AIR TREATMENT COMPRESSED AIR DRYER

Rollair. Air Compressors. Rollair 40 to 125 and Rollair 40 V to 125 V

D-Series 2 D 3. ultra-high purity compressed air dryers. Flow Capacity: Nm 3 /hr ( scfm)

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

Downstream Equipment. Intelligent Air Technology

COMPRESSED AIR TREATMENT

DRYPOINT AC ADSORPTION DRYERS EFFICIENT, COMPACT, POWERFUL m 3 /h

RN SERIES REFRIGERATED COMPRESSED AIR DRYERS NON-CYCLING REFRIGERATEDERATED COMPRESSED AIR DRYERS SCFM

Rotary Screw Compressors SXC»Compact«Series

HEATLESS DESICCANT AIR DRYERS

Modular Adsorption Dryers

Sonetto. Air Compressors SONETTO 8-20

QUALITY DRY AIR. Atlas Copco Air dryers SOLICITAR INFORMACIÓN MILLIE LÓPEZ ANTONIO ARROYO. FD refrigeration air dryer series Hz (477)

pneudri modular dessicant dryer

Rollair. Air Compressors RLR & RLR E V

AirCel. Heated Regenerative Desiccant Dryers. AEHD Externally Heated, HRE Blower Purge, and HRS-L Zero Purge Series

Subfreezing Dryers SF Dryer, -20 C (-4 F) PDP

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery 0.26 to 0.80 m 3 /min, Pressures bar

OIL-INJECTED ROTARY SCREW COMPRESSORS GX 2-7 EP G 7-15 EL

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

Rotary Screw Compressors SM Series With the world-renowned SIGMA PROFILE Free air delivery 0.28 to 1.52 m³/min, pressures 5.

Thermo Scientific Model 1160 Principle of Operation

Atlas Copco Quality Air Solutions. SD Membrane Dryers

SD Membrane Dryers Quality Air Solutions

DRYPOINT M SOLID STATE MEMBRANE DRYING TECHNOLOGY

ARV -3 & ARV -10 Active Reservoir Vent Installation and Operation Manual

ThermoStar Refrigeration Air Dryers

Atlas Copco. Oil-free Scroll Compressors SF 1-22 ( kw/2-30 hp)

Transcription:

Adsorption Dryers for Compressed Air ADS 1 to 215 Clean and dry air. Prevent the risks, enjoy the benefits. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY

AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY ADS Adsorption Dryers A compressor takes humidity from the intake air which turns into condensate during the compression process. This will cause wear and corrosion to the downstream equipment, with potential costly interruption to production, and reduction in the efficiency and service life of the equipment used. Adsorption dryers provide a solution to prevent this negative impact. SIMPLICITY User benefits Boost quality and productivity - Eliminate any residual water from the net for guaranteed clean compressed air - Ensure your air network is protected against rust avoiding leakages - Higher fi nal product quality - Increase your overall productivity Save costs - Prolong the life span of your operation process (machine/equipment...) - Reduce potential downtime - Energy management solution available to minimise energy consumption Easy operation and installation - Compatible with any compressor technology - User-friendly communication display providing air quality indication and maintenance requirements - Ready to install, with an integrated fi ltration solution (ADS 1-10) - Compact equipment fi ts in a minimum space The Ceccato ADS adsorption dryers will eliminate water vapour that may potentially condensate in your compressed air system and cause damage. These dryers use an adsorption material called desiccant in order to absorb and remove (by regeneration phase) the humidity from the compressed air. With this method we can reach a PDP < 3 C ( -40 C. or -70 C.). This range should also be used when the ambient temperature goes below freezing point, to avoid ice building in pipes and applications. The ADS range is typically used in the chemical, food and pharmaceutical industry and whenever a PDP <3 C is requested. Adsorption removes the remaining moisture content in the air that will condense out even downstream of a refrigerant dryer. Its technology simulates a temperature reduction down to -40 C to -70 C by attracting and retaining moisture with the desiccant media (moisture freezes at +3 C actual temperature reduction) to condense out the very last water content in the air. The moisture is removed from the air fl ow to your network and released. Adsorption dryers are recommended for the most demanding applications, where no moisture contamination can be accepted. Standard features and options Risks to avoid Humid, unclean air can cause: - A dirty air network increases leakage risk - High maintenance cost of your air network (corrosion), operation process and potential downtime - Shorten the life span of your operation process (machine/equipment) - Risk of water contamination in the air network, with potential freezing in winter time - Lower quality of the fi nal product causing potential risk of product recalls - Reduced productivity STANDARD FEATURES AND OPTIONS ADS 1-10 ADS 15-156 ADS 110-215 Capacity at 7 bar (- 40 C) 114-990 l/1 1500-15600 l/min 10800-21600 l/1 Dew point Standard -40 C Standard -20 C Standard -40 C Standard -40 C Maximum working pressure 16 bar 14 bar 11 and 14,5 bar Working pressure range 4-16 bar 4-14 bar 4-11 bar & 11-14,5 bar Voltages 12-24 V - DC 50/60Hz 115-230 V - AC 50/60Hz 230 V - AC 50/60Hz 100-115 - 230V - AC 50/60Hz Dew point sensor Optional Dew point -70 C = available = not available By derating the air capacity Available on the -40 C version (for models ADS 21 and larger) and with a rated flow reduction of 30%

APPLICATIONS & DRYING PROCESS Residual oil Application for ADS dryer Particularly for: - The chemical and pharmaceutical Industries. - Petrochemical plants. - Food industry. - Transportation of hygroscopic materials. - Quality painting. - Textile production. - Semiconductors. - Cable pressurization. - Beer and drinks production. - Applications in low-temperature environments. -... and whenever a pressure dew point less than 3 C is requested. -20 C / 40 C (2.1.2)* Laborotories Painting Cold zones Instruments Residual particles 1µm -70 C (2.1.1)* Very cold regions External installations Semiconductors 0,01 mg/m 3 Food industries * Quality class according to ISO 8573-1 The drying process 1 inlet filter 2 inlet valve Drying: 3 silencers S* Wet air from the compressors passes through the inlet filter (1) which removes the oil and enters into vessel A. The desiccant adsorbs the water vapor molecules. After a fi xed (STD) or variable adsorbing time (CD) the inlet valve (2) deviates the airfl ow from vessel A to vessel B, where the air continues to be dried. Regeneration: During the drying phase in vessel A, some dry air is deviated into vessel B. Flowing from top to bottom, the dried air is able to remove the water vapor from the desiccant material. During this phase, vessel B is open to the atmosphere, allowing the purge air to expand. The silencers (3) on the outlet ensure quiet operation. 1 P max atm. A B P max atm. G** C 2 Pressurization: Once regeneration has taken place, vessel B is pressurized again so that the inlet valve (2) can change the air fl ow again. 3 Adsorbent material Unsaturated Saturated Inlet valve Discharge silencer Prefi lters and Postfi lter Humidity detector (CD) * On ADS1-10 outlet fi lter is built inside of the desiccant cartridges. ** Recommended but not included on ADS156

A compact quality air solution for easy installation and maintenance ADS 1-10 STD RANGE Compact execution Versatile installation with multiport system and six possible connections. Compact, reduced footprint, simple design. This module can be installed horizontally or vertically, can stand on the fl oor or be mounted on a wall (optional mounting kit available). The inlet prefi lter C is delivered loose with the dryer but it can be directly fi xed on it. The outlet postfi lters are integrated in the desiccant cartridges. Aluminium head, base and cylinders prevent corrosion. Easy to maintain: - Maintenance operations can be performed without disconnecting tubing. - Adsorbent cartridge with built-in postfi lter. Automatic electronic control to manage the dryer and phase status with an automatic fault diagnosis, including alarms. Each tower is fi tted with a high effi ciency silencer for quiet operation. Components 1 Prefi lter removes particulates and coalesced liquids from the air sytem. 2 Removable front panel allows for easy access for servicing without disconnecting the pipe system. 1 3 Postfi lters, integrated in the dryer, removes particulate in the air stream. 4 Electronic control housed in an IP65 box which enables: - regeneration cycle management - regulation status - default diagnosis - remote default report 3 4 3 2 MULTIPORT INLET AND OUTLET THIS ARRANGEMENT ENSURES EASY AND FAST INSTALLATION Applications for ADS 1-215

Energy efficient and solid performance ADS 15-156 Reliability improved fl ow unique valve system desiccant protection fl ow distributor - swirl Performance high-effi ciency silencers lower noise level very low purge consumption PDP -20 C / -40 C PDP -70 C optional dew point sensor (optional) Features digital controller nozzle purge set for different pressures synchronization possibility with the compressor two included fi lters (loose) Options PDP sensor and selection Wall-mounting kit for units with 2 columns New swirl technology ensures optimal distribution of the airfl ow and decreases uneven wear of the desiccant.

Perfectly clean and dry air system with a clever dew point management ADS 110-215 RANGE Electric timer control (STD) Control dew point (CD) Developed with high quality components. ADS dryers guarantee a stable dew point of -40 C. The use of an optimised desiccant volume and a wide vessel ensure a low air speed and a longer contact time. Purge phases are controlled by an electronic timer on the standard models (ADS / STD). There is also a dew point control version (ADS / CD) where the drying phase is dew point dependent and is controlled by our electronic dew point management system. The two inlet prefi lters G - C and the outlet postfi lter S have to be mounted on the air distribution line. The fi lters are included but not pre-mounted. Components 1 Wide vessels for optimum air spread and reliable drying. 2 Air outlet connection. 3 Robust frame, including fork lift slots for easy installation. 4 Pressure dew point sensor (ADS / CD). 5 Pressure dew point digital display (ADS / CD). 6 7 8 9 10 11 Two manometers integrated in the control panel to show pressure in the two vessels. Purge nozzle for regeneration. Galvanized piping with fl anged connections. High effi ciency silencers with integrated safety valve. Air inlet connection. Inlet valves, long service interval. 1 4 5 6 7 2 9 9 8 11 10 3 How to decrease your energy consumption? The electronic Pressure Dew Point control (CD) extends the drying phase of the dryer s cycle. It is done by measuring PDP of compressed air on the dryer outlet and only switching the columns when desiccant in the active tower is saturated. The regeneration part of the cycle stays fi xed. As most of the time compressor and dryer runs < 100% load, this results in a signifi cant extension of the drying time and a reduction in purge air consumption. Typically the extra investment in a Pressure Dew Point control is paid back in a few months by savings made on dryer running costs.

ADSORPTION DRYERS ADS 1-215 Technical data for PDP -40 C version For dimensions & weight for the version PDP -20 C, please refer to the dimension drawing AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST SIMPLICITY RELIABILITY Max. Working Pressure Operating Pressure Air Treatment Capacity Standard Dew Point G 0,1 mg/ mc C 0,01 mg/ mc S (MPPS=0,1 µm) 99,81% Inlet / outlet Connections Dimensions Weight Type BAR psi BAR l/1 m 3 /h cfm C Pre fi lters Post fi lters Gas A B C kg ADS 1 16 232 7,0 114 7 4,1-40 n.a. C 7 1 3/8 92 281 445 13 ADS 2 16 232 7,0 168 10 5,9-40 n.a. C 7 3/8 92 281 504 14 ADS 3 ADS 4 16 16 232 232 7,0 7,0 282 426 17 26 10 15,3-40 -40 n.a. n.a. C 7 C 7 Integrated in the dryer 3/8 3/8 92 92 281 281 635 815 17 20 ADS 7 16 232 7,0 708 42 24,7-40 n.a. C 7 3/8 92 281 1065 24 ADS 10 16 232 7,0 990 59 34,7-40 n.a. C 15 1/2 92 281 1460 31 ADS 15 14 203 7 1500 90 53-40 n.a. C 15 S 15 1" 401 620 1070 87 ADS 21 14 203 7 2100 126 74-40 n.a. C 21 S 21 1" 401 620 1115 88 ADS 27 14 203 7 2700 162 95-40 n.a. C 30 S 30 1" 401 620 1285 99 ADS 33 14 203 7 3300 198 116-40 n.a. C 48 S 48 1" 401 620 1465 114 ADS 39 14 203 7 3900 234 138-40 n.a. C 48 S 48 1" 401 620 1615 124 ADS 54 14 203 7 5400 324 191-40 n.a. C 84 S 84 1" 1/2 571 620 1285 165 ADS 66 14 203 7 6600 396 233-40 n.a. C 84 S 84 1" 1/2 571 620 1465 197 ADS 78 14 203 7 7800 468 275-40 n.a. C 84 S 84 1" 1/2 571 620 1615 211 ADS 99 14 203 7 9900 594 350-40 n.a. C 114 S 114 1" 1/2 571 620 1915 245 ADS 117 14 203 7 11700 702 413-40 n.a. C 156 S 156 1" 1/2 738 620 1615 298 ADS 156 14 203 7 15600 936 551-40 n.a. C 156 S 156 1" 1/2 738 620 1915 328 2 A C B ADS 110 ADS 130 ADS 180 ADS 215 11 159 7,0 10800 648 381-40 14,5 210 12,5 12900 774 456-40 11 159 7,0 13200 792 466-40 14,5 210 12,5 15900 954 561-40 11 159 7,0 18000 1080 636-40 14,5 210 12,5 21600 1296 763-40 11 159 7,0 21600 1296 763-40 14,5 210 12,5 25800 1548 911-40 G 114 C 114 S 114 1 ½ 840 1040 1760 445 G 156 C 156 S 156 1 ½ 840 1040 1760 445 G 216 C 216 S 216 2 840 1040 1760 600 G 216 C 216 S 216 2 840 1040 1760 650 1 Reference conditions: Operating pressure: see the technical data table / Operating temperature: 35 C / Relative humidity: 100% 2 Filters are delivered loose with the dryer: ADS 1-10: the fi lters can be directly fi xed on the dryer. ADS 15-215: the fi lters have to be mounted on the air distribution line. For conditions differing from the reference conditions, use the below correction factor table. Correction factors Correction factors ADS/14 or 16 bar (max. working pressure) Air Inlet Pressure - bar 4 5 6 7 8 9 10 11 12 13 14 14,5 15 16 ADS 1 - ADS 10 0,62 0,75 0,87 1 1,12 1,25 1,37 1,5 1,62 1,75 1,87 1,93 2 2,12 ADS 15 - ADS 156 0,62 0,75 0,87 1 1,12 1,25 1,37 1,5 1,62 1,75 1,87 Correction factors ADS/11 bar (max. working pressure) ADS/14,5 bar (max. working pressure) Air Inlet Pressure - bar 4 5 6 7 8 9 10 11 11 12,5 13 14 14,5 ADS 110 - ADS 215 0,47 0,68 0,84 1 1,1 1,2 1,3 1,38 0,89 1 1,04 1,11 1,15 Correction factors Air Inlet Temperature C 20 25 30 35 40 45 50 ADS 1 - ADS 10 1,07 1,06 1,04 1 0,88 0,78 0,55 ADS 15 - ADS 156 1 1 1 1 0,84 0,67 0,55 ADS 110 - ADS 215 1 1 1 1 0,84 0,71 0,55 Correction factors Pressure Dew Point C -20-40 -70 ADS 1-10 & ADS 110-251 n.a. 1 0.7 ADS 15 - ADS 156 1 1 0,7 C A B

AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY Adsorption air dryers Range ADS 1 215 A high quality product offering you technology you can trust. Our products are easy to use and guarantee high reliability. Distributors are always nearby ensuring availability of both products and support. Choosing our high performance products entails a partnership that will boost your business. Safeguarding long-term productivity through optimal serviceability and use of original parts. Care. Care is what service is all about: professional service by knowledgeable people, using high-quality original parts. Trust. Trust is earned by delivering on our promises of reliable, uninterrupted performance and long equipment lifetime. Efficiency. Equipment efficiency is ensured by regular maintenance. Efficiency of the service organization is how Original Parts and Service make the difference. 6999100164 2015, Ceccato. All rights reserved. All mentioned brands, product names, company names, trademarks and service marks are the properties of their respective owners. Our products are constantly being developed and improved. We thus reserve the right to modify product specifi cations without prior notice. Pictures are not contractually binding. Contact your local Ceccato representative now! www.ceccato-compressors.com