FUME EXTRACT STRATEGY STATEMENT

Similar documents
Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Oakdale Primary School Expansion Project Appendix A - MEP Schedule of Works

Quality Products AHU Repair, Refurbishment and Replacement

Prescriptive Requirement for Smoke Control

DOCUMENT TABLE OF CONTENTS

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

WHHR Midi & Midi Lite

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Exhaust Duct Design Page 1 of (C)

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Permanent Ventilators (for the Supply of Combustion Air)

Food Service Establishment Plan Review Form

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

ventilation solutions for schools, academies, colleges and universities

KITCHEN EXTRACTORS K Series

Eco Active H E A T R E C O V E R Y S Y S T E M S H Y B R I D U N I T. W: T:

vent With family and friends to take care of, it goes without saying you need the help of reliable kitchen appliances.

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

Planning Application for the Aylesbury Estate Regeneration. Plot 18 Reserved Matters Application. Ventilation Statement. Aecom

INSTALLATION DO S AND DON TS

AIR HANDLING UNITS MANDÍK

Roof: sound attenuation Category B. 4.0 DOORS

ACCUBLOC high performance Heat Recovery

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

Energy Recovery, Wholehouse Ventilation ECO LIVING

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

SECTION DUCTWORK

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Fire dampers. For diverse applications

The Heating System and Ventilation and Combustion Air

CLEANAIRE. The energy efficient way to achieve a dry, healthy home. Product Information

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

2015 MECHANICAL CODE REQUIREMENTS

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Third Edition. Prepared by the Department of Building and Housing

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

HeATING. VENTILATION. COOLING. in ONE SYSTEM.

Verification Methods For New Zealand Building Code Clause G4 Ventilation

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXTRACTION SYSTEMS

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

SMOKE CONTROL - NEW DIRECTIONS

UNIJET CAR PARK VENTILATION SYSTEM

technical specification smoke venting systems

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

FRESHVENT. Select a product. Home/Freshvent

Ventilation for New Low-Rise Residential Buildings July 20, 2015

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Warnings, Safety Information and Guidance

GIVE A FAN A CHANCE Installation Dos & Don ts

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Centeral Station Air Handling Unit

Ventilation System Description. September 8, 2000 HETA

Stainless Steel Sanitary Ware

2012 INTERNATIONAL FUEL GAS CODE VENTS

DUCTING FOR HRV SYSTEMS The distribution of airflows

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

Varius Application of Dynair Fans

EXHAUST FAN SCHEDULE

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

Contents Chapters 4 & 5 of the 2012 Michigan Mechanical Code CHAPTER 4, MMC: VENTILATION CHAPTER 5, MMC: EXHAUST SYSTEMS

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

FIRE AND SECURITY CONSULTING SERVICES

Purge Ventilation Unit. Product Manual. ventilation systems TP625

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

Heat recovery unit RDKS

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

IMC Significant Changes Summary Tier I

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

ACCUBLOC high performance Heat Recovery

Cooling Strip Model SPB

Appliance Operation Manual

Colt ventilation systems for car parks, loading bays and service areas

Operating Performance

Instructions Manual CTB CTB 9407

Dee Fly Cube 300 and 370. Heat Recovery ventilation

FMH Range Hoods. Installation, Operation & Maintenance Instructions

Stainless Steel Chimney Extractor

Plus Perimeter Aspiration Timer Remote control predisposition

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

DESCRIPTION OF TECHNOLOGY

MECHANICAL VENTILATION

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Stainless Steel Chimney Extractor

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems

BEST PRACTICE RECOMMENDATIONS

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

Mechanical System Description

SAVE VTC 700. Heat Recovery Ventilation Unit

Transcription:

FUME EXTRACT STRATEGY STATEMENT : New Islington Free School No: 7/4781 The site is located in central Manchester on an area of disused land adjacent to the Rochdale canal. The site forms a roughly rectangular shaped parcel of land. The site is proposed to be developed into a two storey free school with car and bicycle parking facilities. Kitchen Ventilation The kitchen on the ground floor of the school building will be provided with a mechanical supply and extract ventilation system. The kitchen ventilation systems will comply with Building Regulations Document F 2010 and HVCA DW172. Extract ventilation with balanced (85%) supply air make up will be provided to the kitchen. Supply and extract air will be provided by an air handling plant positioned within the ground floor plantroom. The air handling plant supply and extract air will be ducted to the kitchen area. A ventilation canopy of stainless steel construction will be positioned above the kitchen cooking appliances and equipment. The extract air ventilation rate will be designed to provide a suitable effective face velocity on the canopy. Supply air will be provided at a rate of 85% of the extract ventilation duty. The extract section of the ventilation canopies will provide grease filtration with activated carbon filters. The cooking processes employed within school can cause odour pollution problems. The kitchen ventilation systems will be designed to diminish odour pollution. The extract air discharge will be at least 1m above the roof level with high velocity cone to discharge the exhaust air away from any surrounding buildings and occupied areas. No exhaust air will be discharged at low level. Supply and extract ductwork will comply with HVCA DW144 galvanised sheet metal ductwork. Extract ductwork routed between fire compartments will be installed using fire rated ductwork. Fire dampers will be installed in supply ductwork where ductwork passes through a fire compartment. Extract fans will be fire rated to 300 o C. Access panels will be provided in the supply and extract ductwork to facilitate ductwork cleaning. Acoustic attenuators will be provided on the inlet and outlet of supply and extract fans to attenuate air borne noise at source.

Volume control dampers will be installed within the supply air ductwork system to allow balancing and commissioning. General & Toilet Extract Ventilation The toilets and a number of other rooms will be provided with mechanical extract ventilation. make up air will be provided via under-cut doors and door transfer grilles. Extract fans will be installed within ceiling voids. Air will be ducted to discharge to atmosphere through the roof with terminal. Supply and extract ductwork will comply with HVCA DW144 galvanised sheet metal ductwork. Extract ductwork routed between fire compartments will include fusible link fire dampers. Access panels will be provided in the supply and extract ductwork to facilitate ductwork cleaning. Acoustic attenuators will be provided on the inlet and outlet of supply and extract fans to attenuate air borne noise at source. Volume control dampers will be installed within the supply air ductwork system to allow balancing and commissioning. Boiler Flues The boiler flues off the heating and hot water boilers located within the ground floor plantroom will discharge to atmosphere at least 1m above the roof level. The flues off each appliance will common together within the ground floor plantroom and then rise through the first floor of the building to discharge to atmosphere above the roof. The following drawings have been prepared to demonstrate the fume exhaust strategy: - Drawing No. 7/4781/E701 Rev P2 Ground Floor Plantroom Layout 7/4781/E702 Rev P2 Building Elevations, Mechanical Services 7/4781/E703 Rev P2 Roof Plan, Mechanical Services Penetrations 7/4781/E704 Rev P2 Ground & First Floor, Louvre Locations

GAS FIRED WATER HEATER: HEATING PUMPS PRESS. UNIT PANEL BOILER 1 BOILER 2 CONTROL VESSEL EXPANSION PRE-FABRICATED BOILER ASSEMBLY AS POTTERTON PARAMOUNT THREE MB SERIES 900L x 600W x 1528H MAINTENANCE SPACE: 300 EITHER SIDE 1000 IN FRONT COLD WATER BOOSTER SET WITH NOMINAL 1000 LITRE BREAK TANK ABOVE (TANK NOMINAL SIZE: 1000x1000x1000) SERVICES CONTROL PANEL FLUES FOR GAS FIRED APPLIANCES COMBINED. COMBINED FLUE TO RUN VERTICALLY THROUGH THE BUILDING IN A PROTECTED FIRE RATED SHAFT TO DISCHARGE ABOVE THE ROOF LINE AT FIRST FLOOR LEVEL. PLANT POWER, LIGHTNG & LIGHTING EXTERNAL INCOMING TELECOM / DATA INCOMING ELECTRICAL SUPPLIES MAIN PANEL REF: MP1 WITH BUILT IN AUTOMATIC MULTI-STEP POWER FACTOR CORRECTION, TRANSIENT SURGE PROTECTION AND INCOMING ACB ZONE FOR SERVICES ROUTING (AT HIGH LEVEL) ZONE FOR ELECTRICAL SERVICES ROUTING (AT HIGH LEVEL) P2 20.01.14 ARCHITECTS COMMENTS SM P1 17.01.14 ISSUE SM INCOMING WATER MAIN & METER GAS METER INCOMING GAS MAIN SUPPLY AHU 3100L x 1150W x 1050H FRESH AIR INTAKE LOUVRE: 1000x1000 BASED ON 50% FREE AREA ZONE FOR DUCTWORK ROUTING (AT HIGH LEVEL) KITCHEN EXTRACT EXHAUST LOUVRE ABOVE DOOR: 600x1200 BASED ON 50% FREE AREA MIN 1.2M BETWEEN INTAKE & EXHAUST DUCTS. HIGH AND LOW LEVEL VENTILATION FOR BOILERS TO BE INCORPORATED INTO LOUVRED PLANTROOM DOORS. HIGH LEVEL: 0.46M² FREE AREA LOW LEVEL: 0.092M² FREE AREA GROUND FLOOR PLANTROOM LAYOUT 1:20 7/4781 M 701 P2

FLUES FOR GAS FIRED APPLIANCES COMBINED. COMBINED FLUE TO RUN VERTICALLY THROUGH THE BUILDING IN A PROTECTED FIRE RATED SHAFT TO DISCHARGE ABOVE THE ROOF LINE AT FIRST FLOOR LEVEL. INCOMING POWER & DATA SUPPLIES ALL BELOW GROUND LEVEL WEST ELEVATION FLUES FOR GAS FIRED APPLIANCES COMBINED. COMBINED FLUE TO RUN VERTICALLY THROUGH THE BUILDING IN A PROTECTED FIRE RATED SHAFT TO DISCHARGE ABOVE THE ROOF LINE AT FIRST FLOOR LEVEL. P2 20.01.14 ARCHITECTS COMMENTS SM P1 17.01.14 ISSUE SM INCOMING GAS AND WATER SUPPLIES. WATER ENTERS BUILDING BELOW GROUND, GAS ENTERS ABOVE GROUND. INCOMING GAS SUPPLY MAIN FRESH AIR INTAKE LOUVRE: 1000x1000 BASED ON 50% FREE AREA HIGH AND LOW LEVEL VENTILATION FOR BOILERS TO BE INCORPORATED INTO LOUVRED PLANTROOM DOORS. MINIMUM AREA REQUIRED: HIGH LEVEL: 0.46M² FREE AREA LOW LEVEL: 0.092M² FREE AREA KITCHEN EXTRACT EXHAUST LOUVRE ABOVE DOOR: 600x1200 BASED ON 50% FREE AREA SOUTH ELEVATION BUILDING ELEVATIONS SERVICES REQUIREMENTS 1:20 7/4781 M 702 P2

REDHILL STREET 110Ø SOIL VENT PIPES PENETRATE ROOF TERMINATING WITH A WEATHERING COWL. ROOF PENETRATION FINISHED WITH A WEATHERING SLATE. 2 No. 1100 x 1100 x 740 h NATURAL VENTILATION PENTHOUSE LOUVRES (AS MONODRAUGHT WINDCATCHER OR EQUIVALENT) 110Ø SOIL VENT PIPES PENETRATE ROOF TERMINATING WITH A WEATHERING COWL. ROOF PENETRATION FINISHED WITH A WEATHERING SLATE. FLUE FROM GAS FIRED BOILERS AND WATER HEATER IN GROUND FLOOR PLANTROOM RISE THROUGH IT SUITE IN A PROTECTED FIRE RATED SHAFT TO DISCHARGE ABOVE THE ROOF LINE. REFER TO PLANTROOM DRAWING M701 FOR FURTHER DETAILS. 1 No. OPENING FOR FRESH AIR INLET & 1 No. OPENING FOR EXHAUST AIR DISCHARGE SERVING HEAT RECOVERY VENTILATION UNITS IN THE IT SUITE & IMMERSIVE SPACE. OPENINGS APPROX 500 x 500. SUITABLE WEATHER COWLS TO BE FITTED OVER OPENINGS. 2 No. ROOF MOUNTED AIR COOLED CONDENSING UNITS SERVING COOLING TO IMMERSIVE SPACE & IT SUITE. 400 x 400 OPENING IN ROOF FOR TOILET EXTRACT FANS TERMINALS TO ACCOMMODATE VENTILATION FROM GROUND & FIRST FLOOR VENTILATION. SUITABLE WEATHER COWLS TO BE FITTED OVER OPENINGS. FIRST FLOOR ROOF LEVEL REDHILL STREET ROOF OPENING FOR EXTRACT VENTILATION SERVING REPRO ROOM. OPENING APPROX 400 x 400. SUITABLE WEATHER COWL TO BE FITTED OVER OPENING. 400 x 400 OPENING IN ROOF FOR TOILET EXTRACT FAN. SUITABLE WEATHER COWLS TO BE FITTED OVER OPENINGS. P2 20.01.14 ARCHITECTS COMMENTS SM P1 17.01.14 ISSUE SM 1 No.FRESH AIR INLET AND 1 No. EXHAUST AIR OPENING IN ROOF SERVING HEAT RECOVERY VENTILATION UNITS IN THE SENCO & SICK SPACES. OPENINGS APPROX 400 x 400. SUITABLE WEATHER COWLS TO BE FITTED OVER OPENINGS. GROUND FLOOR ROOF LEVEL ROOF LEVEL LAYOUT / PENETRATIONS 1:150 7/4781 M 703 P2

REDHILL STREE FIRST FLOOR PLAN RED P2 20.01.14 ARCHITECTS COMMENTS SM P1 17.01.14 ISSUE SM KITCHEN EXTRACT EXHAUST LOUVRE ABOVE DOOR: 600x1200 BASED ON 50% FREE AREA MIN 1.2M BETWEEN INTAKE & EXHAUST DUCTS. FRESH AIR INTAKE LOUVRE: 1000x1000 BASED ON 50% FREE AREA HIGH AND LOW LEVEL VENTILATION FOR BOILERS TO BE INCORPORATED INTO LOUVRED PLANTROOM DOORS. HIGH LEVEL: 0.46M² FREE AREA LOW LEVEL: 0.092M² FREE AREA GROUND FLOOR PLAN GROUND & FIRST FLOOR LOUVRE LOCATIONS PLAN 1:150 7/4781 M 704 P2