GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

Similar documents
Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Technical Data. Dimensions

Technical Data. Dimensions

Technical Data. Dimensions

Temperature sensors SensyTemp TSP Measuring insets TSA

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Inductive slot sensor

Technical Data. Dimensions

OPTIBAR DP 7060 Supplementary Instructions

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

OPTIBAR P 1010/2010 C Supplementary instructions

Technical Data. General specifications. Rated operating distance s n 5 mm

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Indoor/outdoor resistance thermometer Model TR60

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Gas cylinder scale Model GCS-1

Snifter ATEX22 VERSION. User Manual. Distributor

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

PEPPERL+FUCHS GmbH

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Multipoint temperature sensor

Supplementary Installation and Operating Instructions. Category II2G

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Physikalisch-Technische Bundesanstalt

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

INSTRUCTION MANUAL (ATEX / IECEx)

Temperature Measurement Transmitters for field mounting

Centurion Guided Radar HAWK CGR SERIES

Manual Power relay SR853

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

EU DECLARATION OF CONFORMITY

Temperature Sensor TRG Original Installation Instructions English

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

EtherCAT Box Modules (EPxxxx-xxxx)

Safety instructions VEGABAR 81, 82, 83, 86, 87

4) Intrinsic Safety Certification

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

SITRANS. Temperature sensors SITRANS TSinsert/TS100/TS200/ TS500. Introduction 1. Safety information 2. Description 3. Installation 4.

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Flameproof Manual Call Points

INSTRUCTION & SERVICE MANUAL

INSTRUCTION MANUAL (ATEX / IECEx)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

CA 134. Piezoelectric accelerometer. IECEx NEPSI TIIS KGS. » From the Vibro-Meter product line» Vibration monitoring over a wide temperature

OilSET-1000 (12 VDC)

MANUAL Oil Level Sensor

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Gas expansion thermometer

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

standards: standards:

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Switches compliant with ATEX directive

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

SET Installation and Operating Instructions. Level switch for one sensor

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

GMH 285 / GMH 285-BNC

Annubar Flowmeter Series

ATEX, NOMENCLATURE AND CODING

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Flange immersion heaters

Safety instructions VEGAPULS 64

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

SITRANS T temperature transmitters A broad product family for every application. sitrans

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Continuous Gas Analyzers AO2000 Series AO2040-CU Ex Central Unit in Category 2G. Operator s Manual 42/24-13 EN Rev. 3

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

14300 MAINS SEPARATOR ALARM MANUAL

Only for operating with ATEX certificated sensors DMT 99 ATEX E056/N5 Maximum optical input power Maximum radiation intensity Detection pattern

ATEX, NOMENCLATURE AND CODING

Operating Instructions Edition 02/2007

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Operating Instruction OI/TSC400-EN. SensyTemp TSC400 Industrial thermometer. For plug-in connection For screw-in connection For surface measurement

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Transcription:

Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de

Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 2 of 10 INDEX 1 INTRODUCTION... 3 1.1 General... 3 1.2 Which temperature-probe, transmitter, display etc. do I need?... 3 2 SAFETY INSTRUCTIONS... 5 2.1 General... 5 2.2 Safety instructions for zone 0 or zone 20... 6 2.3 Limited ambient conditions... 6 2.3.1 GTF 103-Ex-G...-types... 6 2.3.2 GTF 103-Ex-O...-types... 6 2.3.3 GTF 103-Ex-O...H...-types... 6 2.4 Connection values and ambient conditions... 6 3 INSTALLATION HINTS... 7 3.1 Layout for Pt 100 and Pt 1000 in 2-, 3-, 4- wire technology... 7 3.2 Thermocouples type K and type N... 7 3.3 Screwed cable gland... 7 3.3.1 Standard... 7 3.3.2 Modification: increased ambient temperature... 8 4 PROBE-TYPES AND AREAS OF APPLICATION... 8 5 SPECIFICATION... 9 6 ORDERING INFORMATION FOR GTF 103-EX-... PROBES... 10 7 DECLARATION OF CONFORMITY APPENDIX 8 EC-TYPE-EXAMINATION-CERTIFICATE APPENDIX

Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 3 of 10 1 Introduction 1.1 General The temperature-probes GTF 103-Ex are mounting probes for usage in potentially explosive atmospheres of all zones. Greatest flexibility is given by the modular build up of the GTF 103-Ex. The temperature-probes are equipped with a head (IP 65). The head can function as a connection head or as a housing for a head transmitter. The probe-inserts of the GTF 103-Ex are available for two different sensor-groups: resistance thermometer: Pt 100, Pt 1000 or thermocouple : type K, type N (standard). Only mineral insulated sensor elements are used. The GTF 103-Ex can be employed in medium-temperatures from -200 C to + 900 C. The permissible ambient temperature in the area of the connection head depends on the temperature class, the potential explosive zone, the medium-temperature, and the screwed cable gland. For the standard screwed cable gland the permissible maximal ambient temperature ranges from 20 C to + 60 C ( see chapter 2.3) and for the modification higher ambient temperature (GTF 103-Ex-...H...-types) from -20 C to +80 C. Apart from the probe-inserts with a probe diameter 3mm all probe-inserts of the GTF 103-Ex are exchangeable. The used material of the probes which encounter the medium are made of stainless steel (e.g. 1.4404, 1.4435, 1.4571 or Inconel 600 ). This ensures high stability against many chemical compounds. If the medium-temperature exceeds 100 C all GTF 103-Ex must have a neck tube length of at least 50mm (standard). It is also possible to produce longer neck tubes. You can choose between 48 GTF 103-Ex basis-types. Also all basis-types could be produced according to your instructions. 1.2 Which temperature-probe, transmitter, display etc. do I need? You can easy find out the needed temperature-probe or transducer for your special application from the table given below. Zone 0 or 20 A GTF 103-Ex can be used, if the temperature has to be acquired in Ex-zone 0 or 20. Only ATEX- certified display- and control-devices, matching the demands of the certain zone, are allowed to be used.

Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 4 of 10 Zone 1,2 or 21, 22 A GTF 103-Ex matching the protection class Ex ia IIC T6 or Ex e II T6 and Ex iad or Ex td A21 can be used, if the temperature has to be acquired in EX-zone 1, 2 or 21, 22. In case the controlling- or displaying device is also in zone 1, 2 or 21, 22 only ATEX certified devices matching the demands of the certain zone are allowed to be used. In case the controlling- or displaying device is beyond the explosion hazardous area, this device does not need an Ex-certification if a temperature-probe GTF 103-Ex matching the protection class increased safety (Ex e II T6 or Ex td A21) is used and the safety instructions given in chapter 2 are fulfilled Table 1: Overview of application and demands to a GTF 103-Ex and the display-/ control-device in different Ex-zones Ex-zone: probe 0, 20 0/1, 20/21 1, 2, 21, 22 1, 2, 21, 22 Ex-zone: device 0, 20 1, 2, 21, 22 1, 2, 21, 22 no Ex-zone applicable GTF 103-Ex- types ATEX-marking GTF 103-Ex- GTF 103-Ex-G..J.. GTF 103-Ex-O..J.. with special provisions (see chapter 2.2Fehler! Verweisquelle konnte nicht gefunden werden.) II 1G Ex ia T6 II 1D Ex iad 20 IP65 T80 C Ta = -20 C +40 C GTF 103-Ex-G..J.. GTF 103-Ex-O..J.. II 1/2G Ex ia T6 II 1/2D Ex iad 20 IP65 T80 C GTF 103-Ex-G... GTF 103-Ex-O... II 2G Ex ia T6 II 2D Ex iad 21 IP65 T80 C or II 2G Ex e T6 II 2D Ex td A21 IP65 T80 C GTF 103-Ex-O... II 2G Ex e T6 II 2D Ex td A21 IP65 T80 C ATEX demand on devices II 1G or II 1D II 1G; II (1)2G Ex ia IIC, II 2G Ex ia IIC or II 1D; II (1)2D Ex iad IIC, II 2D Ex iad IIC II 2G or II 2D GTF 103-Ex type-code is shown in chapter Specification. without ATEXadmission

Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 5 of 10 2 Safety instructions 2.1 General 1. Only install the GTF 103-Ex according to the given manufacturer s instructions and observe general standards and precepts. 2. The temperature sensors with the type of protection Increased Safety (e) are allowed to be connected only to the resistance sensors or thermocouples according to the relevant standard for this part. The nominal electrical operating parameters may not exceed. 3. Every temperature sensor with the type of protection Increased Safety (e), has to be used with a series fuse, which is suitable for the possible short-circuit current of 1500A. The series fuse can be installed into the associated supply device or into the evaluation device. 4. Setting up the head transmitter is only allowed to be done in a non hazardous area. 5. Before changing the measuring-insert the connections must be disconnected. 6. In the case of using the complete GTF 103-Ex in the hazardous area which required the category 1, the safety instructions for zone 0 or zone 20 (p.r.t. chapter 2.2Fehler! Verweisquelle konnte nicht gefunden werden.) have to be fulfilled. 7. Only use cable with allowable diameter and associated sealings of the cable entry point. The connection piece of the cable entry point must not be detached. Use blue pressure screw of the cable entry point for intrinsic safety circuits. 8. Arrange circuit points according to the given connection diagram. The anode (positive pole) of thermocouples is marked with a red label. 9. The maximal ambient temperature which is specified in the EC-type-examination certificate do not may be over ranged in the entire area of the connection head. Influences of adjacent heat-sources are to be considered. 10. The self heating of the device s tube has to be considered for the application, if loading the measure-circuitry with more than 40mW. The summation of the medium-temperature and the temperature of the sensortube from the device s self heating must always be lower than the ignition temperature of the medium. 11. The chemical resistance of the material has to be checked with the manufacturer, if using in aggressive mediums. 12. The probe line of the temperature sensor is to be installed in such a way which ensures sufficient protection against mechanical damage. The bending especially of the long sensor tube has to be prevented. Where appropriate fasten elements are to be mounted in suitably distances.

Temperature rise ( C) Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 6 of 10 2.2 Safety instructions for zone 0 or zone 20 These instructions are only valid if the complete GTF 103-Ex is to be installed in zone 0 or zone 20. 1. The explosive mixtures are allowed to occur only in atmospheric conditions of -20 C Ta +60 C and 0,8 bar p 1,1 bar. 2. Please take notice of the limited ambient temperatures (see chapter 2.3) 3. The power supply circuit must fulfil ignition classification Ex ia IIC or Ex iad IIC. 4. The GTF 103-Ex materials must be completely compatible with the measured media (housing : aluminium, sealing: silicon; label: polyester with acrylic glue) 5. The GTF 103-Ex must be installed so that there is no chance of electrostatic charging. 2.3 Limited ambient conditions 2.3.1 GTF 103-Ex-G...-types temperature class T6 2.3.2 GTF 103-Ex-O...-types temperature class T6 2.3.3 GTF 103-Ex-O...H...-types temperature class T6 zone 0-20 C Ta +40 C zone 0-20 C Ta +40 C zone 0-20 C Ta +60 C zone 1 and 2-20 C Ta +50 C zone 1 and 2-20 C Ta +60 C zone 1 and 2-20 C Ta +80 C 2.4 Connection values and ambient conditions The measure-circuit should not be loaded with more than 40mW. When not exceeding this value, the temperature at the sensor-tube will raise 4 C maximum compared to ambient temperature. The temperature probe GTF 103-Ex must only be used, if this increase of temperature compared to the medium-temperature within the container is allowable. The self heating of the device has to be considered for the application, if loading the measurecircuit in fault with more than 40mW. The summation of the medium- temperature and the temperature of the sensor-tube from the device s self heating up must always, even in fault, be lower than the ignition temperature of the medium. Temperature rise of GTF 103-Ex 160 140 120 100 80 60 40 20 0 0 500 1000 1500 2000 2500 Load (mw) Figure1: Temperature rise vs. load of the measure circuit The given requirements in safety instructions for the supply-unit and the display-/control-device must be objected.

Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 7 of 10 3 Installation hints The layout for GTF 103-Ex-G...types with head-transmitter GITT01-Ex or TMT181..-B.. is given in the operating manual of the head-transmitter. 3.1 Layout for Pt 100 and Pt 1000 in 2-, 3-, 4- wire technology 1= 1= 1= 3= 3= 4L 3L 2L 2= 2= 2= 4= Figure 2: Layout 3.2 Thermocouples type K and type N The connection for the anode (positive pole) is marked with a red label. 3.3 Screwed cable gland The protection-degree of the connection head is IP 65. The user is committed to use cables with the specified diameter only. The assembly has to be done appropriate. If the assembly is not done appropriate explosion hazard is given! Attention: the cable has to be protected against pull out (e.g. with a cable clamp). Factory-made the connection piece of the screwed cable gland is clotted with the sensor head. Violent dismounting or detaching is not permissible (Torque > 3,75 Nm). The pressure screw of the screwed cable gland has to be tested for leak, regularly and has to be tightened if necessary. Reconstruction or modifications at the screwed cable gland or the sensor are not allowed. Only original parts are allowed to be used if repair work is necessary. 3.3.1 Standard Only round cables with the following external diameters (ED) are allowed to use: ED (mm) sealing 1 and sealing 2 for ED (mm) sealing 1 for ED (mm) GTF 103-Ex 5,5-13 5,5-8 8-13 Use the right sealing for your cable (see figure 4). The pressure screw has to be tightened well to ensure the protection-degree IP 65 (2,50 Nm). Violent tightening can lead to impairment of the protection-degree.

Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 8 of 10 figure 4: assembly of the screwed cable gland connection piece pressure screw sealing 2 sealing 1 clamping range 5,5 8 mm: push sealing 1 onto sealing 2 and insert the cable through sealing 2. clamping range 8 13 mm: remove sealing 2 and insert the cable through sealing 1. 3.3.2 Modification: increased ambient temperature ED (mm) GTF 103-Ex-...H... 6,5-13 4 Probe-types and areas of application The GTF 103-Ex are available in 48 different designs. The GTF 103-Ex are equipped with a head. The head has to offer sufficient space for a head transmitter. Furthermore the measuring inserts of the GTF 103-Ex are changeable without dismounting the whole probe (apart from probe-tube ED = 3 mm). All further specifications adapt to the sensor, the temperature-range, the ambient temperature, and the needed type of protection. Standard-probes are manufactured with a probe-length of 100 mm, a probe-diameter of 6 mm, a screw thread G=1/2 and for media-temperatures >100 C with a neck tube-length of 50 mm. For extra charge we will assemble probes according to your instructions (as far as possible). GTF 103-Ex-..JM... GTF 103-Ex-..NM... GTF 103-Ex-..NK... HL FL HL FL FL

Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 9 of 10 5 Specification Measuring range: Pt100/Pt1000 without neck tube: -200 C...+100 C Pt100/Pt1000 with neck tube: -200 C...+600 C Thermocouples without neck tube: -200 C...+100 C Thermocouples type K with neck tube: -200 C...+900 C Thermocouples type N with neck tube: -200 C...+900 C Sensor- elements Probe-tubes: Head: All sensor-elements are mineral insulated Pt100 cl. B, Pt1000 cl. B with 2-, 3-, or 4-wire connection thermocouples type K, type N Material of screw thread and probe-tubes: stainless steel (1.4404, 1.4435, 1.4571, Inconel 600 et al.) Standard: without neck tube: screw thread G = ½ A, FL = 100 mm, D = 6 mm, WS 1,0 mm with neck tube: screw thread G = ½ A, FL = 100 mm, D = 6 mm, WS 1,0 mm, HL = 50 mm, D = 8 mm Aluminium, protection-degree: IP 65, silicon-sealing ambient temperature (max): -20 C...+80 C D = 68 mm; H = 63 mm, screw thread: M 24x1,5 space for head transmitter: D x H = 44 x 23 mm or connection socket (6 pole) Screwed cable gland: Standard Material: polyamide, sealing CR/NBR ambient temperature max.: -20 C...+60 C IP 66 Clamping range: Ø 5,5-13 mm higher ambient temperature max.: -20 C...+80 C Material: polyamide, sealing and O-Ring NBR IP 68-10 bar Clamping range: Ø 6,5 12 mm For individual types please make exact specification of: probe-length (FL), probe-diameter (D), neck-tube-length (HL), ambient temperature, measuring range, sensor-element, sensor-accuracy, and type of protection Available components (possibly not useable for all protection-types and zones) Probe-tube diameter: 3, 4, 5, 6, 8 mm notice: at diameter 3 mm: minimum-length = 60 mm, the diameter is reduced: 6mm to 3mm Kind of screw thread: Size of screw thread: Sensor-elements: G, R, NPT, M - external screw thread 1/8, ¼, 3/8, ½, ¾, 8x1, 10x1, 14x1 Pt 100, Pt 1000, TC-type K, TC-type N

Z31.0.XX.6C-11 Operating Manual GTF 103-Ex... page 10 of 10 6 Ordering information for GTF 103-Ex-... probes Ordering information for GTF 103-Ex... probes GTF 103-Ex- / MB: Normalized signal: O w ithout normalizid signal output G w ith normalized signal output: 4-20 ma Sensor-element: P Pt100 S Pt1000 T Thermocouple type K U Thermocouple type N Screw thread: J w ith screw thread N w ithout screw thread (only for zone 1, 2, 21 and 22) Neck tube: K w ithout neck tube (for T 100 C) M w ith neck tube (for T > 100 C) Ambient temperature: A Standard zone 0, 20: -20 C... +40 C zone 0/1, 1, 2, 20/21, 21, 22: -20 C... +50 C (with norm. signal output) zone 0/1, 1, 2, 20/21, 21, 22: -20 C... +60 C (w ithout norm. signal output) H Higher ambient temperature zone 0, 20: -20 C... +60 C zone 0/1, 1, 2, 20/21, 21, 22: -20 C... +80 C (w ithout norm. signal output) only for protection type intrinsic safety "i" only available for GTF 103-Ex-O... types (= without norm. Signal output) Kind of screw thread: 0 w ithout thread 1 G-screw thread (cylindric) 2 M-screw thread (metric) other screw thread on request Size of screw thread: 0 w ithout tread 1 1/8" 2 1/4" 3 3/8" G-screw thread 4 1/2" 5 3/4" 6 8x1 7 10x1 M-screw thread 8 14x1 Neck-tube length: xxx length in mm e.g. 050 (= 50 mm = standard length) Probe-tube diameter: x 3, 4, 5, 6 or 8 mm Hints: - for zone 0, 0/1, 20 and 20/21 only 6 mm or 8 mm available - observe for D = 3 mm (only for Pt100 or Pt1000 available): minimum length is 60 mm the probe diameter is reduced, tube top D = 3 mm (for approx. 30 mm) after this D = 6 mm the measuring insert is not changeable Probe length: xxxx length in mm e.g. 0100 (= 100 mm) Protection type: e Gases: increased safety (e) - only permitted in zone 1 and 2 Dusts: protection by enclosure (td) - only permitted in zone 21 and 22 i intrinic safety Hint: increased safety: in case the connected device is beyond the explosion hazardous area, this device does not need an Ex-certification. (take a note to the safety advice!) Potentially explosive atmospheres: Gases: 00 zone 0 0A zone 0/1 - probe-tube in zone 0 and probe head in zone 1 01 zone 1 02 zone 2 Dusts: 20 zone 20 2A zone 20/21 - probe-tube in zone 20 and probe head in zone 21 21 zone 21 22 zone 22 Measuring range: xxx measuring range of the probe e.g. -50... +100 C Hint: in the zones 0, 0/1, 20 or 20/21 only G 3/8", G 1/2" or G 3/4" are avialable. Ordering-example: GTF 103-Ex with 4-20 ma signal, Pt100, with screw thread, medium temperature: >100 C, ambient temperature: 40 C, kind of screw thread: G-screw thread, size: 1/2", neck-tube length: 50 mm, probe-diameter: 6 mm, probe-length 200 mm, protection type "i", zone 0, measuring range: -50 to +100 C GTF 103-Ex- G P J M A 1 4 0 5 0 6 0 2 0 0 i 0 0 / MB: -50... +100 C